-
The Scientific Performance of the Microchannel X-ray Telescope on board the SVOM Mission
Authors:
D. Gotz,
M. Boutelier,
V. Burwitz,
R. Chipaux,
B. Cordier,
C. Feldman,
P. Ferrando,
A. Fort,
F. Gonzalez,
A. Gros,
S. Hussein,
J. -M. Le Duigou,
N. Meidinger,
K. Mercier,
A. Meuris,
J. Pearson,
N. Renault-Tinacci,
F. Robinet,
B. Schneider,
R. Willingale
Abstract:
The Microchannel X-ray Telescope (MXT) will be the first focusing X-ray telescope based on a "Lobster-Eye" optical design to be flown on Sino-French mission SVOM. SVOM will be dedicated to the study of Gamma-Ray Bursts and more generally time-domain astrophysics. The MXT telescope is a compact (focal length ~ 1.15 m) and light (< 42 kg) instrument, sensitive in the 0.2--10 keV energy range. It is…
▽ More
The Microchannel X-ray Telescope (MXT) will be the first focusing X-ray telescope based on a "Lobster-Eye" optical design to be flown on Sino-French mission SVOM. SVOM will be dedicated to the study of Gamma-Ray Bursts and more generally time-domain astrophysics. The MXT telescope is a compact (focal length ~ 1.15 m) and light (< 42 kg) instrument, sensitive in the 0.2--10 keV energy range. It is composed of an optical system, based on micro-pore optics (MPOs) of 40 micron pore size, coupled to a low-noise pnCDD X-ray detector. In this paper we describe the expected scientific performance of the MXT telescope, based on the End-to-End calibration campaign performed in fall 2021, before the integration of the SVOM payload on the satellite.
△ Less
Submitted 24 November, 2022;
originally announced November 2022.
-
Fast-neutron induced background in LaBr3:Ce detectors
Authors:
J. Kiener,
V. Tatischeff,
I. Deloncle,
N. de Séréville,
P. Laurent,
C. Blondel,
M. Chabot,
R. Chipaux,
A. Coc,
S. Dubos,
A. Gostojic,
N. Goutev,
C. Hamadache,
F. Hammache,
B. Horeau,
O. Limousin,
S. Ouichaoui,
G. Prévot,
R. Rodríguez-Gasén,
M. S. Yavahchova
Abstract:
The response of a scintillation detector with a cylindrical 1.5-inch LaBr3:Ce crystal to incident neutrons has been measured in the energy range En = 2-12 MeV. Neutrons were produced by proton irradiation of a Li target at Ep = 5-14.6 MeV with pulsed proton beams. Using the time-of-flight information between target and detector, energy spectra of the LaBr3:Ce detector resulting from fast neutron i…
▽ More
The response of a scintillation detector with a cylindrical 1.5-inch LaBr3:Ce crystal to incident neutrons has been measured in the energy range En = 2-12 MeV. Neutrons were produced by proton irradiation of a Li target at Ep = 5-14.6 MeV with pulsed proton beams. Using the time-of-flight information between target and detector, energy spectra of the LaBr3:Ce detector resulting from fast neutron interactions have been obtained at 4 different neutron energies. Neutron-induced gamma rays emitted by the LaBr3:Ce crystal were also measured in a nearby Ge detector at the lowest proton beam energy. In addition, we obtained data for neutron irradiation of a large-volume high-purity Ge detector and of a NE-213 liquid scintillator detector, both serving as monitor detectors in the experiment. Monte-Carlo type simulations for neutron interactions in the liquid scintillator, the Ge and LaBr3:Ce crystals have been performed and compared with measured data. Good agreement being obtained with the data, we present the results of simulations to predict the response of LaBr3:Ce detectors for a range of crystal sizes to neutron irradiation in the energy range En = 0.5-10 MeV
△ Less
Submitted 1 December, 2015;
originally announced December 2015.
