-
THGEM-based detectors for sampling elements in DHCAL: laboratory and beam evaluation
Authors:
L. Arazi,
A. Breskin,
R. Chechik,
M. Cortesi,
M. Pitt,
A. Rubin,
H. Natal da Luz,
J. M. F. dos Santos,
C. D. R. Azevedo,
D. S. Covita,
C. A. B. Oliveira,
J. F. C. A. Veloso,
M. Breidenbach,
D. Freytag,
G. Haller,
R. Herbst,
S. Park,
A. White,
J. Yu,
E. Oliveri
Abstract:
We report on the results of an extensive R&D program aimed at the evaluation of Thick-Gas Electron Multipliers (THGEM) as potential active elements for Digital Hadron Calorimetry (DHCAL). Results are presented on efficiency, pad multiplicity and discharge probability of a 10x10 cm2 prototype detector with 1 cm2 readout pads. The detector is comprised of single- or double-THGEM multipliers coupled…
▽ More
We report on the results of an extensive R&D program aimed at the evaluation of Thick-Gas Electron Multipliers (THGEM) as potential active elements for Digital Hadron Calorimetry (DHCAL). Results are presented on efficiency, pad multiplicity and discharge probability of a 10x10 cm2 prototype detector with 1 cm2 readout pads. The detector is comprised of single- or double-THGEM multipliers coupled to the pad electrode either directly or via a resistive anode. Investigations employing standard discrete electronics and the KPiX readout system have been carried out both under laboratory conditions and with muons and pions at the CERN RD51 test beam. For detectors having a charge-induction gap, it has been shown that even a ~6 mm thick single-THGEM detector reached detection efficiencies above 95%, with pad-hit multiplicity of 1.1-1.2 per event; discharge probabilities were of the order of 1e-6 - 1e-5 sparks/trigger, depending on the detector structure and gain. Preliminary beam tests with a WELL hole-structure, closed by a resistive anode, yielded discharge probabilities of <2e-6 for an efficiency of ~95%. Methods are presented to reduce charge-spread and pad multiplicity with resistive anodes. The new method showed good prospects for further evaluation of very thin THGEM-based detectors as potential active elements for DHCAL, with competitive performances, simplicity and robustness. Further developments are in course.
△ Less
Submitted 8 December, 2011;
originally announced December 2011.
-
An Optical Readout TPC (O-TPC) for Studies in Nuclear Astrophysics With Gamma-Ray Beams at HIgS
Authors:
M. Gai,
M. W. Ahmed,
S. C. Stave,
W. R. Zimmerman,
A. Breskin,
B. Bromberger,
R. Chechik,
V. Dangendorf,
Th. Delbar,
R. H. France III,
S. S. Henshaw,
T. J. Kading,
P. P. Martel,
J. E. R. McDonald,
P. -N. Seo,
K. Tittelmeier,
H. R. Weller,
A. H. Young
Abstract:
We report on the construction, tests, calibrations and commissioning of an Optical Readout Time Projection Chamber (O-TPC) detector operating with a CO2(80%) + N2(20%) gas mixture at 100 and 150 Torr. It was designed to measure the cross sections of several key nuclear reactions involved in stellar evolution. In particular, a study of the rate of formation of oxygen and carbon during the process o…
▽ More
We report on the construction, tests, calibrations and commissioning of an Optical Readout Time Projection Chamber (O-TPC) detector operating with a CO2(80%) + N2(20%) gas mixture at 100 and 150 Torr. It was designed to measure the cross sections of several key nuclear reactions involved in stellar evolution. In particular, a study of the rate of formation of oxygen and carbon during the process of helium burning will be performed by exposing the chamber gas to intense nearly mono-energetic gamma-ray beams at the High Intensity Gamma Source (HIgS) facility. The O-TPC has a sensitive target-drift volume of 30x30x21 cm^3. Ionization electrons drift towards a double parallel grid avalanche multiplier, yielding charge multiplication and light emission. Avalanche induced photons from N2 emission are collected, intensified and recorded with a Charge Coupled Device (CCD) camera, providing two-dimensional track images. The event's time projection (third coordinate) and the deposited energy are recorded by photomultipliers and by the TPC charge-signal, respectively. A dedicated VME-based data acquisition system and associated data analysis tools were developed to record and analyze these data. The O-TPC has been tested and calibrated with 3.183 MeV alpha-particles emitted by a 148Gd source placed within its volume with a measured energy resolution of 3.0%. Tracks of alpha and 12C particles from the dissociation of 16O and of three alpha-particles from the dissociation of 12C have been measured during initial in-beam test experiments performed at the HIgS facility at Duke University. The full detection system and its performance are described and the results of the preliminary in-beam test experiments are reported.
△ Less
Submitted 10 January, 2011;
originally announced January 2011.
-
CsI-THGEM gaseous photomultipliers for RICH and noble-liquid detectors
Authors:
A. Breskin,
V. Peskov,
M. Cortesi,
R. Budnik,
R. Chechik,
S. Duval,
D. Thers,
A. E. C. Coimbra,
J. M. F. dos Santos,
J. A. M. Lopes,
C. D. R. Azevedo,
J. F. C. A. Veloso
Abstract:
The properties of UV-photon imaging detectors consisting of CsI-coated THGEM electron multipliers are summarized. New results related to detection of Cherenkov light (RICH) and scintillation photons in noble liquid are presented.
The properties of UV-photon imaging detectors consisting of CsI-coated THGEM electron multipliers are summarized. New results related to detection of Cherenkov light (RICH) and scintillation photons in noble liquid are presented.
△ Less
Submitted 29 September, 2010;
originally announced September 2010.
-
The Thick-COBRA: a New Gaseous Electron Multiplier for Radiation Detectors
Authors:
F. D. Amaro,
C. Santos,
J. F. C. A. Veloso,
A. Breskin,
R. Chechik,
J. M. F. dos Santos
Abstract:
The operation principle and preliminary results of a novel gas-avalanche patterned hole electron multiplier, the Thick-COBRA (THCOBRA), are presented. This micro-hole structure is derived from the THGEM and MHSP. Sub-millimeter diameter holes are mechanically drilled in a thin G10 plate, Cu-clad on both faces; on one of the faces the Cu is etched to produce additional anode strips winding between…
▽ More
The operation principle and preliminary results of a novel gas-avalanche patterned hole electron multiplier, the Thick-COBRA (THCOBRA), are presented. This micro-hole structure is derived from the THGEM and MHSP. Sub-millimeter diameter holes are mechanically drilled in a thin G10 plate, Cu-clad on both faces; on one of the faces the Cu is etched to produce additional anode strips winding between circular cathode strips. Primary avalanches occurring within the holes are followed by additional ones at the anode-strips vicinity. Gains in excess of 5*104 were reached with 22.1 x-rays in Ar, Ne and Ar-10%CH4, with 12.2 % FWHM energy resolution in Ar-10%CH4. Higher gains were measured with single photoelectrons. This robust multiplier may have numerous potential applications.
