-
Drift Observations and Mitigation in LCLS-II RF
Authors:
L. Doolittle,
S. D. Murthy,
A. Benwell,
D. Chabot,
J. Chen,
B. Hong,
S. Hoobler,
J. Nelson,
C. Xu
Abstract:
The LCLS-II RF system physically spans ~700m and has strict requirements -- on the order of 20 fs -- on the phase stability of the accelerating RF fields in its SRF linac. While each LLRF rack is crudely temperature-stabilized, the weather inside the service building as a whole is usually compared to a tin shack in the California sun. A phase-averaging reference line is the primary system deployed…
▽ More
The LCLS-II RF system physically spans ~700m and has strict requirements -- on the order of 20 fs -- on the phase stability of the accelerating RF fields in its SRF linac. While each LLRF rack is crudely temperature-stabilized, the weather inside the service building as a whole is usually compared to a tin shack in the California sun. A phase-averaging reference line is the primary system deployed in support of the phase stability goals. There are other, secondary subsystems (SEL phase offset, and determination of cavity detuning) that are also sensitive to RF phase drift. We present measurements of phase shifts observed in the overall RF system, and how diagnostics are able to sense and correct for them during beam operations.
△ Less
Submitted 14 November, 2023; v1 submitted 25 October, 2023;
originally announced October 2023.
-
The LCLS-II Gun & Buncher LLRF Controller Upgrade
Authors:
Christos Bakalis,
Andrew Benwell,
Daron Chabot,
Lawrence Doolittle,
John Dusatko,
Daniele Filippetto,
Gang Huang,
Sergio Paiagua,
Carlos Serrano
Abstract:
LCLS-II is currently in its commissioning phase at SLAC. It is an X-ray FEL driven by a CW superconducting LINAC. The beam injector plays a crucial role in the overall performance of the accelerator, and is critical to the final electron beam performance parameters. The LCLS-II injector comprises of a 185.7 MHz VHF copper gun cavity, and a 1.3 GHz two-cell L-band copper buncher cavity. The FPGA-ba…
▽ More
LCLS-II is currently in its commissioning phase at SLAC. It is an X-ray FEL driven by a CW superconducting LINAC. The beam injector plays a crucial role in the overall performance of the accelerator, and is critical to the final electron beam performance parameters. The LCLS-II injector comprises of a 185.7 MHz VHF copper gun cavity, and a 1.3 GHz two-cell L-band copper buncher cavity. The FPGA-based controller employs feedback and Self-Excited Loop logic in order to regulate the cavity fields. It also features several other functionalities, such as live detune computation, active frequency tracking, and waveform recording. The LLRF system drives the cavities via two 60 kW SSAs through two power couplers, and thus stabilizes the fields inside the plant. This paper provides an outline of the general functionalities of the system, alongside a description of its hardware, firmware and software architecture, before finalizing with the current status of the project and its future goals.
△ Less
Submitted 8 November, 2022; v1 submitted 8 October, 2022;
originally announced October 2022.
-
Charged-particle branching ratios above the neutron threshold in $^{19}$F: constraining $^{15}$N production in core-collapse supernovae
Authors:
P. Adsley,
F. Hammache,
N. de Séréville,
V. Alcindor,
M. Assi é,
D. Beaumel M. Chabot,
M. Degerlier,
C. Delafosse,
T. Faestermann,
F. Flavigny,
S. P. Fox,
R. Garg,
A. Georgiadou,
S. A. Gillespie,
J. Guillot,
R. Hertenberger,
V. Guimarães,
R. Hertenberger,
A. Gottardo,
R. Hertenberger,
J. Kiener,
A. M. Laird,
A. Lefebvre-Schuhl,
I. Matea,
A. Meyer
, et al. (8 additional authors not shown)
Abstract:
Spatially-correlated overabundances of $^{15}$N and $^{18}$O observed in some low-density graphite meteoritic grains have been connected to nucleosynthesis taking place in the helium-burning shell during core-collapse supernovae. Two of the reactions which have been identified as important to the final abundances of $^{15}$N and $^{18}$O are $^{18}$F($n,α$)$^{15}$N and $^{18}$F($n,p$)$^{18}$O. The…
▽ More
