  1. arXiv:2007.05837  [pdf

    physics.app-ph cond-mat.mes-hall

    Field emission from two-dimensional GeAs

    Authors: Antonio Di Bartolomeo, Alessandro Grillo, Filippo Giubileo, Luca Camilli, Jianbo Sun, Daniele Capista, Maurizio Passacantando

    Abstract: GeAs is a layered material of the IV-V groups that is attracting growing attention for possible applications in electronic and optoelectronic devices. In this study, exfoliated multilayer GeAs nanoflakes are structurally characterized and used as the channel of back-gate field-effect transistors. It is shown that their gate-modulated p-type conduction is decreased by exposure to light or electron… ▽ More

    Submitted 11 July, 2020; originally announced July 2020.

    Comments: 10 pages, 3 figures

    Report number: 2021 J. Phys. D: Appl. Phys. 54 105302

    Journal ref: Journal of Physics D: Applied Physics 2021, 54 105302

  2. arXiv:1702.05159  [pdf

    physics.acc-ph

    Beam Extraction From The Recycler Ring To P1 Line At Fermilab

    Authors: M. Xiao, D. Capista, P. Adams, D. Morris, M. J. Yang, K. Hazewood

    Abstract: The transfer line for beam extraction from the Recycler ring to P1 line provides a way to deliver 8 GeV kinetic energy protons from the Booster to the Delivery ring, via the Recycler, using existing beam transport lines, and without the need for new civil construction. It was designed in 2012. The kicker magnets at RR520 and the lambertson magnet at RR522 in the RR were installed in 2014 Summer Sh… ▽ More

    Submitted 16 February, 2017; originally announced February 2017.

    Comments: 3 pp

    Report number: Fermilab-Conf-16-417-AD

  3. arXiv:1601.05037  [pdf, other

    hep-ex physics.ins-det

    First measurement of muon-neutrino disappearance in NOvA

    Authors: P. Adamson, C. Ader, M. Andrews, N. Anfimov, I. Anghel, K. Arms, E. Arrieta-Diaz, A. Aurisano, D. Ayres, C. Backhouse, M. Baird, B. A. Bambah, K. Bays, R. Bernstein, M. Betancourt, V. Bhatnagar, B. Bhuyan, J. Bian, K. Biery, T. Blackburn, V. Bocean, D. Bogert, A. Bolshakova, M. Bowden, C. Bower , et al. (235 additional authors not shown)

    Abstract: This paper reports the first measurement using the NOvA detectors of $ν_μ$ disappearance in a $ν_μ$ beam. The analysis uses a 14 kton-equivalent exposure of $2.74 \times 10^{20}$ protons-on-target from the Fermilab NuMI beam. Assuming the normal neutrino mass hierarchy, we measure $Δm^{2}_{32}=(2.52^{+0.20}_{-0.18})\times 10^{-3}$ eV$^{2}$ and $\sin^2θ_{23}$ in the range 0.38-0.65, both at the 68%… ▽ More

    Submitted 20 January, 2016; v1 submitted 19 January, 2016; originally announced January 2016.

    Comments: 8 pages, 6 figures. Submitted to Phys. Rev. D Rapid Communications

    Journal ref: Phys. Rev. D 93 051104 2016

  4. arXiv:1601.05022  [pdf, other

    hep-ex physics.ins-det

    First measurement of electron neutrino appearance in NOvA

    Authors: P. Adamson, C. Ader, M. Andrews, N. Anfimov, I. Anghel, K. Arms, E. Arrieta-Diaz, A. Aurisano, D. S. Ayres, C. Backhouse, M. Baird, B. A. Bambah, K. Bays, R. Bernstein, M. Betancourt, V. Bhatnagar, B. Bhuyan, J. Bian, K. Biery, T. Blackburn, V. Bocean, D. Bogert, A. Bolshakova, M. Bowden, C. Bower , et al. (235 additional authors not shown)

    Abstract: We report results from the first search for $ν_μ\toν_e$ transitions by the NOvA experiment. In an exposure equivalent to $2.74\times10^{20}$ protons-on-target in the upgraded NuMI beam at Fermilab, we observe 6 events in the Far Detector, compared to a background expectation of $0.99\pm0.11$ (syst.) events based on the Near Detector measurement. A secondary analysis observes 11 events with a backg… ▽ More

    Submitted 2 May, 2016; v1 submitted 19 January, 2016; originally announced January 2016.

