-
Field emission from two-dimensional GeAs
Authors:
Antonio Di Bartolomeo,
Alessandro Grillo,
Filippo Giubileo,
Luca Camilli,
Jianbo Sun,
Daniele Capista,
Maurizio Passacantando
Abstract:
GeAs is a layered material of the IV-V groups that is attracting growing attention for possible applications in electronic and optoelectronic devices. In this study, exfoliated multilayer GeAs nanoflakes are structurally characterized and used as the channel of back-gate field-effect transistors. It is shown that their gate-modulated p-type conduction is decreased by exposure to light or electron…
▽ More
GeAs is a layered material of the IV-V groups that is attracting growing attention for possible applications in electronic and optoelectronic devices. In this study, exfoliated multilayer GeAs nanoflakes are structurally characterized and used as the channel of back-gate field-effect transistors. It is shown that their gate-modulated p-type conduction is decreased by exposure to light or electron beam. Moreover, the observation of a field emission current demonstrates the suitability of GeAs nanoflakes as cold cathodes for electron emission and opens up new perspective applications of two-dimensional GeAs in vacuum electronics. Field emission occurs with a turn-on field of ~80 V/μm and attains a current density higher than 10 A/cm^2, following the general Fowler-Nordheim model with high reproducibility.
△ Less
Submitted 11 July, 2020;
originally announced July 2020.
-
Beam Extraction From The Recycler Ring To P1 Line At Fermilab
Authors:
M. Xiao,
D. Capista,
P. Adams,
D. Morris,
M. J. Yang,
K. Hazewood
Abstract:
The transfer line for beam extraction from the Recycler ring to P1 line provides a way to deliver 8 GeV kinetic energy protons from the Booster to the Delivery ring, via the Recycler, using existing beam transport lines, and without the need for new civil construction. It was designed in 2012. The kicker magnets at RR520 and the lambertson magnet at RR522 in the RR were installed in 2014 Summer Sh…
▽ More
The transfer line for beam extraction from the Recycler ring to P1 line provides a way to deliver 8 GeV kinetic energy protons from the Booster to the Delivery ring, via the Recycler, using existing beam transport lines, and without the need for new civil construction. It was designed in 2012. The kicker magnets at RR520 and the lambertson magnet at RR522 in the RR were installed in 2014 Summer Shutdown, the elements of RR to P1 Stub (permanent quads, trim quads, correctors, BPMs, the toroid at 703 and vertical bending dipole at V703 (ADCW) were installed in 2015 Summer Shutdown. On Tuesday, June 21, 2016, beam line from the Recycler Ring to P1 line was commissioned. The detailed results will be presented in this report.
△ Less
Submitted 16 February, 2017;
originally announced February 2017.
-
First measurement of muon-neutrino disappearance in NOvA
Authors:
P. Adamson,
C. Ader,
M. Andrews,
N. Anfimov,
I. Anghel,
K. Arms,
E. Arrieta-Diaz,
A. Aurisano,
D. Ayres,
C. Backhouse,
M. Baird,
B. A. Bambah,
K. Bays,
R. Bernstein,
M. Betancourt,
V. Bhatnagar,
B. Bhuyan,
J. Bian,
K. Biery,
T. Blackburn,
V. Bocean,
D. Bogert,
A. Bolshakova,
M. Bowden,
C. Bower
, et al. (235 additional authors not shown)
Abstract:
This paper reports the first measurement using the NOvA detectors of $ν_μ$ disappearance in a $ν_μ$ beam. The analysis uses a 14 kton-equivalent exposure of $2.74 \times 10^{20}$ protons-on-target from the Fermilab NuMI beam. Assuming the normal neutrino mass hierarchy, we measure $Δm^{2}_{32}=(2.52^{+0.20}_{-0.18})\times 10^{-3}$ eV$^{2}$ and $\sin^2θ_{23}$ in the range 0.38-0.65, both at the 68%…
▽ More
This paper reports the first measurement using the NOvA detectors of $ν_μ$ disappearance in a $ν_μ$ beam. The analysis uses a 14 kton-equivalent exposure of $2.74 \times 10^{20}$ protons-on-target from the Fermilab NuMI beam. Assuming the normal neutrino mass hierarchy, we measure $Δm^{2}_{32}=(2.52^{+0.20}_{-0.18})\times 10^{-3}$ eV$^{2}$ and $\sin^2θ_{23}$ in the range 0.38-0.65, both at the 68% confidence level, with two statistically-degenerate best fit points at $\sin^2θ_{23} = $ 0.43 and 0.60. Results for the inverted mass hierarchy are also presented.
