-
Cosmology Large Angular Scale Surveyor (CLASS) Focal Plane Development
Authors:
D. T. Chuss,
A. Ali,
M. Amiri,
J. Appel,
C. L. Bennett,
F. Colazo,
K. L. Denis,
R. Dünner,
T. Essinger-Hileman,
J. Eimer,
P. Fluxa,
D. Gothe,
M. Halpern,
K. Harrington,
G. Hilton,
G. Hinshaw,
J. Hubmayr,
J. Iuliano,
T. A. Marriage,
N. Miller,
S. H. Moseley,
G. Mumby,
M. Petroff,
C. Reintsema,
K. Rostem
, et al. (6 additional authors not shown)
Abstract:
The Cosmology Large Angular Scale Surveyor (CLASS) will measure the polarization of the Cosmic Microwave Background to search for and characterize the polarized signature of inflation. CLASS will operate from the Atacama Desert and observe $\sim$70% of the sky. A variable-delay polarization modulator (VPM) modulates the polarization at $\sim$10 Hz to suppress the 1/f noise of the atmosphere and en…
▽ More
The Cosmology Large Angular Scale Surveyor (CLASS) will measure the polarization of the Cosmic Microwave Background to search for and characterize the polarized signature of inflation. CLASS will operate from the Atacama Desert and observe $\sim$70% of the sky. A variable-delay polarization modulator (VPM) modulates the polarization at $\sim$10 Hz to suppress the 1/f noise of the atmosphere and enable the measurement of the large angular scale polarization modes. The measurement of the inflationary signal across angular scales that span both the recombination and reionization features allows a test of the predicted shape of the polarized angular power spectra in addition to a measurement of the energy scale of inflation.
CLASS is an array of telescopes covering frequencies of 38, 93, 148, and 217 GHz. These frequencies straddle the foreground minimum and thus allow the extraction of foregrounds from the primordial signal. Each focal plane contains feedhorn-coupled transition-edge sensors that simultaneously detect two orthogonal linear polarizations. The use of single-crystal silicon as the dielectric for the on-chip transmission lines enables both high efficiency and uniformity in fabrication. Integrated band definition has been implemented that both controls the bandpass of the single mode transmission on the chip and prevents stray light from coupling to the detectors.
△ Less
Submitted 13 November, 2015;
originally announced November 2015.
-
Recovery of Large Angular Scale CMB Polarization for Instruments Employing Variable-delay Polarization Modulators
Authors:
N. J. Miller,
D. T. Chuss,
T. A. Marriage,
E. J. Wollack,
J. W. Appel,
C. L. Bennett,
J. Eimer,
T. Essinger-Hileman,
D. J. Fixsen,
K. Harrington,
S. H. Moseley,
K. Rostem,
E. R. Switzer,
D. J. Watts
Abstract:
Variable-delay Polarization Modulators (VPMs) are currently being implemented in experiments designed to measure the polarization of the cosmic microwave background on large angular scales because of their capability for providing rapid, front-end polarization modulation and control over systematic errors. Despite the advantages provided by the VPM, it is important to identify and mitigate any tim…
▽ More
Variable-delay Polarization Modulators (VPMs) are currently being implemented in experiments designed to measure the polarization of the cosmic microwave background on large angular scales because of their capability for providing rapid, front-end polarization modulation and control over systematic errors. Despite the advantages provided by the VPM, it is important to identify and mitigate any time-varying effects that leak into the synchronously modulated component of the signal. In this paper, the effect of emission from a $300$ K VPM on the system performance is considered and addressed. Though instrument design can greatly reduce the influence of modulated VPM emission, some residual modulated signal is expected. VPM emission is treated in the presence of rotational misalignments and temperature variation. Simulations of time-ordered data are used to evaluate the effect of these residual errors on the power spectrum. The analysis and modeling in this paper guides experimentalists on the critical aspects of observations using VPMs as front-end modulators. By implementing the characterizations and controls as described, front-end VPM modulation can be very powerful for mitigating $1/f$ noise in large angular scale polarimetric surveys. None of the systematic errors studied fundamentally limit the detection and characterization of B-modes on large scales for a tensor-to-scalar ratio of $r=0.01$. Indeed, $r<0.01$ is achievable with commensurately improved characterizations and controls.
△ Less
Submitted 19 February, 2016; v1 submitted 14 September, 2015;
originally announced September 2015.
-
Wide-Stopband Aperiodic Phononic Filters
Authors:
K. Rostem,
D. T. Chuss,
K. L. Denis,
E. J. Wollack
Abstract:
We demonstrate that a phonon stopband can be synthesized from an aperiodic structure comprising a discrete set of phononic filter stages. Each element of the set has a dispersion relation that defines a complete bandgap when calculated under a Bloch boundary condition. Hence, the effective stopband width in an aperiodic phononic filter (PnF) may readily exceed that of a phononic crystal with a sin…
▽ More
We demonstrate that a phonon stopband can be synthesized from an aperiodic structure comprising a discrete set of phononic filter stages. Each element of the set has a dispersion relation that defines a complete bandgap when calculated under a Bloch boundary condition. Hence, the effective stopband width in an aperiodic phononic filter (PnF) may readily exceed that of a phononic crystal with a single lattice constant or a coherence scale. With simulations of multi-moded phononic waveguides, we discuss the effects of finite geometry and mode-converting junctions on the phonon transmission in PnFs. The principles described may be utilized to form a wide stopband in acoustic and surface wave media. Relative to the quantum of thermal conductance for a uniform mesoscopic beam, a PnF with a stopband covering 1.6-10.4 GHz is estimated to reduce the thermal conductance by an order of magnitude at 75mK.