    Comments: 7 pages, 4 figures. Minor updates to match version accepted by journal

    Report number: FERMILAB-PUB-15-262-ND

    Journal ref: Phys. Rev. Lett. 116, 151806 (2016)

  5. The Fermilab Main Injector: high intensity operation and beam loss control

    Authors: Bruce C. Brown, Philip Adamson, David Capista, Weiren Chou, Ioanis Kourbanis, Denton K Morris, Kiyomi Seiya, Guan Hong Wu, Ming-Jen Yang

    Abstract: From 2005 through 2012, the Fermilab Main Injector provided intense beams of 120 GeV protons to produce neutrino beams and antiprotons. Hardware improvements in conjunction with improved diagnostics allowed the system to reach sustained operation at ~400 kW beam power. Transmission was very high except for beam lost at or near the 8 GeV injection energy where 95% beam transmission results in about… ▽ More

    Submitted 10 July, 2013; originally announced July 2013.

    Report number: FERMILAB-PUB-12-640-AD

    Journal ref: Phys. Rev. ST Accel. Beams 16, 071001 (2013)

  6. arXiv:1301.7442  [pdf

    physics.acc-ph

    6 Batch Injection and Slipped Beam Tune Measurements in Fermilab's Main Injector

    Authors: D. J. Scott, D. Capista, I. Kourbanis, K. Seiya, M. -J. Yan

    Abstract: During Nova operations it is planned to run the Fermilab Recycler in a 12 batch slip stacking mode. In preparation for this, measurements of the tune during a six batch injection and then as the beam is slipped by changing the RF frequency, but without a 7th injection, have been carried out in the Main Injector. The coherent tune shifts due to the changing beam intensity were measured and compared… ▽ More

    Submitted 30 January, 2013; originally announced January 2013.

    Comments: 3 pp. 3rd International Particle Accelerator Conference (IPAC 2012) 20-25 May 2012, New Orleans, Louisiana

    Report number: FERMILAB-CONF-12-179-AD

  7. arXiv:1301.7439  [pdf

    physics.acc-ph

    Coalescing at 8 GeV in the Fermilab Main Injector

    Authors: D. J. Scott, D. Capista, B. Chase, J. Dye, I. Kourbanis, K. Seiya, M. -J. Yang

    Abstract: For Project X, it is planned to inject a beam of 3 10**11 particles per bunch into the Main Injector. To prepare for this by studying the effects of higher intensity bunches in the Main Injector it is necessary to perform coalescing at 8 GeV. The results of a series of experiments and simulations of 8 GeV coalescing are presented. To increase the coalescing efficiency adiabatic reduction of the 53… ▽ More

    Submitted 30 January, 2013; originally announced January 2013.

    Comments: 3 pp. 3rd International Particle Accelerator Conference (IPAC 2012) 20-25 May 2012, New Orleans, Louisiana

    Report number: FERMILAB-CONF-12-197-AD

  8. arXiv:1301.6993  [pdf

    physics.acc-ph

    Single/Few Bunch Space Charge Effects at 8-GeV in the Fermilab Main Injector

    Authors: D. J. Scott, D. Capista, I. Kourbanis, K. Seiya, M. -J. Yang

    Abstract: For Project X, it is planned to inject a beam of 3x10**11 particles per bunch into the Main Injector. Therefore, at 8-GeV, there will be increased space charge tune shifts and an increased incoherent tune spread. In preparation for these higher intensity bunches exploratory studies have commenced looking at the transmission of different intensity bunches at different tunes. An experiment is descri… ▽ More

    Submitted 29 January, 2013; originally announced January 2013.