△ Less
Submitted 4 August, 2010;
originally announced August 2010.
-
Further evaluation of a THGEM UV-photon detector for RICH - comparison with MWPC
Authors:
V. Peskov,
M. Cortesi,
R. Chechik,
A. Breskin
Abstract:
The operation of single-, double- and triple-THGEM UV-detectors with reflective CsI photocathodes (CsI-THGEM) in Ne/CH4 and Ne/CF4 mixtures was investigated in view of their potential applications in RICH. The studies were carried out with UV, x-rays and β-electrons and focused on the maximum achievable gain, discharge probability, cathode excitation effects and long-term gain stability. Comparati…
▽ More
The operation of single-, double- and triple-THGEM UV-detectors with reflective CsI photocathodes (CsI-THGEM) in Ne/CH4 and Ne/CF4 mixtures was investigated in view of their potential applications in RICH. The studies were carried out with UV, x-rays and β-electrons and focused on the maximum achievable gain, discharge probability, cathode excitation effects and long-term gain stability. Comparative studies under similar conditions were made in CH4, CF4 and Ne/CF4, with a MWPC coupled to a reflective CsI photocathode (CsI-MWPC). It was found that at counting rates <= 10 Hz/mm^2 the maximum achievable gain of CsI-THGEMs is determined by the Raether limit; at counting rates > 10 Hz/mm^2 it dropped with rate. In all cases investigated the attainable CsI-THGEM gain was significantly higher than that of the CsI-MWPC, under similar conditions. Furthermore, the CsI-THGEM UV-detector suffered fewer cathode-excitation induced effects as compared to CsI-MWPC and had better stability at high counting rates.
△ Less
Submitted 4 August, 2010; v1 submitted 1 August, 2010;
originally announced August 2010.
-
Towards THGEM UV-photon detectors for RICH: on single-photon detection efficiency in Ne/CH4 and Ne/CF4
Authors:
C. D. R. Azevedo,
M. Cortesi,
A. V. Lyashenko,
A. Breskin,
R. Chechik,
J. Miyamoto,
V. Peskov,
J. Escada,
J. F. C. A. Veloso,
J. M. F. dos Santos
Abstract:
The article deals with the detection efficiency of UV-photon detectors consisting of Thick Gas Electron Multipliers (THGEM) coated with CsI photocathode, operated in atmospheric Ne/CH4 and Ne/CF4 mixtures. We report on the photoelectron extraction efficiency from the photocathode into these gas mixtures, and on the photoelectron collection efficiency into the THGEM holes. Full collection efficie…
▽ More
The article deals with the detection efficiency of UV-photon detectors consisting of Thick Gas Electron Multipliers (THGEM) coated with CsI photocathode, operated in atmospheric Ne/CH4 and Ne/CF4 mixtures. We report on the photoelectron extraction efficiency from the photocathode into these gas mixtures, and on the photoelectron collection efficiency into the THGEM holes. Full collection efficiency was reached in all gases investigated, in some cases at relatively low multiplication. High total detector gains for UV photons, in excess of 10^5, were reached at relatively low operation voltages with a single THGEM element. We discuss the photon detection efficiency in the context of possible application to RICH.
△ Less
Submitted 29 September, 2009;
originally announced September 2009.
-
THGEM operation in Ne and Ne/CH4
Authors:
M. Cortesi,
V. Peskov,
G. Bartesaghi,
J. Miyamoto,
S. Cohen,
R. Chechik,
J. M. Maia,
J. M. F. dos Santos,
G. Gambarini,
V. Dangendorf,
A. Breskin
Abstract:
The operation of Thick Gaseous Electron Multipliers (THGEM) in Ne and Ne/CH4 mixtures, features high multiplication factors at relatively low operation potentials, in both single- and double-THGEM configurations. We present some systematic data measured with UV-photons and soft x-rays, in various Ne mixtures. It includes gain dependence on hole diameter and gas purity, photoelectron extraction e…
▽ More
The operation of Thick Gaseous Electron Multipliers (THGEM) in Ne and Ne/CH4 mixtures, features high multiplication factors at relatively low operation potentials, in both single- and double-THGEM configurations. We present some systematic data measured with UV-photons and soft x-rays, in various Ne mixtures. It includes gain dependence on hole diameter and gas purity, photoelectron extraction efficiency from CsI photocathodes into the gas, long-term gain stability and pulse rise-time. Position resolution of a 100x100 mm^2 X-rays imaging detector is presented. Possible applications are discussed.
△ Less
Submitted 19 May, 2009; v1 submitted 18 May, 2009;
originally announced May 2009.
-
Development of high-gain gaseous photomultipliers for the visible spectral range
Authors:
A. V. Lyashenko,
A. Breskin,
R. Chechik,
J. M. F. Dos Santos,
F. D. Amaro,
J. F. C. A. Veloso
Abstract:
We summarize the development of visible-sensitive gaseous photomultipliers, combining a semitransparent bi-alkali photocathode with a state-of-the-art cascaded electron multiplier. The latter has high photoelectron collection efficiency and a record ion blocking capability. We describe in details the system and methods of photocathode production and characterization, their coupling with the elec…
▽ More
We summarize the development of visible-sensitive gaseous photomultipliers, combining a semitransparent bi-alkali photocathode with a state-of-the-art cascaded electron multiplier. The latter has high photoelectron collection efficiency and a record ion blocking capability. We describe in details the system and methods of photocathode production and characterization, their coupling with the electron multiplier and the gaseous-photomultiplier operation and characterization in a continuous mode. We present results on the properties of laboratory-produced K$_2$CsSb, Cs$_3$Sb and Na$_2$KSb photocathodes and report on their stability and QE in gas; K$_2$CsSb photocathodes yielded QE values in Ar/CH$_4$(95/5) above 30% at wavelengths of 360-400 nm. The novel gaseous photomultiplier yielded stable operation at gains of 10$^5$, in continuous operation mode, in 700 Torr of this gas; its sensitivity to single photons was demonstrated. Other properties are described. The successful detection of visible light with this gas-photomultiplier pave ways towards further development of large-area sealed imaging detectors, of flat geometry, insensitive to magnetic fields, which might have significant impact on light detection in numerous fields.
△ Less
Submitted 5 May, 2009; v1 submitted 1 May, 2009;
originally announced May 2009.