△ Less
Submitted 14 March, 2016; v1 submitted 13 September, 2015;
originally announced September 2015.
-
Measuring the Largest Angular Scale CMB B-mode Polarization with Galactic Foregrounds on a Cut Sky
Authors:
Duncan J. Watts,
David Larson,
Tobias A. Marriage,
Maximilian H. Abitbol,
John W. Appel,
Charles L. Bennett,
David T. Chuss,
Joseph R. Eimer,
Thomas Essinger-Hileman,
Nathan J. Miller,
Karwan Rostem,
Edward J. Wollack
Abstract:
We consider the effectiveness of foreground cleaning in the recovery of Cosmic Microwave Background (CMB) polarization sourced by gravitational waves for tensor-to-scalar ratios in the range $0<r<0.1$. Using the planned survey area, frequency bands, and sensitivity of the Cosmology Large Angular Scale Surveyor (CLASS), we simulate maps of Stokes $Q$ and $U$ parameters at 40, 90, 150, and 220 GHz,…
▽ More
We consider the effectiveness of foreground cleaning in the recovery of Cosmic Microwave Background (CMB) polarization sourced by gravitational waves for tensor-to-scalar ratios in the range $0<r<0.1$. Using the planned survey area, frequency bands, and sensitivity of the Cosmology Large Angular Scale Surveyor (CLASS), we simulate maps of Stokes $Q$ and $U$ parameters at 40, 90, 150, and 220 GHz, including realistic models of the CMB, diffuse Galactic thermal dust and synchrotron foregrounds, and Gaussian white noise. We use linear combinations (LCs) of the simulated multifrequency data to obtain maximum likelihood estimates of $r$, the relative scalar amplitude $s$, and LC coefficients. We find that for 10,000 simulations of a CLASS-like experiment using only measurements of the reionization peak ($\ell\leq23$), there is a 95% C.L. upper limit of $r<0.017$ in the case of no primordial gravitational waves. For simulations with $r=0.01$, we recover at 68% C.L. $r=0.012^{+0.011}_{-0.006}$. The reionization peak corresponds to a fraction of the multipole moments probed by CLASS, and simulations including $30\leq\ell\leq100$ further improve our upper limits to $r<0.008$ at 95% C.L. ($r=0.01^{+0.004}_{-0.004}$ for primordial gravitational waves with $r=0.01$). In addition to decreasing the current upper bound on $r$ by an order of magnitude, these foreground-cleaned low multipole data will achieve a cosmic variance limited measurement of the E-mode polarization's reionization peak.
△ Less
Submitted 19 November, 2015; v1 submitted 31 July, 2015;
originally announced August 2015.
-
Scalable background-limited polarization-sensitive detectors for mm-wave applications
Authors:
Karwan Rostem,
Aamir Ali,
John W. Appel,
Charles L. Bennett,
David T. Chuss,
Felipe A. Colazo,
Erik Crowe,
Kevin L. Denis,
Tom Essinger-Hileman,
Tobias A. Marriage,
Samuel H. Moseley,
Thomas R. Stevenson,
Deborah W. Towner,
Kongpop U-Yen,
Edward J. Wollack
Abstract:
We report on the status and development of polarization-sensitive detectors for millimeter-wave applications. The detectors are fabricated on single-crystal silicon, which functions as a low-loss dielectric substrate for the microwave circuitry as well as the supporting membrane for the Transition-Edge Sensor (TES) bolometers. The orthomode transducer (OMT) is realized as a symmetric structure and…
▽ More
We report on the status and development of polarization-sensitive detectors for millimeter-wave applications. The detectors are fabricated on single-crystal silicon, which functions as a low-loss dielectric substrate for the microwave circuitry as well as the supporting membrane for the Transition-Edge Sensor (TES) bolometers. The orthomode transducer (OMT) is realized as a symmetric structure and on-chip filters are employed to define the detection bandwidth. A hybridized integrated enclosure reduces the high-frequency THz mode set that can couple to the TES bolometers. An implementation of the detector architecture at Q-band achieves 90% efficiency in each polarization. The design is scalable in both frequency coverage, 30-300 GHz, and in number of detectors with uniform characteristics. Hence, the detectors are desirable for ground-based or space-borne instruments that require large arrays of efficient background-limited cryogenic detectors.
△ Less
Submitted 20 August, 2014;
originally announced August 2014.
