-
High angular sensitivity X-ray phase-contrast microtomography of soft-tissue through a two-directional beam-tracking synchrotron set-up
Authors:
Carlos Navarrete-Leon,
P. Stephen Patrick,
Adam Doherty,
Harry Allan,
Silvia Cipiccia,
Shashidhara Marathe,
Kaz Wanelik,
Michela Esposito,
Charlotte K. Hagen,
Alessandro Olivo,
Marco Endrizzi
Abstract:
Two-directional beam-tracking (2DBT) is a method for phase-contrast imaging and tomography that uses an intensity modulator to structure the X-ray beam into an array of independent circular beamlets that are resolved by a high-resolution detector. It features isotropic spatial resolution, provides two-dimensional phase sensitivity, and enables the three-dimensional reconstructions of the refractiv…
▽ More
Two-directional beam-tracking (2DBT) is a method for phase-contrast imaging and tomography that uses an intensity modulator to structure the X-ray beam into an array of independent circular beamlets that are resolved by a high-resolution detector. It features isotropic spatial resolution, provides two-dimensional phase sensitivity, and enables the three-dimensional reconstructions of the refractive index decrement, $δ$, and the attenuation coefficient, $μ$. In this work, we report on the angular sensitivity and the spatial resolution of 2DBT images in a synchrotron-based implementation. In its best configuration, we obtained angular sensitivities of $\sim$20 $n$rad and spatial resolution of at least 6.25 $μ$m in phase-contrast images. We also demonstrate exemplar application to the three-dimensional imaging of soft tissue samples, including a mouse liver and a decellularised porcine dermis.
△ Less
Submitted 15 December, 2023;
originally announced December 2023.
-
Direct x-ray scattering signal measurements in edge-illumination/beam-tracking imaging and their interplay with the variance of the refraction signals
Authors:
Ian Buchanan,
Silvia Cipiccia,
Carlo Peiffer,
Carlos Navarrete-León,
Alberto Astolfo,
Tom Partridge,
Michela Esposito,
Luca Fardin,
Alberto Bravin,
Charlotte K Hagen,
Marco Endrizzi,
Peter RT Munro,
David Bate,
Alessandro Olivo
Abstract:
X-ray dark-field or ultra-small angle scatter imaging has become increasingly important since the introduction of phase-based x-ray imaging and is having transformative impact in fields such as in vivo lung imaging and explosives detection. Here we show that dark-field images acquired with the edge-illumination method (either in its traditional double mask or simplified single mask implementation)…
▽ More
X-ray dark-field or ultra-small angle scatter imaging has become increasingly important since the introduction of phase-based x-ray imaging and is having transformative impact in fields such as in vivo lung imaging and explosives detection. Here we show that dark-field images acquired with the edge-illumination method (either in its traditional double mask or simplified single mask implementation) provide a direct measurement of the scattering function, which is unaffected by system-specific parameters such as the autocorrelation length. We show that this is a consequence both of the specific measurement setup and of the mathematical approach followed to retrieve the dark-field images. We show agreement with theoretical models for datasets acquired both with synchrotron and laboratory x-ray sources. We also introduce a new contrast mechanism, the variance of refraction, which is extracted from the same dataset and provides a direct link with the size of the scattering centres. We show that this can also be described by the same theoretical models. We study the behaviour of both signals vs. key parameters such as x-ray energy and scatterer radius. We find this allows quantitative, direct, multi-scale scattering measurements during imaging, with implications in all fields where dark-field imaging is used.
△ Less
Submitted 12 July, 2023;
originally announced July 2023.
