-
Coherently averaged dual-comb spectroscopy with a low-noise and high-power free-running gigahertz dual-comb laser
Authors:
C. R. Phillips,
B. Willenberg,
A. Nussbaum-Lap**,
F. Callegari,
S. L. Camenzind,
J. Pupeikis,
U. Keller
Abstract:
We present a new type of dual optical frequency comb source capable of scaling applications to high measurement speeds while combining high average power, ultra-low noise operation, and a compact setup. Our approach is based on a diode-pumped solid-state laser cavity which includes an intracavity biprism operated at Brewster angle to generate two spatially-separated modes with highly correlated pr…
▽ More
We present a new type of dual optical frequency comb source capable of scaling applications to high measurement speeds while combining high average power, ultra-low noise operation, and a compact setup. Our approach is based on a diode-pumped solid-state laser cavity which includes an intracavity biprism operated at Brewster angle to generate two spatially-separated modes with highly correlated properties. The 15-cm-long cavity uses an Yb:CALGO crystal and a SESAM as an end mirror to generate more than 3 W average power per comb, below 80 fs pulse duration, a repetition rate of 1.03 GHz, and a continuously tunable repetition rate difference up to 27 kHz. We carefully investigate the coherence properties of the dual-comb by a series of heterodyne measurements, revealing several important features: (1) ultra-low jitter on the uncorrelated part of the timing noise; (2) the radio frequency comb lines of the interferograms are fully resolved in free-running operation; (3) we validate that through a simple measurement of the interferograms we can determine the fluctuations of the phase of all the radio frequency comb lines; (4) this phase information is used in a post-processing routine to perform coherently averaged dual-comb spectroscopy of acetylene (C2H2) over long timescales. Our results represent a powerful and general approach to dual-comb applications by combining low noise and high power operation directly from a highly compact laser oscillator.
△ Less
Submitted 17 April, 2023; v1 submitted 27 October, 2022;
originally announced November 2022.
-
A simple way of simulating transmission lines using free software. Application to a quarter wave transformer
Authors:
Fulvio Andres Callegari
Abstract:
A simple way of simulating transmission lines using a free software is presented. In order to validate the results, the effective value of reflection coefficient for voltage wave in a quarter wavelength line was determined trough a transient analysis, for an incident voltage sin-type continuous wave front. The simulations presented reproduced the results previously found analytically.
A simple way of simulating transmission lines using a free software is presented. In order to validate the results, the effective value of reflection coefficient for voltage wave in a quarter wavelength line was determined trough a transient analysis, for an incident voltage sin-type continuous wave front. The simulations presented reproduced the results previously found analytically.
△ Less
Submitted 5 April, 2021;
originally announced April 2021.
-
Thick lenses systems
Authors:
Fulvio Andres Callegari
Abstract:
The optical matrix formalism is applied to find parameters such as focal distance, back and front focal points, principal planes, and the equation relating object and image distances for a thick spherical lens immerse in air. Then, the formalism is applied to systems compound of two, three and N thick lenses in cascade. It is found that a simple Gaussian equation is enough to relate object and ima…
▽ More
The optical matrix formalism is applied to find parameters such as focal distance, back and front focal points, principal planes, and the equation relating object and image distances for a thick spherical lens immerse in air. Then, the formalism is applied to systems compound of two, three and N thick lenses in cascade. It is found that a simple Gaussian equation is enough to relate object and image distances no matter the number of lenses.
△ Less
Submitted 19 August, 2021; v1 submitted 1 April, 2021;
originally announced April 2021.
-
Identifying Treatment Effects using Trimmed Means when Data are Missing Not at Random
Authors:
Alex Ocampo,
Heinz Schmidli,
Peter Quarg,
Francesca Callegari,
Marcello Pagano
Abstract:
Patients often discontinue treatment in a clinical trial because their health condition is not improving. Consequently, the patients still in the study at the end of the trial have better health outcomes on average than the initial patient population would have had if every patient had completed the trial. If we only analyze the patients who complete the trial, then this missing data problem biase…
▽ More
Patients often discontinue treatment in a clinical trial because their health condition is not improving. Consequently, the patients still in the study at the end of the trial have better health outcomes on average than the initial patient population would have had if every patient had completed the trial. If we only analyze the patients who complete the trial, then this missing data problem biases the estimator of a medication's efficacy because study outcomes are missing not at random (MNAR). One way to overcome this problem - the trimmed means approach for missing data - sets missing values as slightly worse than the worst observed outcome and then trims away a fraction of the distribution from each treatment arm before calculating differences in treatment efficacy (Permutt 2017, Pharmaceutical statistics 16.1:20-28). In this paper we derive sufficient and necessary conditions for when this approach can identify the average population treatment effect in the presence of MNAR data. Numerical studies show the trimmed means approach's ability to effectively estimate treatment efficacy when data are MNAR and missingness is strongly associated with an unfavorable outcome, but trimmed means fail when data are missing at random (MAR) when the better approach would be to multiply impute the missing values. If the reasons for discontinuation in a clinical trial are known analysts can improve estimates with a combination of multiple imputation (MI) and the trimmed means approach when the assumptions of each missing data mechanism hold. When the assumptions are justifiable, using trimmed means can help identify treatment effects notwithstanding MNAR data.
△ Less
Submitted 21 November, 2019; v1 submitted 2 August, 2019;
originally announced August 2019.