-
The Cosmology Large Angular Scale Surveyor (CLASS): 38 GHz detector array of bolometric polarimeters
Authors:
John W. Appel,
Aamir Ali,
Mandana Amiri,
Derek Araujo,
Charles L. Bennett,
Fletcher Boone,
Manwei Chan,
Hsiao-Mei Cho,
David T. Chuss,
Felipe Colazo,
Erik Crowe,
Kevin Denis,
Rolando Dunner,
Joseph Eimer,
Thomas Essinger-Hileman,
Dominik Gothe,
Mark Halpern,
Kathleen Harrington,
Gene Hilton,
Gary F. Hinshaw,
Caroline Huang,
Kent Irwin,
Glenn Jones,
John Karakla,
Alan J. Kogut
, et al. (19 additional authors not shown)
Abstract:
The Cosmology Large Angular Scale Surveyor (CLASS) experiment aims to map the polarization of the Cosmic Microwave Background (CMB) at angular scales larger than a few degrees. Operating from Cerro Toco in the Atacama Desert of Chile, it will observe over 65% of the sky at 38, 93, 148, and 217 GHz. In this paper we discuss the design, construction, and characterization of the CLASS 38 GHz detector…
▽ More
The Cosmology Large Angular Scale Surveyor (CLASS) experiment aims to map the polarization of the Cosmic Microwave Background (CMB) at angular scales larger than a few degrees. Operating from Cerro Toco in the Atacama Desert of Chile, it will observe over 65% of the sky at 38, 93, 148, and 217 GHz. In this paper we discuss the design, construction, and characterization of the CLASS 38 GHz detector focal plane, the first ever Q-band bolometric polarimeter array.
△ Less
Submitted 20 August, 2014;
originally announced August 2014.
-
CLASS: The Cosmology Large Angular Scale Surveyor
Authors:
Thomas Essinger-Hileman,
Aamir Ali,
Mandana Amiri,
John W. Appel,
Derek Araujo,
Charles L. Bennett,
Fletcher Boone,
Manwei Chan,
Hsiao-Mei Cho,
David T. Chuss,
Felipe Colazo,
Erik Crowe,
Kevin Denis,
Rolando Dünner,
Joseph Eimer,
Dominik Gothe,
Mark Halpern,
Kathleen Harrington,
Gene Hilton,
Gary F. Hinshaw,
Caroline Huang,
Kent Irwin,
Glenn Jones,
John Karakla,
Alan J. Kogut
, et al. (19 additional authors not shown)
Abstract:
The Cosmology Large Angular Scale Surveyor (CLASS) is an experiment to measure the signature of a gravita-tional-wave background from inflation in the polarization of the cosmic microwave background (CMB). CLASS is a multi-frequency array of four telescopes operating from a high-altitude site in the Atacama Desert in Chile. CLASS will survey 70\% of the sky in four frequency bands centered at 38,…
▽ More
The Cosmology Large Angular Scale Surveyor (CLASS) is an experiment to measure the signature of a gravita-tional-wave background from inflation in the polarization of the cosmic microwave background (CMB). CLASS is a multi-frequency array of four telescopes operating from a high-altitude site in the Atacama Desert in Chile. CLASS will survey 70\% of the sky in four frequency bands centered at 38, 93, 148, and 217 GHz, which are chosen to straddle the Galactic-foreground minimum while avoiding strong atmospheric emission lines. This broad frequency coverage ensures that CLASS can distinguish Galactic emission from the CMB. The sky fraction of the CLASS survey will allow the full shape of the primordial B-mode power spectrum to be characterized, including the signal from reionization at low $\ell$. Its unique combination of large sky coverage, control of systematic errors, and high sensitivity will allow CLASS to measure or place upper limits on the tensor-to-scalar ratio at a level of $r=0.01$ and make a cosmic-variance-limited measurement of the optical depth to the surface of last scattering, $τ$.
△ Less
Submitted 20 August, 2014;
originally announced August 2014.
-
The Primordial Inflation Polarization Explorer (PIPER)
Authors:
Justin Lazear,
Peter A. R. Ade,
Dominic Benford,
Charles L. Bennett,
David T. Chuss,
Jessie L. Dotson,
Joseph R. Eimer,
Dale J. Fixsen,
Mark Halpern,
Gene Hilton,
James Hinderks,
Gary F. Hinshaw,
Kent Irwin,
Christine Jhabvala,
Bradley Johnson,
Alan Kogut,
Luke Lowe,
Jeff J. McMahon,
Timothy M. Miller,
Paul Mirel,
S. Harvey Moseley,
Samelys Rodriguez,
Elmer Sharp,
Johannes G. Staguhn,
Eric R. Switzer
, et al. (3 additional authors not shown)
Abstract:
The Primordial Inflation Polarization Explorer (PIPER) is a balloon-borne cosmic microwave background (CMB) polarimeter designed to search for evidence of inflation by measuring the large-angular scale CMB polarization signal. BICEP2 recently reported a detection of B-mode power corresponding to the tensor-to-scalar ratio r = 0.2 on ~2 degree scales. If the BICEP2 signal is caused by inflationary…
▽ More
The Primordial Inflation Polarization Explorer (PIPER) is a balloon-borne cosmic microwave background (CMB) polarimeter designed to search for evidence of inflation by measuring the large-angular scale CMB polarization signal. BICEP2 recently reported a detection of B-mode power corresponding to the tensor-to-scalar ratio r = 0.2 on ~2 degree scales. If the BICEP2 signal is caused by inflationary gravitational waves (IGWs), then there should be a corresponding increase in B-mode power on angular scales larger than 18 degrees. PIPER is currently the only suborbital instrument capable of fully testing and extending the BICEP2 results by measuring the B-mode power spectrum on angular scales $θ$ = ~0.6 deg to 90 deg, covering both the reionization bump and recombination peak, with sensitivity to measure the tensor-to-scalar ratio down to r = 0.007, and four frequency bands to distinguish foregrounds. PIPER will accomplish this by map** 85% of the sky in four frequency bands (200, 270, 350, 600 GHz) over a series of 8 conventional balloon flights from the northern and southern hemispheres. The instrument has background-limited sensitivity provided by fully cryogenic (1.5 K) optics focusing the sky signal onto four 32x40-pixel arrays of time-domain multiplexed Transition-Edge Sensor (TES) bolometers held at 140 mK. Polarization sensitivity and systematic control are provided by front-end Variable-delay Polarization Modulators (VPMs), which rapidly modulate only the polarized sky signal at 3 Hz and allow PIPER to instantaneously measure the full Stokes vector (I, Q, U, V) for each pointing. We describe the PIPER instrument and progress towards its first flight.