-
X-ray phase-contrast micro tomography of soft tissues using a compact laboratory system with two-directional sensitivity
Authors:
Carlos Navarrete-Leon,
Adam Doherty,
Savvas Savvidis,
Mattia F. M. Gerli,
Giovanni Piredda,
Alberto Astolfo,
Silvia Cipiccia,
David Bate,
Charlotte K. Hagen,
Alessandro Olivo,
Marco Endrizzi
Abstract:
X-ray micro tomography is a non-destructive, three-dimensional inspection technique applied across a vast range of fields and disciplines, ranging from research to industrial, encompassing engineering, biology and medical research. Phase-contrast imaging extends the domain of application of X-ray micro tomography to classes of samples that exhibit weak attenuation, thus appear with poor contrast i…
▽ More
X-ray micro tomography is a non-destructive, three-dimensional inspection technique applied across a vast range of fields and disciplines, ranging from research to industrial, encompassing engineering, biology and medical research. Phase-contrast imaging extends the domain of application of X-ray micro tomography to classes of samples that exhibit weak attenuation, thus appear with poor contrast in standard X-ray imaging. Notable examples are low-atomic-number materials, like carbon-fibre composites, soft matter and biological soft tissues. We report on a compact and cost effective system for X-ray phase-contrast micro tomography. The system features high sensitivity to phase gradients and high resolution, requires a low-power sealed X-ray tube, a single optical element, and fits in a small footprint. It is compatible with standard X-ray detector technologies: single-photon-counting offers higher sensitivity whereas flat-panels are preferred for a larger field of view. The system is benchmarked against known-material phantoms and its potential for soft-tissue three-dimensional imaging is demonstrated on small-animal organs: a piglet oesophagus and a rat heart.
△ Less
Submitted 15 December, 2022;
originally announced December 2022.
-
Fabrication of High-Aspect Ratio Nanogratings for Phase-based X-ray Imaging
Authors:
Martyna Michalska,
Alessandro Rossi,
Gasper Kokot,
Callum M. Macdonald,
Silvia Cipiccia,
Peter R. T. Munro,
Alessandro Olivo,
Ioannis Papakonstantinou
Abstract:
Diffractive optical elements such as periodic gratings are fundamental devices in X-ray imaging - a technique that medical, material science and security scans rely upon. Fabrication of such structures with high aspect ratios at the nanoscale creates opportunities to further advance such applications, especially in terms of relaxing X-ray source coherence requirements. This is because typical grat…
▽ More
Diffractive optical elements such as periodic gratings are fundamental devices in X-ray imaging - a technique that medical, material science and security scans rely upon. Fabrication of such structures with high aspect ratios at the nanoscale creates opportunities to further advance such applications, especially in terms of relaxing X-ray source coherence requirements. This is because typical grating-based X-ray phase imaging techniques (e.g., Talbot self-imaging) require a coherence length of at least one grating period and ideally longer. In this paper, the fabrication challenges in achieving high aspect-ratio nanogratings filled with gold are addressed by a combination of laser interference and nanoimprint lithography, physical vapor deposition, metal assisted chemical etching (MACE), and electroplating. This relatively simple and cost-efficient approach is unlocked by an innovative post-MACE drying step with hexamethyldisilazane, which effectively minimizes the stiction of the nanostructures. The theoretical limits of the approach are discussed and, experimentally, X-ray nanogratings with aspect ratios >40 demonstrated. Finally, their excellent diffractive abilities are shown when exposed to a hard (12.2 keV) monochromatic x-ray beam at a synchrotron facility, and thus potential applicability in phase-based X-ray imaging.
△ Less
Submitted 31 October, 2022;
originally announced November 2022.
-
Cycloidal-spiral sampling for three-modal x-ray CT flyscans with two-dimensional phase sensitivity
Authors:
G. Lioliou,
O. Roche i Morgó,
S. Marathe,
K. Wanelik,
S. Cipiccia,
A. Olivo,
C. K. Hagen
Abstract:
We present a flyscan compatible acquisition scheme for three-modal X-Ray Computed Tomography (CT) with two-dimensional phase sensitivity. Our approach is demonstrated using a "beam tracking" setup, through which a sample's attenuation, phase (refraction) and scattering properties can be measured from a single frame, providing three complementary contrast channels. Up to now, such setups required t…
▽ More
We present a flyscan compatible acquisition scheme for three-modal X-Ray Computed Tomography (CT) with two-dimensional phase sensitivity. Our approach is demonstrated using a "beam tracking" setup, through which a sample's attenuation, phase (refraction) and scattering properties can be measured from a single frame, providing three complementary contrast channels. Up to now, such setups required the sample to be stepped at each rotation angle to sample signals at an adequate rate, to prevent resolution losses, anisotropic resolution, and under-sampling artefacts. However, the need for step** necessitated a step-and-shoot implementation, which is affected by motors overheads and increases the total scan time. By contrast, our proposed scheme, by which continuous horizontal and vertical translations of the sample are integrated with its rotation (leading to a "cycloidal-spiral" trajectory), is fully compatible with continuous scanning (flyscans). This leads to greatly reduced scan times while largely preserving image quality and isotropic resolution.
