Free-moving Quantitative Gamma-ray Imaging
Authors:
Daniel Hellfeld,
Mark S. Bandstra,
Jayson R. Vavrek,
Donald L. Gunter,
Joseph C. Curtis,
Marco Salathe,
Ryan Pavlovsky,
Victor Negut,
Paul J. Barton,
Joshua W. Cates,
Brian J. Quiter,
Reynold J. Cooper,
Kai Vetter,
Tenzing H. Y. Joshi
Abstract:
The ability to map and estimate the activity of radiological source distributions in unknown three-dimensional environments has applications in the prevention and response to radiological accidents or threats as well as the enforcement and verification of international nuclear non-proliferation agreements. Such a capability requires well-characterized detector response functions, accurate time-dep…
▽ More
The ability to map and estimate the activity of radiological source distributions in unknown three-dimensional environments has applications in the prevention and response to radiological accidents or threats as well as the enforcement and verification of international nuclear non-proliferation agreements. Such a capability requires well-characterized detector response functions, accurate time-dependent detector position and orientation data, a digitized representation of the surrounding 3D environment, and appropriate image reconstruction and uncertainty quantification methods. We have previously demonstrated 3D map** of gamma-ray emitters with free-moving detector systems on a relative intensity scale using a technique called Scene Data Fusion (SDF). Here we characterize the detector response of a multi-element gamma-ray imaging system using experimentally benchmarked Monte Carlo simulations and perform 3D map** on an absolute intensity scale. We present experimental reconstruction results from hand-carried and airborne measurements with point-like and distributed sources in known configurations, demonstrating quantitative SDF in complex 3D environments.
△ Less
Submitted 19 October, 2021; v1 submitted 8 July, 2021;
originally announced July 2021.
-
Improved Gamma-Ray Point Source Quantification in Three Dimensions by Modeling Attenuation in the Scene
Authors:
M. S. Bandstra,
D. Hellfeld,
J. R. Vavrek,
B. J. Quiter,
K. Meehan,
P. J. Barton,
J. W. Cates,
A. Moran,
V. Negut,
R. Pavlovsky,
T. H. Y. Joshi
Abstract:
Using a series of detector measurements taken at different locations to localize a source of radiation is a well-studied problem. The source of radiation is sometimes constrained to a single point-like source, in which case the location of the point source can be found using techniques such as maximum likelihood. Recent advancements have shown the ability to locate point sources in 2D and even 3D,…
▽ More
Using a series of detector measurements taken at different locations to localize a source of radiation is a well-studied problem. The source of radiation is sometimes constrained to a single point-like source, in which case the location of the point source can be found using techniques such as maximum likelihood. Recent advancements have shown the ability to locate point sources in 2D and even 3D, but few have studied the effect of intervening material on the problem. In this work we examine gamma-ray data taken from a freely moving system and develop voxelized 3-D models of the scene using data from the onboard LiDAR. Ray casting is used to compute the distance each gamma ray travels through the scene material, which is then used to calculate attenuation assuming a single attenuation coefficient for solids within the geometry. Parameter estimation using maximum likelihood is performed to simultaneously find the attenuation coefficient, source activity, and source position that best match the data. Using a simulation, we validate the ability of this method to reconstruct the true location and activity of a source, along with the true attenuation coefficient of the structure it is inside, and then we apply the method to measured data with sources and find good agreement.
△ Less
Submitted 4 October, 2021; v1 submitted 22 April, 2021;
originally announced April 2021.