△ Less
Submitted 9 July, 2014;
originally announced July 2014.
-
Impedance Matched Absorptive Thermal Blocking Filters
Authors:
E. J. Wollack,
D. T. Chuss,
K. Rostem,
K. U-Yen
Abstract:
We have designed, fabricated and characterized absorptive thermal blocking filters for cryogenic microwave applications. The transmission line filter's input characteristic impedance is designed to match $50\,Ω$ and its response has been validated from 0-to-50\,GHz. The observed return loss in the 0-to-20\,GHz design band is greater than $20\,$dB and shows graceful degradation with frequency. Desi…
▽ More
We have designed, fabricated and characterized absorptive thermal blocking filters for cryogenic microwave applications. The transmission line filter's input characteristic impedance is designed to match $50\,Ω$ and its response has been validated from 0-to-50\,GHz. The observed return loss in the 0-to-20\,GHz design band is greater than $20\,$dB and shows graceful degradation with frequency. Design considerations and equations are provided that enable this approach to be scaled and modified for use in other applications.
△ Less
Submitted 12 March, 2014;
originally announced March 2014.
-
Variable-delay Polarization Modulators for Cryogenic Millimeter-wave Applications
Authors:
David T. Chuss,
Joseph R. Eimer,
Dale J. Fixsen,
James Hinderks,
Alan J. Kogut,
Justin Lazear,
Paul Mirel,
Eric Switzer,
George M. Voellmer,
Edward J. Wollack
Abstract:
We describe the design, construction, and initial validation of the variable-delay polarization modulator (VPM) designed for the PIPER cosmic microwave background polarimeter. The VPM modulates between linear and circular polarization by introducing a variable phase delay between orthogonal linear polarizations. Each VPM has a diameter of 39 cm and is engineered to operate in a cryogenic environme…
▽ More
We describe the design, construction, and initial validation of the variable-delay polarization modulator (VPM) designed for the PIPER cosmic microwave background polarimeter. The VPM modulates between linear and circular polarization by introducing a variable phase delay between orthogonal linear polarizations. Each VPM has a diameter of 39 cm and is engineered to operate in a cryogenic environment (1.5 K). We describe the mechanical design and performance of the kinematic double-blade flexure and drive mechanism along with the construction of the high precision wire grid polarizers.
△ Less
Submitted 28 May, 2014; v1 submitted 6 March, 2014;
originally announced March 2014.
-
Precision control of thermal transport in cryogenic single-crystal silicon devices
Authors:
Karwan Rostem,
David T. Chuss,
Felipe A. Colazo,
Erik J. Crowe,
Kevin L. Denis,
Nathan P. Lourie,
Samuel H. Moseley,
Thomas R. Stevenson,
Edward J. Wollack
Abstract:
We report on the diffusive-ballistic thermal conductance of multi-moded single-crystal silicon beams measured below 1 K. It is shown that the phonon mean-free-path $\ell$ is a strong function of the surface roughness characteristics of the beams. This effect is enhanced in diffuse beams with lengths much larger than $\ell$, even when the surface is fairly smooth, 5-10 nm rms, and the peak thermal…
▽ More
We report on the diffusive-ballistic thermal conductance of multi-moded single-crystal silicon beams measured below 1 K. It is shown that the phonon mean-free-path $\ell$ is a strong function of the surface roughness characteristics of the beams. This effect is enhanced in diffuse beams with lengths much larger than $\ell$, even when the surface is fairly smooth, 5-10 nm rms, and the peak thermal wavelength is 0.6 $μ$m. Resonant phonon scattering has been observed in beams with a pitted surface morphology and characteristic pit depth of 30 nm. Hence, if the surface roughness is not adequately controlled, the thermal conductance can vary significantly for diffuse beams fabricated across a wafer. In contrast, when the beam length is of order $\ell$, the conductance is dominated by ballistic transport and is effectively set by the beam area. We have demonstrated a uniformity of $\pm$8% in fractional deviation for ballistic beams, and this deviation is largely set by the thermal conductance of diffuse beams that support the micro-electro-mechanical device and electrical leads. In addition, we have found no evidence for excess specific heat in single-crystal silicon membranes. This allows for the precise control of the device heat capacity with normal metal films. We discuss the results in the context of the design and fabrication of large-format arrays of far-infrared and millimeter wavelength cryogenic detectors.