-
Ion-induced secondary electron emission from K-Cs-Sb, Na-K-Sb and Cs-Sb photocathodes and its relevance to the operation of gaseous avalanche photomultipliers
Authors:
A. Lyashenko,
A. Breskin,
R. Chechik,
T. H. V. T. Dias
Abstract:
The operation of visible-sensitive gaseous- and, to some extent, vacuum-photomultipliers is critically affected by secondary electrons originating from ion impact on the photocathode. A simple method for indirect measurement of the effective ion-induced secondary-electron emission (IISEE) coefficient from the photocathode into a gas medium, $γ_+^{eff}$ was developed. The experimental results wit…
▽ More
The operation of visible-sensitive gaseous- and, to some extent, vacuum-photomultipliers is critically affected by secondary electrons originating from ion impact on the photocathode. A simple method for indirect measurement of the effective ion-induced secondary-electron emission (IISEE) coefficient from the photocathode into a gas medium, $γ_+^{eff}$ was developed. The experimental results with visible-sensitive K-Cs-Sb, Na-K-Sb and Cs-Sb photocathodes, yielded $γ_+^{eff}$ - values between 0.02 and 0.03 in Ar/CH$_{4}$ (95/5) at 700 mbar; these are in good agreement with theoretical calculations. The corresponding vacuum IISEE coefficients, $γ_+$, were estimated, based on a theoretical model, to be 0.47, 0.49 and 0.47 for K-Cs-Sb, Na-K-Sb and Cs-Sb photocathodes, respectively. The ratio of gas $γ_+^{eff}$ and vacuum $γ_+$ IISEE coefficients, calculated to be $\sim$0.06, is the fraction of secondary electrons surmounted the backscattering in the gas media.
△ Less
Submitted 30 April, 2009;
originally announced April 2009.
-
Time resolution of a Thick Gas Electron Multiplier (THGEM) - based detector
Authors:
Raz Alon,
Marco Cortesi,
Amos Breskin,
Rachel Chechik
Abstract:
The time resolution of a double-stage Thick-GEM (THGEM) detector was measured with UV-photons and relativistic electrons. The photon detector, with semitransparent- or reflective-photocathode yielded time resolution of about 8-10ns RMS for single photoelectrons and 0.5-1ns RMS for few-hundred photoelectrons per photon-pulse. Time resolution of about 10ns RMS was recorded for relativistic electro…
▽ More
The time resolution of a double-stage Thick-GEM (THGEM) detector was measured with UV-photons and relativistic electrons. The photon detector, with semitransparent- or reflective-photocathode yielded time resolution of about 8-10ns RMS for single photoelectrons and 0.5-1ns RMS for few-hundred photoelectrons per photon-pulse. Time resolution of about 10ns RMS was recorded for relativistic electrons from a 106Ru source.
△ Less
Submitted 25 September, 2008;
originally announced September 2008.
-
High-gain DC-mode operated Gaseous Photomultipliers for the visible spectral range
Authors:
A. Lyashenko,
A. Breskin,
R. Chechik,
F. D. Amaro,
J. Veloso,
J. M. F. Dos Santos
Abstract:
We shortly describe recent progress in photon detectors combining bi-alkali photocathodes and cascaded patterned gas-avalanche electron multipliers. It permitted the development and the first feasibility demonstration of high-gain gaseous photomultipliers sensitive in the visible spectral range, operated in DC mode with single-photon sensitivity.
We shortly describe recent progress in photon detectors combining bi-alkali photocathodes and cascaded patterned gas-avalanche electron multipliers. It permitted the development and the first feasibility demonstration of high-gain gaseous photomultipliers sensitive in the visible spectral range, operated in DC mode with single-photon sensitivity.
△ Less
Submitted 12 August, 2008; v1 submitted 11 August, 2008;
originally announced August 2008.
-
High pressure operation of the Photon-Assisted Cascaded Electron Multiplier
Authors:
F. D. Amaro,
J. F. C. A. Veloso,
J. M. F. dos Santos,
A. Breskin,
R. Chechik,
A. Lyashenko
Abstract:
We present the operation of the recently introduced Photon Assisted Cascaded Electron Multiplier (PACEM) in xenon at high pressure. The PACEM is a multi step electron multiplier where the VUV scintillation produced in the electron avalanches is used for signal propagation: the VUV scintillation produced in the first element of the cascade induces the emission of photoelectrons from a CsI photoca…
▽ More
We present the operation of the recently introduced Photon Assisted Cascaded Electron Multiplier (PACEM) in xenon at high pressure. The PACEM is a multi step electron multiplier where the VUV scintillation produced in the electron avalanches is used for signal propagation: the VUV scintillation produced in the first element of the cascade induces the emission of photoelectrons from a CsI photocathode placed on the top-surface of the second element. These photoelectrons are further multiplied, via charge avalanche. A metallic mesh electrode placed between the first and the second elements of the cascade completely blocks the charge transfer between them. Optical gains of 103 were achieved in xenon at atmospheric pressure, drop** to 25 at 3.3 bar, for applied voltages of 700 and 1100 V, respectively. Taking into account the subsequent charge multiplication, total gains are higher than those obtained with a triple GEM and double THGEM.
△ Less
Submitted 31 July, 2008;
originally announced July 2008.
-
Advances in Gaseous Photomultipliers
Authors:
R. Chechik,
A. Breskin
Abstract:
We review latest progress in gaseous photomultipliers (GPM) combining solid photocathodes and various types of novel electron multipliers. Cascaded gaseous electron multipliers (GEM) coated with CsI photocathodes can efficiently replace UVsensitive wire chambers for single-photon recording in Cherenkov and other detectors. Other hole-multipliers with patterned electrodes (Micro-Hole and Strip Pl…
▽ More
We review latest progress in gaseous photomultipliers (GPM) combining solid photocathodes and various types of novel electron multipliers. Cascaded gaseous electron multipliers (GEM) coated with CsI photocathodes can efficiently replace UVsensitive wire chambers for single-photon recording in Cherenkov and other detectors. Other hole-multipliers with patterned electrodes (Micro-Hole and Strip Plates) and improved ion-blocking properties are discussed; these permit reducing considerably photon- and ion-induced secondary effects. Photon detectors with other electron-multiplier techniques are briefly described, among them GPMs based on Micromegas, capillary-plates, Thick-GEMs and resistive Thick GEMs. The two latter techniques, robust and economically produced, are particularly suited for large-area GPM applications, e.g. in RICH. Cascaded hole-multipliers with very high ion-blocking performance permitted the development and the first demonstration of DC-operated visible-sensitive gaseous photomultipliers with bialkali photocathodes and single-photon sensitivity. Recent progress is described in GPMs operated at cryogenic temperatures for rare-event noble-liquid detectors and medical imaging.
△ Less
Submitted 14 July, 2008;
originally announced July 2008.
