Design, optimization and experimental characterization of RF injectors for high brightness electron beams and plasma acceleration
Authors:
V. Shpakov,
D. Alesini,
M. P. Anania,
M. Behtouei,
B. Buonomo,
M. Bellaveglia,
A. Biagioni,
F. Cardelli,
M. Carillo,
E. Chiadroni,
A. Cianchi,
G. Costa,
M. Del Giorno,
L. Faillace,
M. Ferrario,
M. del Franco,
G. Franzini,
M. Galletti,
L. Giannessi,
A. Giribono,
A. Liedl,
V. Lollo,
A. Mostacci,
G. Di Pirro,
L. Piersanti
, et al. (8 additional authors not shown)
Abstract:
In this article, we share our experience related to the new photo-injector commissioning at the SPARC\_LAB test facility. The new photo-injector was installed into an existing machine and our goal was not only to improve the final beam parameters themselves but to improve the machine handling in day-to-day operations as well. Thus, besides the pure beam characterization, this article contains info…
▽ More
In this article, we share our experience related to the new photo-injector commissioning at the SPARC\_LAB test facility. The new photo-injector was installed into an existing machine and our goal was not only to improve the final beam parameters themselves but to improve the machine handling in day-to-day operations as well. Thus, besides the pure beam characterization, this article contains information about the improvements, that were introduced into the new photo-injector design from the machine maintenance point of view, and the benefits, that we gained by using the new technique to assemble the gun itself.
△ Less
Submitted 12 December, 2022;
originally announced December 2022.
-
A fast tracking code for evaluating collective effects in linear accelerators
Authors:
F. Bosco,
O. Camacho,
M. Carillo,
E. Chiadroni,
L. Faillace,
A. Fukasawa,
A. Giribono,
L. Giuliano,
N. Najernik,
A. Mostacci,
L. Palumbo,
B. Spataro,
C. Vaccarezza,
J. B. Rosenzweig,
M. Migliorati
Abstract:
The demands on performance of advanced linear accelerator based facilities strongly depend on the quality of the particle beams produced by such machines. Indeed, state-of-the-art applications in photon production and high-energy physics colliders require to use very high brightness electron beams, implying the coexistence of high peak currents and small transverse emittances. In such systems, the…
▽ More
The demands on performance of advanced linear accelerator based facilities strongly depend on the quality of the particle beams produced by such machines. Indeed, state-of-the-art applications in photon production and high-energy physics colliders require to use very high brightness electron beams, implying the coexistence of high peak currents and small transverse emittances. In such systems, the nominal phase-space density may be diluted by the presence of self-induced electromagnetic fields, causing interaction among charged particles through space charge forces and the excitation of wakefields. The two sources of collective effects may both be present in significant levels, and be coupled by the strong externally applied transverse and longitudinal fields present in modern high gradient linear accelerators. Thus, beam dynamics studies investigating all relevant effects, applied and collective, are necessary to predict the operational limitations of a given instrument. Such modeling, involving a large number of computational particles, can require significant numerical resources. In this paper we present a fast tracking code which permits accurate evaluation of wakefield effects in rf linacs, while also including a simple, robust model for space-charge forces to streamline the computations. The features of such a tool are discussed in detail in this paper and comparisons with more time-intensive commonly used tracking codes or analytical models are utilized to validate the approach we introduce. In addition, the applications motivating the development of this code define unique and challenging scenarios from the perspective of beam physics. Specifically, the fast simulation framework developed in this paper aims to describe intense electron beams injected at low energy in high-gradient accelerating structures which introduce strong rf focusing as well as strong wakefield interactions.
△ Less
Submitted 12 August, 2022;
originally announced August 2022.
-
First emittance measurement of the beam-driven plasma wakefield accelerated electron beam
Authors:
V. Shpakov,
M. P. Anania,
M. Behtouei,
M. Bellaveglia,
A. Biagioni,
M. Cesarini,
E. Chiadroni,
A. Cianchi,
G. Costa,
M. Croia,
A. Del Dotto,
M. Diomede,
F. Dipace,
M. Ferrario,
M. Galletti,
A. Giribono,
A. Liedl,
V. Lollo,
L. Magnisi,
A. Mostacci,
G. Di Pirro,
L. Piersanti,
R. Pompili,
S. Romeo,
A. R. Rossi
, et al. (4 additional authors not shown)
Abstract:
Next-generation plasma-based accelerators can push electron beams to GeV energies within centimetre distances. The plasma, excited by a driver pulse, is indeed able to sustain huge electric fields that can efficiently accelerate a trailing witness bunch, which was experimentally demonstrated on multiple occasions. Thus, the main focus of the current research is being shifted towards achieving a hi…
▽ More
Next-generation plasma-based accelerators can push electron beams to GeV energies within centimetre distances. The plasma, excited by a driver pulse, is indeed able to sustain huge electric fields that can efficiently accelerate a trailing witness bunch, which was experimentally demonstrated on multiple occasions. Thus, the main focus of the current research is being shifted towards achieving a high quality of the beam after the plasma acceleration. In this letter we present beam-driven plasma wakefield acceleration experiment, where initially preformed high-quality witness beam was accelerated inside the plasma and characterized. In this experiment the witness beam quality after the acceleration was maintained on high level, with $0.2\%$ final energy spread and $3.8~μm$ resulting normalized transverse emittance after the acceleration. In this article, for the first time to our knowledge, the emittance of the PWFA beam was directly measured.
△ Less
Submitted 9 April, 2021;
originally announced April 2021.
-
Energy spread minimization in a beam-driven plasma wakefield accelerator
Authors:
R. Pompili,
M. P. Anania,
M. Behtouei,
M. Bellaveglia,
A. Biagioni,
F. G. Bisesto,
M. Cesarini,
E. Chiadroni,
A. Cianchi,
G. Costa,
M. Croia,
A. Del Dotto,
D. Di Giovenale,
M. Diomede,
F. Dipace,
M. Ferrario,
A. Giribono,
V. Lollo,
L. Magnisi,
M. Marongiu,
A. Mostacci,
G. Di Pirro,
S. Romeo,
A. R. Rossi,
J. Scifo
, et al. (4 additional authors not shown)
Abstract:
Next-generation plasma-based accelerators can push electron bunches to gigaelectronvolt energies within centimetre distances. The plasma, excited by a driver pulse, generates large electric fields that can efficiently accelerate a trailing witness bunch making possible the realization of laboratory-scale applications ranging from high-energy colliders to ultra-bright light sources. So far several…
▽ More
Next-generation plasma-based accelerators can push electron bunches to gigaelectronvolt energies within centimetre distances. The plasma, excited by a driver pulse, generates large electric fields that can efficiently accelerate a trailing witness bunch making possible the realization of laboratory-scale applications ranging from high-energy colliders to ultra-bright light sources. So far several experiments have demonstrated a significant acceleration but the resulting beam quality, especially the energy spread, is still far from state of the art conventional accelerators. Here we show the results of a beam-driven plasma acceleration experiment where we used an electron bunch as a driver followed by an ultra-short witness. The experiment demonstrates, for the first time, an innovative method to achieve an ultra-low energy spread of the accelerated witness of about 0.1%. This is an order of magnitude smaller than what has been obtained so far. The result can lead to a major breakthrough toward the optimization of the plasma acceleration process and its implementation in forthcoming compact machines for user-oriented applications.
