-
Optical control and coherent coupling of spin diffusive modes in thermal gases
Authors:
P. Bevington,
J. Nicholson,
J. D. Zipfel,
W. Chalupczak,
C. Mishra,
V. Guarrera
Abstract:
Collective spins in thermal gases are at the core of a multitude of science and technology applications. In most of them, the random thermal motion of the particles is considered detrimental as it is responsible for decoherence and noise. In conditions of diffusive propagation, thermal atoms can potentially occupy various stable spatial modes in a glass cell. Extended or localized, diffusive modes…
▽ More
Collective spins in thermal gases are at the core of a multitude of science and technology applications. In most of them, the random thermal motion of the particles is considered detrimental as it is responsible for decoherence and noise. In conditions of diffusive propagation, thermal atoms can potentially occupy various stable spatial modes in a glass cell. Extended or localized, diffusive modes have different magnetic properties, depending on the boundary conditions of the atomic cell, and can react differently to external perturbations. Here we demonstrate that few of these modes can be selectively excited, manipulated, and interrogated in atomic thermal vapours using laser light. In particular, we individuate the conditions for the generation of modes that are exceptionally resilient to undesirable effects introduced by optical pum**, such as light shifts and power-broadening, which are often the dominant sources of systematic errors in atomic magnetometers and co-magnetometers. Moreover, we show that the presence of spatial inhomogeneity in the pump, on top of the random diffusive atomic motion, introduces a coupling that leads to a coherent exchange of excitation between the two longest-lived modes. Our results indicate that systematic engineering of the multi-mode nature of diffusive gases has great potential for improving the performance of quantum technology applications based on alkali-metal thermal gases, and promote these simple experimental systems as versatile tools for quantum information applications.
△ Less
Submitted 26 February, 2024;
originally announced February 2024.
-
Indirect pum** of alkali-metal gases in a miniature silicon-wafer cell
Authors:
J. D. Zipfel,
P. Bevington,
L. Wright,
W. Chalupczak,
G. Quick,
B. Steele,
J. Nicholson,
V. Guarrera
Abstract:
Atom spin sensors occupy a prominent position in the scenario of quantum technology, as they can combine precise measurements with appealing miniature packages which are crucial for many applications. In this work, we report on the design and realization of miniature silicon-wafer cells, with a double-chamber configuration and integrated heaters. The cells are tested by systematically studying the…
▽ More
Atom spin sensors occupy a prominent position in the scenario of quantum technology, as they can combine precise measurements with appealing miniature packages which are crucial for many applications. In this work, we report on the design and realization of miniature silicon-wafer cells, with a double-chamber configuration and integrated heaters. The cells are tested by systematically studying the spin dynamics dependence on the main pump parameters, temperature, and bias magnetic field. The results are benchmarked against cm-sized paraffin-coated cells, which allows for optimisation of operating conditions of a radio-frequency driven atomic magnetometer. In particular, we observe that, when indirect optical pum** is performed on the two cells, an analogous line narrowing mechanism appears in otherwise very different cells' conditions. Competitive results are obtained, with magnetic resonance linewidths of roughly 100 Hz at the maximum signal-to-noise ratio, in a non-zero magnetic field setting, and in an atomic shot-noise limited regime.
△ Less
Submitted 26 February, 2024;
originally announced February 2024.
-
Polarisation of radio-frequency magnetic fields in magnetic induction measurements with an atomic magnetometer
Authors:
L. M. Rushton,
L. M. Ellis,
J. D. Zipfel,
P. Bevington,
W. Chalupczak
Abstract:
We explore properties of the radio-frequency atomic magnetometer, specifically its sensitivity to the polarisation of an oscillating magnetic field. This aspect can be particularly relevant to configurations where the sensor monitors fields created by more than one source. The discussion, illustrated by theoretical and experimental studies, is done in the context of the signals produced by electri…
▽ More
We explore properties of the radio-frequency atomic magnetometer, specifically its sensitivity to the polarisation of an oscillating magnetic field. This aspect can be particularly relevant to configurations where the sensor monitors fields created by more than one source. The discussion, illustrated by theoretical and experimental studies, is done in the context of the signals produced by electrically conductive and magnetically permeable plates in magnetic induction tomography measurements. We show that different components of the secondary magnetic fields create the object response depending on the properties of the material, with the polarisation of the rf field varying across the object's surface. We argue that the ability of the sensor to simultaneously detect different field components enables the optimisation of measurement strategies for different object compositions.
