-
Atom-Specific Probing of Electron Dynamics in an Atomic Adsorbate by Time-Resolved X-ray Spectroscopy
Authors:
Simon Schreck,
Elias Diesen,
Martina Dell'Angela,
Chang Liu,
Matthew Weston,
Flavio Capotondi,
Hirohito Ogasawara,
Jerry LaRue,
Roberto Costantini,
Martin Beye,
Piter S. Miedema,
Joakim Halldin Stenlid,
Jörgen Gladh,
Boyang Liu,
Hsin-Yi Wang,
Fivos Perakis,
Filippo Cavalca,
Sergey Koroidov,
Peter Amann,
Emanuele Pedersoli,
Denys Naumenko,
Ivaylo Nikolov,
Lorenzo Raimondi,
Frank Abild-Pedersen,
Tony F. Heinz
, et al. (3 additional authors not shown)
Abstract:
The electronic excitation occurring on adsorbates at ultrafast time scales from optical lasers that initiate surface chemical reactions is still an open question. Here, we report the ultrafast temporal evolution of X-ray absorption spectroscopy (XAS) and X-ray emission spectroscopy (XES) of a simple well known adsorbate prototype system, namely carbon (C) atoms adsorbed on a nickel (Ni(100)) surfa…
▽ More
The electronic excitation occurring on adsorbates at ultrafast time scales from optical lasers that initiate surface chemical reactions is still an open question. Here, we report the ultrafast temporal evolution of X-ray absorption spectroscopy (XAS) and X-ray emission spectroscopy (XES) of a simple well known adsorbate prototype system, namely carbon (C) atoms adsorbed on a nickel (Ni(100)) surface, following intense laser optical pum** at 400 nm. We observe ultrafast (~100 fs) changes in both XAS and XES showing clear signatures of the formation of a hot electron-hole pair distribution on the adsorbate. This is followed by slower changes on a few ps time scale, shown to be consistent with thermalization of the complete C/Ni system. Density functional theory spectrum simulations support this interpretation.
△ Less
Submitted 1 November, 2022;
originally announced November 2022.
-
Ultrafast adsorbate excitation probed with sub-ps resolution XAS
Authors:
Elias Diesen,
Hsin-Yi Wang,
Simon Schreck,
Matthew Weston,
Hirohito Ogasawara,
Jerry LaRue,
Fivos Perakis,
Martina Dell'Angela,
Flavio Capotondi,
Luca Giannessi,
Emanuele Pedersoli,
Denys Naumenko,
Ivaylo Nikolov,
Lorenzo Raimondi,
Carlo Spezzani,
Martin Beye,
Filippo Cavalca,
Boyang Liu,
Jörgen Gladh,
Sergey Koroidov,
Piter S. Miedema,
Roberto Costantini,
Tony F. Heinz,
Frank Abild-Pedersen,
Johannes Voss
, et al. (2 additional authors not shown)
Abstract:
We use a pump-probe scheme to measure the time evolution of the C K-edge X-ray absorption spectrum (XAS) from CO/Ru(0001) after excitation by an ultrashort high-intensity optical laser pulse. Due to the short duration of the X-ray probe pulse and precise control of the pulse delay, the excitation-induced dynamics during the first ps after the pump can be resolved with unprecedented time resolution…
▽ More
We use a pump-probe scheme to measure the time evolution of the C K-edge X-ray absorption spectrum (XAS) from CO/Ru(0001) after excitation by an ultrashort high-intensity optical laser pulse. Due to the short duration of the X-ray probe pulse and precise control of the pulse delay, the excitation-induced dynamics during the first ps after the pump can be resolved with unprecedented time resolution. By comparing with theoretical (DFT) spectrum calculations we find high excitation of the internal stretch and frustrated rotation modes occurring within 200 fs of laser excitation, as well as thermalization of the system in the ps regime. The ~100 fs initial excitation of these CO vibrational modes is not readily rationalized by traditional theories of nonadiabatic coupling of adsorbates to metal surfaces, e. g. electronic frictions based on first order electron-phonon coupling or transient population of adsorbate resonances. We suggest that coupling of the adsorbate to non-thermalized electron-hole pairs is responsible for the ultrafast initial excitation of the modes.
△ Less
Submitted 7 June, 2021;
originally announced June 2021.