    Comments: 3 pp. 3rd International Particle Accelerator Conference (IPAC 2012) 20-25 May 2012, New Orleans, Louisiana

    Report number: FERMILAB-CONF-12-198-AD

  9. arXiv:1301.6989  [pdf

    physics.acc-ph

    Secondary Electron Yield Measurements of Fermilab's Main Injector Vacuum Vessel

    Authors: D. J. Scott, D. Capista, K. L. Duel, R. M. Zwaska, S. Greenwald, W. Hartung, Y. Li, T. P. Moore, M. A. Palmer, R. Kirby, M. Pivi, L. Wang

    Abstract: We discuss the progress made on a new installation in Fermilab's Main Injector that will help investigate the electron cloud phenomenon by making direct measurements of the secondary electron yield (SEY) of samples irradiated in the accelerator. In the Project X upgrade the Main Injector will have its beam intensity increased by a factor of three compared to current operations. This may result in… ▽ More

    Submitted 29 January, 2013; originally announced January 2013.

    Comments: 3 pp. 3rd International Particle Accelerator Conference (IPAC 2012) 20-25 May 2012, New Orleans, Louisiana

    Report number: FERMILAB-CONF-12-196-AD

  10. arXiv:1209.1326  [pdf

    physics.acc-ph

    Operational use of ionization profile monitors in the Fermilab Main Injector

    Authors: Denton K. Morris, Philip Adamson, David Capista, Ioanis Kourbanis, Thomas Meyer, Kiyomi Seiya, David Slimmer, Ming-Jen Yang, James Zagel

    Abstract: Ionization profile monitors (IPMs) are used in the Fermilab Main Injector (MI) to monitor injection lattice matching by measuring turn-by-turn sigmas at injection and to measure transverse emittance of the beam during the acceleration cycle. The IPMs provide a periodic, non-destructive means of performing turn-by-turn emittance measurements where other techniques are not applicable. As Fermilab is… ▽ More

    Submitted 6 September, 2012; originally announced September 2012.

    Comments: 3 pp. Particle Accelerator, 24th Conference (PAC'11) 2011. 28 Mar - 1 Apr 2011. New York, USA

    Report number: FERMILAB-CONF-11-010-AD

  11. arXiv:1208.3414  [pdf

    physics.acc-ph

    A gap clearing kicker for Main Injector

    Authors: I. Kourbanis, P. Adamson, J. Biggs, B. Brown, D. Capista, C. C. Jensen, G. E. Krafczyk, D. K. Morris, D. Scott, K. Seiya, S. R. Ward, G. Wu, M. -J. Yang

    Abstract: Fermilab Main Injector has been operating at high Beam Power levels since 2008 when multi-batch slip stacking became operational. In order to maintain and increase the beam power levels the localized beam loss due to beam left over in the injection kicker gap during slip stacking needs to be addressed. A set of gap clearing kickers that kick any beam left in the injection gap to the beam abort hav… ▽ More

    Submitted 16 August, 2012; originally announced August 2012.

    Comments: 3 pp. Particle Accelerator, 24th Conference (PAC'11) 2011. 28 Mar - 1 Apr 2011. New York, USA

    Report number: FERMILAB-CONF-11-085-AD

  12. Demonstration of Communication using Neutrinos

    Authors: D. D. Stancil, P. Adamson, M. Alania, L. Aliaga, M. Andrews, C. Araujo Del Castillo, L. Bagby, J. L. Bazo Alba, A. Bodek, D. Boehnlein, R. Bradford, W. K. Brooks, H. Budd, A. Butkevich, D. A. M. Caicedo, D. P. Capista, C. M. Castromonte, A. Chamorro, E. Charlton, M. E. Christy, J. Chvojka, P. D. Conrow, I. Danko, M. Day, J. Devan , et al. (87 additional authors not shown)

