-
Millikelvin scanning tunneling microscope at 20/22 T with a graphite enabled stick-slip approach and an energy resolution below 8$μ$eV: Application to conductance quantization at 20 T in single atom point contacts of Al and Au
Authors:
Marta Fernández Lomana,
Beilun Wu,
Francisco Martín-Vega,
Raquel Sánchez Barquilla,
Rafael Álvarez Montoya,
José María Castilla,
José Navarrete,
Juan Ramón Marijuan,
Edwin Herrera,
Hermann Suderow,
Isabel Guillamón
Abstract:
We describe a scanning tunneling microscope (STM) that operates at magnetic fields up to 22 Tesla and temperatures down to 80 mK. We discuss the design of the STM head, with an improved coarse approach, the vibration isolation system, and efforts to improve the energy resolution using compact filters for multiple lines. We measure the superconducting gap and Josephson effect in Aluminum and show t…
▽ More
We describe a scanning tunneling microscope (STM) that operates at magnetic fields up to 22 Tesla and temperatures down to 80 mK. We discuss the design of the STM head, with an improved coarse approach, the vibration isolation system, and efforts to improve the energy resolution using compact filters for multiple lines. We measure the superconducting gap and Josephson effect in Aluminum and show that we can resolve features in the density of states as small as 8\,$μ$eV. We measure the quantization of conductance in atomic size contacts and make atomic resolution and density of states images in the layered material 2H-NbSe$_2$. The latter experiments are performed by continuously operating the STM at magnetic fields of 20 T in periods of several days without interruption.
△ Less
Submitted 6 August, 2021;
originally announced August 2021.
-
One-dimensional moire charge density wave in the hidden order state of URu2Si2 induced by fracture
Authors:
Edwin Herrera,
Victor Barrena,
Isabel Guillamon,
Jose Augusto Galvis,
William J. Herrera,
Jose Castilla,
Dai Aoki,
Jacques Flouquet,
Hermann Suderow
Abstract:
Moiré patterns can lead to fundamentally new electronic behavior when formed between two atomic lattices slightly shifted with respect to each other. A solid is however not just characterized by the atomic lattice, but also by charge or magnetic excitations that do not need to be commensurate to the lattice. This raises the question if one can obtain a moiré by combining periodic electronic modula…
▽ More
Moiré patterns can lead to fundamentally new electronic behavior when formed between two atomic lattices slightly shifted with respect to each other. A solid is however not just characterized by the atomic lattice, but also by charge or magnetic excitations that do not need to be commensurate to the lattice. This raises the question if one can obtain a moiré by combining periodic electronic modulations and the atomic lattice. Here we report on the discovery of a one-dimensional charge density wave (1D-CDW) which is a moiré pattern between the atomic lattice and a hot spot for electronic scattering in the bandstructure of the hidden order (HO) state of URu$_2$Si$_2$. The moiré is produced by fracturing the crystal at low temperatures. Our results suggest that charge interactions are among the most relevant features competing with HO in URu$_2$Si$_2$.
△ Less
Submitted 8 June, 2020; v1 submitted 17 March, 2020;
originally announced March 2020.
-
The Physics of the Accelerating Universe Camera
Authors:
Cristobal Padilla,
Francisco J. Castander,
Alex Alarcon,
Jelena Aleksic,
Otger Ballester,
Laura Cabayol,
Laia Cardiel-Sas,
Jorge Carretero,
Ricard Casas,
Javier Castilla,
Martin Crocce,
Manuel Delfino,
Carlos Diaz,
Martin Eriksen,
Enrique Fernandez,
Pablo Fosalba,
Juan Garcia-Bellido,
Enrique Gaztanaga,
Javier Gaweda,
Ferran Granena,
Jose Maria Illa,
Jorge Jimenez,
Luis Lopez,
Pol Marti,
Ramon Miquel
, et al. (8 additional authors not shown)
Abstract:
The PAU (Physics of the Accelerating Universe) Survey goal is to obtain photometric redshifts (photo-z) and Spectral Energy Distribution (SED) of astronomical objects with a resolution roughly one order of magnitude better than current broad band photometric surveys. To accomplish this, a new large field of view camera (PAUCam) has been designed, built, commissioned and is now operated at the Will…
▽ More
The PAU (Physics of the Accelerating Universe) Survey goal is to obtain photometric redshifts (photo-z) and Spectral Energy Distribution (SED) of astronomical objects with a resolution roughly one order of magnitude better than current broad band photometric surveys. To accomplish this, a new large field of view camera (PAUCam) has been designed, built, commissioned and is now operated at the William Herschel Telescope (WHT). With the current WHT Prime Focus corrector, the camera covers ~1-degree diameter Field of View (FoV), of which, only the inner ~40 arcmin diameter are unvignetted. The focal plane consists of a mosaic of 18 2k$x4k Hamamatsu fully depleted CCDs, with high quantum efficiency up to 1 micrometers in wavelength. To maximize the detector coverage within the FoV, filters are placed in front of the CCDs inside the camera cryostat (made out of carbon fiber) using a challenging movable tray system. The camera uses a set of 40 narrow band filters ranging from ~4500 to ~8500 Angstroms complemented with six standard broad-band filters, ugrizY. The PAU Survey aims to cover roughly 100 square degrees over fields with existing deep photometry and galaxy shapes to obtain accurate photometric redshifts for galaxies down to i_AB~22.5, detecting also galaxies down to i_AB~24 with less precision in redshift. With this data set we will be able to measure intrinsic alignments, galaxy clustering and perform galaxy evolution studies in a new range of densities and redshifts. Here, we describe the PAU camera, its first commissioning results and performance.