△ Less
Submitted 25 August, 2022;
originally announced August 2022.
-
X-ray Ptychography with a Laboratory Source
Authors:
Darren J. Batey,
Frederic Van Assche,
Sander Vanheule,
Matthieu N. Boone,
Andrew J. Parnell,
Oleksandr O. Mykhaylyk,
Christoph Rau,
Silvia Cipiccia
Abstract:
X-ray ptychography has revolutionised nanoscale phase contrast imaging at large-scale synchrotron sources in recent years. We present here the first successful demonstration of the technique in a small-scale laboratory setting. We conducted an experiment with a liquid metal-jet X-ray source and a single photon-counting detector with a high spectral resolution. The experiment used a spot size of 5…
▽ More
X-ray ptychography has revolutionised nanoscale phase contrast imaging at large-scale synchrotron sources in recent years. We present here the first successful demonstration of the technique in a small-scale laboratory setting. We conducted an experiment with a liquid metal-jet X-ray source and a single photon-counting detector with a high spectral resolution. The experiment used a spot size of 5 microns to produce a ptychographic phase image of a Siemens star test pattern with a sub-micron spatial resolution. The result and methodology presented show how high-resolution phase contrast imaging can now be performed at small-scale laboratory sources worldwide.
△ Less
Submitted 10 February, 2021; v1 submitted 7 February, 2021;
originally announced February 2021.
-
Characterisation of Laser Wakefield Acceleration Efficiency with Octave Spanning Near-IR Spectrum Measurements
Authors:
M. J. V. Streeter,
Y. Ma,
B. Kettle,
S. J. D. Dann,
E. Gerstmayr,
F. Albert,
N. Bourgeois,
S. Cipiccia,
J. M. Cole,
I. Gallardo González,
A. E. Hussein,
D. A. Jaroszynski,
K. Falk,
K. Krushelnick,
N. Lemos,
N. C. Lopes,
C. Lumsdon,
O. Lundh,
S. P. D. Mangles,
Z. Najmudin,
P. P. Rajeev,
R. Sandberg,
M. Shahzad,
M. Smid,
R. Spesyvtsev
, et al. (3 additional authors not shown)
Abstract:
We report on experimental measurements of energy transfer efficiencies in a GeV-class laser wakefield accelerator. Both the transfer of energy from the laser to the plasma wakefield, and from the plasma to the accelerated electron beam were diagnosed by simultaneous measurement of the deceleration of laser photons and the acceleration of electrons as a function of plasma length. The extraction eff…
▽ More
We report on experimental measurements of energy transfer efficiencies in a GeV-class laser wakefield accelerator. Both the transfer of energy from the laser to the plasma wakefield, and from the plasma to the accelerated electron beam were diagnosed by simultaneous measurement of the deceleration of laser photons and the acceleration of electrons as a function of plasma length. The extraction efficiency, which we define as the ratio of the energy gained by the electron beam to the energy lost by the self-guided laser mode, was maximised at $19\pm3$\% by tuning of the plasma density and length. The additional information provided by the octave-spanning laser spectrum measurement allows for independent optimisation of the plasma efficiency terms, which is required for the key goal of improving the overall efficiency of laser wakefield accelerators.
△ Less
Submitted 20 December, 2022; v1 submitted 2 November, 2020;
originally announced November 2020.
-
AWAKE, The Advanced Proton Driven Plasma Wakefield Acceleration Experiment at CERN
Authors:
E. Gschwendtner,
E. Adli,
L. Amorim,
R. Apsimon,
R. Assmann,
A. -M. Bachmann,
F. Batsch,
J. Bauche,
V. K. Berglyd Olsen,
M. Bernardini,
R. Bingham,
B. Biskup,
T. Bohl,
C. Bracco,
P. N. Burrows,
G. Burt,
B. Buttenschon,
A. Butterworth,
A. Caldwell,
M. Cascella,
E. Chevallay,
S. Cipiccia,
H. Damerau,
L. Deacon,
P. Dirksen
, et al. (66 additional authors not shown)
Abstract:
The Advanced Proton Driven Plasma Wakefield Acceleration Experiment (AWAKE) aims at studying plasma wakefield generation and electron acceleration driven by proton bunches. It is a proof-of-principle R&D experiment at CERN and the world's first proton driven plasma wakefield acceleration experiment. The AWAKE experiment will be installed in the former CNGS facility and uses the 400 GeV/c proton be…
▽ More
The Advanced Proton Driven Plasma Wakefield Acceleration Experiment (AWAKE) aims at studying plasma wakefield generation and electron acceleration driven by proton bunches. It is a proof-of-principle R&D experiment at CERN and the world's first proton driven plasma wakefield acceleration experiment. The AWAKE experiment will be installed in the former CNGS facility and uses the 400 GeV/c proton beam bunches from the SPS. The first experiments will focus on the self-modulation instability of the long (rms ~12 cm) proton bunch in the plasma. These experiments are planned for the end of 2016. Later, in 2017/2018, low energy (~15 MeV) electrons will be externally injected to sample the wakefields and be accelerated beyond 1 GeV. The main goals of the experiment will be summarized. A summary of the AWAKE design and construction status will be presented.
