-
Measured and projected beam backgrounds in the Belle II experiment at the SuperKEKB collider
Authors:
A. Natochii,
T. E. Browder,
L. Cao,
G. Cautero,
S. Dreyer,
A. Frey,
A. Gabrielli,
D. Giuressi,
T. Ishibashi,
Y. **,
K. Kojima,
T. Kraetzschmar,
L. Lanceri,
Z. Liptak,
D. Liventsev,
C. Marinas,
L. Massaccesi,
K. Matsuoka,
F. Meier,
C. Miller,
H. Nakayama,
C. Niebuhr,
A. Novosel,
K. Parham,
I. Popov
, et al. (21 additional authors not shown)
Abstract:
The Belle II experiment at the SuperKEKB electron-positron collider aims to collect an unprecedented data set of $50~{\rm ab}^{-1}$ to study $CP$-violation in the $B$-meson system and to search for Physics beyond the Standard Model. SuperKEKB is already the world's highest-luminosity collider. In order to collect the planned data set within approximately one decade, the target is to reach a peak l…
▽ More
The Belle II experiment at the SuperKEKB electron-positron collider aims to collect an unprecedented data set of $50~{\rm ab}^{-1}$ to study $CP$-violation in the $B$-meson system and to search for Physics beyond the Standard Model. SuperKEKB is already the world's highest-luminosity collider. In order to collect the planned data set within approximately one decade, the target is to reach a peak luminosity of $\rm 6 \times 10^{35}~cm^{-2}s^{-1}$ by further increasing the beam currents and reducing the beam size at the interaction point by squeezing the betatron function down to $β^{*}_{\rm y}=\rm 0.3~mm$. To ensure detector longevity and maintain good reconstruction performance, beam backgrounds must remain well controlled. We report on current background rates in Belle II and compare these against simulation. We find that a number of recent refinements have significantly improved the background simulation accuracy. Finally, we estimate the safety margins going forward. We predict that backgrounds should remain high but acceptable until a luminosity of at least $\rm 2.8 \times 10^{35}~cm^{-2}s^{-1}$ is reached for $β^{*}_{\rm y}=\rm 0.6~mm$. At this point, the most vulnerable Belle II detectors, the Time-of-Propagation (TOP) particle identification system and the Central Drift Chamber (CDC), have predicted background hit rates from single-beam and luminosity backgrounds that add up to approximately half of the maximum acceptable rates.
△ Less
Submitted 11 December, 2023; v1 submitted 3 February, 2023;
originally announced February 2023.
-
Characterization of the transient response of diamond sensors to collimated, sub-ps, 1 GeV electron bunches
Authors:
Silvano Bassanese,
Luciano Bosisio,
Giuseppe Cautero,
Simone Di Mitri,
Mario Ferianis,
Alice Gabrielli,
Dario Giuressi,
Yifan **,
Livio Lanceri,
Marco Marich,
Ralf Hendrik Menk,
Lorenzo Vitale
Abstract:
Diamond sensors (DS) are widely used as solid-state particle detectors, beam loss monitors, and dosimeters in high-radiation environments, e.g., particle colliders. We have calibrated our DS with steady $β$- and X-radiation, spanning a dose rate in the range 0.1-100 mGy/s. Here, we report the first systematic characterization of transient responses of DS to collimated, sub-picosecond, 1 GeV electr…
▽ More
Diamond sensors (DS) are widely used as solid-state particle detectors, beam loss monitors, and dosimeters in high-radiation environments, e.g., particle colliders. We have calibrated our DS with steady $β$- and X-radiation, spanning a dose rate in the range 0.1-100 mGy/s. Here, we report the first systematic characterization of transient responses of DS to collimated, sub-picosecond, 1 GeV electron bunches. These bunches, possessing a charge ranging from tens to hundreds of pC and a size from tens of microns to millimeters, are suitably provided by the FERMI electron linac in Trieste, Italy. The high density of charge carriers generated by ionization in the diamond bulk causes a transient modification of electrical properties of DS (e.g., resistance), which in turn affects the signal shape. We have modeled a two-step numerical approach, simulating the effects on the signal of both the evolution of charge carrier density in the diamond bulk and the changes in the circuit parameters. This approach interprets features observed in our experimental results to a great extent.
△ Less
Submitted 24 October, 2022;
originally announced October 2022.