△ Less
Submitted 2 June, 2020;
originally announced June 2020.
-
Plasma lens-based beam extraction and removal system for Plasma Wakefield Acceleration experiments
Authors:
R. Pompili,
E. Chiadroni,
A. Cianchi,
A. Del Dotto,
L. Faillace,
M. Ferrario,
P. Iovine,
M. R. Masullo
Abstract:
Plasma Wakefield Acceleration represents one of the most promising techniques able to overcome the limits of conventional RF technology and make possible the development of compact accelerators. With respect to the laser-driven schemes, the beam-driven scenario is not limited by diffraction and dephasing issues, thus it allows to achieve larger acceleration lengths. One of the most prominent drawb…
▽ More
Plasma Wakefield Acceleration represents one of the most promising techniques able to overcome the limits of conventional RF technology and make possible the development of compact accelerators. With respect to the laser-driven schemes, the beam-driven scenario is not limited by diffraction and dephasing issues, thus it allows to achieve larger acceleration lengths. One of the most prominent drawback, conversely, occurs at the end of the acceleration process and consists of removing the depleted high-charge driver while preserving the main features (emittance and peak current) of the accelerated witness bunch. Here we present a theoretical study demonstrating the possibility to reach these goals by using an innovative system consisting of an array of beam collimators and discharge-capillaries operating as active-plasma lenses. Such a system allows to extract and transport the accelerated and highly divergent witness bunch and, at the same time, provides for the removal of the driver. The study is completed by a set of numerical simulations conducted for different beam configurations. The physics of the interaction of particles with collimator is also investigated.
△ Less
Submitted 6 September, 2019; v1 submitted 3 September, 2019;
originally announced September 2019.
-
Longitudinal phase-space manipulation with beam-driven plasma wakefields
Authors:
V. Shpakov,
M. P. Anania,
M. Bellaveglia,
A. Biagioni,
F. Bisesto,
F. Cardelli,
M. Cesarini,
E. Chiadroni,
A. Cianchi,
G. Costa,
M. Croia,
A. DelDotto,
D. DiGiovenale,
M. Diomede,
M. Ferrario,
F. Filippi,
A. Giribono,
V. Lollo,
M. Marongiu,
V. Martinelli,
A. Mostacci,
L. Piersanti,
G. DiPirro,
R. Pompili,
S. Romeo
, et al. (4 additional authors not shown)
Abstract:
The development of compact accelerator facilities providing high-brightness beams is one of the most challenging tasks in field of next-generation compact and cost affordable particle accelerators, to be used in many fields for industrial, medical and research applications. The ability to shape the beam longitudinal phase-space, in particular, plays a key role to achieve high-peak brightness. Here…
▽ More
The development of compact accelerator facilities providing high-brightness beams is one of the most challenging tasks in field of next-generation compact and cost affordable particle accelerators, to be used in many fields for industrial, medical and research applications. The ability to shape the beam longitudinal phase-space, in particular, plays a key role to achieve high-peak brightness. Here we present a new approach that allows to tune the longitudinal phase-space of a high-brightness beam by means of a plasma wakefields. The electron beam passing through the plasma drives large wakefields that are used to manipulate the time-energy correlation of particles along the beam itself. We experimentally demonstrate that such solution is highly tunable by simply adjusting the density of the plasma and can be used to imprint or remove any correlation onto the beam. This is a fundamental requirement when dealing with largely time-energy correlated beams coming from future plasma accelerators.
△ Less
Submitted 21 February, 2019;
originally announced February 2019.
-
Strong nonlinear terahertz response induced by Dirac surface states in Bi2Se3 Topological Insulator
Authors:
Flavio Giorgianni,
Enrica Chiadroni,
Andrea Rovere,
Mariangela Cestelli-Guidi,
Andrea Perucchi,
Marco Bellaveglia,
Michele Castellano,
Domenico Di Giovenale,
Giampiero Di Pirro,
Massimo Ferrario,
Riccardo Pompili,
Cristina Vaccarezza,
Fabio Villa,
Alessandro Cianchi,
Andrea Mostacci,
Massimo Petrarca,
Matthew Brahlek,
Nikesh Koirala,
Sean Oh,
Stefano Lupi
Abstract:
Electrons with a linear energy/momentum dispersion are called massless Dirac electrons and represent the low-energy excitations in exotic materials like Graphene and Topological Insulators (TIs). Dirac electrons are characterized by notable properties like a high mobility, a tunable density and, in TIs, a protection against backscattering through the spin-momentum looking mechanism. All those prop…
▽ More
Electrons with a linear energy/momentum dispersion are called massless Dirac electrons and represent the low-energy excitations in exotic materials like Graphene and Topological Insulators (TIs). Dirac electrons are characterized by notable properties like a high mobility, a tunable density and, in TIs, a protection against backscattering through the spin-momentum looking mechanism. All those properties make Graphene and TIs appealling for plasmonics applications. However, Dirac electrons are expected to present also a strong nonlinear optical behavior. This should mirror in phenomena like electromagnetic induced transparency (EIT) and harmonic generation. Here, we demonstrate that in Bi2Se3 Topological Insulator, an EIT is achieved under the application of a strong terahertz (THz) electric field. This effect, concomitant determined by harmonic generation and charge-mobility reduction, is exclusively related to the presence of Dirac electron at the surface of Bi2Se_3, and opens the road towards tunable THz nonlinear optical devices based on Topological Insulator materials.
△ Less
Submitted 8 May, 2018;
originally announced May 2018.
-
Evolution of the electric fields induced in high intensity laser-matter interactions
Authors:
F. G. Bisesto,
M. P. Anania,
M. Botton,
E. Chiadroni,
A. Cianchi,
A. Curcio,
M. Ferrario,
M. Galletti,
Z. Henis,
R. Pompili,
E. Schleifer,
A. Zigler
Abstract:
Multi MeV protons \cite{snavely2000intense} and heavier ions are emitted by thin foils irradiated by high-intensity lasers, due to the huge accelerating fields, up to several teraelectronvolt per meter, at sub-picosecond timescale \cite{dubois2014target}. The evolution of these huge fields is not well understood till today. Here we report, for the first time, direct and temporally resolved measure…
▽ More
Multi MeV protons \cite{snavely2000intense} and heavier ions are emitted by thin foils irradiated by high-intensity lasers, due to the huge accelerating fields, up to several teraelectronvolt per meter, at sub-picosecond timescale \cite{dubois2014target}. The evolution of these huge fields is not well understood till today. Here we report, for the first time, direct and temporally resolved measurements of the electric fields produced by the interaction of a short-pulse high-intensity laser with solid targets. The results, obtained with a sub-$100$ fs temporal diagnostics, show that such fields build-up in few hundreds of femtoseconds and lasts after several picoseconds.