△ Less
Submitted 20 January, 2016; v1 submitted 19 January, 2016;
originally announced January 2016.
-
First measurement of electron neutrino appearance in NOvA
Authors:
P. Adamson,
C. Ader,
M. Andrews,
N. Anfimov,
I. Anghel,
K. Arms,
E. Arrieta-Diaz,
A. Aurisano,
D. S. Ayres,
C. Backhouse,
M. Baird,
B. A. Bambah,
K. Bays,
R. Bernstein,
M. Betancourt,
V. Bhatnagar,
B. Bhuyan,
J. Bian,
K. Biery,
T. Blackburn,
V. Bocean,
D. Bogert,
A. Bolshakova,
M. Bowden,
C. Bower
, et al. (235 additional authors not shown)
Abstract:
We report results from the first search for $ν_μ\toν_e$ transitions by the NOvA experiment. In an exposure equivalent to $2.74\times10^{20}$ protons-on-target in the upgraded NuMI beam at Fermilab, we observe 6 events in the Far Detector, compared to a background expectation of $0.99\pm0.11$ (syst.) events based on the Near Detector measurement. A secondary analysis observes 11 events with a backg…
▽ More
We report results from the first search for $ν_μ\toν_e$ transitions by the NOvA experiment. In an exposure equivalent to $2.74\times10^{20}$ protons-on-target in the upgraded NuMI beam at Fermilab, we observe 6 events in the Far Detector, compared to a background expectation of $0.99\pm0.11$ (syst.) events based on the Near Detector measurement. A secondary analysis observes 11 events with a background of $1.07\pm0.14$ (syst.). The $3.3σ$ excess of events observed in the primary analysis disfavors $0.1π< δ_{CP} < 0.5π$ in the inverted mass hierarchy at the 90% C.L.
△ Less
Submitted 2 May, 2016; v1 submitted 19 January, 2016;
originally announced January 2016.
-
The Fermilab Main Injector: high intensity operation and beam loss control
Authors:
Bruce C. Brown,
Philip Adamson,
David Capista,
Weiren Chou,
Ioanis Kourbanis,
Denton K Morris,
Kiyomi Seiya,
Guan Hong Wu,
Ming-Jen Yang
Abstract:
From 2005 through 2012, the Fermilab Main Injector provided intense beams of 120 GeV protons to produce neutrino beams and antiprotons. Hardware improvements in conjunction with improved diagnostics allowed the system to reach sustained operation at ~400 kW beam power. Transmission was very high except for beam lost at or near the 8 GeV injection energy where 95% beam transmission results in about…
▽ More
From 2005 through 2012, the Fermilab Main Injector provided intense beams of 120 GeV protons to produce neutrino beams and antiprotons. Hardware improvements in conjunction with improved diagnostics allowed the system to reach sustained operation at ~400 kW beam power. Transmission was very high except for beam lost at or near the 8 GeV injection energy where 95% beam transmission results in about 1.5 kW of beam loss. By minimizing and localizing loss, residual radiation levels fell while beam power was doubled. Lost beam was directed to either the collimation system or to the beam abort. Critical apertures were increased while improved instrumentation allowed optimal use of available apertures. We will summarize the improvements required to achieve high intensity, the impact of various loss control tools and the status and trends in residual radiation in the Main Injector.
△ Less
Submitted 10 July, 2013;
originally announced July 2013.
-
6 Batch Injection and Slipped Beam Tune Measurements in Fermilab's Main Injector
Authors:
D. J. Scott,
D. Capista,
I. Kourbanis,
K. Seiya,
M. -J. Yan
Abstract:
During Nova operations it is planned to run the Fermilab Recycler in a 12 batch slip stacking mode. In preparation for this, measurements of the tune during a six batch injection and then as the beam is slipped by changing the RF frequency, but without a 7th injection, have been carried out in the Main Injector. The coherent tune shifts due to the changing beam intensity were measured and compared…
▽ More
During Nova operations it is planned to run the Fermilab Recycler in a 12 batch slip stacking mode. In preparation for this, measurements of the tune during a six batch injection and then as the beam is slipped by changing the RF frequency, but without a 7th injection, have been carried out in the Main Injector. The coherent tune shifts due to the changing beam intensity were measured and compared well with the theoretically expected tune shift. The tune shifts due to changing RF frequency, required for slip stacking, also compare well with the linear theory, although some nonlinear affects are apparent at large frequency changes. These results give us confidence that the expected tunes shifts during 12 batch slip stacking Recycler operations can be accommodated.