-
A concise review on THGEM detectors
Authors:
A. Breskin,
R. Alon,
M. Cortesi,
R. Chechik,
J. Miyamoto,
V. Dangendorf,
J. Maia,
J. M. F. Dos Santos
Abstract:
We briefly review the concept and properties of the Thick GEM (THGEM); it is a robust, high-gain gaseous electron multiplier, manufactured economically by standard printed-circuit drilling and etching technology. Its operation and structure resemble that of GEMs but with 5 to 20-fold expanded dimensions. The millimeter-scale hole-size results in good electron transport and in large avalanche-mul…
▽ More
We briefly review the concept and properties of the Thick GEM (THGEM); it is a robust, high-gain gaseous electron multiplier, manufactured economically by standard printed-circuit drilling and etching technology. Its operation and structure resemble that of GEMs but with 5 to 20-fold expanded dimensions. The millimeter-scale hole-size results in good electron transport and in large avalanche-multiplication factors, e.g. reaching 10^7 in double-THGEM cascaded single-photoelectron detectors. The multiplier's material, parameters and shape can be application-tailored; it can operate practically in any counting gas, including noble gases, over a pressure range spanning from 1 mbar to several bars; its operation at cryogenic (LAr) conditions was recently demonstrated. The high gain, sub-millimeter spatial resolution, high counting-rate capability, good timing properties and the possibility of industrial production capability of large-area robust detectors, pave ways towards a broad spectrum of potential applications; some are discussed here in brief.
△ Less
Submitted 13 July, 2008;
originally announced July 2008.
-
Efficient ion blocking in gaseous detectors and its application to gas-avalanche photomultipliers sensitive in the visible-light range
Authors:
A. V. Lyashenko,
A. Breskin,
R. Chechik,
J. M. F. Dos Santos,
F. D. Amaro,
J. F. C. A. Veloso
Abstract:
A novel concept for ion blocking in gas-avalanche detectors was developed, comprising cascaded micro-hole electron multipliers with patterned electrodes for ion defocusing. This leads to ion blocking at the 10^{-4} level, in DC mode, in operation conditions adequate for TPCs and for gaseous photomultipliers. The concept was validated in a cascaded visible-sensitive gas avalanche photomultiplier…
▽ More
A novel concept for ion blocking in gas-avalanche detectors was developed, comprising cascaded micro-hole electron multipliers with patterned electrodes for ion defocusing. This leads to ion blocking at the 10^{-4} level, in DC mode, in operation conditions adequate for TPCs and for gaseous photomultipliers. The concept was validated in a cascaded visible-sensitive gas avalanche photomultiplier operating at atmospheric pressure of Ar/CH_{4} (95/5) with a bi-alkali photocathode. While in previous works high gain, in excess of 10^{5}, was reached only in a pulse-gated cascaded-GEM gaseous photomultiplier, the present device yielded, for the first time, similar gain in DC mode. We describe shortly the physical processes involved in the charge transport within gaseous photomultipliers and the ion blocking method. We present results of ion backflow fraction and of electron multiplication in cascaded patterned-electrode gaseous photomultiplier with K-Cs-Sb, Na-K-Sb and Cs-Sb visible-sensitive photocathodes, operated in DC mode.
△ Less
Submitted 28 April, 2008;
originally announced April 2008.
-
Operation of a Thick Gas Electron Multiplier (THGEM) in Ar, Xe and Ar-Xe
Authors:
R. Alon,
J. Miyamoto,
M. Cortesi,
A. Breskin,
R. Chechik,
I. Carne,
J. M. Maia,
J. M. F. dos Santos,
M. Gai,
D. McKinsey,
V. Dangendorf
Abstract:
We present the results of our recent studies of a Thick Gaseous Electron Multiplier (THGEM)-based detector, operated in Ar, Xe and Ar:Xe (95:5) at various gas pressures. Avalanche-multiplication properties and energy resolution were investigated with soft x-rays for different detector configurations and parameters. Gains above 10E4 were reached in a double-THGEM detector, at atmospheric pressure…
▽ More
We present the results of our recent studies of a Thick Gaseous Electron Multiplier (THGEM)-based detector, operated in Ar, Xe and Ar:Xe (95:5) at various gas pressures. Avalanche-multiplication properties and energy resolution were investigated with soft x-rays for different detector configurations and parameters. Gains above 10E4 were reached in a double-THGEM detector, at atmospheric pressure, in all gases, in almost all the tested conditions; in Ar:Xe (95:5) similar gains were reached at pressures up to 2 bar. The energy resolution dependence on the gas, pressure, hole geometry and electric fields was studied in detail, yielding in some configurations values below 20% FWHM with 5.9 keV x-rays.
△ Less
Submitted 26 December, 2007; v1 submitted 4 December, 2007;
originally announced December 2007.
-
Investigations of a THGEM-based imaging detector
Authors:
M. Cortesi,
R. Alon,
R. Chechik,
A. Breskin,
D. Vartsky,
V. Dangendorf
Abstract:
We present the results of our recent studies on a Thick Gas Electron Multiplier (THGEM)-based imaging detector prototype. It consists of two 100x100 mm^2 THGEM electrodes in cascade, coupled to a resistive anode. The event location is recorded with a 2D double-sided readout electrode equipped with discrete delay-lines and dedicated electronics. The THGEM electrodes, produced by standard printed-…
▽ More
We present the results of our recent studies on a Thick Gas Electron Multiplier (THGEM)-based imaging detector prototype. It consists of two 100x100 mm^2 THGEM electrodes in cascade, coupled to a resistive anode. The event location is recorded with a 2D double-sided readout electrode equipped with discrete delay-lines and dedicated electronics. The THGEM electrodes, produced by standard printed-circuit board and mechanical drilling techniques, a 0.4 mm thick with 0.5 mm diameter holes spaced by 1 mm. Localization resolutions of about 0.7 mm (FWHM) were measured with soft x-rays, in a detector operated with atmospheric-pressure Ar/CH4; good linearity and homogeneity were achieved. We describe the imaging-detector layout, the resistive-anode 2D readout system and the imaging properties. The THGEM has numerous potential applications that require large-area imaging detectors, with high-rate capability, single-electron sensitivity and moderate (sub-mm) localization resolution.
△ Less
Submitted 26 December, 2007; v1 submitted 22 July, 2007;
originally announced July 2007.