△ Less
Submitted 12 March, 2018;
originally announced March 2018.
-
Plasma ramps caused by outflow in gas-filled capillaries
Authors:
F. Filippi,
M. P. Anania,
A. Biagioni,
E. Brentegani,
E. Chiadroni,
A. Cianchi,
M. Ferrario,
A. Marocchino,
A. Zigler
Abstract:
Plasma confinement inside capillaries has been developed in the past years for plasma-based acceleration to ensure a stable and repeatable plasma density distribution during the interaction with either particles or laser beams. In particular, gas-filled capillaries allow a stable and almost predictable plasma distribution along the interaction with the particles. However, the plasma ejected throug…
▽ More
Plasma confinement inside capillaries has been developed in the past years for plasma-based acceleration to ensure a stable and repeatable plasma density distribution during the interaction with either particles or laser beams. In particular, gas-filled capillaries allow a stable and almost predictable plasma distribution along the interaction with the particles. However, the plasma ejected through the ends of the capillary interacts with the beam before the inner plasma, affecting the quality of the beam. In this article we report the measurements on the evolution of the plasma flow at the two ends of a 1 cm long, 1 mm diameter capillary filled with hydrogen. In particular, we measured the longitudinal density distribution and the expansion velocity of the plasma outside the capillary. This study will allow a better understanding of the beam-plasma interaction for future plasma-based experiments.
△ Less
Submitted 27 February, 2018;
originally announced February 2018.
-
EuPRAXIA@SPARC_LAB: the high-brightness RF photo-injector layout proposal
Authors:
A. Giribono,
A. Bacci,
E. Chiadroni,
A. Cianchi,
M. Croia,
M. Ferrario,
A. Marocchino,
V. Petrillo,
R. Pompili,
S. Romeo,
M. Rossetti Conti,
A. R. Rossi,
C. Vaccarezza
Abstract:
At EuPRAXIA@SPARC_LAB, the unique combination of an advanced high-brightness RF injector and a plasma-based accelerator will drive a new multi-disciplinary user-facility. The facility, that is currently under study at INFN-LNF Laboratories (Frascati, Italy) in synergy with the EuPRAXIA collaboration, will operate the plasma-based accelerator in the external injection configuration. Since in this c…
▽ More
At EuPRAXIA@SPARC_LAB, the unique combination of an advanced high-brightness RF injector and a plasma-based accelerator will drive a new multi-disciplinary user-facility. The facility, that is currently under study at INFN-LNF Laboratories (Frascati, Italy) in synergy with the EuPRAXIA collaboration, will operate the plasma-based accelerator in the external injection configuration. Since in this configuration the stability and reproducibility of the acceleration process in the plasma stage is strongly influenced by the RF-generated electron beam, the main challenge for the RF injector design is related to generating and handling high quality electron beams. In the last decades of R&D activity, the crucial role of high-brightness RF photo-injectors in the fields of radiation generation and advanced acceleration schemes has been largely established, making them effective candidates to drive plasma-based accelerators as pilots for user facilities. An RF injector consisting in a high-brightness S-band photo-injector followed by an advanced X-band linac has been proposed for the EuPRAXIA@SPARC_LAB project. The electron beam dynamics in the photo-injector has been explored by means of simulations, resulting in high-brightness, ultra-short bunches with up to 3 kA peak current at the entrance of the advanced X-band linac booster. The EuPRAXIA@SPARC_LAB high-brightness photo-injector is described here together with performance optimisation and sensitivity studies aiming to actual check the robustness and reliability of the desired working point.
△ Less
Submitted 25 February, 2018;
originally announced February 2018.
-
Plasma boosted electron beams for driving Free Electron Lasers
Authors:
A. R. Rossi,
V. Petrillo,
A. Bacci,
E. Chiadroni,
A. Cianchi,
M. Ferrario,
A. Giribono,
A. Marocchino,
M. Rossetti Conti,
L. Serafini,
C. Vaccarezza
Abstract:
In this paper, we report results of simulations, in the framework of both EuPRAXIA \cite{Walk2017} and EuPRAXIA@SPARC\_LAB \cite{Ferr2017} projects, aimed at delivering a high brightness electron bunch for driving a Free Electron Laser (FEL) by employing a plasma post acceleration scheme. The boosting plasma wave is driven by a tens of \SI{}{\tera\watt} class laser and doubles the energy of an ext…
▽ More
In this paper, we report results of simulations, in the framework of both EuPRAXIA \cite{Walk2017} and EuPRAXIA@SPARC\_LAB \cite{Ferr2017} projects, aimed at delivering a high brightness electron bunch for driving a Free Electron Laser (FEL) by employing a plasma post acceleration scheme. The boosting plasma wave is driven by a tens of \SI{}{\tera\watt} class laser and doubles the energy of an externally injected beam up to \GeV{1}. The injected bunch is simulated starting from a photoinjector, matched to plasma, boosted and finally matched to an undulator, where its ability to produce FEL radiation is verified to yield $O(\num{e11})$ photons per shot at \nm{2.7}.
△ Less
Submitted 19 February, 2018;
originally announced February 2018.
-
Simulation design for forthcoming high quality plasma wakefield acceleration experiment in linear regime at SPARC_LAB
Authors:
Stefano Romeo,
Enrica Chiadroni,
Michele Croia,
Massimo Ferrario,
Anna Giribono,
Alberto Marocchino,
Francesco Mira,
Riccardo Pompili,
Andrea Renato Rossi,
Cristina Vaccarezza
Abstract:
In the context of plasma wakefield acceleration beam driven, we exploit a high density charge trailing bunch whose self-fields act by mitigating the energy spread increase via beam loading compensation, together with bunch self-contain operated by the self-consistent transverse field. The work, that will be experimentally tested in the SPARC_LAB test facility, consists of a parametric scan that al…
▽ More
In the context of plasma wakefield acceleration beam driven, we exploit a high density charge trailing bunch whose self-fields act by mitigating the energy spread increase via beam loading compensation, together with bunch self-contain operated by the self-consistent transverse field. The work, that will be experimentally tested in the SPARC_LAB test facility, consists of a parametric scan that allows to find optimized parameters in order to preserve the high quality of the trailing bunch over the entire centimeters acceleration length, with a final energy spread increase of 0.1% and an emittance increase of 5 nm. The stability of trailing bunch parameters after acceleration is tested employing a systematic scan of the parameters of the bunches at the injection. The results show that the energy spread increase keeps lower than 1% and the emittance increase is lower than 0.02 mm mrad in all the simulations performed. The energy jitter is of the order of 5%.