△ Less
Submitted 30 January, 2013;
originally announced January 2013.
-
Coalescing at 8 GeV in the Fermilab Main Injector
Authors:
D. J. Scott,
D. Capista,
B. Chase,
J. Dye,
I. Kourbanis,
K. Seiya,
M. -J. Yang
Abstract:
For Project X, it is planned to inject a beam of 3 10**11 particles per bunch into the Main Injector. To prepare for this by studying the effects of higher intensity bunches in the Main Injector it is necessary to perform coalescing at 8 GeV. The results of a series of experiments and simulations of 8 GeV coalescing are presented. To increase the coalescing efficiency adiabatic reduction of the 53…
▽ More
For Project X, it is planned to inject a beam of 3 10**11 particles per bunch into the Main Injector. To prepare for this by studying the effects of higher intensity bunches in the Main Injector it is necessary to perform coalescing at 8 GeV. The results of a series of experiments and simulations of 8 GeV coalescing are presented. To increase the coalescing efficiency adiabatic reduction of the 53 MHz RF is required, resulting in ~70% coalescing efficiency of 5 initial bunches. Data using wall current monitors has been taken to compare previous work and new simulations for 53 MHz RF reduction, bunch rotations and coalescing, good agreement between experiment and simulation was found. Possible schemes to increase the coalescing efficiency and generate even higher intensity bunches are discussed. These require improving the timing resolution of the low level RF and/or tuning the adiabatic voltage reduction of the 53 MHz.
△ Less
Submitted 30 January, 2013;
originally announced January 2013.
-
Single/Few Bunch Space Charge Effects at 8-GeV in the Fermilab Main Injector
Authors:
D. J. Scott,
D. Capista,
I. Kourbanis,
K. Seiya,
M. -J. Yang
Abstract:
For Project X, it is planned to inject a beam of 3x10**11 particles per bunch into the Main Injector. Therefore, at 8-GeV, there will be increased space charge tune shifts and an increased incoherent tune spread. In preparation for these higher intensity bunches exploratory studies have commenced looking at the transmission of different intensity bunches at different tunes. An experiment is descri…
▽ More
For Project X, it is planned to inject a beam of 3x10**11 particles per bunch into the Main Injector. Therefore, at 8-GeV, there will be increased space charge tune shifts and an increased incoherent tune spread. In preparation for these higher intensity bunches exploratory studies have commenced looking at the transmission of different intensity bunches at different tunes. An experiment is described with results for bunch intensities between 20 and 300 10**9 particles. To achieve the highest intensity bunches coalescing at 8-GeV is required, resulting in a longer bunch length. Comparisons show that similar transmission curves are obtained when the intensity and bunch length have increased by factors of 3.2 and 3.4 respectively, indicating the incoherent tune shifts are similar, as expected from theory. The results of these experiments will be used in conjugation with simulations to further study high intensity bunches in the Main Injector.
△ Less
Submitted 29 January, 2013;
originally announced January 2013.
-
Secondary Electron Yield Measurements of Fermilab's Main Injector Vacuum Vessel
Authors:
D. J. Scott,
D. Capista,
K. L. Duel,
R. M. Zwaska,
S. Greenwald,
W. Hartung,
Y. Li,
T. P. Moore,
M. A. Palmer,
R. Kirby,
M. Pivi,
L. Wang
Abstract:
We discuss the progress made on a new installation in Fermilab's Main Injector that will help investigate the electron cloud phenomenon by making direct measurements of the secondary electron yield (SEY) of samples irradiated in the accelerator. In the Project X upgrade the Main Injector will have its beam intensity increased by a factor of three compared to current operations. This may result in…
▽ More
We discuss the progress made on a new installation in Fermilab's Main Injector that will help investigate the electron cloud phenomenon by making direct measurements of the secondary electron yield (SEY) of samples irradiated in the accelerator. In the Project X upgrade the Main Injector will have its beam intensity increased by a factor of three compared to current operations. This may result in the beam being subject to instabilities from the electron cloud. Measured SEY values can be used to further constrain simulations and aid our extrapolation to Project X intensities. The SEY test-stand, developed in conjunction with Cornell and SLAC, is capable of measuring the SEY from samples using an incident electron beam when the samples are biased at different voltages. We present the design and manufacture of the test-stand and the results of initial laboratory tests on samples prior to installation.