△ Less
Submitted 5 March, 2014;
originally announced March 2014.
-
The Submillimeter Polarization Spectrum of M17
Authors:
Lingzhen Zeng,
Charles L. Bennett,
Nicholas L. Chapman,
David T. Chuss,
Izaskun Jimenez-Serra,
Giles Novak,
John E. Vaillancourt
Abstract:
We present 450 μm polarimetric observations of the M17 molecular cloud obtained with the SHARP polarimeter at the Caltech Submillimeter Observatory. Across the observed region, the magnetic field orientation is consistent with previous submillimeter and far-infrared polarization measurements. Our observations are centered on a region of the molecular cloud that has been compressed by stellar winds…
▽ More
We present 450 μm polarimetric observations of the M17 molecular cloud obtained with the SHARP polarimeter at the Caltech Submillimeter Observatory. Across the observed region, the magnetic field orientation is consistent with previous submillimeter and far-infrared polarization measurements. Our observations are centered on a region of the molecular cloud that has been compressed by stellar winds from a cluster of OB stars. We have compared these new data with previous 350 μm polarimetry and find an anti-correlation between the 450 to 350 μm polarization magnitude ratio and the ratio of 21 cm to 450 μm intensity. The polarization ratio is lower near the east end of the studied region where the cloud is exposed to stellar winds and radiation. At the west end of the region, the polarization ratio is higher. We interpret the varying polarization spectrum as evidence supporting the radiative alignment torque (RAT) model for grain alignment, implying higher alignment efficiency in the region that is exposed to a higher anisotropic radiation field.
△ Less
Submitted 13 June, 2013;
originally announced June 2013.
-
A waveguide-coupled thermally-isolated radiometric source
Authors:
Karwan Rostem,
David T. Chuss,
Nathan P. Lourie,
George M. Voellmer,
Edward J. Wollack
Abstract:
The design and validation of a dual polarization source for waveguide-coupled millimeter and sub-millimeter wave cryogenic sensors is presented. The thermal source is a waveguide mounted absorbing conical dielectric taper. The absorber is thermally isolated with a kinematic suspension that allows the guide to be heat sunk to the lowest bath temperature of the cryogenic system. This approach enable…
▽ More
The design and validation of a dual polarization source for waveguide-coupled millimeter and sub-millimeter wave cryogenic sensors is presented. The thermal source is a waveguide mounted absorbing conical dielectric taper. The absorber is thermally isolated with a kinematic suspension that allows the guide to be heat sunk to the lowest bath temperature of the cryogenic system. This approach enables the thermal emission from the metallic waveguide walls to be subdominant to that from the source. The use of low thermal conductivity Kevlar threads for the kinematic mount effectively decouples the absorber from the sensor cold stage. Hence, the absorber can be heated to significantly higher temperatures than the sensor with negligible conductive loading. The kinematic suspension provides high mechanical repeatability and reliability with thermal cycling. A 33-50 GHz blackbody source demonstrates an emissivity of 0.999 over the full waveguide band where the dominant deviation from unity arrises from the waveguide ohmic loss. The observed thermal time constant of the source is 40 s when the absorber temperature is 15 K. The specific heat of the lossy dielectric MF-117 is well approximated by $C_v(T)=0.12\,T\,^{2.06}$ mJ g$^{-1}$ K$^{-1}$ between 3.5 K and 15 K.
△ Less
Submitted 21 March, 2013;
originally announced March 2013.
-
The Cosmology Large Angular Scale Surveyor (CLASS): 40 GHz optical design
Authors:
Joseph R. Eimer,
Charles L. Bennett,
David T. Chuss,
Tobias A. Marriage,
Edward J. Wollack,
Lingzhen Zeng
Abstract:
The Cosmology Large Angular Scale Surveyor (CLASS) instrument will measure the polarization of the cosmic microwave background at 40, 90, and 150 GHz from Cerro Toco in the Atacama desert of northern Chile. In this paper, we describe the optical design of the 40 GHz telescope system. The telescope is a diffraction limited catadioptric design consisting of a front-end Variable-delay Polarization Mo…
▽ More
The Cosmology Large Angular Scale Surveyor (CLASS) instrument will measure the polarization of the cosmic microwave background at 40, 90, and 150 GHz from Cerro Toco in the Atacama desert of northern Chile. In this paper, we describe the optical design of the 40 GHz telescope system. The telescope is a diffraction limited catadioptric design consisting of a front-end Variable-delay Polarization Modulator (VPM), two ambient temperature mirrors, two cryogenic dielectric lenses, thermal blocking filters, and an array of 36 smooth-wall scalar feedhorn antennas. The feed horns guide the signal to antenna-coupled transition-edge sensor (TES) bolometers. Polarization diplexing and bandpass definition are handled on the same microchip as the TES. The feed horn beams are truncated with 10 dB edge taper by a 4 K Lyot-stop to limit detector loading from stray light and control the edge illumination of the front-end VPM. The field-of-view is 19deg x 14deg with a resolution for each beam on the sky of 1.5deg FWHM.