△ Less
Submitted 5 January, 2024;
originally announced January 2024.
-
Identification of object composition with Magnetic Inductive Tomography
Authors:
R. Gartman,
W. Chalupczak
Abstract:
The inductive response of an object to an oscillating magnetic field reveals information about its electrical conductivity and magnetic permeability. Here we introduce a technique that uses measurements of the angular, frequency and spatial dependence of the inductive signal to determine object composition. Identification is performed by referencing an object's inductive response to that of materi…
▽ More
The inductive response of an object to an oscillating magnetic field reveals information about its electrical conductivity and magnetic permeability. Here we introduce a technique that uses measurements of the angular, frequency and spatial dependence of the inductive signal to determine object composition. Identification is performed by referencing an object's inductive response to that of materials with mutually exclusive properties such as copper (high electric conductivity, negligible magnetic permeability) and ferrite (negligible electric conductivity, high magnetic permeability). The technique uses a sensor with anisotropic sensitivity to discriminate between the different characters of the eddy current and magnetisation driven object responses. Experimental validation of the method is performed through Magnetic Induction Tomography measurement with a radio-frequency atomic magnetometer. Possible applications of the technique in security screening devices are discussed.
△ Less
Submitted 9 September, 2021;
originally announced September 2021.
-
Spin noise spectroscopy of a noise-squeezed atomic state
Authors:
V. Guarrera,
R. Gartman,
G. Bevilacqua,
W. Chalupczak
Abstract:
Spin noise spectroscopy is emerging as a powerful technique for studying the dynamics of various spin systems also beyond their thermal equilibrium and linear response. Here, we study spin fluctuations of room-temperature neutral atoms in a Bell-Bloom type magnetometer. Driven by indirect pum** and undergoing a parametric excitation, this system is known to produce noise-squeezing. Our measureme…
▽ More
Spin noise spectroscopy is emerging as a powerful technique for studying the dynamics of various spin systems also beyond their thermal equilibrium and linear response. Here, we study spin fluctuations of room-temperature neutral atoms in a Bell-Bloom type magnetometer. Driven by indirect pum** and undergoing a parametric excitation, this system is known to produce noise-squeezing. Our measurements not only reveal a strong asymmetry in the noise distribution of the atomic signal quadratures at the magnetic resonance, but also provide insight into the mechanism behind its generation and evolution. In particular, a structure in the spectrum is identified which allows to investigate the main dependencies and the characteristic timescales of the noise process. The results obtained are compatible with parametrically induced noise squeezing. Notably, the noise spectrum provides information on the spin dynamics even in regimes where the macroscopic atomic coherence is lost, effectively enhancing the sensitivity of the measurements. Our work promotes spin noise spectroscopy as a versatile technique for the study of noise squeezing in a wide range of spin based magnetic sensors.
△ Less
Submitted 23 December, 2020;
originally announced December 2020.
-
Dual frequency caesium spin maser
Authors:
Patrick Bevington,
Rafal Gartman,
Yevgeny V. Stadnik,
Witold Chalupczak
Abstract:
Co-magnetometers have been validated as valuable components of the atomic physics toolbox in fundamental and applied physics. So far, the explorations have been focused on systems involving nuclear spins. Presented here is a demonstration of an active alkali-metal (electronic) system, i.e. a dual frequency spin maser operating with the collective caesium F=3 and F=4 spins. The experiments have bee…
▽ More
Co-magnetometers have been validated as valuable components of the atomic physics toolbox in fundamental and applied physics. So far, the explorations have been focused on systems involving nuclear spins. Presented here is a demonstration of an active alkali-metal (electronic) system, i.e. a dual frequency spin maser operating with the collective caesium F=3 and F=4 spins. The experiments have been conducted in both magnetically shielded and unshielded environments. In addition to the discussion of the system's positive feedback mechanism, the implementation of the dual frequency spin maser for industrial non-destructive testing is shown. The stability of the F=3 and F=4 spin precession frequency ratio measurement is limited at the $3 \times 10^{-8}$ level, by the laser frequency drift, corresponding to a frequency stability of 1.2 mHz for $10^4$ sec integration time. We discuss measurement strategies that could improve this stability to nHz, enabling measurements with sensitivities to the axion-nucleon and axion-electron interactions at the levels of $f_a/C_N \sim 10^9$ GeV and $f_a/C_e \sim 10^8$ GeV, respectively.