-
Measurements of Beam Backgrounds in SuperKEKB Phase 2
Authors:
Zachary J. Liptak,
Antonio Paladino,
Luka Santelj,
Jeffery Schueler,
Slavomira Stefkova,
Hikaru Tanigawa,
Noritsugu Tsuzuki,
Alberto Aloisio,
Patrick Ahlburg,
Philip Bambade,
Giovanni Bassi,
Matthew Barrett,
Jerome Baudot,
Thomas Browder,
Giulia Casarosa,
Giuseppe Cautero,
David Cinabro,
Gilles Claus,
Daniel Cuesta,
Francesco Di Capua,
Salvatore Di Carlo,
John Flanagan,
Ariane Frey,
Bryan Fulsom,
Yoshihiro Funakoshi
, et al. (44 additional authors not shown)
Abstract:
The high design luminosity of the SuperKEKB electron-positron collider will result in challenging levels of beam-induced backgro\ unds in the interaction region. Understanding and mitigating these backgrounds is critical to the success of the Belle~II experi\ ment. We report on the first background measurements performed after roll-in of the Belle II detector, a period known as SuperKE\ KB Phase 2…
▽ More
The high design luminosity of the SuperKEKB electron-positron collider will result in challenging levels of beam-induced backgro\ unds in the interaction region. Understanding and mitigating these backgrounds is critical to the success of the Belle~II experi\ ment. We report on the first background measurements performed after roll-in of the Belle II detector, a period known as SuperKE\ KB Phase 2, utilizing both the BEAST II system of dedicated background detectors and the Belle II detector itself. We also repor\ t on first revisions to the background simulation made in response to our findings. Backgrounds measured include contributions f\ rom synchrotron radiation, beam-gas, Touschek, and injection backgrounds. At the end of Phase 2, single-beam backgrounds origina\ ting from the 4 GeV positron Low Energy Ring (LER) agree reasonably well with simulation, while backgrounds from the 7 GeV elect\ ron High Energy Ring (HER) are approximately one order of magnitude higher than simulation. We extrapolate these backgrounds for\ ward and conclude it is safe to install the Belle II vertex detector.
△ Less
Submitted 29 December, 2021;
originally announced December 2021.
-
Performance of the diamond-based beam-loss monitor system of Belle II
Authors:
S. Bacher,
G. Bassi,
L. Bosisio,
G. Cautero,
P. Cristaudo,
M. Dorigo,
A. Gabrielli,
D. Giuressi,
K. Hara,
Y. **,
C. La Licata,
L. Lanceri,
R. Manfredi,
H. Nakayama,
K. R. Nakamura,
A. Natochii,
A. Paladino,
G. Rizzo,
L. Vitale,
H. Yin
Abstract:
We designed, constructed and have been operating a system based on single-crystal synthetic diamond sensors, to monitor the beam losses at the interaction region of the SuperKEKB asymmetric-energy electron-positron collider. The system records the radiation dose-rates in positions close to the inner detectors of the Belle II experiment, and protects both the detector and accelerator components aga…
▽ More
We designed, constructed and have been operating a system based on single-crystal synthetic diamond sensors, to monitor the beam losses at the interaction region of the SuperKEKB asymmetric-energy electron-positron collider. The system records the radiation dose-rates in positions close to the inner detectors of the Belle II experiment, and protects both the detector and accelerator components against destructive beam losses, by participating in the beam-abort system. It also provides complementary information for the dedicated studies of beam-related backgrounds. We describe the performance of the system during the commissioning of the accelerator and during the first physics data taking.
△ Less
Submitted 9 February, 2021;
originally announced February 2021.
-
Visible pump -- mid infrared pump -- broadband probe: development and characterization of a three-pulse setup for single-shot ultrafast spectroscopy at 50 kHz
Authors:
Angela Montanaro,
Francesca Giusti,
Matija Colja,
Gabriele Brajnik,
Alexandre M. A. Marciniak,
Rudi Sergo,
Dario De Angelis,
Filippo Glerean,
Giorgia Sparapassi,
Giacomo Jarc,
Sergio Carrato,
Giuseppe Cautero,
Daniele Fausti
Abstract:
We report here an experimental setup to perform three-pulse pump-probe measurements over a wide wavelength and temperature range. By combining two pump pulses in the visible (650-900 nm) and mid-IR (5-20 $μ$m) range, with a broadband supercontinuum white-light probe, our apparatus enables both the combined selective excitation of different material degrees of freedom and a full time-dependent reco…
▽ More
We report here an experimental setup to perform three-pulse pump-probe measurements over a wide wavelength and temperature range. By combining two pump pulses in the visible (650-900 nm) and mid-IR (5-20 $μ$m) range, with a broadband supercontinuum white-light probe, our apparatus enables both the combined selective excitation of different material degrees of freedom and a full time-dependent reconstruction of the non-equilibrium dielectric function of the sample. We describe here the optical setup, the cryogenic sample environment and the custom-made acquisition electronics capable of referenced single-pulse detection of broadband spectra at the maximum repetition rate of 50 kHz, achieving a sensitivity of the order of 10$^{-4}$ over an integration time of 1 s. We demonstrate the performance of the setup by reporting data on mid-IR pump, optical push and broadband probe in a single-crystal of Bi$_2$Sr$_2$Y$_{0.08}$Ca$_{0.92}$Cu$_2$O$_{8+δ}$ across the superconducting and pseudogap phases.
