Properties of HPK UFSD after neutron irradiation up to 6e15 n/cm2
Authors:
Z. Galloway,
V. Fadeyev,
P. Freeman,
E. Gkougkousis,
B. Gruey,
C. A. Labitan,
Z. Luce,
F. McKinney-Martinez,
H. F. -W. Sadrozinski,
A. Seiden,
E. Spencer,
M. Wilder,
N. Woods,
A. Zatserklyaniy,
Y. Zhao,
N. Cartiglia,
M. Ferrero,
S. Giordanengo,
M. Mandurrino,
A. Staiano,
V. Sola,
F. Cenna,
F. Fausti,
R. Arcidiacono,
F. Carnasecchi
, et al. (5 additional authors not shown)
Abstract:
In this paper we report results from a neutron irradiation campaign of Ultra-Fast Silicon Detectors (UFSD) with fluences of 1e14, 3e14, 6e14, 1e15, 3e15, 6e15 n/cm2. The UFSD used in this study are circular 50 micro-meter thick Low-Gain Avalanche Detectors (LGAD), with a 1.0 mm diameter active area. They have been produced by Hamamatsu Photonics (HPK), Japan, with pre-radiation internal gain in th…
▽ More
In this paper we report results from a neutron irradiation campaign of Ultra-Fast Silicon Detectors (UFSD) with fluences of 1e14, 3e14, 6e14, 1e15, 3e15, 6e15 n/cm2. The UFSD used in this study are circular 50 micro-meter thick Low-Gain Avalanche Detectors (LGAD), with a 1.0 mm diameter active area. They have been produced by Hamamatsu Photonics (HPK), Japan, with pre-radiation internal gain in the range 10-100 depending on the bias voltage. The sensors were tested pre-irradiation and post-irradiation with minimum ionizing particle (MIPs) from a 90Sr based \b{eta}-source. The leakage current, internal gain and the timing resolution were measured as a function of bias voltage at -20C and -30C. The timing resolution was extracted from the time difference with a second calibrated UFSD in coincidence, using the constant fraction method for both. The dependence of the gain upon the irradiation fluence is consistent with the concept of acceptor removal and the gain decreases from about 80 pre-irradiation to 7 after a fluence of 6e15 n/cm2. Consequently, the timing resolution was found to deteriorate from 20 ps to 50 ps. The results indicate that the most accurate time resolution is obtained at a value of the constant fraction discriminator (CFD) threshold used to determine the time of arrival varying with fluence, from 10% pre-radiation to 60% at the highest fluence. Key changes to the pulse shape induced by irradiation, i.e. (i) a reduce sensitivity of the pulse shape on the initial non-uniform charge deposition, (ii) the shortening of the rise time and (iii) the reduced pulse height, were compared with the WF2 simulation program and found to be in agreement.
△ Less
Submitted 10 April, 2020; v1 submitted 16 July, 2017;
originally announced July 2017.
Beam test results of a 16 ps timing system based on ultra-fast silicon detectors
Authors:
N. Cartiglia,
A. Staiano,
V. Sola,
R. Arcidiacono,
R. Cirio,
F. Cenna,
M. Ferrero,
V. Monaco,
R. Mulargia,
M. Obertino,
F. Ravera,
R. Sacchi,
A. Bellora,
S. Durando,
M. Mandurrino,
N. Minafra,
V. Fadeyev,
P. Freeman,
Z. Galloway,
E. Gkougkousis,
H. Grabas,
B. Gruey,
C. A. Labitan,
R. Losakul,
Z. Luce
, et al. (18 additional authors not shown)
Abstract:
In this paper we report on the timing resolution of the first production of 50 micro-meter thick Ultra-Fast Silicon Detectors (UFSD) as obtained in a beam test with pions of 180 GeV/c momentum. UFSD are based on the Low-Gain Avalanche Detectors (LGAD) design, employing n-on-p silicon sensors with internal charge multiplication due to the presence of a thin, low-resistivity diffusion layer below th…
▽ More
In this paper we report on the timing resolution of the first production of 50 micro-meter thick Ultra-Fast Silicon Detectors (UFSD) as obtained in a beam test with pions of 180 GeV/c momentum. UFSD are based on the Low-Gain Avalanche Detectors (LGAD) design, employing n-on-p silicon sensors with internal charge multiplication due to the presence of a thin, low-resistivity diffusion layer below the junction. The UFSD used in this test belongs to the first production of thin (50 μm) sensors, with an pad area of 1.4 mm2. The gain was measured to vary between 5 and 70 depending on the bias voltage. The experimental setup included three UFSD and a fast trigger consisting of a quartz bar readout by a SiPM. The timing resolution, determined comparing the time of arrival of the particle in one or more UFSD and the trigger counter, for single UFSD was measured to be 35 ps for a bias voltage of 200 V, and 26 ps for a bias voltage of 240 V, and for the combination of 3 UFSD to be 20 ps for a bias voltage of 200 V, and 15 ps for a bias voltage of 240 V.
△ Less
Submitted 3 January, 2017; v1 submitted 30 August, 2016;
originally announced August 2016.