△ Less
Submitted 28 March, 2019; v1 submitted 10 February, 2019;
originally announced February 2019.
-
Methods to simplify cooling of liquid Helium cryostats
Authors:
Rafael Alvarez Montoya,
Sara Delgado,
Jose Castilla,
Jose Navarrete,
Nuria Diaz Contreras,
Juan Ramon Marijuan,
Victor Barrena,
Isabel Guillamon,
Hermann Suderow
Abstract:
Liquid Helium is used widely, from hospitals to characterization of materials at low temperatures. Many experiments at low temperatures require liquid Helium, particularly when vibration isolation precludes the use of cryocoolers and when one needs to cool heavy equipment such as superconducting coils. Here we describe methods to simplify the operations required to use liquid Helium by eliminating…
▽ More
Liquid Helium is used widely, from hospitals to characterization of materials at low temperatures. Many experiments at low temperatures require liquid Helium, particularly when vibration isolation precludes the use of cryocoolers and when one needs to cool heavy equipment such as superconducting coils. Here we describe methods to simplify the operations required to use liquid Helium by eliminating the use of high pressure bottles, avoiding blockage and improving heating and cooling rates. First we show a simple and very low cost method to transfer liquid Helium from a transport container into a cryostat that uses a manual pump having pum** and pressurizing ports, giving a liquid Helium transfer rate of about 100 liters an hour. Second, we describe a closed cycle circuit of Helium gas cooled in an external liquid nitrogen bath that allows precooling a cryogenic experiment without inserting liquid nitrogen into the cryostat, eliminating problems associated to the presence of nitrogen around superconducting magnets. And third, we show a sliding seal assembly and an inner vacuum chamber design that allows inserting large experiments into liquid Helium.
△ Less
Submitted 19 January, 2019;
originally announced January 2019.
-
Calorimetric Measurements at Low Temperatures in Toluene Glass and Crystal
Authors:
C. Alvarez-Ney,
J. Labarga,
M. Moratalla,
J. M. Castilla,
M. A. Ramos
Abstract:
The specific heat of toluene in glass and crystal states, has been measured both at low temperatures down to 1.8 K (using the thermal relaxation method) and in a wide temperature range up to the liquid state (using a quasiadiabatic continuous method). Our measurements therefore extend earlier published data to much lower temperatures, thereby allowing to explore the low temperature glassy anomalie…
▽ More
The specific heat of toluene in glass and crystal states, has been measured both at low temperatures down to 1.8 K (using the thermal relaxation method) and in a wide temperature range up to the liquid state (using a quasiadiabatic continuous method). Our measurements therefore extend earlier published data to much lower temperatures, thereby allowing to explore the low temperature glassy anomalies in the case of toluene. Surprisingly, no indication of the existence of tunneling states is found, at least within the temperature range studied. At moderate temperatures, our data either for the glass or for the crystal show good agreement with those found in the literature. Also, we have been able to prepare bulk samples of toluene glass by only do** with 2% mol ethanol instead of with higher impurity doses used by other authors.
△ Less
Submitted 7 March, 2017;
originally announced March 2017.