-
Reconstructing the Position and Intensity of Multiple Gamma-Ray Point Sources with a Sparse Parametric Algorithm
Authors:
Jayson R. Vavrek,
Daniel Hellfeld,
Mark S. Bandstra,
Victor Negut,
Kathryn Meehan,
William J. Vanderlip,
Joshua W. Cates,
Ryan Pavlovsky,
Brian J. Quiter,
Reynold J. Cooper,
Tenzing H. Y. Joshi
Abstract:
We present an experimental demonstration of Additive Point Source Localization (APSL), a sparse parametric imaging algorithm that reconstructs the 3D positions and activities of multiple gamma-ray point sources. Using a handheld gamma-ray detector array and up to four $8$ $μ$Ci $^{137}$Cs gamma-ray sources, we performed both source-search and source-separation experiments in an indoor laboratory e…
▽ More
We present an experimental demonstration of Additive Point Source Localization (APSL), a sparse parametric imaging algorithm that reconstructs the 3D positions and activities of multiple gamma-ray point sources. Using a handheld gamma-ray detector array and up to four $8$ $μ$Ci $^{137}$Cs gamma-ray sources, we performed both source-search and source-separation experiments in an indoor laboratory environment. In the majority of the source-search measurements, APSL reconstructed the correct number of sources with position accuracies of ${\sim}20$ cm and activity accuracies (unsigned) of ${\sim}20\%$, given measurement times of two to three minutes and distances of closest approach (to any source) of ${\sim}20$ cm. In source-separation measurements where the detector could be moved freely about the environment, APSL was able to resolve two sources separated by $75$ cm or more given only ${\sim}60$ s of measurement time. In these source-separation measurements, APSL produced larger total activity errors of ${\sim}40\%$, but obtained source separation distances accurate to within $15$ cm. We also compare our APSL results against traditional Maximum Likelihood-Expectation Maximization (ML-EM) reconstructions, and demonstrate improved image accuracy and interpretability using APSL over ML-EM. These results indicate that APSL is capable of accurately reconstructing gamma-ray source positions and activities using measurements from existing detector hardware.
△ Less
Submitted 15 September, 2020;
originally announced September 2020.
-
3D Gamma-ray and Neutron Map** in Real-Time with the Localization and Map** Platform from Unmanned Aerial Systems and Man-Portable Configurations
Authors:
R. Pavlovsky,
J. W. Cates,
W. J. Vanderlip,
T. H. Y. Joshi,
A. Haefner,
E. Suzuki,
R. Barnowski,
V. Negut,
A. Moran,
K. Vetter,
B. J. Quiter
Abstract:
Nuclear Scene Data Fusion (SDF), implemented in the Localization and Map** Platform (LAMP) fuses three-dimensional (3D), real-time volumetric reconstructions of radiation sources with contextual information (e.g. LIDAR, camera, etc.) derived from the environment around the detector system. This information, particularly when obtained in real time, may be transformative for applications, includin…
▽ More
Nuclear Scene Data Fusion (SDF), implemented in the Localization and Map** Platform (LAMP) fuses three-dimensional (3D), real-time volumetric reconstructions of radiation sources with contextual information (e.g. LIDAR, camera, etc.) derived from the environment around the detector system. This information, particularly when obtained in real time, may be transformative for applications, including directed search for lost or stolen sources, consequence management after the release of radioactive materials, or contamination avoidance in security-related or emergency response scenarios. 3D reconstructions enabled by SDF localize contamination or hotspots to specific areas or objects, providing higher resolution over larger areas than conventional 2D approaches, and enabling more efficient planning and response, particularly in complex 3D environments.
In this work, we present the expansion of these gamma-ray map** concepts to neutron source localization. Here we integrate LAMP with a custom $Cs_2LiLa(Br,Cl)_6:Ce$ (CLLBC) scintillator detector sensitive to both gamma-rays and neutrons, which we dub Neutron Gamma LAMP (NG-LAMP). NG-LAMP enables simultaneous neutron and gamma-ray map** with high resolution gamma-ray spectroscopy. We demonstrate the ability to detect and localize surrogate Special Nuclear Materials (SNM) in real-time and in 3D based on neutron signatures alone, which is critical for the detection of heavily shielded SNM, when gamma-ray signatures are attenuated. In this work, we show for the first time the ability to localize, in 3D and realtime, a neutron source in the presence of a strong gamma-ray source, simultaneous and spectroscopic localization of three gamma-ray sources and a neutron source, and finally the localization of a surrogate SNM source based on neutron signatures alone, where gamma-ray data are consistent with background.
△ Less
Submitted 16 August, 2019;
originally announced August 2019.