Exploring Automated Contouring Across Institutional Boundaries: A Deep Learning Approach with Mouse Micro-CT Datasets
Authors:
Lu Jiang,
Di Xu,
Qifan Xu,
Arion Chatziioannou,
Keisuke S. Iwamoto,
Susanta Hui,
Ke Sheng
Abstract:
Image-guided mouse irradiation is essential to understand interventions involving radiation prior to human studies. Our objective is to employ Swin UNEt Transformers (Swin UNETR) to segment native micro-CT and contrast-enhanced micro-CT scans and benchmark the results against 3D no-new-Net (nnU-Net). Swin UNETR reformulates mouse organ segmentation as a sequence-to-sequence prediction task, using…
▽ More
Image-guided mouse irradiation is essential to understand interventions involving radiation prior to human studies. Our objective is to employ Swin UNEt Transformers (Swin UNETR) to segment native micro-CT and contrast-enhanced micro-CT scans and benchmark the results against 3D no-new-Net (nnU-Net). Swin UNETR reformulates mouse organ segmentation as a sequence-to-sequence prediction task, using a hierarchical Swin Transformer encoder to extract features at 5 resolution levels, and connects to a Fully Convolutional Neural Network (FCNN)-based decoder via skip connections. The models were trained and evaluated on open datasets, with data separation based on individual mice. Further evaluation on an external mouse dataset acquired on a different micro-CT with lower kVp and higher imaging noise was also employed to assess model robustness and generalizability. Results indicate that Swin UNETR consistently outperforms nnU-Net and AIMOS in terms of average dice similarity coefficient (DSC) and Hausdorff distance (HD95p), except in two mice of intestine contouring. This superior performance is especially evident in the external dataset, confirming the model's robustness to variations in imaging conditions, including noise and quality, thereby positioning Swin UNETR as a highly generalizable and efficient tool for automated contouring in pre-clinical workflows.
△ Less
Submitted 28 May, 2024;
originally announced May 2024.
GATE : a simulation toolkit for PET and SPECT
Authors:
S. Jan,
G. Santin,
D. Strul,
S. Staelens,
K. Assie,
D. Autret,
S. Avner,
R. Barbier,
M. Bardies,
P. M. Bloomfield,
D. Brasse,
V. Breton,
P. Bruyndonckx,
I. Buvat,
A. F. Chatziioannou,
Y. Choi,
Y. H. Chung,
C. Comtat,
D. Donnarieix,
L. Ferrer,
S. J. Glick,
C. J. Groiselle,
D. Guez,
P. -F. Honore,
S. Kerhoas-Cavata
, et al. (28 additional authors not shown)
Abstract:
Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols, and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted…
▽ More
Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols, and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted simulation toolkit adapted to the field of nuclear medicine. In particular, GATE allows the description of time-dependent phenomena such as source or detector movement, and source decay kinetics. This feature makes it possible to simulate time curves under realistic acquisition conditions and to test dynamic reconstruction algorithms. A public release of GATE licensed under the GNU Lesser General Public License can be downloaded at the address http://www-lphe.epfl.ch/GATE/.
△ Less
Submitted 24 August, 2004;
originally announced August 2004.