△ Less
Submitted 5 June, 2020;
originally announced June 2020.
-
The new FAST module: a portable and transparent add-on module for time-resolved investigations with commercial scanning probe microscopes
Authors:
Carlo Dri,
Mirco Panighel,
Daniel Tiemann,
Laerte L. Patera,
Giulia Troiano,
Yves Fukamori,
Fabian Knoller,
Barbara A. J. Lechner,
Giuseppe Cautero,
Dario Giuressi,
Giovanni Comelli,
Jordi Fraxedas,
Cristina Africh,
Friedrich Esch
Abstract:
Time resolution is one of the most severe limitations of scanning probe microscopies (SPMs), since the typical image acquisition times are in the order of several seconds or even few minutes. As a consequence, the characterization of dynamical processes occurring at surfaces (e.g. surface diffusion, film growth, self-assembly and chemical reactions) cannot be thoroughly addressed by conventional S…
▽ More
Time resolution is one of the most severe limitations of scanning probe microscopies (SPMs), since the typical image acquisition times are in the order of several seconds or even few minutes. As a consequence, the characterization of dynamical processes occurring at surfaces (e.g. surface diffusion, film growth, self-assembly and chemical reactions) cannot be thoroughly addressed by conventional SPMs. To overcome this limitation, several years ago we developed a first prototype of the FAST module, an add-on instrument capable of driving a commercial scanning tunneling microscope (STM) at and beyond video rate frequencies. Here we report on a fully redesigned version of the FAST module, featuring improved performance and user experience, which can be used both with STMs and atomic force microscopes (AFMs), and offers additional capabilities such as an atom tracking mode. All the new features of the FAST module, including portability between different commercial instruments, are described in detail and practically demonstrated.
△ Less
Submitted 21 June, 2019; v1 submitted 20 June, 2019;
originally announced June 2019.
-
First Measurements of Beam Backgrounds at SuperKEKB
Authors:
P. M. Lewis,
I. Jaegle,
H. Nakayama,
A. Aloisio,
F. Ameli,
M. Barrett,
A. Beaulieu,
L. Bosisio,
P. Branchini,
T. E. Browder,
A. Budano,
G. Cautero,
C. Cecchi,
Y. -T. Chen,
K. -N. Chu,
D. Cinabro,
P. Cristaudo,
S. de Jong,
R. de Sangro,
G. Finocchiaro,
J. Flanagan,
Y. Funakoshi,
M. Gabriel,
R. Giordano,
D. Giuressi
, et al. (45 additional authors not shown)
Abstract:
The high design luminosity of the SuperKEKB electron-positron collider is expected to result in challenging levels of beam-induced backgrounds in the interaction region. Properly simulating and mitigating these backgrounds is critical to the success of the Belle~II experiment. We report on measurements performed with a suite of dedicated beam background detectors, collectively known as BEAST II, d…
▽ More
The high design luminosity of the SuperKEKB electron-positron collider is expected to result in challenging levels of beam-induced backgrounds in the interaction region. Properly simulating and mitigating these backgrounds is critical to the success of the Belle~II experiment. We report on measurements performed with a suite of dedicated beam background detectors, collectively known as BEAST II, during the so-called Phase 1 commissioning run of SuperKEKB in 2016, which involved operation of both the high energy ring (HER) of 7 GeV electrons as well as the low energy ring (LER) of 4 GeV positrons. We describe the BEAST II detector systems, the simulation of beam backgrounds, and the measurements performed. The measurements include standard ones of dose rates versus accelerator conditions, and more novel investigations, such as bunch-by-bunch measurements of injection backgrounds and measurements sensitive to the energy spectrum and angular distribution of fast neutrons. We observe beam-gas, Touschek, beam-dust, and injection backgrounds. We do not observe significant synchrotron radiation, as expected. Measured LER beam-gas backgrounds and Touschek backgrounds in both rings are slightly elevated, on average three times larger than the levels predicted by simulation. HER beam-gas backgrounds are on on average two orders of magnitude larger than predicted. Systematic uncertainties and channel-to-channel variations are large, so that these excesses constitute only 1-2 sigma level effects. Neutron background rates are higher than predicted and should be studied further. We will measure the remaining beam background processes, due to colliding beams, in the imminent commissioning Phase 2. These backgrounds are expected to be the most critical for Belle II, to the point of necessitating replacement of detector components during the Phase 3 (full-luminosity) operation of SuperKEB.