△ Less
Submitted 14 February, 2018;
originally announced February 2018.
-
Conceptual design of electron beam diagnostics for high brightness plasma accelerator
Authors:
A. Cianchi,
D. Alesini,
M. P. Anania,
F. Biagioni,
F. Bisesto,
E. Chiadroni,
A. Curcio,
M. Ferrario,
F. Filippi,
A. Ghigo,
A. Giribono,
V. Lollo,
A. Mostacci,
R. Pompili,
L. Sabbatini,
V. Shpakov,
A. Stella,
C. Vaccarezza,
A. Vannozzi,
F. Villa
Abstract:
A design study of the diagnostics of a high brightness linac, based on X-band structures, and a plasma accelerator stage, has been delivered in the framework of the EuPRAXIA@SPARC_LAB project. In this paper, we present a conceptual design of the proposed diagnostics, using state of the art systems and new and under development devices. Single shot measurements are preferable for plasma accelerated…
▽ More
A design study of the diagnostics of a high brightness linac, based on X-band structures, and a plasma accelerator stage, has been delivered in the framework of the EuPRAXIA@SPARC_LAB project. In this paper, we present a conceptual design of the proposed diagnostics, using state of the art systems and new and under development devices. Single shot measurements are preferable for plasma accelerated beams, including emittance, while $μ$m level and fs scale beam size and bunch length respectively are requested. The needed to separate the driver pulse (both laser or beam) from the witness accelerated bunch imposes additional constrains for the diagnostics. We plan to use betatron radiation for the emittance measurement just at the end of the plasma booster, while other single-shot methods must be proven before to be implemented. Longitudinal measurements, being in any case not trivial for the fs level bunch length, seem to have already a wider range of possibilities.
△ Less
Submitted 14 February, 2018;
originally announced February 2018.
-
Design of high brightness Plasma Wakefield Acceleration experiment at SPARC\_LAB test facility with particle-in-cell simulations
Authors:
Alberto Marocchino,
Enrica Chiadroni,
Massimo Ferrario,
Francesco Mira,
Andrea Renato Rossi
Abstract:
The present numerical investigation of a Plasma Wakefield Acceleration scenario in the weakly non linear regime with external injection is motivated by the upcoming campaigns at the SPARC\_LAB test facility where the final goal is to demonstrate modest gradient acceleration ($\sim$1 GV/m) with no quality loss. The accelerated bunch can be envisioned to seed a free electron laser. The numerical stu…
▽ More
The present numerical investigation of a Plasma Wakefield Acceleration scenario in the weakly non linear regime with external injection is motivated by the upcoming campaigns at the SPARC\_LAB test facility where the final goal is to demonstrate modest gradient acceleration ($\sim$1 GV/m) with no quality loss. The accelerated bunch can be envisioned to seed a free electron laser. The numerical study has been conducted with the particle-in-cell code ${\tt ALaDyn}$, an exhaustive description of the plasma-acceleration version is provided. The configuration consider a two bunches setup with parameters in the facility range, the bunches are generated and pre-accelerated up to 100 MeV by a high brightness photo-injector prior plasma injection. To verify the working point robustness we have considered case scenario where the driver bunch reaches the plasma or with a larger dimension or with large emittance. We also present an analytical approach based on the envelope equation that allows to reduce the matching condition in the presence of a ramp. Here, we limit our interest to a simplified theoretical case with a linear plasma ramp. As a final aspect we propose to combine classical integrated bunch diagnostics with the test by Shapiro-Wilk, a mathematical test to diagnose bunch deviation from a Gaussian distribution.
△ Less
Submitted 12 February, 2018;
originally announced February 2018.
-
Energy Measurements by Means of Transition Radiation in novel Linacs
Authors:
M. Marongiu,
M. Castellano,
E. Chiadroni,
A. Cianchi,
G. Franzini,
A. Giribono,
A. Mostacci,
L. Palumbo,
V. Shpakov,
A. Stella,
A. Variola
Abstract:
Advanced linear accelerator design may use Optical Transition Radiation (OTR) screens to measure beam spot size; for instance, such screens are foreseen in plasma based accelerators (EuPRAXIA@SPARC_LAB) or Compton machines (Gamma Beam Source@ELI-NP). Optical Transition Radiation angular distribution strongly depends on beam energy. Since OTR screens are typically placed in several positions along…
▽ More
Advanced linear accelerator design may use Optical Transition Radiation (OTR) screens to measure beam spot size; for instance, such screens are foreseen in plasma based accelerators (EuPRAXIA@SPARC_LAB) or Compton machines (Gamma Beam Source@ELI-NP). Optical Transition Radiation angular distribution strongly depends on beam energy. Since OTR screens are typically placed in several positions along the Linac to monitor the beam envelope, one may perform a distributed energy measurement along the machine. Furthermore, a single shot energy measurement can be useful in plasma accelerators to measure shot to shot energy variations after the plasma interaction. Preliminary measurements of OTR angular distribution of about 100 MeV electrons have been performed at the SPARC_LAB facility. In this paper, we discuss the sensitivity of this measurement to beam divergence and others parameters, as well as the resolution required and the needed upgrades of conventional OTR diagnostics, using as an example the data collected at SPARC_LAB.
△ Less
Submitted 12 February, 2018;
originally announced February 2018.
-
Recent studies on single-shot diagnostics for plasma accelerators at SPARC_LAB
Authors:
F. G. Bisesto,
M. P. Anania,
M. Botton,
M. Castellano,
E. Chiadroni,
A. Cianchi,
A. Curcio,
M. Ferrario,
M. Galletti,
Z. Henis,
R. Pompili,
E. Schleifer,
V. Shpakov,
A. Zigler
Abstract:
Plasma wakefield acceleration is the most promising acceleration technique for compact and cheap accelerators, thanks to the high accelerating gradients achievable. Nevertheless, this approach still suffers of shot-to-shot instabilities, mostly related to experimental parameters fluctuations. Therefore, the use of single shot diagnostics is needed to properly understand the acceleration mechanism.…
▽ More
Plasma wakefield acceleration is the most promising acceleration technique for compact and cheap accelerators, thanks to the high accelerating gradients achievable. Nevertheless, this approach still suffers of shot-to-shot instabilities, mostly related to experimental parameters fluctuations. Therefore, the use of single shot diagnostics is needed to properly understand the acceleration mechanism. In this work, we present two diagnostics to probe electron beams from laser-plasma interactions, one relying on Electro Optical Sampling (EOS) for laser-solid matter interactions, the other one based on Optical Transition Radiation (OTR) for single shot measurements of the transverse emittance of plasma accelerated electron beams, both developed at the SPARC_LAB Test Facility.
△ Less
Submitted 9 February, 2018;
originally announced February 2018.