    Abstract: Beams of neutrinos have been proposed as a vehicle for communications under unusual circumstances, such as direct point-to-point global communication, communication with submarines, secure communications and interstellar communication. We report on the performance of a low-rate communications link established using the NuMI beam line and the MINERvA detector at Fermilab. The link achieved a decode… ▽ More

    Submitted 9 April, 2012; v1 submitted 13 March, 2012; originally announced March 2012.

    Comments: 10 pages, 7 figures, updated with final figures used in Modern Physics Letters A publication

    Report number: FNAL PUB-12-073-E

    Journal ref: Mod. Phys. Lett. A 27 (2012) 1250077

  13. arXiv:1111.7229  [pdf

    physics.ins-det physics.acc-ph

    The upgraded data acquisition system for beam loss monitoring at the Fermilab Tevatron and Main Injector

    Authors: A. Baumbaugh, C. Briegel, B. C. Brown, D. Capista, C. Drennan, B. Fellenz, K. Knickerbocker, J. D. Lewis, A. Marchionni, C. Needles, M. Olson, S. Pordes, Z. Shi, D. Still, R. Thurman-Keup, M. Utes, J. Wu

    Abstract: A VME-based data acquisition system for beam-loss monitors has been developed and is in use in the Tevatron and Main Injector accelerators at the Fermilab complex. The need for enhanced beam-loss protection when the Tevatron is operating in collider-mode was the main driving force for the new design. Prior to the implementation of the present system, the beam-loss monitor system was disabled durin… ▽ More

    Submitted 30 November, 2011; originally announced November 2011.

    Comments: 24 pages

    Report number: FERMILAB-PUB-11-618-AD-PPD

    Journal ref: 2011 JINST 6 T11006

  14. arXiv:0802.3911  [pdf

    physics.acc-ph

    Operational aspects of the Main Injector large aperture quadrupole (WQB)

    Authors: W. Chou, L. Bartelson, B. Brown, D. Capista, J. Crisp, J. DiMarco, J. Fitzgerald, H. Glass, D. Harding, D. Johnson, V. Kashikhin, I. Kourbanis, P. Prieto, W. Robotham, T. Sager, M. Tartaglia, L. Valerio, R. Webber, M. Wendt, D. Wolff, M. Yang

    Abstract: A two-year Large Aperture Quadrupole (WQB) Project was completed in the summer of 2006 at Fermilab. Nine WQBs were designed, fabricated and bench-tested by the Technical Division. Seven of them were installed in the Main Injector and the other two for spares. They perform well. The aperture increase meets the design goal and the perturbation to the lattice is minimal. The machine acceptance in t… ▽ More

    Submitted 26 February, 2008; originally announced February 2008.

    Comments: 2007 Particle Accelerator Conference (PAC07)

    Report number: FERMILAB-CONF-07-344-AD

    Journal ref: Conf.Proc.C070625:1685,2007

  15. arXiv:0802.3907  [pdf

    physics.acc-ph physics.ins-det

    Fast beam stacking using RF barriers

    Authors: W. Chou, D. Capista, J. Griffin, K-Y. Ng, D. Wildman

    Abstract: Two barrier RF systems were fabricated, tested and installed in the Fermilab Main Injector. Each can provide 8 kV rectangular pulses (the RF barriers) at 90 kHz. When a stationary barrier is combined with a moving barrier, injected beams from the Booster can be continuously deflected, folded and stacked in the Main Injector, which leads to doubling of the beam intensity. This paper gives a repor… ▽ More

    Submitted 26 February, 2008; originally announced February 2008.

    Comments: 2007 Particle Accelerator Conference (PAC07)

    Report number: FERMILAB-CONF-07-347-AD