Time-efficient, High Resolution 3T Whole Brain Quantitative Relaxometry using 3D-QALAS with Wave-CAIPI Readouts
Authors:
Jae** Cho,
Borjan Gagoski,
Tae Hyung Kim,
Fuyixue Wang,
Daniel Nico Splitthoff,
Wei-Ching Lo,
Wei Liu,
Daniel Polak,
Stephen Cauley,
Kawin Setsompop,
P. Ellen Grant,
Berkin Bilgic
Abstract:
Purpose: Volumetric, high-resolution, quantitative map** of brain tissue relaxation properties is hindered by long acquisition times and signal-to-noise (SNR) challenges. This study, for the first time, combines the time-efficient wave-CAIPI readouts into the 3D-quantification using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (3D-QALAS) acquisition scheme, enablin…
▽ More
Purpose: Volumetric, high-resolution, quantitative map** of brain tissue relaxation properties is hindered by long acquisition times and signal-to-noise (SNR) challenges. This study, for the first time, combines the time-efficient wave-CAIPI readouts into the 3D-quantification using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (3D-QALAS) acquisition scheme, enabling full brain quantitative T1, T2 and proton density (PD) maps at 1.15 mm3 isotropic voxels in only 3 minutes. Methods: Wave-CAIPI readouts were embedded in the standard 3D-QALAS encoding scheme, enabling full brain quantitative parameter maps (T1, T2, and PD) at acceleration factors of R=3x2 with minimum SNR loss due to g-factor penalties. The quantitative parameter maps were estimated using a dictionary-based map** algorithm incorporating inversion efficiency and B1 field inhomogeneity. The quantitative maps using the accelerated protocol were quantitatively compared against those obtained from conventional 3D-QALAS sequence using GRAPPA acceleration of R=2 in the ISMRM NIST phantom, and ten healthy volunteers. Results: When tested in both the ISMRM/NIST phantom and ten healthy volunteers, the quantitative maps using the accelerated protocol showed excellent agreement against those obtained from conventional 3D-QALAS at RGRAPPA=2. Conclusion: 3D-QALAS enhanced with wave-CAIPI readouts enables time-efficient, full brain quantitative T1, T2, and PD map** at 1.15 mm3 in 3 minutes at R=3x2 acceleration. When tested on the NIST phantom and ten healthy volunteers, the quantitative maps obtained from the accelerated wave-CAIPI 3D-QALAS protocol showed very similar values to those obtained from the standard 3D-QALAS (R=2) protocol, alluding to the robustness and reliability of the proposed methods.
△ Less
Submitted 27 January, 2023; v1 submitted 8 November, 2022;
originally announced November 2022.
-
External Dynamic InTerference Estimation and Removal (EDITER) for low field MRI
Authors:
Sai Abitha Srinivas,
Stephen F Cauley,
Jason P Stockmann,
Charlotte R Sappo,
Christopher E Vaughn,
Lawrence L Wald,
William A Grissom,
Clarissa Z Cooley
Abstract:
Purpose: Point-of-care MRI requires operation outside of a faraday shielded room normally used to block image-degrading electromagnetic Interference (EMI). To address this, we introduce the EDITER method, an external sensor based dynamic EMI estimation and removal method to retrospectively remove time-varying external interference sources.
Theory and Methods: The method acquires data from multip…
▽ More
Purpose: Point-of-care MRI requires operation outside of a faraday shielded room normally used to block image-degrading electromagnetic Interference (EMI). To address this, we introduce the EDITER method, an external sensor based dynamic EMI estimation and removal method to retrospectively remove time-varying external interference sources.
Theory and Methods: The method acquires data from multiple EMI detectors (tuned receive coils and electrodes placed on the body) simultaneous with the primary MR coil during image data acquisition. We dynamically calculate impulse response functions that map the data from the detectors to the artifacts in the kspace data, then remove the transformed detected EMI from the MR data. Performance of the EDITER algorithm was assessed in phantom and in vivo imaging experiments in an 80mT portable brain MRI in a controlled EMI environment and with an open 47.5mT MRI scanner in an uncontrolled EMI setting.
Results: In the controlled setting, the effectiveness of the EDITER technique was demonstrated for specific types of introduced EMI sources with up to a 97% reduction of structured EMI and up to 76% reduction of broadband EMI. In the uncontrolled EMI experiments, we demonstrate EMI reductions of 37% with a single pickup coil and 89% with a single electrode and up to 99% with both.
Conclusion: The EDITER technique is a flexible and robust method to improve image quality in portable MRI systems with minimal passive shielding. This could reduce the reliance of MRI on shielded rooms and allow for truly portable MRI with specialized compact POC scanners
△ Less
Submitted 29 April, 2021; v1 submitted 17 April, 2021;
originally announced April 2021.