-
Plasma acceleration limitations due to betatron radiation
Authors:
V. Shpakov,
E. Chiadroni,
A. Curcio,
H. Fares,
M. Ferrario,
A. Marocchino,
F. Mira,
V. Petrillo,
A. R. Rossi,
S. Romeo
Abstract:
High energy spread caused by the longitudinal size of the beam is well known in wake-field acceleration. Usually this issue can be solved with beam loading effect that allows to keep accelerating field nearly constant, along the whole duration of the beam. In this work, however, we would like to address another source of energy spread that arises at high energy, due to betatron radiation.
High energy spread caused by the longitudinal size of the beam is well known in wake-field acceleration. Usually this issue can be solved with beam loading effect that allows to keep accelerating field nearly constant, along the whole duration of the beam. In this work, however, we would like to address another source of energy spread that arises at high energy, due to betatron radiation.
△ Less
Submitted 9 February, 2018;
originally announced February 2018.
-
Characterization of self-injected electron beams from LWFA experiments at SPARC_LAB
Authors:
G. Costa,
M. P. Anania,
F. Bisesto,
E. Chiadroni,
A. Cianchi,
A. Curcio,
M. Ferrario,
F. Filippi,
A. Marocchino,
F. Mira,
R. Pompili,
A. Zigler
Abstract:
The plasma-based acceleration is an encouraging technique to overcome the limits of the accelerating gradient in the conventional RF acceleration. A plasma accelerator is able to provide accelerating fields up to hundreds of $GeV/m$, paving the way to accelerate particles to several MeV over a short distance (below the millimetre range). Here the characteristics of preliminary electron beams obtai…
▽ More
The plasma-based acceleration is an encouraging technique to overcome the limits of the accelerating gradient in the conventional RF acceleration. A plasma accelerator is able to provide accelerating fields up to hundreds of $GeV/m$, paving the way to accelerate particles to several MeV over a short distance (below the millimetre range). Here the characteristics of preliminary electron beams obtained with the self-injection mechanism produced with the FLAME high-power laser at the SPARC_LAB test facility are shown. In detail, with an energy laser on focus of $1.5\ J$ and a pulse temporal length (FWHM) of $40\ fs$, we obtained an electron plasma density due to laser ionization of about $6 \times 10^{18}\ cm^{-3}$, electron energy up to $350\ MeV$ and beam charge in the range $(50 - 100)\ pC$.
△ Less
Submitted 3 February, 2018;
originally announced February 2018.
-
The FLAME laser at SPARC_LAB
Authors:
F. G. Bisesto,
M. P. Anania,
M. Bellaveglia,
E. Chiadroni,
A. Cianchi,
G. Costa,
A. Curcio,
D. Di Giovenale,
G. Di Pirro,
M. Ferrario,
F. Filippi,
A. Gallo,
A. Marocchino,
R. Pompili,
A. Zigler,
C. Vaccarezza
Abstract:
FLAME is a high power laser system installed at the SPARC_LAB Test Facility in Frascati (Italy). The ultra-intense laser pulses are employed to study the interaction with matter for many purposes: electron acceleration through LWFA, ion and proton generation exploiting the TNSA mechanism, study of new radiation sources and development of new electron diagnostics. In this work, an overview of the F…
▽ More
FLAME is a high power laser system installed at the SPARC_LAB Test Facility in Frascati (Italy). The ultra-intense laser pulses are employed to study the interaction with matter for many purposes: electron acceleration through LWFA, ion and proton generation exploiting the TNSA mechanism, study of new radiation sources and development of new electron diagnostics. In this work, an overview of the FLAME laser system will be given, together with recent experimental results
△ Less
Submitted 1 February, 2018;
originally announced February 2018.
-
Layout considerations for a future electron plasma research accelerator facility EuPRAXIA
Authors:
Paul Andreas Walker,
Ralph Wolfgang Assmann,
Reinhard Brinkmann,
Enrica Chiadroni,
Ulrich Dorda,
Massimo Ferrario,
Dariusz Kocon,
Barbara Marchetti,
Lukas Pribyl,
Arnd Specka,
Roman Walczak
Abstract:
The Horizon 2020 Project EuPRAXIA (European Plasma Research Accelerator with eXcellence In Applications) is preparing a conceptual design for a highly compact and cost-effective European facility with multi-GeV electron beams using plasma as the acceleration medium. The design includes two user areas: one for FEL science and one for High Energy Physics (HEP) detector development and other pilot ap…
▽ More
The Horizon 2020 Project EuPRAXIA (European Plasma Research Accelerator with eXcellence In Applications) is preparing a conceptual design for a highly compact and cost-effective European facility with multi-GeV electron beams using plasma as the acceleration medium. The design includes two user areas: one for FEL science and one for High Energy Physics (HEP) detector development and other pilot applications. The accelerator facility will be based on a laser and/or a beam driven plasma acceleration approach. This contribution introduces layout considerations of the future plasma accelerator facilities in the context of EuPRAXIA. It compares conventional and novel plasma accelerator facility requirements and presents potential layouts for the future site. Together with performance analysis, cost effectiveness, and targeted user cases of the individual configurations, such layout studies will later enable a ranking of potential configurations. Based on this information the optimal combination of technologies will be defined for the 2019 conceptual design report of the EuPRAXIA facility.
△ Less
Submitted 1 February, 2018;
originally announced February 2018.
-
Overview of Plasma Lens Experiments and Recent Results at SPARC_LAB
Authors:
E. Chiadroni,
M. P. Anania,
M. Bellaveglia,
A. Biagioni,
F. Bisesto,
E. Brentegani,
F. Cardelli,
A. Cianchi,
G. Costa,
D. Di Giovenale,
G. Di Pirro,
M. Ferrario,
F. Filippi,
A. Gallo,
A. Giribono,
A. Marocchino,
A. Mostacci,
L. Piersanti,
R. Pompili,
J. B. Rosenzweig,
A. R. Rossi,
J. Scifo,
V. Shpakov,
C. Vaccarezza,
F. Villa
, et al. (1 additional authors not shown)
Abstract:
Beam injection and extraction from a plasma module is still one of the crucial aspects to solve in order to produce high quality electron beams with a plasma accelerator. Proper matching conditions require to focus the incoming high brightness beam down to few microns size and to capture a high divergent beam at the exit without loss of beam quality. Plasma-based lenses have proven to provide focu…
▽ More
Beam injection and extraction from a plasma module is still one of the crucial aspects to solve in order to produce high quality electron beams with a plasma accelerator. Proper matching conditions require to focus the incoming high brightness beam down to few microns size and to capture a high divergent beam at the exit without loss of beam quality. Plasma-based lenses have proven to provide focusing gradients of the order of kT/m with radially symmetric focusing thus promising compact and affordable alternative to permanent magnets in the design of transport lines. In this paper an overview of recent experiments and future perspectives of plasma lenses is reported.
