Skip to main content

Showing 1–11 of 11 results for author: Chipaux, R

.
  1. arXiv:2211.13489  [pdf, other

    astro-ph.IM astro-ph.HE

    The Scientific Performance of the Microchannel X-ray Telescope on board the SVOM Mission

    Authors: D. Gotz, M. Boutelier, V. Burwitz, R. Chipaux, B. Cordier, C. Feldman, P. Ferrando, A. Fort, F. Gonzalez, A. Gros, S. Hussein, J. -M. Le Duigou, N. Meidinger, K. Mercier, A. Meuris, J. Pearson, N. Renault-Tinacci, F. Robinet, B. Schneider, R. Willingale

    Abstract: The Microchannel X-ray Telescope (MXT) will be the first focusing X-ray telescope based on a "Lobster-Eye" optical design to be flown on Sino-French mission SVOM. SVOM will be dedicated to the study of Gamma-Ray Bursts and more generally time-domain astrophysics. The MXT telescope is a compact (focal length ~ 1.15 m) and light (< 42 kg) instrument, sensitive in the 0.2--10 keV energy range. It is… ▽ More

    Submitted 24 November, 2022; originally announced November 2022.

    Comments: 22 pages, 12 figures, accepted for publication in Experimental Astronomy

  2. arXiv:1512.00305  [pdf, ps, other

    physics.ins-det astro-ph.IM nucl-ex

    Fast-neutron induced background in LaBr3:Ce detectors

    Authors: J. Kiener, V. Tatischeff, I. Deloncle, N. de Séréville, P. Laurent, C. Blondel, M. Chabot, R. Chipaux, A. Coc, S. Dubos, A. Gostojic, N. Goutev, C. Hamadache, F. Hammache, B. Horeau, O. Limousin, S. Ouichaoui, G. Prévot, R. Rodríguez-Gasén, M. S. Yavahchova

    Abstract: The response of a scintillation detector with a cylindrical 1.5-inch LaBr3:Ce crystal to incident neutrons has been measured in the energy range En = 2-12 MeV. Neutrons were produced by proton irradiation of a Li target at Ep = 5-14.6 MeV with pulsed proton beams. Using the time-of-flight information between target and detector, energy spectra of the LaBr3:Ce detector resulting from fast neutron i… ▽ More

    Submitted 1 December, 2015; originally announced December 2015.

    Comments: 28 pages, 10 figures, 4 Tables

    Journal ref: Nucl. Instr. and Meth. in Physics Research A 798, 152 (2015)

  3. arXiv:1507.00204  [pdf, other

    astro-ph.IM astro-ph.HE

    The Microchannel X-ray Telescope on Board the SVOM Satellite

    Authors: D. Gotz, C. Adami, S. Basa, V. Beckmann, V. Burwitz, R. Chipaux, B. Cordier, P. Evans, O. Godet, R. Goosmann, N. Meidinger, A. Meuris, C. Motch, K. Nandra, P. O'Brien, J. Osborne, E. Perinati, A. Rau, R. Willingale, K. Mercier, F. Gonzalez

    Abstract: We present the Micro-channel X-ray Telescope (MXT), a new narrow-field (about 1°) telescope that will be flying on the Sino-French SVOM mission dedicated to Gamma-Ray Burst science, scheduled for launch in 2021. MXT is based on square micro pore optics (MPOs), coupled with a low noise CCD. The optics are based on a "Lobster Eye" design, while the CCD is a focal plane detector similar to the type d… ▽ More

    Submitted 1 July, 2015; originally announced July 2015.

    Comments: 6 pages, 6 figures, proceedings of the conference "Swift: 10 years of Discovery", Rome, December 2-5, 2014. To be published by PoS

  4. arXiv:1505.00976  [pdf

    astro-ph.IM hep-ex

    Hard X-ray polarimetry with Caliste, a high performance CdTe based imaging spectrometer

    Authors: S. Antier, P. Ferrando, O. Limousin, E. Caroli, R. M. Curado da Silva, C. Blondel, R. Chipaux, V. Honkimaki, B. Horeau, P. Laurent, J. M. Maia, A. Meuris, S. Del Sordo, J. B. Stephen

    Abstract: Since the initial exploration of soft gamma-ray sky in the 60's, high-energy celestial sources have been mainly characterized through imaging, spectroscopy and timing analysis. Despite tremendous progress in the field, the radiation mechanisms at work in sources such as neutrons stars and black holes are still unclear. The polarization state of the radiation is an observational parameter which bri… ▽ More

    Submitted 5 May, 2015; originally announced May 2015.

    Comments: 17 pages, 14 figures, 2 tables in Experimental Astronomy, 2015

  5. Electrical-modelling, design and simulation of cumulative radiation effects in semiconductor pixels detectors: prospects and limits

    Authors: Nicolas T. Fourches, Remi Chipaux

    Abstract: Silicon detectors have gained in popularity since silicon became a widely used micro/nanoelectronic semiconductor material. Silicon detectors are used in particle physics as well as imaging for pixel based detecting systems. Over the past twenty years a lot of experimental efforts have been focused on the effects of ionizing and non-ionizing radiation on silicon pixels. Some of this research was d… ▽ More

    Submitted 19 November, 2014; v1 submitted 28 October, 2014; originally announced October 2014.