△ Less
Submitted 5 February, 2018;
originally announced February 2018.
-
Development and tests of a new prototype detector for the XAFS beamline at Elettra Synchrotron in Trieste
Authors:
S Fabiani,
M Ahangarianabhari,
G Baldazzi,
P Bellutti,
G Bertuccio,
M Bruschi,
J Bufon,
S Carrato,
A Castoldi,
G Cautero,
S Ciano,
A Cicuttin,
M L Crespo,
M Dos Santos,
M Gandola,
G Giacomini,
D Giuressi,
C Guazzoni,
R H Menk,
J Niemela,
L Olivi,
A Picciotto,
C Piemonte,
I Rashevskaya,
A Rachevski
, et al. (8 additional authors not shown)
Abstract:
The XAFS beamline at Elettra Synchrotron in Trieste combines X-ray absorption spectroscopy and X-ray diffraction to provide chemically specific structural information of materials. It operates in the energy range 2.4-27 keV by using a silicon double reflection Bragg monochromator. The fluorescence measurement is performed in place of the absorption spectroscopy when the sample transparency is too…
▽ More
The XAFS beamline at Elettra Synchrotron in Trieste combines X-ray absorption spectroscopy and X-ray diffraction to provide chemically specific structural information of materials. It operates in the energy range 2.4-27 keV by using a silicon double reflection Bragg monochromator. The fluorescence measurement is performed in place of the absorption spectroscopy when the sample transparency is too low for transmission measurements or the element to study is too diluted in the sample. We report on the development and on the preliminary tests of a new prototype detector based on Silicon Drift Detectors technology and the SIRIO ultra low noise front-end ASIC. The new system will be able to reduce drastically the time needed to perform fluorescence measurements, while kee** a short dead time and maintaining an adequate energy resolution to perform spectroscopy. The custom-made silicon sensor and the electronics are designed specifically for the beamline requirements.
△ Less
Submitted 12 January, 2016;
originally announced January 2016.
-
A microspectroscopic study of the electronic homogeneity of ordered and disordered Sr2FeMoO6
Authors:
Dinesh Topwal,
U. Manju,
Sugata Ray,
S. Raj,
D. D. Sarma,
S. R. Krishnakumar,
M. Bertolo,
S. La Rosa,
G. Cautero
Abstract:
Besides a drastic reduction in saturation magnetization of disordered Sr2FeMoO6 compared to highly ordered samples, magnetizations as a function of the temperature for different disordered samples may also show qualitatively different behaviors. We investigate the origin of such diversity by performing spatially resolved photoemission spectroscopy on various disordered samples. Our results estab…
▽ More
Besides a drastic reduction in saturation magnetization of disordered Sr2FeMoO6 compared to highly ordered samples, magnetizations as a function of the temperature for different disordered samples may also show qualitatively different behaviors. We investigate the origin of such diversity by performing spatially resolved photoemission spectroscopy on various disordered samples. Our results establish that extensive electronic inhomogeneity, arising most probably from an underlying chemical inhomogeneity in disordered samples is responsible for the observed magnetic inhomogeneity. It is further pointed out that these inhomogeneities are connected with composition fluctuations of the type Sr2Fe1+xMo1-xO6 with Fe-rich (x>0) and Mo-rich (x<0) regions.
△ Less
Submitted 10 March, 2006;
originally announced March 2006.
-
Direct observation of electronic domains in manganites by spatially resolved spectroscopy
Authors:
D. D. Sarma,
Dinesh Topwal,
U. Manju,
S. R. Krishnakumar,
M. Bertolo,
S. La Rosa,
G. Cautero,
T. Y. Koo,
P. A. Sharma,
S-W. Cheong,
A. Fujimori
Abstract:
We use a spatially resolved, direct spectroscopic probe for electronic structure with an additional sensitivity to chemical compositions to investigate high-quality single crystal samples of La_{1/4}Pr_{3/8}Ca_{3/8}MnO_{3}, establishing the formation of distinct insulating domains embedded in the metallic host at low temperatures. These domains are found to be at least an order of magnitude larg…
▽ More
We use a spatially resolved, direct spectroscopic probe for electronic structure with an additional sensitivity to chemical compositions to investigate high-quality single crystal samples of La_{1/4}Pr_{3/8}Ca_{3/8}MnO_{3}, establishing the formation of distinct insulating domains embedded in the metallic host at low temperatures. These domains are found to be at least an order of magnitude larger in size compared to previous estimates and exhibit memory effects on temperature cycling in the absence of any perceptible chemical inhomogeneity, suggesting long-range strains as the probable origin.
△ Less
Submitted 14 September, 2004;
originally announced September 2004.