Skip to main content

Showing 1–13 of 13 results for author: Camillocci, E S

.
  1. Use of bremsstrahlung radiation to identify hidden weak beta- sources: feasibility and possible use in radio-guided surgery

    Authors: D. Carlotti, F. Collamatii, R. Faccinii, P. Freschi, F. Iacoangelii, Mancini-Terraccianoi, M. Marafinii, R. Mirabellii, L. Recchiai, A. Russomandoi, E. Solfaroli Camillocci i, M. Toppii, G. Trainii, V. Bocci

    Abstract: The recent interest in beta- radionuclides for radio-guided surgery derives from the feature of the beta radiation to release energy in few millimeters of tissue. Such feature can be used to locate residual tumors with a probe located in its immediate vicinity, determining the resection margins with an accuracy of millimeters. The drawback of this technique is that it does not allow to identify tu… ▽ More

    Submitted 24 October, 2017; originally announced October 2017.

  2. arXiv:1610.09246  [pdf, other

    physics.ins-det physics.med-ph

    Feasibility of the $β^-$ Radio-Guided Surgery with a Variety of Radio-Nuclides of Interest to Nuclear Medicine

    Authors: Carlo Mancini-Terracciano, Raffaella Donnarumma, Gaia Bencivenga, Valerio Bocci, Antonella Cartoni, Francesco Collamati, Ilaria Fratoddi, Alessandro Giordano, Luca Indovina, Michela Marafini, Silvio Morganti, Dante Rotili, Andrea Russomando, Teresa Scotognella, Elena Solfaroli Camillocci, Marco Toppi, Giacomo Traini, Iole Venditti, Riccardo Faccini

    Abstract: The $β^-$ based radio-guided surgery overcomes the corresponding $γ$ technique in case the background from healthy tissues is relevant. It can be used only in case a radio-tracer marked with $^{90}$Y is available since the current probe prototype was optimized for the emission spectrum of this radio-nuclide. Here we study, with a set of laboratory tests and simulations, the prototype capability in… ▽ More

    Submitted 28 October, 2016; originally announced October 2016.

    Comments: 14 pages, 5 Figs

  3. arXiv:1608.08364  [pdf, other

    physics.ins-det physics.med-ph

    First Ex-Vivo Validation of a Radioguided Surgery Technique with beta- Radiation

    Authors: E. Solfaroli Camillocci, M. Schiariti, V. Bocci, A. Carollo, G. Chiodi, M. Colandrea, F. Collamati, M. Cremonesi, R. Donnarumma, M. E. Ferrari, P. Ferroli, F. Ghielmetti, C. M. Grana, M. Marafini, S. Morganti, C. Mancini Terracciano, M. Patanè, G. Pedroli, B. Pollo, L. Recchia, A. Russomando, M. Toppi, G. Traini, R. Faccini

    Abstract: Purpose: A radio-guided surgery technique with beta- -emitting radio-tracers was suggested to overcome the effect of the large penetration of gamma radiation. The feasibility studies in the case of brain tumors and abdominal neuro-endocrine tumors were based on simulations starting from PET images with several underlying assumptions. This paper reports, as proof-of-principle of this technique, an… ▽ More

    Submitted 30 August, 2016; originally announced August 2016.

    Comments: 17 pages, 4 Figs, Accepted by Physica Medica

    Journal ref: Phys. Med. 32(9) 1139 (2016)

  4. Secondary radiation measurements for particle therapy applications: nuclear fragmentation produced by $^4$He ion beams in a PMMA target

    Authors: M. Marafini, R. Paramatti, D. Pinci, G. Battistoni, F. Collamati, E. De Lucia, R. Faccini, P. M. Frallicciardi, C. Mancini-Terracciano, I. Mattei, S. Muraro, L. Piersanti, M. Rovituso, A. Rucinski, A. Russomando, A. Sarti, A. Sciubba, E. Solfaroli Camillocci, M. Toppi, G. Traini, C. Voena, V. Patera

    Abstract: Nowadays there is a growing interest in Particle Therapy treatments exploiting light ion beams against tumors due to their enhanced Relative Biological Effectiveness and high space selectivity. In particular promising results are obtained by the use of $^4$He projectiles. Unlike the treatments performed using protons, the beam ions can undergo a fragmentation process when interacting with the atom… ▽ More

    Submitted 29 August, 2016; originally announced August 2016.