-
The Microchannel X-ray Telescope on Board the SVOM Satellite
Authors:
D. Gotz,
C. Adami,
S. Basa,
V. Beckmann,
V. Burwitz,
R. Chipaux,
B. Cordier,
P. Evans,
O. Godet,
R. Goosmann,
N. Meidinger,
A. Meuris,
C. Motch,
K. Nandra,
P. O'Brien,
J. Osborne,
E. Perinati,
A. Rau,
R. Willingale,
K. Mercier,
F. Gonzalez
Abstract:
We present the Micro-channel X-ray Telescope (MXT), a new narrow-field (about 1°) telescope that will be flying on the Sino-French SVOM mission dedicated to Gamma-Ray Burst science, scheduled for launch in 2021. MXT is based on square micro pore optics (MPOs), coupled with a low noise CCD. The optics are based on a "Lobster Eye" design, while the CCD is a focal plane detector similar to the type d…
▽ More
We present the Micro-channel X-ray Telescope (MXT), a new narrow-field (about 1°) telescope that will be flying on the Sino-French SVOM mission dedicated to Gamma-Ray Burst science, scheduled for launch in 2021. MXT is based on square micro pore optics (MPOs), coupled with a low noise CCD. The optics are based on a "Lobster Eye" design, while the CCD is a focal plane detector similar to the type developed for the seven eROSITA telescopes. MXT is a compact and light (<35 kg) telescope with a 1 m focal length, and it will provide an effective area of about 45 cmsq on axis at 1 keV. The MXT PSF is expected to be better than 4.2 arc min (FWHM) ensuring a localization accuracy of the afterglows of the SVOM GRBs to better than 1 arc min (90\% c.l. with no systematics) provided MXT data are collected within 5 minutes after the trigger. The MXT sensitivity will be adequate to detect the afterglows for almost all the SVOM GRBs as well as to perform observations of non-GRB astrophysical objects. These performances are fully adapted to the SVOM science goals, and prove that small and light telescopes can be used for future small X-ray missions.
△ Less
Submitted 1 July, 2015;
originally announced July 2015.
-
Hard X-ray polarimetry with Caliste, a high performance CdTe based imaging spectrometer
Authors:
S. Antier,
P. Ferrando,
O. Limousin,
E. Caroli,
R. M. Curado da Silva,
C. Blondel,
R. Chipaux,
V. Honkimaki,
B. Horeau,
P. Laurent,
J. M. Maia,
A. Meuris,
S. Del Sordo,
J. B. Stephen
Abstract:
Since the initial exploration of soft gamma-ray sky in the 60's, high-energy celestial sources have been mainly characterized through imaging, spectroscopy and timing analysis. Despite tremendous progress in the field, the radiation mechanisms at work in sources such as neutrons stars and black holes are still unclear. The polarization state of the radiation is an observational parameter which bri…
▽ More
Since the initial exploration of soft gamma-ray sky in the 60's, high-energy celestial sources have been mainly characterized through imaging, spectroscopy and timing analysis. Despite tremendous progress in the field, the radiation mechanisms at work in sources such as neutrons stars and black holes are still unclear. The polarization state of the radiation is an observational parameter which brings key additional information about the physical process. This is why most of the projects for the next generation of space missions covering the tens of keV to the MeV region require a polarization measurement capability. A key element enabling this capability is a detector system allowing the identification and characterization of Compton interactions as they are the main process at play. The hard X-ray imaging spectrometer module, developed in CEA with the generic name of Caliste module, is such a detector. In this paper, we present experimental results for two types of Caliste-256 modules, one based on a CdTe crystal, the other one on a CdZnTe crystal, which have been exposed to linearly polarized beams at the European Synchrotron Radiation Facility. These results, obtained at 200-300 keV, demonstrate their capability to give an accurate determination of the polarization parameters (polarization angle and fraction) of the incoming beam. Applying a selection to our data set, equivalent to select 90 degrees Compton scattered interactions in the detector plane, we find a modulation factor Q of 0.78. The polarization angle and fraction are derived with accuracies of approximately 1 degree and 5%. The modulation factor remains larger than 0.4 when essentially no selection is made at all on the data. These results prove that the Caliste-256 modules have performances allowing them to be excellent candidates as detectors with polarimetric capabilities, in particular for future space missions.
△ Less
Submitted 5 May, 2015;
originally announced May 2015.
-
Electrical-modelling, design and simulation of cumulative radiation effects in semiconductor pixels detectors: prospects and limits
Authors:
Nicolas T. Fourches,
Remi Chipaux
Abstract:
Silicon detectors have gained in popularity since silicon became a widely used micro/nanoelectronic semiconductor material. Silicon detectors are used in particle physics as well as imaging for pixel based detecting systems. Over the past twenty years a lot of experimental efforts have been focused on the effects of ionizing and non-ionizing radiation on silicon pixels. Some of this research was d…
▽ More
Silicon detectors have gained in popularity since silicon became a widely used micro/nanoelectronic semiconductor material. Silicon detectors are used in particle physics as well as imaging for pixel based detecting systems. Over the past twenty years a lot of experimental efforts have been focused on the effects of ionizing and non-ionizing radiation on silicon pixels. Some of this research was done in the framework of high luminosity particle physics experiments, along with radiation hardness studies of basic semiconductors devices. In its simplest form the semiconductor pixel detectors reduce to a PIN or PN structure partially or totally depleted, or in some MOS and APD (Avalanche PhotoDiode) structures. Bulk or surface defects affect considerably transport of free carriers. We propose guidelines for pixel design, which will be tested through a few pixel structures. This design method includes into the design the properties of defects. The electrical properties reduce to parameters, which can be introduced in a standard simulation code to make predictive simulations. We include an analytical model for defect annealing derived from isochronal annealing experiments. The proposed method can be used to study pixels detectors with different geometrical structures and made with different semiconducting materials. Its purpose is to provide an alternative to tedious and extensive radiation tests on final fabricated detectors. This is necessary for the long-term reliability of detectors together with their radiation tolerance. A general method for pixel design is introduced and we will show how it can be used for the design of alternate to silicon (germanium) pixels.