-
POLARIX: a small mission of x-ray polarimetry
Authors:
Enrico Costa,
Ronaldo Bellazzini,
Paolo Soffitta,
Fabio Muleri,
Marco Feroci,
Massimo Frutti,
Marcello Mastropietro,
Luigi Pacciani,
Alda Rubini,
Ennio Morelli,
Luca Baldini,
Francesco Bitti,
Alessandro Brez,
Francesco Cavalca,
Luca Latronico,
Marco Maria Massai,
Nicola Omodei,
Michele Pinchera,
Carmelo Sgro',
Gloria Spandre,
Giorgio Matt,
Giuseppe Cesare Perola,
Guido Chincarini,
Oberto Citterio,
Gianpiero Tagliaferri
, et al. (2 additional authors not shown)
Abstract:
X-Ray Polarimetry can be now performed by using a Micro Pattern Gas Chamber in the focus of a telescope. It requires large area optics for most important scientific targets. But since the technique is additive a dedicated mission with a cluster of small telescopes can perform many important measurements and bridge the 40 year gap between OSO-8 data and future big telescopes such as XEUS. POLARIX…
▽ More
X-Ray Polarimetry can be now performed by using a Micro Pattern Gas Chamber in the focus of a telescope. It requires large area optics for most important scientific targets. But since the technique is additive a dedicated mission with a cluster of small telescopes can perform many important measurements and bridge the 40 year gap between OSO-8 data and future big telescopes such as XEUS. POLARIX has been conceived as such a pathfinder. It is a Small Satellite based on the optics of JET-X. Two telescopes are available in flight configuration and three more can be easily produced starting from the available superpolished mandrels. We show the capabilities of such a cluster of telescopes each equipped with a focal plane photoelectric polarimeter and discuss a few alternative solutions.
△ Less
Submitted 20 September, 2006;
originally announced September 2006.
-
An X-ray polarimeter for hard X-ray optics
Authors:
Fabio Muleri,
Ronaldo Bellazzini,
Enrico Costa,
Paolo Soffitta,
Francesco Lazzarotto,
Marco Feroci,
Luigi Pacciani,
Alda Rubini,
Ennio Morelli,
Luca Baldini,
Francesco Bitti,
Alessandro Brez,
Francesco Cavalca,
Luca Latronico,
Marco Maria Massai,
Nicola Omodei,
Michele Pinchera,
Carmelo Sgro',
Gloria Spandre,
Giorgio Matt,
Giuseppe Cesare Perola,
Oberto Citterio,
Giovanni Pareschi,
Vincenzo Cotroneo,
Daniele Spiga
, et al. (1 additional authors not shown)
Abstract:
Development of multi-layer optics makes feasible the use of X-ray telescope at energy up to 60-80 keV: in this paper we discuss the extension of photoelectric polarimeter based on Micro Pattern Gas Chamber to high energy X-rays. We calculated the sensitivity with Neon and Argon based mixtures at high pressure with thick absorption gap: placing the MPGC at focus of a next generation multi-layer o…
▽ More
Development of multi-layer optics makes feasible the use of X-ray telescope at energy up to 60-80 keV: in this paper we discuss the extension of photoelectric polarimeter based on Micro Pattern Gas Chamber to high energy X-rays. We calculated the sensitivity with Neon and Argon based mixtures at high pressure with thick absorption gap: placing the MPGC at focus of a next generation multi-layer optics, galatic and extragalactic X-ray polarimetry can be done up till 30 keV.
△ Less
Submitted 20 September, 2006;
originally announced September 2006.
-
A photoelectric polarimeter for XEUS: a new window in x-ray sky
Authors:
Ronaldo Bellazzini,
Luca Baldini,
Francesco Bitti,
Alessandro Brez,
Francesco Cavalca,
Luca Latronico,
Marco Maria Massai,
Nicola Omodei,
Michele Pinchera,
Carmelo Sgro',
Gloria Spandre,
Enrico Costa,
Paolo Soffitta,
Giuseppe Di Persio,
Marco Feroci,
Fabio Muleri,
Luigi Pacciani,
Alda Rubini,
Ennio Morelli,
Giorgio Matt,
Giuseppe Cesare Perola
Abstract:
XEUS is a large area telescope aiming to rise X-ray Astronomy to the level of Optical Astronomy in terms of collecting areas. It will be based on two satellites, locked on a formation flight, one with the optics, one with the focal plane. The present design of the focal plane foresees, as an auxiliary instrument, the inclusion of a Polarimeter based on a Micropattern Chamber. We show how such a…
▽ More
XEUS is a large area telescope aiming to rise X-ray Astronomy to the level of Optical Astronomy in terms of collecting areas. It will be based on two satellites, locked on a formation flight, one with the optics, one with the focal plane. The present design of the focal plane foresees, as an auxiliary instrument, the inclusion of a Polarimeter based on a Micropattern Chamber. We show how such a device is capable to solve open problems on many classes of High Energy Astrophysics objects and to use X-ray sources as a laboratory for a substantial progress on Fundamental Physics.
△ Less
Submitted 20 September, 2006;
originally announced September 2006.