△ Less
Submitted 29 January, 2013;
originally announced January 2013.
-
Operational use of ionization profile monitors in the Fermilab Main Injector
Authors:
Denton K. Morris,
Philip Adamson,
David Capista,
Ioanis Kourbanis,
Thomas Meyer,
Kiyomi Seiya,
David Slimmer,
Ming-Jen Yang,
James Zagel
Abstract:
Ionization profile monitors (IPMs) are used in the Fermilab Main Injector (MI) to monitor injection lattice matching by measuring turn-by-turn sigmas at injection and to measure transverse emittance of the beam during the acceleration cycle. The IPMs provide a periodic, non-destructive means of performing turn-by-turn emittance measurements where other techniques are not applicable. As Fermilab is…
▽ More
Ionization profile monitors (IPMs) are used in the Fermilab Main Injector (MI) to monitor injection lattice matching by measuring turn-by-turn sigmas at injection and to measure transverse emittance of the beam during the acceleration cycle. The IPMs provide a periodic, non-destructive means of performing turn-by-turn emittance measurements where other techniques are not applicable. As Fermilab is refocusing its attention on the intensity frontier, non-intercepting diagnostics such as IPMs are expected to become even more important. This paper gives an overview of the operational use of IPMs for emittance measurements and injection lattice matching measurements at Fermilab, and summarizes the future plans.
△ Less
Submitted 6 September, 2012;
originally announced September 2012.
-
A gap clearing kicker for Main Injector
Authors:
I. Kourbanis,
P. Adamson,
J. Biggs,
B. Brown,
D. Capista,
C. C. Jensen,
G. E. Krafczyk,
D. K. Morris,
D. Scott,
K. Seiya,
S. R. Ward,
G. Wu,
M. -J. Yang
Abstract:
Fermilab Main Injector has been operating at high Beam Power levels since 2008 when multi-batch slip stacking became operational. In order to maintain and increase the beam power levels the localized beam loss due to beam left over in the injection kicker gap during slip stacking needs to be addressed. A set of gap clearing kickers that kick any beam left in the injection gap to the beam abort hav…
▽ More
Fermilab Main Injector has been operating at high Beam Power levels since 2008 when multi-batch slip stacking became operational. In order to maintain and increase the beam power levels the localized beam loss due to beam left over in the injection kicker gap during slip stacking needs to be addressed. A set of gap clearing kickers that kick any beam left in the injection gap to the beam abort have been built. The kickers were installed in the summer of 2009 and became operational in November of 2010. The kicker performance and its effect on the beam losses will be described.
△ Less
Submitted 16 August, 2012;
originally announced August 2012.
-
Demonstration of Communication using Neutrinos
Authors:
D. D. Stancil,
P. Adamson,
M. Alania,
L. Aliaga,
M. Andrews,
C. Araujo Del Castillo,
L. Bagby,
J. L. Bazo Alba,
A. Bodek,
D. Boehnlein,
R. Bradford,
W. K. Brooks,
H. Budd,
A. Butkevich,
D. A. M. Caicedo,
D. P. Capista,
C. M. Castromonte,
A. Chamorro,
E. Charlton,
M. E. Christy,
J. Chvojka,
P. D. Conrow,
I. Danko,
M. Day,
J. Devan
, et al. (87 additional authors not shown)
Abstract:
Beams of neutrinos have been proposed as a vehicle for communications under unusual circumstances, such as direct point-to-point global communication, communication with submarines, secure communications and interstellar communication. We report on the performance of a low-rate communications link established using the NuMI beam line and the MINERvA detector at Fermilab. The link achieved a decode…
▽ More
Beams of neutrinos have been proposed as a vehicle for communications under unusual circumstances, such as direct point-to-point global communication, communication with submarines, secure communications and interstellar communication. We report on the performance of a low-rate communications link established using the NuMI beam line and the MINERvA detector at Fermilab. The link achieved a decoded data rate of 0.1 bits/sec with a bit error rate of 1% over a distance of 1.035 km, including 240 m of earth.
