  1. Multi-Blade detector with VMM3a-ASIC-based readout: installation and commissioning at the reflectometer Amor at PSI

    Authors: F. Piscitelli, F. Ghazi Moradi, F. S. Alves, M. J. Christensen, J. Hrivnak, A. Johansson, K. Fissum, C. C. Lai, A. Monera Martinez, D. Pfeiffer, E. Shahu, J. Stahn, P. O. Svensson

    Abstract: The Multi-Blade (MB) Boron-10-based neutron detector is the chosen technology for three instruments at the European Spallation Source (ESS): the two ESS reflectometers, ESTIA and FREIA, and the Test Beam Line. A fourth MB detector has been built, installed and commissioned for the user operation of the reflectometer Amor at PSI (Switzerland). Amor can be considered a downscaled version of the ESS… ▽ More

    Submitted 18 March, 2024; v1 submitted 13 February, 2024; originally announced February 2024.

    Comments: 16 pages, 12 figures

    Journal ref: 2024 JINST 19 P05010

  2. Rate-capability of the VMM3a Front End in the RD51 Scalable Readout System

    Authors: D. Pfeiffer, L. Scharenberg, P. Schwäbig, S. Alcock, F. Brunbauer, M. J. Christensen, K. Desch, K. Flöthner, F. Garcia, R. Hall-Wilton, M. Hracek, G. Iakovidis, D. Janssens, J. Kaminski, M. Lupberger, H. Muller, E. Oliveri, L. Ropelewski, A. Rusu, J. Samarati, M. van Stenis, A. Utrobicic, R. Veenhof

    Abstract: The VMM3a is an Application Specific Integrated Circuit (ASIC), specifically developed for the readout of gaseous detectors. Originally developed within the ATLAS New Small Wheel (NSW) upgrade, it has been successfully integrated into the Scalable Readout System (SRS) of the RD51 collaboration. This allows, to use the VMM3a also in small laboratory set-ups and mid-scale experiments, which make use… ▽ More

    Submitted 2 February, 2022; v1 submitted 21 September, 2021; originally announced September 2021.

  3. arXiv:2010.06347  [pdf, other

    physics.ins-det nucl-ex

    Response of a Li-glass/multi-anode photomultiplier detector to collimated thermal-neutron beams

    Authors: E. Rofors, N. Mauritzson, H. Perrey, R. Al Jebali, J. R. M. Annand, L. Boyd, M. J. Christensen, U. Clemens, S. Desert, R. Engels, K. G. Fissum, H. Frielinghaus, C. Gheorghe, R. Hall-Wilton, S. Jaksch, K. Kanaki, S. Kazi, G. Kemmerling, I. Llamas Jansa, V. Maulerova, R. Montgomery, T. Richter, J. Scherzinger, B. Seitz, M. Shetty

    Abstract: The response of a position-sensitive Li-glass scintillator detector being developed for thermal-neutron detection with 6 mm position resolution has been investigated using collimated beams of thermal neutrons. The detector was moved perpendicularly through the neutron beams in 0.5 to 1.0 mm horizontal and vertical steps. Scintillation was detected in an 8 X 8 pixel multi-anode photomultiplier tube… ▽ More

    Submitted 9 December, 2020; v1 submitted 13 October, 2020; originally announced October 2020.

    Comments: 23 pages, 8 figures

  4. arXiv:2005.08675  [pdf, other

    physics.ins-det nucl-ex

    Response of a Li-glass/multi-anode photomultiplier detector to focused proton and deuteron beams

    Authors: E. Rofors, J. Pallon, R. Al Jebali, J. R. M. Annand, L. Boyd, M. J. Christensen, U. Clemens, S. Desert, M. Elfman, R. Engels, K. G. Fissum, H. Frielinghaus, R. Frost, S. Gardner, C. Gheorghe, R. Hall-Wilton, S. Jaksch, K. Kanaki, G. Kemmerling, P. Kristiansson, K. Livingston, V. Maulerova, N. Mauritzson, R. Montgomery, H. Perrey , et al. (4 additional authors not shown)

    Abstract: The response of a position-sensitive Li-glass based scintillation detector to focused beams of 2.5 MeV protons and deuterons has been investigated. The beams were scanned across the detector in 0.5 mm horizontal and vertical steps perpendicular to the beams. Scintillation light was registered using an 8 by 8 pixel multi-anode photomultiplier tube. The signal amplitudes were recorded for each pixel… ▽ More

    Submitted 18 May, 2020; originally announced May 2020.