△ Less
Submitted 17 December, 2015;
originally announced December 2015.
-
Path to AWAKE: Evolution of the concept
Authors:
A. Caldwell,
E. Adli,
L. Amorim,
R. Apsimon,
T. Argyropoulos,
R. Assmann,
A. -M. Bachmann,
F. Batsch,
J. Bauche,
V. K. Berglyd Olsen,
M. Bernardini,
R. Bingham,
B. Biskup,
T. Bohl,
C. Bracco,
P. N. Burrows,
G. Burt,
B. Buttenschon,
A. Butterworth,
M. Cascella,
S. Chattopadhyay,
E. Chevallay,
S. Cipiccia,
H. Damerau,
L. Deacon
, et al. (96 additional authors not shown)
Abstract:
This report describes the conceptual steps in reaching the design of the AWAKE experiment currently under construction at CERN. We start with an introduction to plasma wakefield acceleration and the motivation for using proton drivers. We then describe the self-modulation instability --- a key to an early realization of the concept. This is then followed by the historical development of the experi…
▽ More
This report describes the conceptual steps in reaching the design of the AWAKE experiment currently under construction at CERN. We start with an introduction to plasma wakefield acceleration and the motivation for using proton drivers. We then describe the self-modulation instability --- a key to an early realization of the concept. This is then followed by the historical development of the experimental design, where the critical issues that arose and their solutions are described. We conclude with the design of the experiment as it is being realized at CERN and some words on the future outlook. A summary of the AWAKE design and construction status as presented in this conference is given in [1].
△ Less
Submitted 29 November, 2015;
originally announced November 2015.
-
Proton-driven plasma wakefield acceleration: a path to the future of high-energy particle physics
Authors:
AWAKE Collaboration,
R. Assmann,
R. Bingham,
T. Bohl,
C. Bracco,
B. Buttenschon,
A. Butterworth,
A. Caldwell,
S. Chattopadhyay,
S. Cipiccia,
E. Feldbaumer,
R. A. Fonseca,
B. Goddard,
M. Gross,
O. Grulke,
E. Gschwendtner,
J. Holloway,
C. Huang,
D. Jaroszynski,
S. Jolly,
P. Kempkes,
N. Lopes,
K. Lotov,
J. Machacek,
S. R. Mandry
, et al. (25 additional authors not shown)
Abstract:
New acceleration technology is mandatory for the future elucidation of fundamental particles and their interactions. A promising approach is to exploit the properties of plasmas. Past research has focused on creating large-amplitude plasma waves by injecting an intense laser pulse or an electron bunch into the plasma. However, the maximum energy gain of electrons accelerated in a single plasma sta…
▽ More
New acceleration technology is mandatory for the future elucidation of fundamental particles and their interactions. A promising approach is to exploit the properties of plasmas. Past research has focused on creating large-amplitude plasma waves by injecting an intense laser pulse or an electron bunch into the plasma. However, the maximum energy gain of electrons accelerated in a single plasma stage is limited by the energy of the driver. Proton bunches are the most promising drivers of wakefields to accelerate electrons to the TeV energy scale in a single stage. An experimental program at CERN -- the AWAKE experiment -- has been launched to study in detail the important physical processes and to demonstrate the power of proton-driven plasma wakefield acceleration. Here we review the physical principles and some experimental considerations for a future proton-driven plasma wakefield accelerator.
△ Less
Submitted 2 April, 2014; v1 submitted 20 January, 2014;
originally announced January 2014.