-
Further progress in ion back-flow reduction with patterned gaseous hole-multipliers
Authors:
A. V. Lyashenko,
A. Breskin,
R. Chechik,
J. F. C. A. Veloso,
J. M. F. Dos Santos,
F. D. Amaro
Abstract:
A new idea on electrostatic deviation and capture of back-drifting avalanche-ions in cascaded gaseous hole-multipliers is presented. It involves a flipped reversed-bias Micro-Hole & Strip Plate (F-R-MHSP) element, the strips of which are facing the drift region of the multiplier. The ions, originating from successive multiplication stages, are efficiently deviated and captured by such electrode.…
▽ More
A new idea on electrostatic deviation and capture of back-drifting avalanche-ions in cascaded gaseous hole-multipliers is presented. It involves a flipped reversed-bias Micro-Hole & Strip Plate (F-R-MHSP) element, the strips of which are facing the drift region of the multiplier. The ions, originating from successive multiplication stages, are efficiently deviated and captured by such electrode. Experimental results are provided comparing the ion-blocking capability of the F-R-MHSP to that of the reversed-bias Micro-Hole & Strip Plate (R-MHSP) and the Gas Electron Multiplier (GEM). Best ion-blocking results in cascaded hole-multipliers were reached with a detector having the F-R-MHSP as the first multiplication element. A three-element F-R-MHSP/GEM/MHSP cascaded multiplier operated in atmospheric-pressure Ar/CH4 (95/5), at total gain of ~10^{5}, yielded ion back-flow fractions of 3*10^{-4} and 1.5*10^{-4}, at drift fields of 0.5 and 0.2 kV/cm, respectively. We describe the F-R-MHSP concept and the relevance of the obtained ion back-flow fractions to various applications; further ideas are also discussed.
△ Less
Submitted 14 August, 2007; v1 submitted 25 June, 2007;
originally announced June 2007.
-
Advances in ion back-flow reduction in cascaded gaseous electron multipliers incorporating R-MHSP elements
Authors:
A. V. Lyashenko,
A. Breskin,
R. Chechik,
J. F. C. A. Veloso,
J. M. F. Dos Santos,
F. D. Amaro
Abstract:
A new concept is presented for the reduction of ion back-flow in GEM-based cascaded gaseous electron multipliers, by incorporating Micro-Hole & Strip Plate (MHSP) elements operating in reversed-bias mode (R-MHSP). About an order of magnitude reduction in ion back-flow is achieved by diverting back-drifting ions from their original path. A R-MHSP/2GEM/MHSP cascaded multiplier operated at total ga…
▽ More
A new concept is presented for the reduction of ion back-flow in GEM-based cascaded gaseous electron multipliers, by incorporating Micro-Hole & Strip Plate (MHSP) elements operating in reversed-bias mode (R-MHSP). About an order of magnitude reduction in ion back-flow is achieved by diverting back-drifting ions from their original path. A R-MHSP/2GEM/MHSP cascaded multiplier operated at total gain of ~1.5*10^5 yielded ion back-flow fractions of 0.0015 and 0.0004, at drift fields of 0.5 and 0.1 kV/cm, respectively. A 2R-MHSP/MHSP cascaded multiplier operated at a total gain of ~10^5, yielded an ion back-flow fraction of 0.003. We discuss the concept for trap** back-flowing ions in these cascaded multipliers and the relevance to gaseous photomultiplier and TPC applications; directions for further future developments are outlined.
△ Less
Submitted 3 July, 2006;
originally announced July 2006.
-
Advances in imaging THGEM-based detectors
Authors:
M. Cortesi,
R. Chechik,
A. Breskin,
G. Guedes,
V. Dangendorf,
D. Vartzky,
D. Bar
Abstract:
The thick GEM (THGEM) [1] is an "expanded" GEM, economically produced in the PCB industry by simple drilling and etching in G-10 or other insulating materials (fig. 1). Similar to GEM, its operation is based on electron gas avalanche multiplication in sub-mm holes, resulting in very high gain and fast signals. Due to its large hole size, the THGEM is particularly efficient in transporting the el…
▽ More
The thick GEM (THGEM) [1] is an "expanded" GEM, economically produced in the PCB industry by simple drilling and etching in G-10 or other insulating materials (fig. 1). Similar to GEM, its operation is based on electron gas avalanche multiplication in sub-mm holes, resulting in very high gain and fast signals. Due to its large hole size, the THGEM is particularly efficient in transporting the electrons into and from the holes, leading to efficient single-electron detection and effective cascaded operation. The THGEM provides true pixilated radiation localization, ns signals, high gain and high rate capability. For a comprehensive summary of the THGEM properties, the reader is referred to [2, 3]. In this article we present a summary of our recent study on THGEM-based imaging, carried out with a 10x10 cm^2 double-THGEM detector.
△ Less
Submitted 25 June, 2006;
originally announced June 2006.
-
The Photon-Assisted Cascaded Electron Multiplier: a Concept for Potential Avalanche-Ion Blocking
Authors:
J. F. C. A. Veloso,
F. D. Amaro,
J. M. F. dos Santos,
A. Breskin,
A. Lyashenko,
R. Chechik
Abstract:
We present a Photon-Assisted Cascaded Electron Multipliers (PACEM) which has a potential for ion back-flow blocking in gaseous radiation detectors: the avalanche from a first multiplication stage propagates to the successive one via its photons, which in turn induce photoelectron emission from a photocathode deposited on the second multiplier stage; the multiplication process may further continu…
▽ More
We present a Photon-Assisted Cascaded Electron Multipliers (PACEM) which has a potential for ion back-flow blocking in gaseous radiation detectors: the avalanche from a first multiplication stage propagates to the successive one via its photons, which in turn induce photoelectron emission from a photocathode deposited on the second multiplier stage; the multiplication process may further continue via electron-avalanche propagation. The photon-mediated stage allows, by a proper choice of geometry and fields, complete blocking of the ion back-flow into the first element; thus, only ions from the latter will flow back to the drift region. The PACEM concept was validated in a double-MHSP (Micro-Hole & Strip Plate) cascaded multiplier operated in xenon, where the intermediate scintillation stage provided optical gain of ~60. The double-MHSP detector had a total gain above 10^4 and energy resolution of 18% FWHM for 5.9 keV x-rays.
△ Less
Submitted 25 June, 2006;
originally announced June 2006.
-
Thick GEM-like (THGEM) detectors and their possible applications
Authors:
R. Chechik,
M. Cortesi,
A. Breskin,
D. Vartsky,
D. Bar,
V. Dangendorf
Abstract:
Thick GEM-like (THGEM) electrodes are robust, high gain gaseous electron multipliers, economically-manufactured by standard drilling and etching of thin printed circuit board or other materials. Their operation and structure are similar to that of standard GEMs but with 5 to 20-fold expanded dimensions. Due to the larger hole dimensions they provide up to 10^5 and 10^7 charge multiplication, in…
▽ More
Thick GEM-like (THGEM) electrodes are robust, high gain gaseous electron multipliers, economically-manufactured by standard drilling and etching of thin printed circuit board or other materials. Their operation and structure are similar to that of standard GEMs but with 5 to 20-fold expanded dimensions. Due to the larger hole dimensions they provide up to 10^5 and 10^7 charge multiplication, in a single- and in two-electrode cascade, respectively. The signal rise time is of a few ns and the counting-rate capability approaches 10 MHz/mm^2 at 10^4 gains. Sub-mm localization precision was demonstrated with a simple, delay-line based 2D readout scheme. These multipliers may be produced in a variety of shapes and sizes and can operate in many gases. They may replace the standard GEMs in many applications requiring very large area, robust, flat, thin detectors, with good timing and counting-rate properties and modest localization. The properties of these multipliers are presented in short and possible applications are discussed.
