Showing 1–2 of 2 results for author: Celinski, Z
-
Ferromagnetic Resonance of Co/Gd and Co/Tb Multilayers
Authors:
S. Demirtas,
I. Harward,
R. E. Camley,
Z. Celinski,
M. R. Hossu,
A. R. Koymen,
C. Yu,
M. J. Pechan
Abstract:
The in-plane dynamics of ferrimagnetic Co/Gd multilayers are investigated by means of ferromagnetic resonance, magneto-optical Kerr effect and SQUID magnetometry. The power absorbed from these multilayers is strongly temperature dependent. For example, the resonant peak for a (Co 40 A /Gd 40 A)8 multilayer vanishes approximately 50 K below room temperature. We have further investigated Gd/Co/Gd…
▽ More
The in-plane dynamics of ferrimagnetic Co/Gd multilayers are investigated by means of ferromagnetic resonance, magneto-optical Kerr effect and SQUID magnetometry. The power absorbed from these multilayers is strongly temperature dependent. For example, the resonant peak for a (Co 40 A /Gd 40 A)8 multilayer vanishes approximately 50 K below room temperature. We have further investigated Gd/Co/Gd and Tb/Co/Tb trilayers with different thicknesses of Gd (5-7 A), Tb (1-7 A) and Co (30-40 A). At room temperature, these Co-based trilayers show a shift of approximately 600 Oe at 24 GHz in the uniform ferromagnetic resonance field, compared to pure Co film, indicating the exchange coupling between the Co and Gd. The shift in the field for the resonance increases as the temperature is decreased. Furthermore the resonance linewidth increases as the temperature is decreased. The experimental results are in good agreement with our theoretical calculations.
△ Less
Submitted 25 February, 2010;
originally announced February 2010.
-
Small dimensional microstrips embedded with ferromagnetic layers: Numerical simulations and experimental results
Authors:
Jonah N. Gollub,
Bijoy Kuanr,
Zibigniew Celinski,
Robert Camley,
David R. Smith
Abstract:
We use a numerical electromagnetic simulation software to investigate a filtering device consisting of a small dimensional microstrips embedded with a thin layer of ferromagnetic material and we compare our results to experimental results. We are able to show good correlation of simulation versus experiment for the magnitude of insertion loss and phase shift. The microstrips considered have dime…
▽ More
We use a numerical electromagnetic simulation software to investigate a filtering device consisting of a small dimensional microstrips embedded with a thin layer of ferromagnetic material and we compare our results to experimental results. We are able to show good correlation of simulation versus experiment for the magnitude of insertion loss and phase shift. The microstrips considered have dimensions on the order of the skin depth of the conductor and hence the field distribution is not easily calculated by analytic methods. We show that numerical simulation methods provide an accurate means of characterizing these structures.
△ Less
Submitted 19 February, 2008;
originally announced February 2008.