  5. arXiv:1608.04624  [pdf, other

    physics.med-ph

    Secondary radiation measurements for particle therapy applications: Charged secondaries produced by 4He and 12C ion beams in a PMMA target at large angle

    Authors: A. Rucinski, E. De Lucia, G. Battistoni, F. Collamati, R. Faccini, P. M. Frallicciardi, C. Mancini-Terracciano, M. Marafini, I. Mattei, S. Muraro, R. Paramatti, L. Piersanti, D. Pinci, A. Russomando, A. Sarti, A. Sciubba, E. Solfaroli Camillocci, M. Toppi, G. Traini, C. Voena, V. Patera

    Abstract: Measurements performed with the purpose of characterizing the charged secondary radiation for dose release monitoring in particle therapy are reported. Charged secondary yields, energy spectra and emission profiles produced in poly-methyl methacrylate (PMMA) target by 4He and 12C beams of different therapeutic energies were measured at 60 and 90 degree with respect to the primary beam direction. T… ▽ More

    Submitted 16 August, 2016; originally announced August 2016.

    Comments: 19 pages, 26 Figures

  6. arXiv:1605.08377  [pdf, other

    physics.med-ph physics.ins-det

    Secondary radiation measurements for particle therapy applications: prompt photons produced by $^{4}$He, $^{12}$C and $^{16}$O ion beams in a PMMA target

    Authors: Ilaria Mattei, Francesco Collamati, Erika De Lucia, Riccardo Faccini, Paola Maria Frallicciardi, Carlo Mancini-Terracciano, Michela Marafini, Silvia Muraro, Riccardo Paramatti, Vincenzo Patera, Luca Piersanti, Davide Pinci, Antoni Rucinski, Andrea Russomando, Alessio Sarti, Adalberto Sciubba, Elena Solfaroli Camillocci, Marco Toppi, Giacomo Traini, Cecilia Voena, Giuseppe Battistoni

    Abstract: Charged particle beams are used in Particle Therapy (PT) to treat oncological patients due to their selective dose deposition in tissues and to their high biological effect in killing cancer cells with respect to photons and electrons used in conventional radiotherapy. Nowadays, protons and carbon ions are used in PT clinical routine but, recently, the interest on the potential application of heli… ▽ More

    Submitted 19 July, 2016; v1 submitted 26 May, 2016; originally announced May 2016.

    Comments: Submitted to PMB

  7. Polycrystalline para-terphenyl scintillator adopted in a $β^-$ detecting probe for radio-guided surgery

    Authors: Elena Solfaroli Camillocci, Fabio Bellini, Valerio Bocci, Francesco Collamati, Erika De Lucia, Riccardo Faccini, Michela Marafini, Ilaria Mattei, Silvio Morganti, Riccardo Paramatti, Vincenzo Patera, Davide Pinci, Luigi Recchia, Andrea Russomando, Alessio Sarti, Adalberto Sciubba, Martina Senzacqua, Cecilia Voena

    Abstract: A radio-guided surgery technique exploiting $β^-$ emitters is under development. It aims at a higher target-to-background activity ratio implying both a smaller radiopharmaceutical activity and the possibility of extending the technique to cases with a large uptake of surrounding healthy organs. Such technique requires a dedicated intraoperative probe detecting $β^-$ radiation. A first prototype h… ▽ More

    Submitted 9 November, 2015; originally announced November 2015.

    Comments: Presented at conference: Applications of Novel Scintillators for Research and Industry (ANSRI 2015)

    Journal ref: Journal of Physics: Conference Series 620 (2015) 012009

  8. arXiv:1511.02059  [pdf, other

    physics.med-ph physics.ins-det

    An Intraoperative $β^-$ Detecting Probe For Radio-Guided Surgery in Tumour Resection

    Authors: Andrea Russomando, Fabio Bellini, Valerio Bocci, Giacomo Chiodi, Francesco Collamati, Erika De Lucia, Raffaella Donnarumma, Riccardo Faccini, Carlo Mancini Terracciano, Michela Marafini, Riccardo Paramatti, Vincenzo Patera, %Davide Pinci, Luigi Recchia, Alessio Sarti, Adalberto Sciubba, Elena Solfaroli Camillocci, Cecilia Voena, Silvio Morganti

    Abstract: The development of the $β^-$ based radio-guided surgery aims to extend the technique to those tumours where surgery is the only possible treatment and the assessment of the resection would most profit from the low background around the lesion, as for brain tumours. Feasibility studies on meningioma, glioma, and neuroendocrine tumors already estimated the potentiality of this new treatment. To vali… ▽ More

    Submitted 6 November, 2015; originally announced November 2015.

    Comments: 7 pages, 15 figures

  9. arXiv:1412.7389  [pdf, other

    physics.med-ph physics.ins-det q-bio.TO

    Towards a Radio-guided Surgery with $β^{-}$ Decays: Uptake of a somatostatin analogue (DOTATOC) in Meningioma and High Grade Glioma

    Authors: Francesco Collamati, Alessandra Pepe, Fabio Bellini, Valerio Bocci, Marta Cremonesi, Erika De Lucia, Mahila Ferrari, Paola M. Frallicciardi, Chiara M. Grana, Michela Marafini, Ilaria Mattei, Silvio Morganti, Vincenzo Patera, Luca Piersanti, Luigi Recchia, Andrea Russomando, Alessio Sarti, Adalberto Sciubba, Martina Senzacqua, Elena Solfaroli Camillocci, Cecilia Voena, Riccardo Faccini

    Abstract: A novel radio guided surgery (RGS) technique for cerebral tumors using $β^{-}$ radiation is being developed. Checking the availability of a radio-tracer that can deliver a $β^{-}$ emitter to the tumor is a fundamental step in the deployment of such technique. This paper reports a study of the uptake of 90Y labeled (DOTATOC) in the meningioma and the high grade glioma (HGG) and a feasibility study… ▽ More

    Submitted 23 December, 2014; originally announced December 2014.