Spatially-correlated overabundances of $^{15}$N and $^{18}$O observed in some low-density graphite meteoritic grains have been connected to nucleosynthesis taking place in the helium-burning shell during core-collapse supernovae. Two of the reactions which have been identified as important to the final abundances of $^{15}$N and $^{18}$O are $^{18}$F($n,α$)$^{15}$N and $^{18}$F($n,p$)$^{18}$O. The relative strengths of the $^{18}$F($n,α$)$^{15}$N and $^{18}$F($n,p$)$^{18}$O reactions depend on the relative $α_0$ and $p_0$ decays from states above the neutron threshold in $^{19}$F in addition to other properties. Experimental data on the charged-particle decays from these highly excited states are lacking or inconsistent. Two experiments were performed using proton inelastic scattering from LiF targets and magnetic spectrographs. The first experiment used the high-resolution Q3D spectrograph at Munich to constrain properties of levels in $^{19}$F. A second experiment using the Orsay Split-Pole spectrograph and an array of silicon detectors was performed in order to measure the charged-particle decays of neutron-unbound levels in $^{19}$F. A number of levels in $^{19}$F have been identified along with their corresponding charged-particle decays. The first state above the neutron threshold which has an observed proton-decay branch to the ground state of $^{18}$O lies 68 keV above the neutron threshold while the $α$-particle decays from the neutron-unbound levels are generally observed to be much stronger than the proton decays. Neutron-unbound levels in $^{19}$F are observed to decay predominantly by $α$-particle emission, supporting the role of $^{18}$F($n,α$)$^{15}$N in the production of $^{15}$N in the helium-burning shell of supernovae. Improved resonant-scattering reaction data are required in order to be able to determine the reaction rates accurately.
△ Less
Submitted 21 March, 2021; v1 submitted 8 July, 2020;
originally announced July 2020.
-
A student's guide to searching the literature using online databases
Authors:
Casey W. Miller,
Michelle D. Chabot,
Troy C. Messina
Abstract:
A method is described to empower students to efficiently perform general and literature searches using online resources. The method was tested on undergraduate and graduate students with varying backgrounds with scientific literature. Students involved in this study showed marked improvement in their awareness of how and where to find accurate scientific information.
A method is described to empower students to efficiently perform general and literature searches using online resources. The method was tested on undergraduate and graduate students with varying backgrounds with scientific literature. Students involved in this study showed marked improvement in their awareness of how and where to find accurate scientific information.
△ Less
Submitted 3 March, 2010;
originally announced March 2010.
-
Novel Fabrication of Micromechanical Oscillators with Nanoscale Sensitivity at Room Temperature
Authors:
Michelle D. Chabot,
John M. Moreland,
Lan Gao,
Sy-Hwang Liou,
Casey W. Miller
Abstract:
We report on the design, fabrication, and implementation of ultrasensitive micromechanical oscillators. Our ultrathin single-crystal silicon cantilevers with integrated magnetic structures are the first of their kind: They are fabricated using a novel high-yield process in which magnetic film patterning and deposition are combined with cantilever fabrication. These novel devices have been develo…
▽ More
We report on the design, fabrication, and implementation of ultrasensitive micromechanical oscillators. Our ultrathin single-crystal silicon cantilevers with integrated magnetic structures are the first of their kind: They are fabricated using a novel high-yield process in which magnetic film patterning and deposition are combined with cantilever fabrication. These novel devices have been developed for use as cantilever magnetometers and as force sensors in nuclear magnetic resonance force microscopy (MRFM). These two applications have achieved nanometer-scale resolution using the cantilevers described in this work. Current magnetic moment sensitivity achieved for the devices, when used as magnetometers, is 10^{-15} J/T at room temperature, which is more than a 1000 fold improvement in sensitivity, compared to conventional magnetometers. Current room temperature force sensitivity of MRFM cantilevers is ~10^{-16} N in a 1 Hz bandwidth, which is comparable to the room temperature sensitivities of similar devices of its type. Finite element modeling was used to improve design parameters, ensure that the devices meet experimental demands, and correlate mode shape with observed results. The photolithographic fabrication process was optimized, yielding an average of ~85% and alignment better than 1000 nm. Post-fabrication focused-ion-beam milling was used to further pattern the integrated magnetic structures when nanometer scale dimensions were required.
△ Less
Submitted 28 August, 2006;
originally announced August 2006.