    Comments: 22 pages, 8 figures, to be submitted to Nucl. Instr. and Meth. in Phys. Res. A

  5. The Multi-Blade Boron-10-based neutron detector performance using a focusing reflectometer

    Authors: G. Mauri, I. Apostolidis, M. J. Christensen, A. Glavic, C. C. Lai, A. Laloni, F. Messi, A. Lindh Olsson, L. Robinson, J. Stahn, P. O. Svensson, R. Hall-Wilton, F. Piscitelli

    Abstract: The Multi-Blade is a Boron-10-based neutron detector designed for neutron reflectometers and developed for the two instruments (Estia and FREIA) planned for the European Spallation Source in Sweden. A reflectometry demonstrator has been installed at the AMOR reflectometer at the Paul Scherrer Institut (PSI - Switzerland). The setup exploits the Selene guide concept and it can be considered a scale… ▽ More

    Submitted 9 January, 2020; originally announced January 2020.

    Comments: 32 pages, 28 figures

    Journal ref: Journal of Instrumentation 15, P03010, (2020)

  6. Architecture of the data aggregation and streaming system for the European Spallation Source neutron instrument suite

    Authors: A. H. C. Mukai, M. J. Clarke, M. J. Christensen, J. M. C. Nilsson, M. G. Shetty, M. Brambilla, D. Werder, M. Könnecke, J. Harper, M. D. Jones, F. A. Akeroyd, C. Reis, G. Kourousias, T. S. Richter

    Abstract: The European Spallation Source (ESS) will provide long neutron pulses for experiments on a suite of different instruments. Most of these will perform neutron data acquisition in event mode, i.e. each detected neutron will be characterised by one absolute timestamp and pixel identifier pair. Slow controls metadata from EPICS, such as sample environment measurements and motor positions, will also be… ▽ More

    Submitted 30 August, 2018; v1 submitted 26 July, 2018; originally announced July 2018.

    Comments: Corrected typos; addressed revision requests: added more details about event sizes, added discussion on generic versus specific applications, added information about the Event Formation Unit's event schema, added more information on performance tests and added reference

  7. Software-based data acquisition and processing for neutron detectors at European Spallation Source - early experience from four detector designs

    Authors: M. J. Christensen, R. Al Jebali, T. Blum, R. Hall-Wilton, A. Khaplanov, M. Lupberger, F. Messi, A. Mukai, J. Nilsson, D. Pfeiffer, F. Piscitelli, T. Richter, M. Shetty, S. Skelboe, C. Søgaard

    Abstract: European Spallation Source (ESS) will deliver neutrons at high flux for use in diverse neutron scattering techniques. The neutron source facility and the scientific instruments will be located in Lund, and the Data Management and Software Centre (DMSC), in Copenhagen. A number of detector prototypes are being developed at ESS together with its European in-kind partners, for example: SoNDe, Multi-G… ▽ More

    Submitted 22 October, 2018; v1 submitted 11 July, 2018; originally announced July 2018.

    Comments: 26 pages

  8. arXiv:1706.00333  [pdf, other

    physics.ins-det cs.NI

    Achieveing reliable UDP transmission at 10 Gb/s using BSD socket for data acquisition systems

    Authors: Morten Jagd Christensen, Tobias Richter

    Abstract: User Datagram Protocol (UDP) is a commonly used protocol for data transmission in small embedded systems. UDP as such is unreliable and packet losses can occur. The achievable data rates can suffer if optimal packet sizes are not used. The alternative, Transmission Control Protocol (TCP) guarantees the ordered delivery of data and automatically adjusts transmission to match the capability of the t… ▽ More

    Submitted 17 April, 2020; v1 submitted 1 June, 2017; originally announced June 2017.

    Comments: 12 pages, 3 figures, technical report