△ Less
Submitted 9 April, 2012; v1 submitted 13 March, 2012;
originally announced March 2012.
-
The upgraded data acquisition system for beam loss monitoring at the Fermilab Tevatron and Main Injector
Authors:
A. Baumbaugh,
C. Briegel,
B. C. Brown,
D. Capista,
C. Drennan,
B. Fellenz,
K. Knickerbocker,
J. D. Lewis,
A. Marchionni,
C. Needles,
M. Olson,
S. Pordes,
Z. Shi,
D. Still,
R. Thurman-Keup,
M. Utes,
J. Wu
Abstract:
A VME-based data acquisition system for beam-loss monitors has been developed and is in use in the Tevatron and Main Injector accelerators at the Fermilab complex. The need for enhanced beam-loss protection when the Tevatron is operating in collider-mode was the main driving force for the new design. Prior to the implementation of the present system, the beam-loss monitor system was disabled durin…
▽ More
A VME-based data acquisition system for beam-loss monitors has been developed and is in use in the Tevatron and Main Injector accelerators at the Fermilab complex. The need for enhanced beam-loss protection when the Tevatron is operating in collider-mode was the main driving force for the new design. Prior to the implementation of the present system, the beam-loss monitor system was disabled during collider operation and protection of the Tevatron magnets relied on the quench protection system. The new Beam-Loss Monitor system allows appropriate abort logic and thresholds to be set over the full set of collider operating conditions. The system also records a history of beam-loss data prior to a beam-abort event for post-abort analysis. Installation of the Main Injector system occurred in the fall of 2006 and the Tevatron system in the summer of 2007. Both systems were fully operation by the summer of 2008. In this paper we report on the overall system design, provide a description of its normal operation, and show a number of examples of its use in both the Main Injector and Tevatron.
△ Less
Submitted 30 November, 2011;
originally announced November 2011.
-
Operational aspects of the Main Injector large aperture quadrupole (WQB)
Authors:
W. Chou,
L. Bartelson,
B. Brown,
D. Capista,
J. Crisp,
J. DiMarco,
J. Fitzgerald,
H. Glass,
D. Harding,
D. Johnson,
V. Kashikhin,
I. Kourbanis,
P. Prieto,
W. Robotham,
T. Sager,
M. Tartaglia,
L. Valerio,
R. Webber,
M. Wendt,
D. Wolff,
M. Yang
Abstract:
A two-year Large Aperture Quadrupole (WQB) Project was completed in the summer of 2006 at Fermilab. Nine WQBs were designed, fabricated and bench-tested by the Technical Division. Seven of them were installed in the Main Injector and the other two for spares. They perform well. The aperture increase meets the design goal and the perturbation to the lattice is minimal. The machine acceptance in t…
▽ More
A two-year Large Aperture Quadrupole (WQB) Project was completed in the summer of 2006 at Fermilab. Nine WQBs were designed, fabricated and bench-tested by the Technical Division. Seven of them were installed in the Main Injector and the other two for spares. They perform well. The aperture increase meets the design goal and the perturbation to the lattice is minimal. The machine acceptance in the injection and extraction regions is increased from 40pi to 60pi mm-mrad. This paper gives a brief report of the operation and performance of these magnets.
△ Less
Submitted 26 February, 2008;
originally announced February 2008.
-
Fast beam stacking using RF barriers
Authors:
W. Chou,
D. Capista,
J. Griffin,
K-Y. Ng,
D. Wildman
Abstract:
Two barrier RF systems were fabricated, tested and installed in the Fermilab Main Injector. Each can provide 8 kV rectangular pulses (the RF barriers) at 90 kHz. When a stationary barrier is combined with a moving barrier, injected beams from the Booster can be continuously deflected, folded and stacked in the Main Injector, which leads to doubling of the beam intensity. This paper gives a repor…
▽ More
Two barrier RF systems were fabricated, tested and installed in the Fermilab Main Injector. Each can provide 8 kV rectangular pulses (the RF barriers) at 90 kHz. When a stationary barrier is combined with a moving barrier, injected beams from the Booster can be continuously deflected, folded and stacked in the Main Injector, which leads to doubling of the beam intensity. This paper gives a report on the beam experiment using this novel technology.
△ Less
Submitted 26 February, 2008;
originally announced February 2008.