-
Direct reading of charge multipliers with a self-triggering CMOS analog chip with 105k pixels at 50 micron pitch
Authors:
R. Bellazzini,
G. Spandre,
M. Minuti,
L. Baldini,
A. Brez,
F. Cavalca,
L. Latronico,
N. Omodei,
M. M. Massai,
C. Sgro,
E. Costa,
P. Soffitta F. Krummenacher,
R. DeOliveira
Abstract:
We report on a large active area (15x15mm2), high channel density (470 pixels/mm2), self-triggering CMOS analog chip that we have developed as pixelized charge collecting electrode of a Micropattern Gas Detector. This device, which represents a big step forward both in terms of size and performance, is the last version of three generations of custom ASICs of increasing complexity. The CMOS pixel…
▽ More
We report on a large active area (15x15mm2), high channel density (470 pixels/mm2), self-triggering CMOS analog chip that we have developed as pixelized charge collecting electrode of a Micropattern Gas Detector. This device, which represents a big step forward both in terms of size and performance, is the last version of three generations of custom ASICs of increasing complexity. The CMOS pixel array has the top metal layer patterned in a matrix of 105600 hexagonal pixels at 50 micron pitch. Each pixel is directly connected to the underneath full electronics chain which has been realized in the remaining five metal and two poly-silicon layers of a 0.18 micron VLSI technology. The chip has customizable self-triggering capability and includes a signal pre-processing function for the automatic localization of the event coordinates. In this way it is possible to reduce significantly the readout time and the data volume by limiting the signal output only to those pixels belonging to the region of interest. The very small pixel area and the use of a deep sub-micron CMOS technology has brought the noise down to 50 electrons ENC. Results from in depth tests of this device when coupled to a fine pitch (50 micron on a triangular pattern) Gas Electron Multiplier are presented. The matching of readout and gas amplification pitch allows to get optimal results. The application of this detector for Astronomical X-Ray Polarimetry is discussed. The experimental detector response to polarized and unpolarized X-ray radiation when working with two gas mixtures and two different photon energies is shown. Results from a full MonteCarlo simulation for several galactic and extragalactic atronomical sources are also reported.
△ Less
Submitted 26 April, 2006; v1 submitted 14 April, 2006;
originally announced April 2006.
-
Opening a New Window to Fundamental Physics and Astrophysics: X-ray Polarimetry
Authors:
E. Costa,
R. Bellazzini,
P. Soffitta,
G. di Persio,
M. Feroci,
E. Morelli,
F. Muleri,
L. Pacciani,
A. Rubini,
L. Baldini,
F. Bitti,
A. Brez,
F. Cavalca,
L. Latronico,
M. M. Massai,
N. Omodei,
C. Sgro',
G. Spandre,
G. Matt,
G. C. Perola,
A. Santangelo,
A. Celotti,
D. Barret,
O. Vilhu,
L. Piro
, et al. (3 additional authors not shown)
Abstract:
An extensive theoretical literature predicts that X-ray Polarimetry can directly determine relevant physical and geometrical parameters of astrophysical sources, and discriminate between models further than allowed by spectral and timing data only. X-ray Polarimetry can also provide tests of Fundamental Physics. A high sensitivity polarimeter in the focal plane of a New Generation X-ray telescop…
▽ More
An extensive theoretical literature predicts that X-ray Polarimetry can directly determine relevant physical and geometrical parameters of astrophysical sources, and discriminate between models further than allowed by spectral and timing data only. X-ray Polarimetry can also provide tests of Fundamental Physics. A high sensitivity polarimeter in the focal plane of a New Generation X-ray telescope could open this new window in the High Energy Sky.
△ Less
Submitted 15 March, 2006;
originally announced March 2006.
-
Gas Pixel Detectors for X-ray Polarimetry applications
Authors:
R. Bellazzini,
F. Angelini,
L. Baldini,
F. Bitti,
A. Brez,
F. Cavalca,
M. Del Prete,
M. Kuss,
L. Latronico,
N. Omodei,
M. Pinchera,
M. M. Massai,
M. Minuti,
M. Razzano,
C. Sgro,
G. Spandre,
A. Tenze,
E. Costa,
P. Soffitta
Abstract:
We discuss a new class of Micro Pattern Gas Detectors, the Gas Pixel Detector (GPD), in which a complete integration between the gas amplification structure and the read-out electronics has been reached. An Application-Specific Integrated Circuit (ASIC) built in deep sub-micron technology has been developed to realize a monolithic device that is, at the same time, the pixelized charge collecting…
▽ More
We discuss a new class of Micro Pattern Gas Detectors, the Gas Pixel Detector (GPD), in which a complete integration between the gas amplification structure and the read-out electronics has been reached. An Application-Specific Integrated Circuit (ASIC) built in deep sub-micron technology has been developed to realize a monolithic device that is, at the same time, the pixelized charge collecting electrode and the amplifying, sha** and charge measuring front-end electronics. The CMOS chip has the top metal layer patterned in a matrix of 80 micron pitch hexagonal pixels, each of them directly connected to the underneath electronics chain which has been realized in the remaining five layers of the 0.35 micron VLSI technology. Results from tests of a first prototype of such detector with 2k pixels and a full scale version with 22k pixels are presented. The application of this device for Astronomical X-Ray Polarimetry is discussed. The experimental detector response to polarized and unpolarized X-ray radiation is shown. Results from a full MonteCarlo simulation for two astronomical sources, the Crab Nebula and the Hercules X1, are also reported.
△ Less
Submitted 8 February, 2006; v1 submitted 9 December, 2005;
originally announced December 2005.