△ Less
Submitted 1 February, 2018;
originally announced February 2018.
-
EUPRAXIA@SPARC_LAB: Beam Dynamics studies for the X-band Linac
Authors:
C. Vaccarezza,
D. Alesini,
A. Bacci,
A. Cianchi,
E. Chiadroni,
M. Croia,
M. Diomede,
M. Ferrario,
A. Gallo,
A. Giribono,
A. Latina,
A. Marocchino,
V. Petrillo,
R. Pompili,
S. Romeo,
M. Rossetti Conti,
A. R. Rossi,
L. Serafini,
B. Spataro
Abstract:
In the framework of the Eupraxia Design Study an advanced accelerator facility EUPRAXIA@SPARC_LAB has been proposed to be realized at Frascati (Italy) Laboratories of INFN. Two advanced acceleration schemes will be applied, namely an ultimate high gradient 1 GeV X-band linac together with a plasma acceleration stage to provide accelerating gradients of the GeV/m order. A FEL scheme is foreseen to…
▽ More
In the framework of the Eupraxia Design Study an advanced accelerator facility EUPRAXIA@SPARC_LAB has been proposed to be realized at Frascati (Italy) Laboratories of INFN. Two advanced acceleration schemes will be applied, namely an ultimate high gradient 1 GeV X-band linac together with a plasma acceleration stage to provide accelerating gradients of the GeV/m order. A FEL scheme is foreseen to produce X-ray beams within 3-10 nm range. A 500-TW Laser system is also foreseen for electron and ion production experiments and a Compton backscattering Interaction is planned together with extraction beamlines at intermediate electron beam energy for neutron beams and THz radiation production. The electron beam dynamics studies in the linac are here presented together with the preliminary machine layout.
△ Less
Submitted 30 January, 2018;
originally announced January 2018.
-
EuPRAXIA@SPARC_LAB Design study towards a compact FEL facility at LNF
Authors:
M. Ferrario,
D. Alesini,
M. P. Anania,
M. Artioli,
A. Bacci,
S. Bartocci,
R. Bedogni,
M. Bellaveglia,
A. Biagioni,
F. Bisesto,
F. Brandi,
E. Brentegani,
F. Broggi,
B. Buonomo,
P. L. Campana,
G. Campogiani,
C. Cannaos,
S. Cantarella,
F. Cardelli,
M. Carpanese,
M. Castellano,
G. Castorina,
N. Catalan Lasheras,
E. Chiadroni,
A. Cianchi
, et al. (95 additional authors not shown)
Abstract:
On the wake of the results obtained so far at the SPARC\_LAB test-facility at the Laboratori Nazionali di Frascati (Italy), we are currently investigating the possibility to design and build a new multi-disciplinary user-facility, equipped with a soft X-ray Free Electron Laser (FEL) driven by a $\sim$1 GeV high brightness linac based on plasma accelerator modules. This design study is performed in…
▽ More
On the wake of the results obtained so far at the SPARC\_LAB test-facility at the Laboratori Nazionali di Frascati (Italy), we are currently investigating the possibility to design and build a new multi-disciplinary user-facility, equipped with a soft X-ray Free Electron Laser (FEL) driven by a $\sim$1 GeV high brightness linac based on plasma accelerator modules. This design study is performed in synergy with the EuPRAXIA design study. In this paper we report about the recent progresses in the on going design study of the new facility.
△ Less
Submitted 26 January, 2018;
originally announced January 2018.
-
Recent results at SPARC_LAB
Authors:
R. Pompili,
M. P. Anania,
M. Bellaveglia,
A. Biagioni,
S. Bini,
F. Bisesto,
E. Chiadroni,
A. Cianchi,
G. Costa,
D. Di Giovenale,
M. Ferrario,
F. Filippi,
A. Gallo,
A. Giribono,
V. Lollo,
A. Marocchino,
V. Martinelli,
A. Mostacci,
G. Di Pirro,
S. Romeo,
J. Scifo,
V. Shpakov,
C. Vaccarezza,
F. Villa,
A. Zigler
Abstract:
The current activity of the SPARC_LAB test-facility is focused on the realization of plasma-based acceleration experiments with the aim to provide accelerating field of the order of several GV/m while maintaining the overall quality (in terms of energy spread and emittance) of the accelerated electron bunch. In the following, the current status of such an activity is presented. We also show result…
▽ More
The current activity of the SPARC_LAB test-facility is focused on the realization of plasma-based acceleration experiments with the aim to provide accelerating field of the order of several GV/m while maintaining the overall quality (in terms of energy spread and emittance) of the accelerated electron bunch. In the following, the current status of such an activity is presented. We also show results related to the usability of plasmas as focusing lenses in view of a complete plasma-based focusing and accelerating system.
△ Less
Submitted 18 January, 2018;
originally announced January 2018.
-
Wake fields effects in dielectric capillary
Authors:
A. Biagioni,
M. P. Anania,
M. Bellaveglia,
E. Brentegani,
G. Castorina,
E. Chiadroni,
A. Cianchi,
D. Di Giovenale,
G. Di Pirro,
H. Fares,
L. Ficcadenti,
F. Filippi,
M. Ferrario,
A. Mostacci,
R. Pompili,
J. Scifo,
B. Spataro,
C. Vaccarezza,
F. Villa,
A. Zigler
Abstract:
Plasma wake-field acceleration experiments are performed at the SPARC LAB test facility by using a gas-filled capillary plasma source composed of a dielectric capillary. The electron can reach GeV energy in a few centimeters, with an accelerating gradient orders of magnitude larger than provided by conventional techniques. In this acceleration scheme, wake fields produced by passing electron beams…
▽ More
Plasma wake-field acceleration experiments are performed at the SPARC LAB test facility by using a gas-filled capillary plasma source composed of a dielectric capillary. The electron can reach GeV energy in a few centimeters, with an accelerating gradient orders of magnitude larger than provided by conventional techniques. In this acceleration scheme, wake fields produced by passing electron beams through dielectric structures can determine a strong beam instability that represents an important hurdle towards the capability to focus high-current electron beams in the transverse plane. For these reasons, the estimation of the transverse wakefield amplitudes assumes a fundamental role in the implementation of the plasma wake-field acceleration. In this work, it presented a study to investigate which parameters affect the wake-field formation inside a cylindrical dielectric structure, both the capillary dimensions and the beam parameters, and it is introduced a quantitative evaluation of the longitudinal and transverse electric fields.
△ Less
Submitted 12 January, 2018;
originally announced January 2018.