△ Less
Submitted 31 October, 2012;
originally announced November 2012.
-
A Translational Polarization Rotator
Authors:
David T. Chuss,
Edward J. Wollack,
Giampaolo Pisano,
Sheridan Ackiss,
Kongpop U-Yen,
Ming wah Ng
Abstract:
We explore a free-space polarization modulator in which a variable phase introduction between right- and left-handed circular polarization components is used to rotate the linear polarization of the outgoing beam relative to that of the incoming beam. In this device, the polarization states are separated by a circular polarizer that consists of a quarter-wave plate in combination with a wire grid.…
▽ More
We explore a free-space polarization modulator in which a variable phase introduction between right- and left-handed circular polarization components is used to rotate the linear polarization of the outgoing beam relative to that of the incoming beam. In this device, the polarization states are separated by a circular polarizer that consists of a quarter-wave plate in combination with a wire grid. A movable mirror is positioned behind and parallel to the circular polarizer. As the polarizer-mirror distance is separated, an incident linear polarization will be rotated through an angle that is proportional to the introduced phase delay. We demonstrate a prototype device that modulates Stokes Q and U over a 20% bandwidth, from 77 to 94 GHz.
△ Less
Submitted 10 August, 2012; v1 submitted 11 June, 2012;
originally announced June 2012.
-
Vector Reflectometry in a Beam Waveguide
Authors:
Joseph R. Eimer,
Charles L. Bennett,
David T. Chuss,
Edward J. Wollack
Abstract:
We present a one-port calibration technique for characterization of beam waveguide components with a vector network analyzer. This technique involves using a set of known delays to separate the responses of the instrument and the device under test. We demonstrate this technique by measuring the reflected performance of a millimeter-wave variable-delay polarization modulator.
We present a one-port calibration technique for characterization of beam waveguide components with a vector network analyzer. This technique involves using a set of known delays to separate the responses of the instrument and the device under test. We demonstrate this technique by measuring the reflected performance of a millimeter-wave variable-delay polarization modulator.
△ Less
Submitted 12 July, 2011;
originally announced July 2011.
-
Properties of a Variable-delay Polarization Modulator
Authors:
David T. Chuss,
Edward J. Wollack,
Ross Henry,
Howard Hui,
Aaron J. Juarez,
Megan Krejny,
S. Harvey Moseley,
Giles Novak
Abstract:
We investigate the polarization modulation properties of a variable-delay polarization modulator (VPM). The VPM modulates polarization via a variable separation between a polarizing grid and a parallel mirror. We find that in the limit where the wavelength is much larger than the diameter of the metal wires that comprise the grid, the phase delay derived from the geometric separation between the m…
▽ More
We investigate the polarization modulation properties of a variable-delay polarization modulator (VPM). The VPM modulates polarization via a variable separation between a polarizing grid and a parallel mirror. We find that in the limit where the wavelength is much larger than the diameter of the metal wires that comprise the grid, the phase delay derived from the geometric separation between the mirror and the grid is sufficient to characterize the device. However, outside of this range, additional parameters describing the polarizing grid geometry must be included to fully characterize the modulator response. In this paper, we report test results of a VPM at wavelengths of 350 microns and 3 mm. Electromagnetic simulations of wire grid polarizers were performed and are summarized using a simple circuit model that incorporates the loss and polarization properties of the device.
△ Less
Submitted 6 September, 2011; v1 submitted 29 June, 2011;
originally announced June 2011.
-
The Primordial Inflation Explorer (PIXIE): A Nulling Polarimeter for Cosmic Microwave Background Observations
Authors:
A. Kogut,
D. J. Fixsen,
D. T. Chuss,
J. Dotson,
E. Dwek,
M. Halpern,
G. F. Hinshaw,
S. M. Meyer,
S. H. Moseley,
M. D. Seiffert,
D. N. Spergel,
E. J. Wollack
Abstract:
The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission to measure the gravity-wave signature of primordial inflation through its distinctive imprint on the linear polarization of the cosmic microwave background. The instrument consists of a polarizing Michelson interferometer configured as a nulling polarimeter to measure the difference spectrum between orthogonal linear polarizati…
▽ More
The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission to measure the gravity-wave signature of primordial inflation through its distinctive imprint on the linear polarization of the cosmic microwave background. The instrument consists of a polarizing Michelson interferometer configured as a nulling polarimeter to measure the difference spectrum between orthogonal linear polarizations from two co-aligned beams. Either input can view the sky or a temperature-controlled absolute reference blackbody calibrator. PIXIE will map the absolute intensity and linear polarization (Stokes I, Q, and U parameters) over the full sky in 400 spectral channels spanning 2.5 decades in frequency from 30 GHz to 6 THz (1 cm to 50 um wavelength). Multi-moded optics provide background-limited sensitivity using only 4 detectors, while the highly symmetric design and multiple signal modulations provide robust rejection of potential systematic errors. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r < 10^{-3} at 5 standard deviations. The rich PIXIE data set will also constrain physical processes ranging from Big Bang cosmology to the nature of the first stars to physical conditions within the interstellar medium of the Galaxy.
△ Less
Submitted 10 May, 2011;
originally announced May 2011.