    Comments: Conference Poster, list of authors updated

    Journal ref: 2015 JINST 10 C01036

  6. arXiv:1104.1544  [pdf, other

    astro-ph.IM astro-ph.HE

    The COSPIX mission: focusing on the energetic and obscured Universe

    Authors: P. Ferrando, A. Goldwurm, P. Laurent, O. Limousin, V. Beckmann, M. Arnaud, X. Barcons, D. Bomans, I. Caballero, F. Carrera, S. Chaty, J. Chenevez, R. Chipaux, F. Christensen, A. Claret, S. Corbel, J. Croston, E. Daddi, M. De Becker, A. Decourchelle, D. Elbaz, M. Falanga, C. Ferrari, C. Feruglio, D. Götz , et al. (35 additional authors not shown)

    Abstract: Tracing the formation and evolution of all supermassive black holes, including the obscured ones, understanding how black holes influence their surroundings and how matter behaves under extreme conditions, are recognized as key science objectives to be addressed by the next generation of instruments. These are the main goals of the COSPIX proposal, made to ESA in December 2010 in the context of it… ▽ More

    Submitted 8 April, 2011; originally announced April 2011.

    Comments: 7 pages, accepted for publication in Proceedings of Science, for the 25th Texas Symposium on Relativistic Astrophysics (eds. F. Rieger &amp; C. van Eldik), PoS(Texas 2010)254

    MSC Class: 85-06

  7. arXiv:0912.4300  [pdf

    physics.ins-det hep-ex

    Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter

    Authors: The CMS Electromagnetic Calorimeter Group, P. Adzic, N. Almeida, D. Andelin, I. Anicin, Z. Antunovic, R. Arcidiacono, M. W. Arenton, E. Auffray, S. Argiro, A. Askew, S. Baccaro, S. Baffioni, M. Balazs, D. Bandurin, D. Barney, L. M. Barone, A. Bartoloni, C. Baty, S. Beauceron, K. W. Bell, C. Bernet, M. Besancon, B. Betev, R. Beuselinck , et al. (245 additional authors not shown)

    Abstract: Ensuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews t… ▽ More

    Submitted 21 December, 2009; originally announced December 2009.

    Comments: 24 pages, 19 figures, available on CMS information server at http://cms.cern.ch/iCMS/

    Report number: CMS Note 2009/016

    Journal ref: JINST 5:P03010,2010

  8. arXiv:0912.0233  [pdf, ps, other

    astro-ph.IM

    Progress and Validation of Geant4 Based Radioactive Decay Simulation Using the Examples of Simbol-X and IXO

    Authors: S. Hauf, M. Kuster, M. G. Pia, Z. Bell, U. Briel, R. Chipaux, D. H. H. Hoffmann, E. Kendziorra, P. Laurent, L. Strüder, C. Tenzer, G. Weidenspointer, A. Zoglauer

    Abstract: The anticipated high sensitivity and the science goals of the next generation X-ray space missions, like the International X-ray Observatory or Simbol-X, rely on a low instrumental background, which in turn requires optimized shielding concepts. We present Geant4 based simulation results on the IXO Wide Field Imager cosmic ray proton induced background in comparison with previous results obtaine… ▽ More

    Submitted 1 December, 2009; originally announced December 2009.

    Comments: 6 pages, 7 figures and images, to appear in proceedings of the Nuclear Science Symposium and Medical Imaging Conference 2009, Orlando

  9. arXiv:0805.3934  [pdf

    physics.ins-det

    Radiation Induced Effects in a Monolithic Active Pixel Sensor : The Mimosa8 Chip

    Authors: Nicolas Fourches, M. Besançon, R. Chipaux, Y. Li, P. Lutz, F. Orsini

    Abstract: We have studied the effects of ionizing irradiation from a 60Co source and the effects of neutron irradiation on a Monolithic Active Pixel Sensor Chip(MIMOSA8). A previous report was devoted solely to the neutron-induced effects. We show that extended defects due to the neutron damage changes the distribution of the pixels pedestals. This is mainly due to the increase of the dark generation curr… ▽ More

    Submitted 26 May, 2008; originally announced May 2008.

  10. arXiv:0802.3846  [pdf, ps, other

    astro-ph

    Simbol-X background simulation activities

    Authors: R. Chipaux, U. Briel, A. Bulgarelli, L. Foschini, E. Kendziorra, C. Klose, M. Kuster, P. Laurent, C. Tenzer

    Abstract: Using the Geant4 toolkit, a Monte-Carlo code to simulate the detector background of the Simbol-X focal plane instrument has been developed with the aim to optimize the design of the instrument. Structural design models of the mirror and detector satellites have been built and used as baseline for our simulations, to evaluate the different background contributions that must be taken into account… ▽ More

    Submitted 26 February, 2008; originally announced February 2008.

    Comments: 5 pages, 5 figures and images, to appear in proceedings of "Simbol-X: the hard X-ray Universe in focus", held in Bologna (Italy), May 14-16, 2007

  11. IDeF-X ASIC for Cd(Zn)Te spectro-imaging systems

    Authors: O. Limousin, O. Gevin, F. Lugiez, R. Chipaux, E. Delagnes, B. Dirks, B. Horeau

    Abstract: Joint progresses in Cd(Zn)Te detectors, microelectronics and interconnection technologies open the way for a new generation of instruments for physics and astrophysics applications in the energy range from 1 to 1000 keV. Even working between -20 and 20 degrees Celsius, these instruments will offer high spatial resolution (pixel size ranging from 300 x 300 square micrometers to few square millime… ▽ More

    Submitted 24 November, 2004; v1 submitted 19 November, 2004; originally announced November 2004.

    Comments: 8 pages, 11 figures, IEEE NSS-MIC conference in Rome 2004, submitted to IEEE TNS, correction in unit of figure 8