-
Nano-machining, surface analysis and emittance measurements of a copper photocathode at SPARC_LAB
Authors:
J. Scifo,
D. Alesini,
M. P. Anania,
M. Bellaveglia,
S. Bellucci,
A. Biagioni,
F. Bisesto,
F. Cardelli,
E. Chiadroni,
A. Cianchi,
G. Costa,
D. Di Giovenale,
G. Di Pirro,
R. Di Raddo,
D. H. Dowell,
M. Ferrario,
A. Giribono,
A. Lorusso,
F. Micciulla,
A. Mostacci,
D. Passeri,
A. Perrone,
L. Piersanti,
R. Pompili,
V. Shpakov
, et al. (3 additional authors not shown)
Abstract:
R\&D activity on Cu photocathodes is under development at the SPARC\_LAB test facility to fully characterize each stage of the photocathode "life" and to have a complete overview of the photoemission properties in high brightness photo-injectors. The nano(n)-machining process presented here consists in diamond milling, and blowing with dry nitrogen. This procedure reduces the roughness of the cath…
▽ More
R\&D activity on Cu photocathodes is under development at the SPARC\_LAB test facility to fully characterize each stage of the photocathode "life" and to have a complete overview of the photoemission properties in high brightness photo-injectors. The nano(n)-machining process presented here consists in diamond milling, and blowing with dry nitrogen. This procedure reduces the roughness of the cathode surface and prevents surface contamination introduced by other techniques, such as polishing with diamond paste or the machining with oil. Both high roughness and surface contamination cause an increase of intrinsic emittance and consequently a reduction of the overall electron beam brightness. To quantify these effects, we have characterized the photocathode surface in terms of roughness measurement, and morphology and chemical composition analysis by means of Scanning Electron Microscopy (SEM), Energy Dispersive Spectroscopy (EDS), and Atomic Force Microscopy (AFM) techniques. The effects of n-machining on the electron beam quality have been also investigated through emittance measurements before and after the surface processing technique. Finally, we present preliminary emittance studies of yttrium thin film on Cu photocathodes.
△ Less
Submitted 11 January, 2018;
originally announced January 2018.
-
RF injector design studies for the trailing witness bunch for a plasma-based user facility
Authors:
A. Giribono,
A. Bacci,
E. Chiadroni,
A. Cianchi,
M. Croia,
M. Ferrario,
A. Marocchino,
V. Petrillo,
R. Pompili,
S. Romeo,
M. Rossetti Conti,
A. R. Rossi,
C. Vaccarezza
Abstract:
The interest in plasma-based accelerators as drivers of user facilities is growing worldwide thanks to its compactness and reduced costs. In this context the EuPRAXIA collaboration is preparing a conceptual design report for a multi-GeV plasma-based accelerator with outstanding electron beam quality to pilot, among several applications, the operation of an X-ray FEL, the most demanding in terms of…
▽ More
The interest in plasma-based accelerators as drivers of user facilities is growing worldwide thanks to its compactness and reduced costs. In this context the EuPRAXIA collaboration is preparing a conceptual design report for a multi-GeV plasma-based accelerator with outstanding electron beam quality to pilot, among several applications, the operation of an X-ray FEL, the most demanding in terms of beam brightness. Intense beam dynamics studies have been performed to provide a reliable working point for the RF injector to generate a high-brightness trailing witness bunch suitable in external injection schemes, both in particle beam and laser driven plasma wakefield acceleration. A case of interest is the generation of a witness beam with 1 GeV energy, less than 1 mm-mrad slice emittance and 30 pC in 10 fs FWHM bunch length, which turns into 3 kA peak current at the undulator entrance. The witness beam has been successfully compressed down to 10 fs in a conventional SPARC-like photo-injector and boosted up to 500 MeV in an advanced high-gradient X-band linac reaching the plasma entrance with 3 kA peak current and the following RMS values: 0.06% energy spread, 0.5 mm-mrad transverse normalised emittance and a focal spot down to 1 $μm$. RF injector studies are here presented with the aim to satisfy the EuPRAXIA requests for the Design Study of a plasma-based user facility.
△ Less
Submitted 16 January, 2018; v1 submitted 9 January, 2018;
originally announced January 2018.
-
Preliminary RF design of an X-band linac for the EuPRAXIA@SPARC_LAB project
Authors:
M. Diomede,
D. Alesini,
M. Bellaveglia,
B. Buonomo,
F. Cardelli,
N. Catalan Lasheras,
E. Chiadroni,
G. Di Pirro,
M. Ferrario,
A. Gallo,
A. Ghigo,
A. Giribono,
A. Grudiev,
L. Piersanti,
B. Spataro,
C. Vaccarezza,
W. Wuensch
Abstract:
In the framework of the upgrade of the SPARC_LAB facility at INFN-LNF, named EuPRAXIA@SPARC_LAB, a high gradient linac is foreseen. One of the most suitable options is to realize it in X-band. A preliminary design study of both accelerating structures and power distribution system has been performed. It is based on 0.5 m long travelling wave (TW) accelerating structures operating in the 2π/3 mode…
▽ More
In the framework of the upgrade of the SPARC_LAB facility at INFN-LNF, named EuPRAXIA@SPARC_LAB, a high gradient linac is foreseen. One of the most suitable options is to realize it in X-band. A preliminary design study of both accelerating structures and power distribution system has been performed. It is based on 0.5 m long travelling wave (TW) accelerating structures operating in the 2π/3 mode and fed by klystrons and pulse compressor systems. The main parameters of the structures and linac are presented with the basic RF linac layout.
△ Less
Submitted 2 January, 2018;
originally announced January 2018.
-
Technical Design Report EuroGammaS proposal for the ELI-NP Gamma beam System
Authors:
O. Adriani,
S. Albergo,
D. Alesini,
M. Anania,
D. Angal-Kalinin,
P. Antici,
A. Bacci,
R. Bedogni,
M. Bellaveglia,
C. Biscari,
N. Bliss,
R. Boni,
M. Boscolo,
F. Broggi,
P. Cardarelli,
K. Cassou,
M. Castellano,
L. Catani,
I. Chaikovska,
E. Chiadroni,
R. Chiche,
A. Cianchi,
J. Clarke,
A. Clozza,
M. Coppola
, et al. (84 additional authors not shown)
Abstract:
The machine described in this document is an advanced Source of up to 20 MeV Gamma Rays based on Compton back-scattering, i.e. collision of an intense high power laser beam and a high brightness electron beam with maximum kinetic energy of about 720 MeV. Fully equipped with collimation and characterization systems, in order to generate, form and fully measure the physical characteristics of the pr…
▽ More
The machine described in this document is an advanced Source of up to 20 MeV Gamma Rays based on Compton back-scattering, i.e. collision of an intense high power laser beam and a high brightness electron beam with maximum kinetic energy of about 720 MeV. Fully equipped with collimation and characterization systems, in order to generate, form and fully measure the physical characteristics of the produced Gamma Ray beam. The quality, i.e. phase space density, of the two colliding beams will be such that the emitted Gamma ray beam is characterized by energy tunability, spectral density, bandwidth, polarization, divergence and brilliance compatible with the requested performances of the ELI-NP user facility, to be built in Romania as the Nuclear Physics oriented Pillar of the European Extreme Light Infrastructure. This document illustrates the Technical Design finally produced by the EuroGammaS Collaboration, after a thorough investigation of the machine expected performances within the constraints imposed by the ELI-NP tender for the Gamma Beam System (ELI-NP-GBS), in terms of available budget, deadlines for machine completion and performance achievement, compatibility with lay-out and characteristics of the planned civil engineering.