-
Far-infrared polarimetry from the Stratospheric Observatory for Infrared Astronomy
Authors:
J. E. Vaillancourt,
D. T. Chuss,
R. M. Crutcher,
J. L. Dotson,
C. D. Dowell,
D. A. Harper,
R. H. Hildebrand,
T. J. Jones,
A. Lazarian,
G. Novak,
M. W. Werner
Abstract:
Multi-wavelength imaging polarimetry at far-infrared wavelengths has proven to be an excellent tool for studying the physical properties of dust, molecular clouds, and magnetic fields in the interstellar medium. Although these wavelengths are only observable from airborne or space-based platforms, no first-generation instrument for the Stratospheric Observatory for Infrared Astronomy (SOFIA) is…
▽ More
Multi-wavelength imaging polarimetry at far-infrared wavelengths has proven to be an excellent tool for studying the physical properties of dust, molecular clouds, and magnetic fields in the interstellar medium. Although these wavelengths are only observable from airborne or space-based platforms, no first-generation instrument for the Stratospheric Observatory for Infrared Astronomy (SOFIA) is presently designed with polarimetric capabilities. We study several options for upgrading the High-resolution Airborne Wideband Camera (HAWC) to a sensitive FIR polarimeter. HAWC is a 12 x 32 pixel bolometer camera designed to cover the 53 - 215 micron spectral range in 4 colors, all at diffraction-limited resolution (5 - 21 arcsec). Upgrade options include: (1) an external set of optics which modulates the polarization state of the incoming radiation before entering the cryostat window; (2) internal polarizing optics; and (3) a replacement of the current detector array with two state-of-the-art superconducting bolometer arrays, an upgrade of the HAWC camera as well as polarimeter. We discuss a range of science studies which will be possible with these upgrades including magnetic fields in star-forming regions and galaxies and the wavelength-dependence of polarization.
△ Less
Submitted 19 November, 2007;
originally announced November 2007.
-
Diffraction Considerations for Planar Detectors in the Few-Mode Limit
Authors:
David T. Chuss,
Edward J. Wollack,
S. Harvey Moseley,
Stafford Withington,
George Saklatvala
Abstract:
Filled arrays of bolometers are currently being employed for use in astronomy from the far-infrared through millimeter parts of the electromagnetic spectrum. Because of the large range of wavelengths for which such detectors are applicable, the number of modes supported by a pixel will vary according to the specific application of a given available technology. We study the dependence of image fi…
▽ More
Filled arrays of bolometers are currently being employed for use in astronomy from the far-infrared through millimeter parts of the electromagnetic spectrum. Because of the large range of wavelengths for which such detectors are applicable, the number of modes supported by a pixel will vary according to the specific application of a given available technology. We study the dependence of image fidelity and induced polarization on the size of the pixel by employing a formalism in which diffraction due to the pixel boundary is treated by propagating the second-order statistical correlations of the radiation field through a model optical system. We construct polarized beam pattern images of square pixels for various ratios of p/λwhere p is the pixel size and λis the wavelength of the radiation under consideration. For the limit in which few modes are supported by the pixel (p/λ<1), we find that the diffraction due to the pixel edges is non-negligible and hence must be considered along with the telescope diffraction pattern in modeling the ultimate spatial resolution of an imaging system. For the case in which the pixel is over-moded (p/λ>1), the geometric limit is approached as expected. This technique gives a quantitative approach to optimize the imaging properties of arrays of planar detectors in the few-mode limit.
△ Less
Submitted 28 February, 2007;
originally announced February 2007.
-
PAPPA: Primordial Anisotropy Polarization Pathfinder Array
Authors:
A. Kogut,
D. T. Chuss,
D. Fixsen,
G. F. Hinshaw,
M. Limon,
S. H. Moseley,
N. Phillips,
E. Sharp,
E. J. Wollack,
K. U-Yen,
N. Cao,
T. Stevenson,
W. Hsieh,
M. Devlin,
S. Dicker,
C. Semisch,
K. Irwin
Abstract:
The Primordial Anisotropy Polarization Pathfinder Array (PAPPA) is a balloon-based instrument to measure the polarization of the cosmic microwave background and search for the signal from gravity waves excited during an inflationary epoch in the early universe. PAPPA will survey a 20 x 20 deg patch at the North Celestial Pole using 32 pixels in 3 passbands centered at 89, 212, and 302 GHz. Each…
▽ More
The Primordial Anisotropy Polarization Pathfinder Array (PAPPA) is a balloon-based instrument to measure the polarization of the cosmic microwave background and search for the signal from gravity waves excited during an inflationary epoch in the early universe. PAPPA will survey a 20 x 20 deg patch at the North Celestial Pole using 32 pixels in 3 passbands centered at 89, 212, and 302 GHz. Each pixel uses MEMS switches in a superconducting microstrip transmission line to combine the phase modulation techniques used in radio astronomy with the sensitivity of transition-edge superconducting bolometers. Each switched circuit modulates the incident polarization on a single detector, allowing nearly instantaneous characterization of the Stokes I, Q, and U parameters. We describe the instrument design and status.
△ Less
Submitted 19 September, 2006;
originally announced September 2006.
