Experimental results from the ST7 mission on LISA Pathfinder
Authors:
G Anderson,
J Anderson,
M Anderson,
G Aveni,
D Bame,
P Barela,
K Blackman,
A Carmain,
L Chen,
M Cherng,
S Clark,
M Connally,
W Connolly,
D Conroy,
M Cooper,
C Cutler,
J D'Agostino,
N Demmons,
E Dorantes,
C Dunn,
M Duran,
E Ehrbar,
J Evans,
J Fernandez,
G Franklin
, et al. (123 additional authors not shown)
Abstract:
The Space Technology 7 Disturbance Reduction System (ST7-DRS) is a NASA technology demonstration payload that operated from January 2016 through July of 2017 on the European Space Agency's LISA Pathfinder spacecraft. The joint goal of the NASA and ESA missions was to validate key technologies for a future space-based gravitational wave observatory targeting the source-rich milliHertz band. The two…
▽ More
The Space Technology 7 Disturbance Reduction System (ST7-DRS) is a NASA technology demonstration payload that operated from January 2016 through July of 2017 on the European Space Agency's LISA Pathfinder spacecraft. The joint goal of the NASA and ESA missions was to validate key technologies for a future space-based gravitational wave observatory targeting the source-rich milliHertz band. The two primary components of ST7-DRS are a micropropulsion system based on colloidal micro-Newton thrusters (CMNTs) and a control system that simultaneously controls the attitude and position of the spacecraft and the two free-flying test masses (TMs). This paper presents our main experimental results and summarizes the overall the performance of the CMNTs and control laws. We find that the CMNT performance to be consistent with pre-flight predictions, with a measured system thrust noise on the order of $100\,\textrm{nN}/\sqrt{\textrm{Hz}}$ in the $1\,\textrm{mHz}\leq f \leq 30\,\textrm{mHz}$ band. The control system maintained the TM-spacecraft separation with an RMS error of less than 2$\,$nm and a noise spectral density of less than $3\,\textrm{nm}/\sqrt{\textrm{Hz}}$ in the same band. Thruster calibration measurements yield thrust values consistent with the performance model and ground-based thrust-stand measurements, to within a few percent. We also report a differential acceleration noise between the two test masses with a spectral density of roughly $3\,\textrm{fm}/\textrm{s}^2/\sqrt{\textrm{Hz}}$ in the $1\,\textrm{mHz}\leq f \leq 30\,\textrm{mHz}$ band, slightly less than twice as large as the best performance reported with the baseline LISA Pathfinder configuration and below the current requirements for the Laser Interferometer Space Antenna (LISA) mission.
△ Less
Submitted 16 October, 2018; v1 submitted 24 September, 2018;
originally announced September 2018.
Technology advancement of the CCD201-20 EMCCD for the WFIRST coronagraph instrument: sensor characterization and radiation damage
Authors:
Leon K. Harding,
Richard T. Demers,
Michael Hoenk,
Pavani Peddada,
Bijan Nemati,
Michael Cherng,
Darren Michaels,
Leo S. Neat,
Anthony Loc,
Nathan Bush,
David Hall,
Neil Murray,
Jason Gow,
Ross Burgon,
Andrew Holland,
Alice Reinheimer,
Paul R. Jorden,
Douglas Jordand
Abstract:
The Wide Field InfraRed Survey Telescope-Astrophysics Focused Telescope Asset (WFIRST-AFTA) mission is a 2.4-m class space telescope that will be used across a swath of astrophysical research domains. JPL will provide a high-contrast imaging coronagraph instrument - one of two major astronomical instruments. In order to achieve the low noise performance required to detect planets under extremely l…
▽ More
The Wide Field InfraRed Survey Telescope-Astrophysics Focused Telescope Asset (WFIRST-AFTA) mission is a 2.4-m class space telescope that will be used across a swath of astrophysical research domains. JPL will provide a high-contrast imaging coronagraph instrument - one of two major astronomical instruments. In order to achieve the low noise performance required to detect planets under extremely low flux conditions, the electron multiplying charge-coupled device (EMCCD) has been baselined for both of the coronagraph's sensors - the imaging camera and integral field spectrograph. JPL has established an EMCCD test laboratory in order to advance EMCCD maturity to technology readiness level-6. This plan incorporates full sensor characterization, including read noise, dark current, and clock-induced charge. In addition, by considering the unique challenges of the WFIRST space environment, degradation to the sensor's charge transfer efficiency will be assessed, as a result of damage from high-energy particles such as protons, electrons, and cosmic rays. Science-grade CCD201-20 EMCCDs have been irradiated to a proton fluence that reflects the projected WFIRST orbit. Performance degradation due to radiation displacement damage is reported, which is the first such study for a CCD201-20 that replicates the WFIRST conditions. In addition, techniques intended to identify and mitigate radiation-induced electron trap**, such as trap pum**, custom clocking, and thermal cycling, are discussed.
△ Less
Submitted 7 January, 2016;
originally announced January 2016.