-
High Strain Engineering of a Suspended WSSe Monolayer Membrane by Indentation and Measured by Tip-enhanced Photoluminescence
Authors:
Anis Chiout,
Agnès Tempez,
Thomas Carlier,
Marc Chaigneau,
Fabian Cadiz,
Alistair Rowe,
Biyuan Zheng,
Anlian Pan,
Marco Pala,
Fabrice Oehler,
Abdelkarim Ouerghi,
Julien Chaste
Abstract:
Straintronics involves the manipulation and regulation of the electronic characteristics of 2D materials through the use of macro- and nano-scale strain engineering. In this study, we utilized an atomic force microscope (AFM) coupled with an optical system to perform indentation measurements and tip-enhanced photoluminescence (TEPL), allowing us to extract the local optical response of a suspended…
▽ More
Straintronics involves the manipulation and regulation of the electronic characteristics of 2D materials through the use of macro- and nano-scale strain engineering. In this study, we utilized an atomic force microscope (AFM) coupled with an optical system to perform indentation measurements and tip-enhanced photoluminescence (TEPL), allowing us to extract the local optical response of a suspended monolayer membrane of ternary WSSe at various levels of deformation, up to strains of 10%. The photoluminescence signal is modelled considering the deformation, stress distribution and strain dependence of the WSSe band structure. We observe an additional TEPL signal that exhibits significant variation under strain, with 64 meV per percent of elongation. This peak is linked to the highly strained 2D material lying right underneath the tip. We discuss the amplification of the signal and its relation to the excitonic funnelling effect in a more comprehensive model. We will also compare the diffusion caused by Auger recombination against the radiative excitonic decay. We use TEPL to examine and comprehend the local physics of 2D semi-conducting materials subjected to extreme mechanical strain. Chemical vapour deposition-fabricated 2D ternaries possess high strain resistance, comparable to the benchmark MoS2, and a high Young's modulus of 273 GPa.
△ Less
Submitted 5 February, 2024;
originally announced February 2024.
-
Graph-based multimodal multi-lesion DLBCL treatment response prediction from PET images
Authors:
Oriane Thiery,
Mira Rizkallah,
Clément Bailly,
Caroline Bodet-Milin,
Emmanuel Itti,
René-Olivier Casasnovas,
Steven Le Gouill,
Thomas Carlier,
Diana Mateus
Abstract:
Diffuse Large B-cell Lymphoma (DLBCL) is a lymphatic cancer involving one or more lymph nodes and extranodal sites. Its diagnostic and follow-up rely on Positron Emission Tomography (PET) and Computed Tomography (CT). After diagnosis, the number of nonresponding patients to standard front-line therapy remains significant (30-40%). This work aims to develop a computer-aided approach to identify hig…
▽ More
Diffuse Large B-cell Lymphoma (DLBCL) is a lymphatic cancer involving one or more lymph nodes and extranodal sites. Its diagnostic and follow-up rely on Positron Emission Tomography (PET) and Computed Tomography (CT). After diagnosis, the number of nonresponding patients to standard front-line therapy remains significant (30-40%). This work aims to develop a computer-aided approach to identify high-risk patients requiring adapted treatment by efficiently exploiting all the information available for each patient, including both clinical and image data. We propose a method based on recent graph neural networks that combine imaging information from multiple lesions, and a cross-attention module to integrate different data modalities efficiently. The model is trained and evaluated on a private prospective multicentric dataset of 583 patients. Experimental results show that our proposed method outperforms classical supervised methods based on either clinical, imaging or both clinical and imaging data for the 2-year progression-free survival (PFS) classification accuracy.
△ Less
Submitted 25 October, 2023;
originally announced October 2023.
-
Reconstruction multiclasse pour l'imagerie TEP 3-photons
Authors:
Mehdi Latif,
Jérôme Idier,
Thomas Carlier,
Simon Stute
Abstract:
This contribution addresses the problem of image reconstruction of radioactivity distribution for which the available information arises from several classes of data, each associated with a specific combination of detections. We introduce a theoretical framework to measure the amount of information brought by each class and we develop an iterative algorithm dedicated to multi-class reconstruction…
▽ More
This contribution addresses the problem of image reconstruction of radioactivity distribution for which the available information arises from several classes of data, each associated with a specific combination of detections. We introduce a theoretical framework to measure the amount of information brought by each class and we develop an iterative algorithm dedicated to multi-class reconstruction based on maximum likelihood.We apply our approach to the XEMIS2 camera, a preclinical prototype of a Compton telescope dedicated to 3-photon PET imaging for which four distinct classes of partial detections coexist with the full detection class.Based on Monte Carlo simulations, we present the first elements of our model.
△ Less
Submitted 11 September, 2023;
originally announced September 2023.
-
Local-mean preserving post-processing step for non-negativity enforcement in PET imaging: application to $^{90}$Y-PET
Authors:
Maël Millardet,
Saïd Moussaoui,
Diana Mateus,
Jérôme Idier,
Thomas Carlier
Abstract:
In a low-statistics PET imaging context, the positive bias in regions of low activity is a burning issue. To overcome this problem, algorithms without the built-in non-negativity constraint may be used. They allow negative voxels in the image to reduce, or even to cancel the bias. However, such algorithms increase the variance and are difficult to interpret, since negative radioactive concentratio…
▽ More
In a low-statistics PET imaging context, the positive bias in regions of low activity is a burning issue. To overcome this problem, algorithms without the built-in non-negativity constraint may be used. They allow negative voxels in the image to reduce, or even to cancel the bias. However, such algorithms increase the variance and are difficult to interpret, since negative radioactive concentrations have no physical meaning. Here, we propose a post-processing strategy to remove negative intensities while preserving the local mean activities. Our idea is to transfer the negative intensities to neighboring voxels, so that the mean of the image is preserved. The proposed post-processing algorithm solves a linear programming problem with a specific symmetric structure, and the solution can be computed in a very efficient way. Acquired data from an yttrium-90 phantom show that on images produced by a non-constrained algorithm, a much lower variance in the cold area is obtained after the post-processing step.
△ Less
Submitted 11 December, 2020;
originally announced December 2020.