-
Wave-encoding and Shuffling Enables Rapid Time Resolved Structural Imaging
Authors:
Siddharth Iyer,
Daniel Polak,
Congyu Liao,
Jonathan I. Tamir,
Stephen F. Cauley,
Borjan Gagoski,
Wei-Ching Lo,
Berkin Bilgic,
Kawin Setsompop
Abstract:
T2-Shuffling reconstructs multiple sharp T2-weighted images from a single volumetric fast spin-echo (3D-FSE) scan. Wave-CAIPI is a parallel imaging technique that achieves good reconstruction at high accelerations through additional sinusoidal gradients that induce a voxel spreading effect in the readout direction to better take advantage of coil-sensitivity information. In this work, the Shufflin…
▽ More
T2-Shuffling reconstructs multiple sharp T2-weighted images from a single volumetric fast spin-echo (3D-FSE) scan. Wave-CAIPI is a parallel imaging technique that achieves good reconstruction at high accelerations through additional sinusoidal gradients that induce a voxel spreading effect in the readout direction to better take advantage of coil-sensitivity information. In this work, the Shuffling model in T2-Shuffling is augmented with wave-encoding to achieve higher acceleration capability. The resulting "Wave-Shuffling" approach is applied to 3D-FSE and Magnetization-Prepared Rapid Gradient-Echo (MPRAGE) to achieve rapid, 1 mm-isotropic resolution, time-resolved structural imaging.
△ Less
Submitted 31 May, 2022; v1 submitted 29 March, 2021;
originally announced March 2021.
-
A Portable Brain MRI Scanner for Underserved Settings and Point-Of-Care Imaging
Authors:
Clarissa Z. Cooley,
Patrick C. McDaniel,
Jason P. Stockmann,
Sai Abitha Srinivas,
Stephen Cauley,
Monika Sliwiak,
Charlotte R. Sappo,
Christopher F. Vaughn,
Bastien Guerin,
Matthew S. Rosen,
Michael H. Lev,
Lawrence L. Wald
Abstract:
Access to and availability of MRI scanners is typically limited by their cost, siting and infrastructure requirements. This precludes MRI diagnostics, the reference standard for neurological assessment, in patients who cannot be transported to specialized scanner suites. This includes patients who are critically ill and unstable, and patients located in low-resource settings. The scanner design pr…
▽ More
Access to and availability of MRI scanners is typically limited by their cost, siting and infrastructure requirements. This precludes MRI diagnostics, the reference standard for neurological assessment, in patients who cannot be transported to specialized scanner suites. This includes patients who are critically ill and unstable, and patients located in low-resource settings. The scanner design presented here aims to extend the reach of MRI by substantially reducing these limitations. Our goal is to shift the cost-benefit calculation for MRI toward more frequent and varied use, including improved accessibility worldwide and point of care operation. Here, we describe a portable brain MRI scanner using a compact, lightweight permanent magnet, with a built-in readout field gradient. Our low-field (80 mT) Halbach cylinder design of rare-earth permanent magnets results in a 122 kg magnet with minimal stray-field, requiring neither cryogenics nor external power. The built-in magnetic field gradient reduces reliance on high-power gradient drivers, which not only lowers overall system power and cooling requirements, but also reduces acoustic noise. Imperfections in the encoding fields are mitigated with a generalized iterative image reconstruction technique, that uses prior characterization of the field patterns. Our system was validated using T1, T2 and proton density weighted in vivo brain images with a spatial resolution of 2.2 x 1.3 x 6.8 mm$^3$.
△ Less
Submitted 27 April, 2020;
originally announced April 2020.
-
Joint multi-contrast Variational Network reconstruction (jVN) with application to rapid 2D and 3D imaging
Authors:
Daniel Polak,
Stephen Cauley,
Berkin Bilgic,
Enhao Gong,
Peter Bachert,
Elfar Adalsteinsson,
Kawin Setsompop
Abstract:
Purpose: To improve the image quality of highly accelerated multi-channel MRI data by learning a joint variational network that reconstructs multiple clinical contrasts jointly.
Methods: Data from our multi-contrast acquisition was embedded into the variational network architecture where shared anatomical information is exchanged by mixing the input contrasts. Complementary k-space sampling acro…
▽ More
Purpose: To improve the image quality of highly accelerated multi-channel MRI data by learning a joint variational network that reconstructs multiple clinical contrasts jointly.
Methods: Data from our multi-contrast acquisition was embedded into the variational network architecture where shared anatomical information is exchanged by mixing the input contrasts. Complementary k-space sampling across imaging contrasts and Bunch-Phase/Wave-Encoding were used for data acquisition to improve the reconstruction at high accelerations. At 3T, our joint variational network approach across T1w, T2w and T2-FLAIR-weighted brain scans was tested for retrospective under-sampling at R=6 (2D) and R=4x4 (3D) acceleration. Prospective acceleration was also performed for 3D data where the combined acquisition time for whole brain coverage at 1 mm isotropic resolution across three contrasts was less than three minutes.
Results: Across all test datasets, our joint multi-contrast network better preserved fine anatomical details with reduced image-blurring when compared to the corresponding single-contrast reconstructions. Improvement in image quality was also obtained through complementary k-space sampling and Bunch-Phase/Wave-Encoding where the synergistic combination yielded the overall best performance as evidenced by exemplarily slices and quantitative error metrics.
