Skip to main content

Showing 1–7 of 7 results for author: Camelia, E A

.
  1. arXiv:2006.00331  [pdf, other

    physics.ins-det

    Characterization of new eco friendly gas mixtures based on HFO for RPCs

    Authors: G. Proto, G. Aielli, E. Alunno Camelia, P. Camarri, R. Cardarelli, A. Di Ciaccio, L. Di Stante, B. Liberti, A. Paoloni, E. Pastori, L. Pizzimento, A. Rocchi, R. Santonico, E. Tusi

    Abstract: The ATLAS RPC standard mixture, mainly based on C$_{2}$H$_{2}$F$_{4}$, has a high Global Warming Potential (GWP) and therefore the search for RPC eco friendly gases is mandatory. In this work we present the results on the detector performances in terms of efficiency, prompt and ionic charge, with different gas mixtures.

    Submitted 30 May, 2020; originally announced June 2020.

  2. arXiv:2006.00306  [pdf, other

    physics.ins-det hep-ex

    Linearity and rate capability measurements of RPC with semi-insulating crystalline electrodes operating in avalanche mode

    Authors: A. Rocchi, R. Cardarelli, B. Liberti, G. Aielli, E. Alunno Camelia, P. Camarri, M. Cirillo, A. Di Ciaccio, L. Di Stante, M. Lucci, E. Pastori, L. Pizzimento, G. Proto, E. Tusi, R. Santonico

    Abstract: The intrinsic rate capability and the ageing properties of the Resistive Plate Chambers are closely related to the electrodes material and to the front-end electronics threshold. The development of a low noise pre-amplifier led us to improve the intrinsic rate capability of High Pressure Laminate (bakelite) up to $\sim10\;kHz/cm^2$, nevertheless the effective rate is significantly limited by elect… ▽ More

    Submitted 30 May, 2020; originally announced June 2020.

    Comments: 6 pages, 7 figures

  3. arXiv:1809.10497  [pdf, other

    physics.ins-det hep-ex

    RPC performance vs FE electoronics and detector parameters

    Authors: R. Cardarelli, G. Aielli, E. Alunno Camelia, S. Bruno, A. Caltabiano, P. Camarri, A. Di Ciaccio, B. Liberti, L. Massa, L. Pizzimento, A. Rocchi

    Abstract: The first Resistive Plate Chambers detectors were developed for cosmic ray experiments, where low rate capability, good time resolution and low cost per unit of area were needed. These same features, except for the low rate capability, were required in the muon spectrometers of the collider experiments like LHC. For this purpose newRPCdetectors with increased rate capability were developed. The ra… ▽ More

    Submitted 27 September, 2018; originally announced September 2018.

  4. Development of gaseous particle detectors based on semiconductive plate electrodes

    Authors: A. Rocchi, R. Cardarelli, G. Aielli, E. Alunno Camelia, S. Bruno, A. Caltabiano, P. Camarri, A. Di Ciaccio, B. Liberti, L. Massa, L. Pizzimento

    Abstract: A new particle detector with sub-nanosecond time resolution capable of working in high-rate environment (rate capability of the order of $MHz/ cm^2$) is under developmnet. Semiconductive electrodes with resistivity $ρ$ up to $10^8 Ω\cdot cm$ have been used to improve the RPC [1] [2] rate capability. In this paper efficiency and time resolution of three different detector structures are presented.

    Submitted 5 July, 2018; originally announced July 2018.

  5. Development of a new Front End electronics in Silicon and Silicon-Germanium technology for the Resistive Plate Chamber detector for high rate experiments

    Authors: Luca Pizzimento, Roberto Cardarelli, Giulio Aielli, Elio Alunno Camelia, Salvatore Bruno, Alessandro Caltabiano, Paolo Camarri, Anna Di Ciaccio, Barbara Liberti, Lorenzo Massa, Alessandro Rocchi

    Abstract: The upgrade of the Resistive Plate Chamber (RPC) detector, in order to increase the detector rate capability and to be able to work efficiently in high rate environment, consists in the reduction of the operating voltage along with the detection of signals which are few hundred μV small. The approach chosen by this project to achieve this objective is to develop a new kind of Front End electronics… ▽ More

    Submitted 11 June, 2018; originally announced June 2018.

    Comments: 14th Workshop on Resistive Plate Chambers and Related Detectors 19-23 February, 2018 Puerto Vallarta, Jalisco state, Mexico

    Journal ref: Journal of Instrumentation, Volume 14, October 2019

  6. arXiv:1806.04082  [pdf, other

    physics.ins-det

    Design a TDC in SiGe for RPC's electronics Front-end for the use in a high-rate experiment

    Authors: Salvatore Bruno, Roberto Cardarelli, Giulio Aielli, davide Badoni, Paolo Camarri, Anna Di Ciaccio, Eelio Alunno Camelia, Alessandro Caltabiano, Lorenzo Massa, Lorenzo Paolozzi, Luca Pizzimento, Alessandro Rocchi

    Abstract: With the new generation of the RPC, it is possible to work with induced signals of hundreds $μV$, hence the front-end electronics is an important and delicate part of the detector in order to get a detectable signal. The electronic chain is made up of an amplifier, a discriminator, a TDC. The new front-end is realized with the use of silicon-germanium (SiGe) components, provided by IHP microelectr… ▽ More

    Submitted 21 June, 2018; v1 submitted 11 June, 2018; originally announced June 2018.

    Comments: 7 pages, 11 figures, RPC conference 2018, JINST 2018

  7. arXiv:1806.04026  [pdf, other

    physics.ins-det nucl-ex

    Optimization of RPCs read-out panel with electromagnetic simulation

    Authors: E. Alunno Camelia, R. Cardarelli, A. Di Ciaccio, S. Bruno, A. Caltabiano, P. Camarri, B. Liberti, L. Massa, L. Pizzimento, A. Rocchi

    Abstract: With the upgrade of the RPCs [1]-[2] and the increase of its performances, the study and the optimization of the read-out panel is necessary in order to maintain the signal integrity and to reduce the intrinsic crosstalk. Through Electromagnetic Simulation, performed with CST Studio Suite, new panels design are tested and their crosstalk property are studied. The behavior of different type of pane… ▽ More

    Submitted 11 June, 2018; originally announced June 2018.