    Comments: 21 pages, 5 figures

    Journal ref: J Nucl Med 2015 56:8A

  10. arXiv:1402.2248  [pdf, other

    physics.med-ph physics.ins-det

    A novel radioguided surgery technique exploiting $β^{-}$ decays

    Authors: E. Solfaroli Camillocci, G. Baroni, F. Bellini, V. Bocci, F. Collamati, M. Cremonesi, E. De Lucia, P. Ferroli, S. Fiore, C. M. Grana, M. Marafini, I. Mattei, S. Morganti, G. Paganelli, V. Patera, L. Piersanti, L. Recchia, A. Russomando, M. Schiariti, A. Sarti, A. Sciubba, C. Voena, R. Faccini

    Abstract: The background induced by the high penetration power of the gamma radiation is the main limiting factor of the current Radio-guided surgery (RGS). To partially mitigate it, a RGS with beta+ emitting radio-tracers has been suggested in literature. Here we propose the use of beta- emitting radio-tracers and beta- probes and discuss the advantage of this method with respect to the previously explor… ▽ More

    Submitted 10 February, 2014; originally announced February 2014.

    Comments: 14 pages, 7 figures

    Journal ref: Sci. Rep. 4, 4401 (2014)

  11. arXiv:1307.5689  [pdf, other

    physics.med-ph physics.ins-det

    Extended calibration range for prompt photon emission in ion beam irradiation

    Authors: F. Bellini, T. T. Boehlen, M. P. W. Chin, F. Collamati, E. De Lucia, R. Faccini, A. Ferrari, L. Lanza, C. Mancini-Terraciano, M. Marafini, I. Mattei, S. Morganti, P. G. Ortega, V. Patera, L. Piersanti, A. Russomando, P. R. Sala, A. Sarti, A. Sciubba, E. Solfaroli Camillocci, C. Voena

    Abstract: Monitoring the dose delivered during proton and carbon ion therapy is still a matter of research. Among the possible solutions, several exploit the measurement of the single photon emission from nuclear decays induced by the irradiation. To fully characterize such emission the detectors need development, since the energy spectrum spans the range above the MeV that is not traditionally used in medi… ▽ More

    Submitted 22 July, 2013; originally announced July 2013.

    Comments: 4 pages, 7 figures, Submitted to JINST

    Journal ref: Nuclear Inst. and Methods in Physics Research, A 745C (2014), pp. 114-118

  12. arXiv:1305.0442  [pdf, other

    physics.ins-det physics.med-ph

    Properties of para-terphenyl as detector for alpha, beta and gamma radiation

    Authors: M. Angelone, G. Battistoni, F. Bellini, V. Bocci, F. Collamati, E. De Lucia, R. Faccini, F. Ferroni, S. Fiore, M. Marafini, D. Materazzo, I. Mattei, S. Morganti, V. Patera, L. Piersanti, M. Pillon, L. Recchia, A. Russomando, A. Sarti, A. Sciubba, E. Solfaroli Camillocci, C. Voena

    Abstract: Organic scintillators are often chosen as radiation detectors for their fast decay time and their low Z, while inorganic ones are used when high light ields are required. In this paper we show that a para-terphenyl based detector has a blend of properties of the two categories that can be optimal for energy and position measurements of low energy charged particles. On 0.1% diphenylbutadiene doped… ▽ More

    Submitted 2 May, 2013; originally announced May 2013.

    Comments: 5 pages, 6 figures

  13. arXiv:0901.0512  [pdf

    hep-ex

    Expected Performance of the ATLAS Experiment - Detector, Trigger and Physics

    Authors: The ATLAS Collaboration, G. Aad, E. Abat, B. Abbott, J. Abdallah, A. A. Abdelalim, A. Abdesselam, O. Abdinov, B. Abi, M. Abolins, H. Abramowicz, B. S. Acharya, D. L. Adams, T. N. Addy, C. Adorisio, P. Adragna, T. Adye, J. A. Aguilar-Saavedra, M. Aharrouche, S. P. Ahlen, F. Ahles, A. Ahmad, H. Ahmed, G. Aielli, T. Akdogan , et al. (2587 additional authors not shown)

    Abstract: A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on… ▽ More

    Submitted 14 August, 2009; v1 submitted 28 December, 2008; originally announced January 2009.