△ Less
Submitted 18 June, 2006;
originally announced June 2006.
-
Amplification and Scintillation Properties of Oxygen-Rich Gas Mixtures for Optical-TPC Applications
Authors:
L. Weissman,
M. Gai,
A. Breskin,
R. Chechik,
V. Dangendorf,
K. Tittelmeier,
H. R. Weller
Abstract:
We studied electron amplification and light emission from avalanches in oxygen-containing gas mixtures. The mixtures investigated in this work included, among others, CO2 and N2O mixed with Triethylamine (TEA) or N2. Double-Step Parallel Gap (DSPG) multipliers and THick Gas Electron Multipliers (THGEM) were investigated. High light yields were measured from CO2+N2 and CO2+TEA, though with differ…
▽ More
We studied electron amplification and light emission from avalanches in oxygen-containing gas mixtures. The mixtures investigated in this work included, among others, CO2 and N2O mixed with Triethylamine (TEA) or N2. Double-Step Parallel Gap (DSPG) multipliers and THick Gas Electron Multipliers (THGEM) were investigated. High light yields were measured from CO2+N2 and CO2+TEA, though with different emission spectra. We observed the characteristic wave-length emission of N2 and of TEA and used a polymer wave-length shifter to convert TEA UV-light into the visible spectrum. The results of these measurements indicate the applicability of optical recording of ionizing tracks in a TPC target-detector designed to study the cross section of the 16O(g,a)12C reaction, a central problem in nuclear astrophysics.
△ Less
Submitted 27 May, 2006; v1 submitted 27 February, 2006;
originally announced February 2006.
-
Map** the Sensitive Volume of an Ion-Counting Nanodosimeter
Authors:
Reinhard Schulte,
Vladimir Bashkirov,
Sergei Shchemelinin,
Amos Breskin,
Rachel Chechik,
Guy Garty,
Andrew Wroe,
Bernd Grosswendt
Abstract:
We present two methods of independently map** the dimensions of the sensitive volume in an ion-counting nanodosimeter. The first method is based on a calculational approach simulating the extraction of ions from the sensitive volume, and the second method on probing the sensitive volume with 250 MeV protons. Sensitive-volume maps obtained with both methods are compared and systematic errors in…
▽ More
We present two methods of independently map** the dimensions of the sensitive volume in an ion-counting nanodosimeter. The first method is based on a calculational approach simulating the extraction of ions from the sensitive volume, and the second method on probing the sensitive volume with 250 MeV protons. Sensitive-volume maps obtained with both methods are compared and systematic errors inherent in both methods are quantified.
△ Less
Submitted 22 January, 2006;
originally announced January 2006.
-
Operation of MHSP multipliers in high pressure pure noble-gas
Authors:
F. D. Amaro,
J. F. C. A. Veloso,
A. Breskin,
R. Chechik,
J. M. F. dos Santos
Abstract:
We report on the performance of a Micro-Hole & Strip Plate (MHSP) electron multiplier operating in pure Xe, Kr, Ar and Ne at the pressure range of 1 to 6 bar. The maximal gains at 1 bar Xe and Kr are 50000 and 100000, respectively; they drop by about one order of magnitude at 2 bar and by almost another order of magnitude at 5-6 bar; they reach gains of 500 and 4000 at 5 bar in Xe and Kr, respec…
▽ More
We report on the performance of a Micro-Hole & Strip Plate (MHSP) electron multiplier operating in pure Xe, Kr, Ar and Ne at the pressure range of 1 to 6 bar. The maximal gains at 1 bar Xe and Kr are 50000 and 100000, respectively; they drop by about one order of magnitude at 2 bar and by almost another order of magnitude at 5-6 bar; they reach gains of 500 and 4000 at 5 bar in Xe and Kr, respectively. In Ar, the gain varies very little with pressure, being 3000-9000; in Ne the maximum attainable gain, about 100000, is pressure independent above 2 bar. The results are compared with that of single- and triple-GEM multipliers operated in similar conditions. Potential applications are in hard X-ray imaging and in cryogenic radiation detectors.
△ Less
Submitted 17 January, 2006;
originally announced January 2006.
-
Advances in Thick GEM-like gaseous electron multipliers. Part II: low-pressure operation
Authors:
C. K. Shalem,
R. Chechik,
A. Breskin,
K. Michaeli,
N. Ben-Haim
Abstract:
We present results on THGEM operation at low gas pressures, in the range 0.5-50 Torr. Gaseous gain up to 100000 was recorded at 10 Torr of Isobutane in a single multiplier element, with pulses rise-time in the few ns range. Cascaded operation of two THGEMs is reported, with similar total gain but at lower voltages on each element. The present work encompasses a large variety of THGEM geometries…
▽ More
We present results on THGEM operation at low gas pressures, in the range 0.5-50 Torr. Gaseous gain up to 100000 was recorded at 10 Torr of Isobutane in a single multiplier element, with pulses rise-time in the few ns range. Cascaded operation of two THGEMs is reported, with similar total gain but at lower voltages on each element. The present work encompasses a large variety of THGEM geometries and includes electric-field distribution calculations and electron transport simulations. We discuss the operation mechanism and some possible applications of THGEMs at low gas pressures.
△ Less
Submitted 17 January, 2006;
originally announced January 2006.
-
Advances in Thick GEM-like gaseous electron multipliers. Part I: atmospheric pressure operation
Authors:
C. Shalem,
R. Chechik,
A. Breskin,
K. Michaeli
Abstract:
Thick GEM-like (THGEM) gaseous electron multipliers are made of standard printed-circuit board perforated with sub-millimeter diameter holes, etched at their rims. Effective gas multiplication factors of 100000 and 10000000 and fast pulses in the few nanosecond rise-time scale were reached in single- and cascaded double-THGEM elements, in atmospheric-pressure standard gas mixtures with single ph…
▽ More
Thick GEM-like (THGEM) gaseous electron multipliers are made of standard printed-circuit board perforated with sub-millimeter diameter holes, etched at their rims. Effective gas multiplication factors of 100000 and 10000000 and fast pulses in the few nanosecond rise-time scale were reached in single- and cascaded double-THGEM elements, in atmospheric-pressure standard gas mixtures with single photoelectrons. High single-electron detection efficiency is obtained in photon detectors combining THGEMs and semitransparent UV-sensitive CsI photocathodes or reflective ones deposited on the top THGEM face; the latter benefits of a reduced sensitivity to ionizing background radiation. Stable operation was recorded with photoelectron fluxes exceeding MHz/mm2. The properties and some potential applications of these simple and robust multipliers are discussed.