△ Less
Submitted 20 January, 2020; v1 submitted 26 November, 2019;
originally announced November 2019.
-
Generation of atomic spin orientation with a linearly polarised beam in room-temperature alkali-metal vapour
Authors:
Patrick Bevington,
Rafal Gartman,
Witold Chalupczak
Abstract:
Traditionally, atomic spin orientation is achieved by the transfer of angular momentum from polarised light to an atomic system. We demonstrate the mechanism of orientation generation in room-temperature caesium vapours that combines three elements: optical pum**, non-linear spin dynamics and spin-exchange collisions. Through the variation of the spin-exchange relaxation rate, the transition bet…
▽ More
Traditionally, atomic spin orientation is achieved by the transfer of angular momentum from polarised light to an atomic system. We demonstrate the mechanism of orientation generation in room-temperature caesium vapours that combines three elements: optical pum**, non-linear spin dynamics and spin-exchange collisions. Through the variation of the spin-exchange relaxation rate, the transition between an aligned and an oriented atomic sample is presented. The observation is performed by monitoring the atomic radio-frequency spectra. The measurement configuration discussed, paves the way to simple and robust radio-frequency atomic magnetometers that are based on a single low power laser diode that approach the performance of multi-laser pump-probe systems.
△ Less
Submitted 20 January, 2020; v1 submitted 14 October, 2019;
originally announced October 2019.
-
Linear and non-linear coherent coupling in a Bell-Bloom magnetometer
Authors:
R. Gartman,
V. Guarrera,
G. Bevilacqua,
W. Chalupczak
Abstract:
Spin-exchange collisions in hot vapours are generally regarded as a decoherence mechanism. In contrast, we show that linear and non-linear spin-exchange coupling can lead to the generation of atomic coherence in a Bell-Bloom magnetometer. In particular, we theoretically and experimentally demonstrate that non-linear spin exchange coupling, acting in an analogous way to a wave-mixing mechanism, can…
▽ More
Spin-exchange collisions in hot vapours are generally regarded as a decoherence mechanism. In contrast, we show that linear and non-linear spin-exchange coupling can lead to the generation of atomic coherence in a Bell-Bloom magnetometer. In particular, we theoretically and experimentally demonstrate that non-linear spin exchange coupling, acting in an analogous way to a wave-mixing mechanism, can create new modes of coherent excitation which inherit the magnetic properties of the natural Larmor coherence. The generated coherences further couple via linear spin-exchange interaction, leading to an increase of the natural coherence lifetime of the system. Notably, the measurements are performed in a low-density caesium vapour and for non-zero magnetic field, outside the standard conditions for collisional coherence transfer. The strategies discussed are important for the development of spin-exchange coupling into a resource for an improved measurement platform based on room-temperature alkali-metal vapours.
△ Less
Submitted 13 March, 2019;
originally announced March 2019.
-
Parametric amplification and noise-squeezing in room temperature atomic vapours
Authors:
V. Guarrera,
R. Gartman,
G. Bevilacqua,
G. Barontini,
W. Chalupczak
Abstract:
We report on the use of parametric excitation to coherently manipulate the collective spin state of an atomic vapour at room temperature. Signatures of the parametric excitation are detected in the ground-state spin evolution. These include the excitation spectrum of the atomic coherences, which contains resonances at frequencies characteristic of the parametric process. The amplitudes of the sign…
▽ More
We report on the use of parametric excitation to coherently manipulate the collective spin state of an atomic vapour at room temperature. Signatures of the parametric excitation are detected in the ground-state spin evolution. These include the excitation spectrum of the atomic coherences, which contains resonances at frequencies characteristic of the parametric process. The amplitudes of the signal quadratures show amplification and attenuation, and their noise distribution is characterized by a strong asymmetry, similarly to those observed in mechanical oscillators. The parametric excitation is produced by periodic modulation of the pum** beam, exploiting a Bell-Bloom-like technique widely used in atomic magnetometry. Notably, we find that the noise-squeezing obtained by this technique enhances the signal-to-noise ratio of the measurements up to a factor of 10, and improves the performance of a Bell-Bloom magnetometer by a factor of 3.
△ Less
Submitted 1 March, 2019;
originally announced March 2019.