△ Less
Submitted 19 November, 2014; v1 submitted 28 October, 2014;
originally announced October 2014.
-
The COSPIX mission: focusing on the energetic and obscured Universe
Authors:
P. Ferrando,
A. Goldwurm,
P. Laurent,
O. Limousin,
V. Beckmann,
M. Arnaud,
X. Barcons,
D. Bomans,
I. Caballero,
F. Carrera,
S. Chaty,
J. Chenevez,
R. Chipaux,
F. Christensen,
A. Claret,
S. Corbel,
J. Croston,
E. Daddi,
M. De Becker,
A. Decourchelle,
D. Elbaz,
M. Falanga,
C. Ferrari,
C. Feruglio,
D. Götz
, et al. (35 additional authors not shown)
Abstract:
Tracing the formation and evolution of all supermassive black holes, including the obscured ones, understanding how black holes influence their surroundings and how matter behaves under extreme conditions, are recognized as key science objectives to be addressed by the next generation of instruments. These are the main goals of the COSPIX proposal, made to ESA in December 2010 in the context of it…
▽ More
Tracing the formation and evolution of all supermassive black holes, including the obscured ones, understanding how black holes influence their surroundings and how matter behaves under extreme conditions, are recognized as key science objectives to be addressed by the next generation of instruments. These are the main goals of the COSPIX proposal, made to ESA in December 2010 in the context of its call for selection of the M3 mission. In addition, COSPIX, will also provide key measurements on the non thermal Universe, particularly in relation to the question of the acceleration of particles, as well as on many other fundamental questions as for example the energetic particle content of clusters of galaxies. COSPIX is proposed as an observatory operating from 0.3 to more than 100 keV. The payload features a single long focal length focusing telescope offering an effective area close to ten times larger than any scheduled focusing mission at 30 keV, an angular resolution better than 20 arcseconds in hard X-rays, and polarimetric capabilities within the same focal plane instrumentation. In this paper, we describe the science objectives of the mission, its baseline design, and its performances, as proposed to ESA.
△ Less
Submitted 8 April, 2011;
originally announced April 2011.
-
Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter
Authors:
The CMS Electromagnetic Calorimeter Group,
P. Adzic,
N. Almeida,
D. Andelin,
I. Anicin,
Z. Antunovic,
R. Arcidiacono,
M. W. Arenton,
E. Auffray,
S. Argiro,
A. Askew,
S. Baccaro,
S. Baffioni,
M. Balazs,
D. Bandurin,
D. Barney,
L. M. Barone,
A. Bartoloni,
C. Baty,
S. Beauceron,
K. W. Bell,
C. Bernet,
M. Besancon,
B. Betev,
R. Beuselinck
, et al. (245 additional authors not shown)
Abstract:
Ensuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews t…
▽ More
Ensuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews the related scientific and technological problems encountered.
△ Less
Submitted 21 December, 2009;
originally announced December 2009.
-
Progress and Validation of Geant4 Based Radioactive Decay Simulation Using the Examples of Simbol-X and IXO
Authors:
S. Hauf,
M. Kuster,
M. G. Pia,
Z. Bell,
U. Briel,
R. Chipaux,
D. H. H. Hoffmann,
E. Kendziorra,
P. Laurent,
L. Strüder,
C. Tenzer,
G. Weidenspointer,
A. Zoglauer
Abstract:
The anticipated high sensitivity and the science goals of the next generation X-ray space missions, like the International X-ray Observatory or Simbol-X, rely on a low instrumental background, which in turn requires optimized shielding concepts. We present Geant4 based simulation results on the IXO Wide Field Imager cosmic ray proton induced background in comparison with previous results obtaine…
▽ More
The anticipated high sensitivity and the science goals of the next generation X-ray space missions, like the International X-ray Observatory or Simbol-X, rely on a low instrumental background, which in turn requires optimized shielding concepts. We present Geant4 based simulation results on the IXO Wide Field Imager cosmic ray proton induced background in comparison with previous results obtained for the Simbol-X LED and HED focal plane detectors. Our results show that an improvement in mean differential background flux compared to actually operating X-ray observatories may be feasible with detectors based on DEPFET technology. In addition we present preliminary results concerning the validation of Geant4 based radioactive decay simulation in space applications as a part of the Nano5 project.