△ Less
Submitted 17 January, 2006;
originally announced January 2006.
-
Optical Readout Time Projection Chamber (O-TPC) for a Study of Oxygen Formation In Stellar Helium Burning
Authors:
Moshe Gai,
Amos Breskin,
Rachel Chechik,
Volker Dangendorf,
Henry R. Weller
Abstract:
We are develo** an Optical Readout Time Projection Chamber (O-TPC) detector for the study of the 12C(a,g)16O reaction that determines the ratio of carbon to oxygen in helium burning. This ratio is crucial for understanding the final fate of a progenitor star and the nucleosynthesis of elements prior to a Type II supernova; an oxygen rich star is predicted to collapse to a black hole, and a car…
▽ More
We are develo** an Optical Readout Time Projection Chamber (O-TPC) detector for the study of the 12C(a,g)16O reaction that determines the ratio of carbon to oxygen in helium burning. This ratio is crucial for understanding the final fate of a progenitor star and the nucleosynthesis of elements prior to a Type II supernova; an oxygen rich star is predicted to collapse to a black hole, and a carbon rich star to a neutron star. Type Ia supernovae (SNeIa) are used as standard candles for measuring cosmological distances with the use of an empirical light curve-luminosity stretching factor. It is essential to understand helium burning that yields the carbon/oxygen white dwarf and thus the initial stage of SNeIa. The O-TPC is intended for use with high intensity photon beams extracted from the HIgS/TUNL facility at Duke University to study the 16O(g,a)12C reaction, and thus the direct reaction at energies as low as 0.7 MeV. We are conducting a systematical study of the best oxygen containing gas with light emitting admixture(s) for use in such an O-TPC. Preliminary results with CO_2 + TEA mixture were obtained
△ Less
Submitted 1 April, 2005;
originally announced April 2005.
-
MHSP in reversed-biased operation mode for ion blocking in gas-avalanche multipliers
Authors:
J. F. C. A. Veloso,
F. Amaro,
J. M. Maia,
A. V. Lyashenko,
A. Breskin,
R. Chechik,
J. M. F. dos Santos,
O. Bouianov,
M. Bouianov
Abstract:
We present recent results on the operation of gas-avalanche detectors comprising a cascade of gas electron multipliers (GEMs) and Micro-Hole and Strip Plates (MHSPs) multiplier operated in reversed-bias (R-MHSP) mode. The operation mechanism of the R-MHSP is explained and its potential contribution to ion-backflow (IBF) reduction is demonstrated. IBF values of 4E-3 were obtained in cascaded R-MH…
▽ More
We present recent results on the operation of gas-avalanche detectors comprising a cascade of gas electron multipliers (GEMs) and Micro-Hole and Strip Plates (MHSPs) multiplier operated in reversed-bias (R-MHSP) mode. The operation mechanism of the R-MHSP is explained and its potential contribution to ion-backflow (IBF) reduction is demonstrated. IBF values of 4E-3 were obtained in cascaded R-MHSP and GEM multipliers at gains of about 1E+4, though at the expense of reduced effective gain in the first R- MHSP multiplier in the cascade.
△ Less
Submitted 31 March, 2005;
originally announced March 2005.
-
Ion-induced effects in GEM & GEM/MHSP gaseous photomultipliers for the UV and the visible spectral range
Authors:
A. Breskin,
D. Mormann,
A. Lyashenko,
R. Chechik,
F. D. Amaro,
J. M. Maia,
J. F. C. A. Veloso,
J. M. F. dos Santos
Abstract:
We report on the progress in the study of cascaded GEM and GEM/MHSP gas avalanche photomultipliers operating at atmospheric pressure, with CsI and bialkali photocathodes. They have single-photon sensitivity, ns time resolution and good localization properties. We summarize operational aspects and results, with the highlight of a high-gain stable gated operation of a visible-light device. Of part…
▽ More
We report on the progress in the study of cascaded GEM and GEM/MHSP gas avalanche photomultipliers operating at atmospheric pressure, with CsI and bialkali photocathodes. They have single-photon sensitivity, ns time resolution and good localization properties. We summarize operational aspects and results, with the highlight of a high-gain stable gated operation of a visible-light device. Of particular importance are the results of a recent ion-backflow reduction study in different cascaded multipliers, affecting the detector's stability and the photocathode's liftime. We report on the significant progress in ion-blocking and provide first results on bialkali-photocathode aging under gas multiplication.
△ Less
Submitted 24 February, 2005;
originally announced February 2005.
-
Thick GEM-like multipliers - a simple solution for large area UV-RICH detectors
Authors:
R. Chechik,
A. Breskin,
C. Shalem
Abstract:
We report on the properties of thick GEM-like (THGEM) electron multipliers made of 0.4 mm thick double-sided Cu-clad G-10 plates, perforated with a dense hexagonal array of 0.3 mm diameter drilled holes. Photon detectors comprising THGEMs coupled to semi-transparent CsI photocathodes or reflective ones deposited on the THGEM surface were studied with Ar/CO2 (70:30), Ar/CH4 (95:5), CH4 and CF4. G…
▽ More
We report on the properties of thick GEM-like (THGEM) electron multipliers made of 0.4 mm thick double-sided Cu-clad G-10 plates, perforated with a dense hexagonal array of 0.3 mm diameter drilled holes. Photon detectors comprising THGEMs coupled to semi-transparent CsI photocathodes or reflective ones deposited on the THGEM surface were studied with Ar/CO2 (70:30), Ar/CH4 (95:5), CH4 and CF4. Gains of ~100000 or exceeding 1000000 were reached with single- or double-THGEM, respectively; the signals have 5-10 ns rise times. The electric field configurations at the THGEM electrodes result in an efficient extraction of photoelectrons and their focusing into the holes; this occurs already at rather low gains, below 100. These detectors, with single-photon sensitivity and with expected sub-millimeter localization, can operate at MHz/mm2 rates. We discuss their prospects for large-area UV-photon imaging for RICH.
△ Less
Submitted 24 February, 2005;
originally announced February 2005.