△ Less
Submitted 14 July, 2014;
originally announced July 2014.
-
IRIDE White Book, An Interdisciplinary Research Infrastructure based on Dual Electron linacs&lasers
Authors:
D. Alesini,
M. Alessandroni,
M. P. Anania,
S. Andreas,
M. Angelone,
A. Arcovito,
F. Arnesano,
M. Artioli,
L. Avaldi,
D. Babusci,
A. Bacci,
A. Balerna,
S. Bartalucci,
R. Bedogni,
M. Bellaveglia,
F. Bencivenga,
M. Benfatto,
S. Biedron,
V. Bocci,
M. Bolognesi,
P. Bolognesi,
R. Boni,
R. Bonifacio,
M. Boscolo,
F. Boscherini
, et al. (189 additional authors not shown)
Abstract:
This report describes the scientific aims and potentials as well as the preliminary technical design of IRIDE, an innovative tool for multi-disciplinary investigations in a wide field of scientific, technological and industrial applications. IRIDE will be a high intensity 'particle factory', based on a combination of a high duty cycle radio-frequency superconducting electron linac and of high ener…
▽ More
This report describes the scientific aims and potentials as well as the preliminary technical design of IRIDE, an innovative tool for multi-disciplinary investigations in a wide field of scientific, technological and industrial applications. IRIDE will be a high intensity 'particle factory', based on a combination of a high duty cycle radio-frequency superconducting electron linac and of high energy lasers. Conceived to provide unique research possibilities for particle physics, for condensed matter physics, chemistry and material science, for structural biology and industrial applications, IRIDE will open completely new research possibilities and advance our knowledge in many branches of science and technology. IRIDE will contribute to open new avenues of discoveries and to address most important riddles: What does matter consist of? What is the structure of proteins that have a fundamental role in life processes? What can we learn from protein structure to improve the treatment of diseases and to design more efficient drugs? But also how does an electronic chip behave under the effect of radiations? How can the heat flow in a large heat exchanger be optimized? The scientific potential of IRIDE is far reaching and justifies the construction of such a large facility in Italy in synergy with the national research institutes and companies and in the framework of the European and international research. It will impact also on R&D work for ILC, FEL, and will be complementarity to other large scale accelerator projects. IRIDE is also intended to be realized in subsequent stages of development depending on the assigned priorities.
△ Less
Submitted 30 July, 2013;
originally announced July 2013.
-
Coupling of Laser-Generated Electrons with Conventional Accelerator Devices
Authors:
P. Antici,
A. Bacci,
C. Benedetti,
E. Chiadroni,
M. Ferrario,
L. Lancia,
M. Migliorati,
A. Mostacci,
L. Palumbo,
A. R. Rossi,
L. Serafini
Abstract:
Laser-based electron acceleration is attracting strong interest from the conventional accelerator community due to its outstanding characteristics in terms of high initial energy, low emittance and high beam current. Unfortunately, such beams are currently not comparable to those of conventional accelerators, limiting their use for the manifold applications that a traditional accelerator can have.…
▽ More
Laser-based electron acceleration is attracting strong interest from the conventional accelerator community due to its outstanding characteristics in terms of high initial energy, low emittance and high beam current. Unfortunately, such beams are currently not comparable to those of conventional accelerators, limiting their use for the manifold applications that a traditional accelerator can have. Besides working on the plasma source itself, a promising approach to shape the laser-generated beams is coupling them with conventional accelerator elements in order to benefit from both, a versatile electron source and a controllable beam.
In this paper we show that some parameters commonly used by the particle accelerator community must be reconsidered when dealing with laser-plasma beams. Starting from the parameters of laser-generated electrons which can be obtained nowadays by conventional multi hundred TW laser systems, we compare different conventional magnetic lattices able to capture and transport those GeV electrons. From this comparison we highlight some important limit of the state-of-the-art plasma generated electrons with respect to conventional accelerator ones. Eventually we discuss an application of such beams in undulators for Free Electron Lasers (FELs), which is one of the most demanding applications in terms of beam quality.
△ Less
Submitted 15 December, 2011;
originally announced December 2011.
-
Proposal for taking data with the KLOE-2 detector at the DA$Φ$NE collider upgraded in energy
Authors:
D. Babusci,
C. Bini,
F. Bossi,
G. Isidori,
D. Moricciani,
F. Nguyen,
P. Raimondi,
G. Venanzoni,
D. Alesini,
F. Archilli,
D. Badoni,
R. Baldini-Ferroli,
M. Bellaveglia,
G. Bencivenni,
M. Bertani,
M. Biagini,
C. Biscari,
C. Bloise,
V. Bocci,
R. Boni,
M. Boscolo,
P. Branchini,
A. Budano,
S. A. Bulychjev,
B. Buonomo
, et al. (97 additional authors not shown)
Abstract:
This document reviews the physics program of the KLOE-2 detector at DA$Φ$NE upgraded in energy and provides a simple solution to run the collider above the $φ$-peak (up to 2, possibly 2.5 GeV). It is shown how a precise measurement of the multihadronic cross section in the energy region up to 2 (possibly 2.5) GeV would have a major impact on the tests of the Standard Model through a precise determ…
▽ More
This document reviews the physics program of the KLOE-2 detector at DA$Φ$NE upgraded in energy and provides a simple solution to run the collider above the $φ$-peak (up to 2, possibly 2.5 GeV). It is shown how a precise measurement of the multihadronic cross section in the energy region up to 2 (possibly 2.5) GeV would have a major impact on the tests of the Standard Model through a precise determination of the anomalous magnetic moment of the muon and the effective fine-structure constant at the $M_Z$ scale. With a luminosity of about $10^{32}$cm$^{-2}$s$^{-1}$, DA$Φ$NE upgraded in energy can perform a scan in the region from 1 to 2.5 GeV in one year by collecting an integrated luminosity of 20 pb$^{-1}$ (corresponding to a few days of data taking) for single point, assuming an energy step of 25 MeV. A few years of data taking in this region would provide important tests of QCD and effective theories by $γγ$ physics with open thresholds for pseudo-scalar (like the $η'$), scalar ($f_0,f'_0$, etc...) and axial-vector ($a_1$, etc...) mesons; vector-mesons spectroscopy and baryon form factors; tests of CVC and searches for exotics. In the final part of the document a technical solution for the energy upgrade of DA$Φ$NE is proposed.
△ Less
Submitted 29 July, 2010;
originally announced July 2010.