-
Results of SPARO 2003: Map** Magnetic Fields in Giant Molecular Clouds
Authors:
H. Li,
G. S. Griffin,
M. Krejny,
G. Novak,
R. F. Loewenstein,
M. G. Newcomb,
P. G. Calisse,
D. T. Chuss
Abstract:
We present results from the Austral Winter 2003 observing campaign of SPARO, a 450 micron polarimeter used with a two-meter telescope at South Pole. We mapped large-scale magnetic fields in four Giant Molecular Clouds (GMCs) in the Galactic disk: NGC 6334, the Carina Nebula, G333.6-0.2 and G331.5-0.1. We find a statistically significant correlation of the inferred field directions with the orien…
▽ More
We present results from the Austral Winter 2003 observing campaign of SPARO, a 450 micron polarimeter used with a two-meter telescope at South Pole. We mapped large-scale magnetic fields in four Giant Molecular Clouds (GMCs) in the Galactic disk: NGC 6334, the Carina Nebula, G333.6-0.2 and G331.5-0.1. We find a statistically significant correlation of the inferred field directions with the orientation of the Galactic plane. Specifically, three of the four GMCs (NGC 6334 is the exception) have mean field directions that are within 15 degrees of the plane. The simplest interpretation is that the field direction tends to be preserved during the process of GMC formation. We have also carried out an analysis of published optical polarimetry data. For the closest of the SPARO GMCs, NGC 6334, we can compare the field direction in the cloud as measured by SPARO with the field direction in a larger region surrounding the cloud, as determined from optical polarimetry. For purposes of comparison, we also use optical polarimetry to determine field directions for other regions of similar size and distance. Overall, the results from this optical polarimetry analysis are consistent with our suggestion that field direction tends to be preserved during GMC formation. Finally, we compare the disorder in our magnetic field maps with the disorder seen in magnetic field maps derived from MHD turbulence simulations. We conclude from these comparisons that the magnetic energy density in our clouds is comparable to the turbulent energy density.
△ Less
Submitted 21 February, 2006;
originally announced February 2006.
-
Map** Magnetic Fields in the Cold Dust at the Galactic Center
Authors:
David T. Chuss,
Giles Novak,
Roger H. Hildebrand,
C. Darren Dowell,
John E. Vaillancourt,
Jaqueline A. Davidson,
Jessie L. Dotson
Abstract:
We report the detection of polarized emission in the vicinity of the Galactic center for 158 positions within eight different pointings of the Hertz polarimeter operating on the Caltech Submillimeter Observatory. These pointings include positions 2 arcminutes offset to the E, NE, and NW of M-0.02-0.07; positions to the SE and NW of the 20 km/s cloud (M-0.13-0.08), CO+0.02-0.02, M+0.07-0.08, and…
▽ More
We report the detection of polarized emission in the vicinity of the Galactic center for 158 positions within eight different pointings of the Hertz polarimeter operating on the Caltech Submillimeter Observatory. These pointings include positions 2 arcminutes offset to the E, NE, and NW of M-0.02-0.07; positions to the SE and NW of the 20 km/s cloud (M-0.13-0.08), CO+0.02-0.02, M+0.07-0.08, and M+0.11-0.08. We use these data in conjunction with previous far-infrared and submillimeter polarization results to find that the direction of the inferred magnetic field is related to the density of the molecular material in the following way: in denser regions, the field is generally parallel to the Galactic plane, whereas in regions with lower densities, the field is generally perpendicular to the plane. This finding is consistent with a model in which an initially poloidal field has been sheared into a toroidal configuration in regions that are dense enough such that the gravitational energy density is greater than the energy density of the magnetic field. Using this model, we estimate the characteristic strength of the magnetic field in the central 30 pc of our Galaxy to be a few mG.
△ Less
Submitted 3 January, 2003;
originally announced January 2003.
-
First Results from SPARO: Evidence for Large-Scale Toroidal Magnetic Fields in the Galactic Center
Authors:
G. Novak,
D. T. Chuss,
T. Renbarger,
G. S. Griffin,
M. G. Newcomb,
J. B. Peterson,
R. F. Loewenstein,
D. Pernic,
J. L. Dotson
Abstract:
We have observed the linear polarization of 450 micron continuum emission from the Galactic center, using a new polarimetric detector system that is operated on a 2 m telescope at the South Pole. The resulting polarization map extends ~ 170 pc along the Galactic plane and ~ 30 pc in Galactic latitude, and thus covers a significant fraction of the central molecular zone. Our map shows that this r…
▽ More
We have observed the linear polarization of 450 micron continuum emission from the Galactic center, using a new polarimetric detector system that is operated on a 2 m telescope at the South Pole. The resulting polarization map extends ~ 170 pc along the Galactic plane and ~ 30 pc in Galactic latitude, and thus covers a significant fraction of the central molecular zone. Our map shows that this region is permeated by large-scale toroidal magnetic fields. We consider our results together with radio observations that show evidence for poloidal fields in the Galactic center, and with Faraday rotation observations. We compare all of these observations with the predictions of a magnetodynamic model for the Galactic center that was proposed in order to explain the Galactic Center Radio Lobe as a magnetically driven gas outflow. We conclude that the observations are basically consistent with the model.
△ Less
Submitted 5 September, 2001;
originally announced September 2001.