-
The Dark Energy Camera
Authors:
B. Flaugher,
H. T. Diehl,
K. Honscheid,
T. M. C. Abbott,
O. Alvarez,
R. Angstadt,
J. T. Annis,
M. Antonik,
O. Ballester,
L. Beaufore,
G. M. Bernstein,
R. A. Bernstein,
B. Bigelow,
M. Bonati,
D. Boprie,
D. Brooks,
E. J. Buckley-Geer,
J. Campa,
L. Cardiel-Sas,
F. J. Castander,
J. Castilla,
H. Cease,
J. M. Cela-Ruiz,
S. Chappa,
E. Chi
, et al. (93 additional authors not shown)
Abstract:
The Dark Energy Camera is a new imager with a 2.2-degree diameter field of view mounted at the prime focus of the Victor M. Blanco 4-meter telescope on Cerro Tololo near La Serena, Chile. The camera was designed and constructed by the Dark Energy Survey Collaboration, and meets or exceeds the stringent requirements designed for the wide-field and supernova surveys for which the collaboration uses…
▽ More
The Dark Energy Camera is a new imager with a 2.2-degree diameter field of view mounted at the prime focus of the Victor M. Blanco 4-meter telescope on Cerro Tololo near La Serena, Chile. The camera was designed and constructed by the Dark Energy Survey Collaboration, and meets or exceeds the stringent requirements designed for the wide-field and supernova surveys for which the collaboration uses it. The camera consists of a five element optical corrector, seven filters, a shutter with a 60 cm aperture, and a CCD focal plane of 250 micron thick fully-depleted CCDs cooled inside a vacuum Dewar. The 570 Mpixel focal plane comprises 62 2kx4k CCDs for imaging and 12 2kx2k CCDs for guiding and focus. The CCDs have 15 microns x15 microns pixels with a plate scale of 0.263 arc sec per pixel. A hexapod system provides state-of-the-art focus and alignment capability. The camera is read out in 20 seconds with 6-9 electrons readout noise. This paper provides a technical description of the camera's engineering, construction, installation, and current status.
△ Less
Submitted 11 April, 2015;
originally announced April 2015.
-
Measuring Baryon Acoustic Oscillations along the line of sight with photometric redshifs: the PAU survey
Authors:
N. Benitez,
E. Gaztanaga,
R. Miquel,
F. Castander,
M. Moles,
M. Crocce,
A. Fernandez-Soto,
P. Fosalba,
F. Ballesteros,
J. Campa,
L. Cardiel-Sas,
J. Castilla,
D. Cristobal-Hornillos,
M. Delfino,
E. Fernandez,
C. Fernandez-Sopuerta,
J. Garcia-Bellido,
J. A. Lobo,
V. J. Martinez,
A. Ortiz,
A. Pacheco,
S. Paredes,
M. J. Pons-Borderia,
E. Sanchez,
S. F. Sanchez
, et al. (2 additional authors not shown)
Abstract:
Baryon Acoustic Oscillations (BAO) provide a standard ruler of known physical length, making it a promising probe of the nature of dark energy. The detection of BAO requires measuring galaxy positions and redshifts. "Transversal" (angular distance) BAO measure the angular size of this scale, while "line-of-sight" (or "radial") BAO require precise redshifts, but provide a direct measurement of th…
▽ More
Baryon Acoustic Oscillations (BAO) provide a standard ruler of known physical length, making it a promising probe of the nature of dark energy. The detection of BAO requires measuring galaxy positions and redshifts. "Transversal" (angular distance) BAO measure the angular size of this scale, while "line-of-sight" (or "radial") BAO require precise redshifts, but provide a direct measurement of the Hubble parameter at different redshifts, a more sensitive probe of dark energy. The main goal of this paper is to show that a precision of sigma_z ~0.003(1 + z) is sufficient to measure BAO in the radial direction. This precision can be achieved for bright, red galaxies, by using a filter system comprising about 40 filters, each with a width of ~100 A, from ~ 4000 A to ~ 8000 A, supplemented by two broad-band filters. We describe a practical implementation, a new galaxy survey, PAU, to be carried out with a telescope/camera combination with an etendue of about 20 m^2deg^2, and covering 8000 sq. deg. in the sky in four years. We expect to measure positions and redshifts for over 14 million red, early-type galaxies with L > L* and i_AB < 22.5 in the interval 0.1 < z < 0.9, with sigma_z < 0.003(1 + z). This population has a number density n > 10^-3 Mpc^-3 h^3 within the 9 (Gpc/h)^3 volume of the survey, ensuring that the error in the determination of the BAO scale is not limited by shot-noise. By itself, such a survey will deliver precisions of order 5% in the dark-energy equation of state parameter w, if assumed constant, and can determine its time derivative when combined with future CMB measurements. In addition, PAU will yield high-quality redshift and low-resolution spectroscopy for hundreds of millions of other galaxies.
△ Less
Submitted 6 March, 2009; v1 submitted 3 July, 2008;
originally announced July 2008.