-
Performance of prototype BTeV silicon pixel detectors in a high energy pion beam
Abstract: The silicon pixel vertex detector is a key element of the BTeV spectrometer. Sensors bump-bonded to prototype front-end devices were tested in a high energy pion beam at Fermilab. The spatial resolution and occupancies as a function of the pion incident angle were measured for various sensor-readout combinations. The data are compared with predictions from our Monte Carlo simulation and very goo… ▽ More
Submitted 8 August, 2001; v1 submitted 7 August, 2001; originally announced August 2001.
Comments: 24 pages, 20 figures
Report number: Fermilab-pub-01/229-e
Journal ref: Nucl.Instrum.Meth.A485:411-425,2002
-
Measuring surface-area-to-volume ratios in soft porous materials using laser-polarized xenon interphase exchange NMR
Abstract: We demonstrate a minimally invasive nuclear magnetic resonance (NMR) technique that enables determination of the surface-area-to-volume ratio (S/V) of soft porous materials from measurements of the diffusive exchange of laser-polarized 129Xe between gas in the pore space and 129Xe dissolved in the solid phase. We apply this NMR technique to porous polymer samples and find approximate agreement w… ▽ More
Submitted 21 August, 2001; originally announced August 2001.
Comments: 14 pages of text, 4 figures
-
Beam Test of BTeV Pixel Detectors
Abstract: The silicon pixel vertex detector is one of the key elements of the BTeV spectrometer. Detector prototypes were tested in a beam at Fermilab. We report here on the measured spatial resolution as a function of the incident angles for different sensor-readout electronics combinations. We compare the results with predictions from our Monte Carlo simulation.
Submitted 21 November, 2000; originally announced November 2000.
Comments: 7 pages, 5 figures, Invited talk given by J.C. Wang at "Vertex 2000, 9th International Workshop on Vertex Detectors", Michigan, Sept 10-15, 2000. To be published in NIM A
Journal ref: Nucl.Instrum.Meth.A473:119-123,2001
-
Beam Test Results of the BTeV Silicon Pixel Detector
Abstract: The results of the BTeV silicon pixel detector beam test carried out at Fermilab in 1999-2000 are reported. The pixel detector spatial resolution has been studied as a function of track inclination, sensor bias, and readout threshold.
Submitted 7 September, 2000; originally announced September 2000.
Comments: 8 pages of text, 8 figures, Proceedings paper of Pixel 2000: International Workshop on Semiconductor Pixel Detectors for Particles and X-Rays, Genova, June 5-8, 2000
Journal ref: Nucl.Instrum.Meth.A465:125-130,2000