-
Enhanced material defects imaging with a radio-frequency atomic magnetometer
Authors:
P. Bevington,
R. Gartman,
W. Chalupczak
Abstract:
Imaging of structural defects in a material can be realized with a radio-frequency atomic magnetometer by monitoring the material's response to a radio-frequency excitation field. We demonstrate two measurement configurations that enable the increase of the amplitude and phase contrast in images that represent a structural defect in highly electrically conductive and high magnetic permeability sam…
▽ More
Imaging of structural defects in a material can be realized with a radio-frequency atomic magnetometer by monitoring the material's response to a radio-frequency excitation field. We demonstrate two measurement configurations that enable the increase of the amplitude and phase contrast in images that represent a structural defect in highly electrically conductive and high magnetic permeability samples. Both concepts involve the elimination of the excitation field component, orthogonal to the sample surface, from the atomic magnetometer signal. The first method relies on the implementation of a set of coils that directly compensates the excitation field component in the magnetometer signal. The second takes advantage of the fact that the radio-frequency magnetometer is not sensitive to the magnetic field oscillating along one of its axes. Results from simple modelling confirm the experimental observation and are discussed in detail.
△ Less
Submitted 27 November, 2018;
originally announced November 2018.
-
Imaging of material defects with a radio-frequency atomic magnetometer
Authors:
P. Bevington,
R. Gartman,
W. Chalupczak
Abstract:
Non-destructive eddy current testing of defects in metal plates using the magnetic resonance signal of a radio-frequency atomic magnetometer is demonstrated. The shape and amplitude of the spatial profile of signal features that correspond to defects are explored. By comparing numerical and experimental results on a series of benchmark aluminium plates we demonstrate a robust process for determini…
▽ More
Non-destructive eddy current testing of defects in metal plates using the magnetic resonance signal of a radio-frequency atomic magnetometer is demonstrated. The shape and amplitude of the spatial profile of signal features that correspond to defects are explored. By comparing numerical and experimental results on a series of benchmark aluminium plates we demonstrate a robust process for determining defect dimensions. In particular, we show that the observed images represent the spatial distribution of the secondary field created by eddy currents in the sample. We also demonstrate that the amplitude and phase contrast of the observed profiles enables us to reliably measure defect depth.
△ Less
Submitted 16 October, 2018;
originally announced November 2018.
-
Non-destructive structural imaging of steelwork with atomic magnetometers
Authors:
Patrick Bevington,
Rafal Gartman,
Witold Chalupczak,
Cameron Deans,
Luca Marmugi,
Ferruccio Renzoni
Abstract:
We demonstrate the imaging of ferromagnetic carbon steel samples and we detect the thinning of their profile with a sensitivity of 0.1 mm using a Cs radio-frequency atomic magnetometer. Images are obtained at room temperature, in magnetically unscreened environments. By using a dedicated arrangement of the setup and active compensation of background fields, the magnetic disturbance created by the…
▽ More
We demonstrate the imaging of ferromagnetic carbon steel samples and we detect the thinning of their profile with a sensitivity of 0.1 mm using a Cs radio-frequency atomic magnetometer. Images are obtained at room temperature, in magnetically unscreened environments. By using a dedicated arrangement of the setup and active compensation of background fields, the magnetic disturbance created by the samples' magnetization is compensated. Proof-of-concept demonstrations of non-destructive structural evaluation in the presence of concealing conductive barriers are also provided. The relevant impact for steelwork inspection and health and usage monitoring without disruption of operation is envisaged, with direct benefit for industry, from welding in construction to pipeline inspection and corrosion under insulation in the energy sector.
△ Less
Submitted 9 August, 2018;
originally announced August 2018.
-
Cancellation of the collisional frequency shift in caesium fountain clocks
Authors:
K. Szymaniec,
W. Chalupczak,
E. Tiesinga,
C. J. Williams,
S. Weyers,
R. Wynands
Abstract:
We have observed that the collisional frequency shift in primary caesium fountain clocks varies with the clock state population composition and, in particular, is zero for a given fraction of the |F = 4, mF = 0> atoms, depending on the initial cloud parameters. We present a theoretical model explaining our observations. The possibility of the collisional shift cancellation implies an improvement…
▽ More
We have observed that the collisional frequency shift in primary caesium fountain clocks varies with the clock state population composition and, in particular, is zero for a given fraction of the |F = 4, mF = 0> atoms, depending on the initial cloud parameters. We present a theoretical model explaining our observations. The possibility of the collisional shift cancellation implies an improvement in the performance of caesium fountain standards and a simplification in their operation. Our results also have implications for test operation of fountains at multiple pi/2 pulse areas.
△ Less
Submitted 12 December, 2006;
originally announced December 2006.