-
A time projection chamber with optical readout for charged particle track structure imaging
Authors:
U. Titt,
A. Breskin,
R. Chechik,
V. Dangendorf,
H. Schmidt-Boecking,
H. Schuhmacher
Abstract:
We report about a nuclear track imaging system which is designed to study in detail the ionization topology of charged particle tracks in a low-pressure gas. The detection method is based on a time projection chamber (TPC) filled with low-pressure triethylamine (TEA). Ionization electrons produced by energetic charged particles are three-dimensionally imaged by recording light from electron aval…
▽ More
We report about a nuclear track imaging system which is designed to study in detail the ionization topology of charged particle tracks in a low-pressure gas. The detection method is based on a time projection chamber (TPC) filled with low-pressure triethylamine (TEA). Ionization electrons produced by energetic charged particles are three-dimensionally imaged by recording light from electron avalanches with an intensified CCD system. The detector permits to inves-tigate the spatial ionization distributions of particle tracks in gas, of equivalent length and resolution in tissue of 4 mm and 40 nm (RMS), respectively. We explain the relevance of this technique for dosimetry, describe the experimental method and the basic operation parameters. First results of the chamber response to protons and alpha particles are presented.
△ Less
Submitted 27 October, 2004;
originally announced October 2004.
-
Time-resolved fast neutron imaging: simulation of detector performance
Authors:
D. Vartsky,
I. Mor,
M. B. Goldberg,
I. Mardor,
G. Feldman,
D. Bar,
A. Shor,
V. Dangendorf,
G. Laczko,
A. Breskin,
R. Chechik
Abstract:
We have analyzed and compared the performance of two novel fast-neutron imaging methods with time-of-flight spectroscopy capability. Using MCNP and GEANT code simulations of neutron and charged-particle transport in the detectors, key parameters such as detection efficiency, the amount of energy deposited in the converter and the spatial resolution of both detector variants have been evaluated.
We have analyzed and compared the performance of two novel fast-neutron imaging methods with time-of-flight spectroscopy capability. Using MCNP and GEANT code simulations of neutron and charged-particle transport in the detectors, key parameters such as detection efficiency, the amount of energy deposited in the converter and the spatial resolution of both detector variants have been evaluated.
△ Less
Submitted 17 August, 2004;
originally announced August 2004.
-
Detectors for Time-of-Flight Fast-Neutron Radiography: 1. Neutron Counting Gas Detector
Authors:
V. Dangendorf,
A. Breskin,
R. Chechik,
M. Goldberg,
G. Laczko,
I. Mor,
M. Reginatto,
D. Vartsky
Abstract:
One of our two methods for fast-neutron imaging with spectrometric capability is presented here. It is a neutron-counting technique based on a hydrogenous neutron converter coupled to Gaseous Electron Multipliers (GEM). The principles of the detection techniques and the optimization of the converter, electron amplification and the readout are described. Evaluation of the properties are derived f…
▽ More
One of our two methods for fast-neutron imaging with spectrometric capability is presented here. It is a neutron-counting technique based on a hydrogenous neutron converter coupled to Gaseous Electron Multipliers (GEM). The principles of the detection techniques and the optimization of the converter, electron amplification and the readout are described. Evaluation of the properties are derived from a experiment in a pulsed neutron beam of spectral distribution between 2 and 10 MeV
△ Less
Submitted 17 August, 2004;
originally announced August 2004.
-
Thick GEM-like hole multipliers: properties and possible applications
Authors:
R. Chechik,
A. Breskin,
C. Shalem,
D. Moermann
Abstract:
The properties of thick GEM-like (TGEM) gaseous electron multipliers, operated at 1-740 Torr are presented. They are made of a G-10 plate, perforated with millimeter-scale diameter holes. In single-multiplier elements, effective gains of about 104, 106, and 105 were reached at respective pressures of 1, 10 Torr isobutane and 740 Torr Ar/5%CH4, with pulse rise-times in the few nanosecond scale. T…
▽ More
The properties of thick GEM-like (TGEM) gaseous electron multipliers, operated at 1-740 Torr are presented. They are made of a G-10 plate, perforated with millimeter-scale diameter holes. In single-multiplier elements, effective gains of about 104, 106, and 105 were reached at respective pressures of 1, 10 Torr isobutane and 740 Torr Ar/5%CH4, with pulse rise-times in the few nanosecond scale. The high effective gain at atmospheric pressure was measured with a TGEM coated with a CsI photocathode. The detector was operated in single and cascaded modes. Potential applications in ion and photon detection are discussed.
△ Less
Submitted 28 April, 2004; v1 submitted 26 April, 2004;
originally announced April 2004.
-
Detectors for Energy-Resolved Fast Neutron Imaging
Authors:
V. Dangendorf,
A. Breskin,
R. Chechik,
G. Feldman,
M. B. Goldberg,
O. Jagutzki,
C. Kersten,
G. Laczko,
I. Mor,
U. Spillman,
D. Vartsky
Abstract:
Two detectors for energy-resolved fast-neutron imaging in pulsed broad-energy neutron beams are presented. The first one is a neutron-counting detector based on a solid neutron converter coupled to a gaseous electron multiplier (GEM). The second is an integrating imaging technique, based on a scintillator for neutron conversion and an optical imaging system with fast framing capability.
Two detectors for energy-resolved fast-neutron imaging in pulsed broad-energy neutron beams are presented. The first one is a neutron-counting detector based on a solid neutron converter coupled to a gaseous electron multiplier (GEM). The second is an integrating imaging technique, based on a scintillator for neutron conversion and an optical imaging system with fast framing capability.
△ Less
Submitted 25 March, 2004;
originally announced March 2004.
-
Recent Investigations of Cascaded GEM and MHSP detectors
Authors:
R. Chechik,
A. Breskin,
G. P. Guedes,
D. Moermann,
J. Maia,
V. Dangendorf,
D. Vartzky,
J. M. F. Dos Santos,
J. F. C. A. Veloso
Abstract:
We present results from our recent investigations on detectors comprising cascaded gas electron multipliers (GEM) and cascaded GEMs with micro-hole and strip (MHSP) electrodes. We discuss the factors governing the operation of these fast radiation imaging detectors, that have single-charge sensitivity. The issue of ion-backflow and ion-induced secondary effects is discussed in some detail, prese…
▽ More
We present results from our recent investigations on detectors comprising cascaded gas electron multipliers (GEM) and cascaded GEMs with micro-hole and strip (MHSP) electrodes. We discuss the factors governing the operation of these fast radiation imaging detectors, that have single-charge sensitivity. The issue of ion-backflow and ion-induced secondary effects is discussed in some detail, presenting ways for its reduction and suppression. Applications are presented in the fields of photon imaging in the UV-to-visible spectral range as well as x-ray and neutron imaging.
△ Less
Submitted 24 November, 2003;
originally announced November 2003.