Conclusion: By leveraging shared anatomical structures across the jointly reconstructed scans, our joint multi-contrast approach learnt more efficient regularizers which helped to retain natural image appearance and avoid over-smoothing. When synergistically combined with advanced encoding techniques, the performance was further improved, enabling up to R=16-fold acceleration with good image quality. This should help pave the way to very rapid high-resolution brain exams.
△ Less
Submitted 8 October, 2019;
originally announced October 2019.
-
Highly Accelerated Multishot EPI through Synergistic Machine Learning and Joint Reconstruction
Authors:
Berkin Bilgic,
Itthi Chatnuntawech,
Mary Kate Manhard,
Qiyuan Tian,
Congyu Liao,
Stephen F. Cauley,
Susie Y. Huang,
Jonathan R. Polimeni,
Lawrence L. Wald,
Kawin Setsompop
Abstract:
Purpose: To introduce a combined machine learning (ML) and physics-based image reconstruction framework that enables navigator-free, highly accelerated multishot echo planar imaging (msEPI), and demonstrate its application in high-resolution structural and diffusion imaging.
Methods: Singleshot EPI is an efficient encoding technique, but does not lend itself well to high-resolution imaging due t…
▽ More
Purpose: To introduce a combined machine learning (ML) and physics-based image reconstruction framework that enables navigator-free, highly accelerated multishot echo planar imaging (msEPI), and demonstrate its application in high-resolution structural and diffusion imaging.
Methods: Singleshot EPI is an efficient encoding technique, but does not lend itself well to high-resolution imaging due to severe distortion artifacts and blurring. While msEPI can mitigate these artifacts, high-quality msEPI has been elusive because of phase mismatch arising from shot-to-shot variations which preclude the combination of the multiple-shot data into a single image. We employ deep learning to obtain an interim image with minimal artifacts, which permits estimation of image phase variations due to shot-to-shot changes. These variations are then included in a Joint Virtual Coil Sensitivity Encoding (JVC-SENSE) reconstruction to utilize data from all shots and improve upon the ML solution.
Results: Our combined ML + physics approach enabled Rinplane x MultiBand (MB) = 8x2-fold acceleration using 2 EPI-shots for multi-echo imaging, so that whole-brain T2 and T2* parameter maps could be derived from an 8.3 sec acquisition at 1x1x3mm3 resolution. This has also allowed high-resolution diffusion imaging with high geometric fidelity using 5-shots at Rinplane x MB = 9x2-fold acceleration. To make these possible, we extended the state-of-the-art MUSSELS reconstruction technique to Simultaneous MultiSlice (SMS) encoding and used it as an input to our ML network.
Conclusion: Combination of ML and JVC-SENSE enabled navigator-free msEPI at higher accelerations than previously possible while using fewer shots, with reduced vulnerability to poor generalizability and poor acceptance of end-to-end ML approaches.
△ Less
Submitted 24 March, 2019; v1 submitted 8 August, 2018;
originally announced August 2018.
-
Distributed NEGF Algorithms for the Simulation of Nanoelectronic Devices with Scattering
Authors:
Stephen Cauley,
Mathieu Luisier,
Venkataramanan Balakrishnan,
Gerhard Klimeck,
Cheng-Kok Koh
Abstract:
Through the Non-Equilibrium Green's Function (NEGF) formalism, quantum-scale device simulation can be performed with the inclusion of electron-phonon scattering. However, the simulation of realistically sized devices under the NEGF formalism typically requires prohibitive amounts of memory and computation time. Two of the most demanding computational problems for NEGF simulation involve mathematic…
▽ More
Through the Non-Equilibrium Green's Function (NEGF) formalism, quantum-scale device simulation can be performed with the inclusion of electron-phonon scattering. However, the simulation of realistically sized devices under the NEGF formalism typically requires prohibitive amounts of memory and computation time. Two of the most demanding computational problems for NEGF simulation involve mathematical operations with structured matrices called semiseparable matrices. In this work, we present parallel approaches for these computational problems which allow for efficient distribution of both memory and computation based upon the underlying device structure. This is critical when simulating realistically sized devices due to the aforementioned computational burdens. First, we consider determining a distributed compact representation for the retarded Green's function matrix $G^{R}$. This compact representation is exact and allows for any entry in the matrix to be generated through the inherent semiseparable structure. The second parallel operation allows for the computation of electron density and current characteristics for the device. Specifically, matrix products between the distributed representation for the semiseparable matrix $G^{R}$ and the self-energy scattering terms in $Σ^{<}$ produce the less-than Green's function $G^{<}$. As an illustration of the computational efficiency of our approach, we stably generate the mobility for nanowires with cross-sectional sizes of up to 4.5nm, assuming an atomistic model with scattering.
△ Less
Submitted 29 March, 2011;
originally announced March 2011.