△ Less
Submitted 1 December, 2009;
originally announced December 2009.
-
Radiation Induced Effects in a Monolithic Active Pixel Sensor : The Mimosa8 Chip
Authors:
Nicolas Fourches,
M. Besançon,
R. Chipaux,
Y. Li,
P. Lutz,
F. Orsini
Abstract:
We have studied the effects of ionizing irradiation from a 60Co source and the effects of neutron irradiation on a Monolithic Active Pixel Sensor Chip(MIMOSA8). A previous report was devoted solely to the neutron-induced effects. We show that extended defects due to the neutron damage changes the distribution of the pixels pedestals. This is mainly due to the increase of the dark generation curr…
▽ More
We have studied the effects of ionizing irradiation from a 60Co source and the effects of neutron irradiation on a Monolithic Active Pixel Sensor Chip(MIMOSA8). A previous report was devoted solely to the neutron-induced effects. We show that extended defects due to the neutron damage changes the distribution of the pixels pedestals. This is mainly due to the increase of the dark generation current due to the presence of deep traps in the depleted zones of the sensors. Alternatively, the exposure to ionizing irradiation increases the pedestals in a more homogeneous way, this coming from the generation of interface states at the Si/SiO2 interface supplemented by the presence of positively charged traps in the oxides. the sensors' leakage current is then increased. We discuss the results in view of increasing the radiation-hardness of the MAPS, bearing in mind that these chips were not designed with any rad-tol layout technique.
△ Less
Submitted 26 May, 2008;
originally announced May 2008.
-
Simbol-X background simulation activities
Authors:
R. Chipaux,
U. Briel,
A. Bulgarelli,
L. Foschini,
E. Kendziorra,
C. Klose,
M. Kuster,
P. Laurent,
C. Tenzer
Abstract:
Using the Geant4 toolkit, a Monte-Carlo code to simulate the detector background of the Simbol-X focal plane instrument has been developed with the aim to optimize the design of the instrument. Structural design models of the mirror and detector satellites have been built and used as baseline for our simulations, to evaluate the different background contributions that must be taken into account…
▽ More
Using the Geant4 toolkit, a Monte-Carlo code to simulate the detector background of the Simbol-X focal plane instrument has been developed with the aim to optimize the design of the instrument. Structural design models of the mirror and detector satellites have been built and used as baseline for our simulations, to evaluate the different background contributions that must be taken into account to determine the sensitivity of the Simbol-X detectors. We work towards a simulation based background and mass model which can be used before and during the mission.
For different material compositions, material thicknesses, locations etc. the response of the instrument to the diffuse cosmic hard X-ray background and to the cosmic proton induced background have been calculated. As a result we present estimates of the background count rate expected in the low and high energy detector, and anti-coincidence rates. The effect of induced radioactivity in the detector and shielding materials and soft proton scattering in the mirror shells are also under study.
△ Less
Submitted 26 February, 2008;
originally announced February 2008.
-
IDeF-X ASIC for Cd(Zn)Te spectro-imaging systems
Authors:
O. Limousin,
O. Gevin,
F. Lugiez,
R. Chipaux,
E. Delagnes,
B. Dirks,
B. Horeau
Abstract:
Joint progresses in Cd(Zn)Te detectors, microelectronics and interconnection technologies open the way for a new generation of instruments for physics and astrophysics applications in the energy range from 1 to 1000 keV. Even working between -20 and 20 degrees Celsius, these instruments will offer high spatial resolution (pixel size ranging from 300 x 300 square micrometers to few square millime…
▽ More
Joint progresses in Cd(Zn)Te detectors, microelectronics and interconnection technologies open the way for a new generation of instruments for physics and astrophysics applications in the energy range from 1 to 1000 keV. Even working between -20 and 20 degrees Celsius, these instruments will offer high spatial resolution (pixel size ranging from 300 x 300 square micrometers to few square millimeters), high spectral response and high detection efficiency. To reach these goals, reliable, highly integrated, low noise and low power consumption electronics is mandatory. Our group is currently develo** a new ASIC detector front-end named IDeF-X, for modular spectro-imaging system based on the use of Cd(Zn)Te detectors. We present here the first version of IDeF-X which consists in a set of ten low noise charge sensitive preamplifiers (CSA). It has been processed with the standard AMS 0.35 micrometer CMOS technology. The CSA are designed to be DC coupled to detectors having a low dark current at room temperature. The various preamps implemented are optimized for detector capacitances ranging from 0.5 up to 30 pF.
△ Less
Submitted 24 November, 2004; v1 submitted 19 November, 2004;
originally announced November 2004.