Report of the Instrumentation Frontier Working Group for Snowmass 2021
Authors:
Phillip S. Barbeau,
Petra Merkel,
**long Zhang,
Darin Acosta,
Anthony A. Affolder,
Artur Apresyan,
Marina Artuso,
Vallary Bhopatkar,
Stephen Butalla,
Gabriella A. Carini,
Thomas Cecil,
Amy Connolly,
C. Eric Dahl,
Allison Deiana,
Katherine Dunne,
Carlos O. Escobar,
Juan Estrada,
Farah Fahim,
James E. Fast,
Maurice Garcia-Sciveres,
Roxanne Guenette,
Michael T. Hedges,
Kent Irwin,
Albrecht Karle,
Wes Ketchum
, et al. (20 additional authors not shown)
Abstract:
Detector instrumentation is at the heart of scientific discoveries. Cutting edge technologies enable US particle physics to play a leading role worldwide. This report summarizes the current status of instrumentation for High Energy Physics (HEP), the challenges and needs of future experiments and indicates high priority research areas. The Snowmass Instrumentation Frontier studies detector technol…
▽ More
Detector instrumentation is at the heart of scientific discoveries. Cutting edge technologies enable US particle physics to play a leading role worldwide. This report summarizes the current status of instrumentation for High Energy Physics (HEP), the challenges and needs of future experiments and indicates high priority research areas. The Snowmass Instrumentation Frontier studies detector technologies and Research and Development (R&D) needed for future experiments in collider physics, neutrino physics, rare and precision physics and at the cosmic frontier. It is divided into more or less diagonal areas with some overlap among a few of them. We lay out five high-level key messages that are geared towards ensuring the health and competitiveness of the US detector instrumentation community, and thus the entire particle physics landscape.
△ Less
Submitted 3 November, 2022; v1 submitted 28 September, 2022;
originally announced September 2022.
-
Quality Control of Mass-Produced GEM Detectors for the CMS GE1/1 Muon Upgrade
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
T. Beyrouthy,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi
, et al. (157 additional authors not shown)
Abstract:
The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton co…
▽ More
The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton collisions is expected to exceed $2-3\times10^{34}$~cm$^{-2}$s$^{-1}$ for Run 3 (starting in 2022), and it will be at least $5\times10^{34}$~cm$^{-2}$s$^{-1}$ when the High Luminosity Large Hadron Collider is completed for Run 4. These conditions will affect muon triggering, identification, and measurement, which are critical capabilities of the experiment. To address these challenges, additional muon detectors are being installed in the CMS endcaps, based on Gas Electron Multiplier technology. For this purpose, 161 large triple-Gas Electron Multiplier detectors have been constructed and tested. Installation of these devices began in 2019 with the GE1/1 station and will be followed by two additional stations, GE2/1 and ME0, to be installed in 2023 and 2026, respectively. The assembly and quality control of the GE1/1 detectors were distributed across several production sites around the world. We motivate and discuss the quality control procedures that were developed to standardize the performance of the detectors, and we present the final results of the production. Out of 161 detectors produced, 156 detectors passed all tests, and 144 detectors are now installed in the CMS experiment. The various visual inspections, gas tightness tests, intrinsic noise rate characterizations, and effective gas gain and response uniformity tests allowed the project to achieve this high success rate.
△ Less
Submitted 22 March, 2022;
originally announced March 2022.
-
Electronics integration for the GE2/1 and ME0 GEM detector systems for the CMS Phase-2 Muon System Upgrade
Authors:
Stephen D. Butalla,
Marcus Hohlmann
Abstract:
The Large Hadron Collider is currently undergoing its High Luminosity upgrade, which is set to increase the instantaneous luminosity by about a factor of five. Consequently, the Compact Muon Solenoid experiment is upgrading its muon spectrometer to cope with the increased muon flux in the forward region. The GE2/1 triple-Gas Electron Multiplier detector, which has recently entered the mass product…
▽ More
The Large Hadron Collider is currently undergoing its High Luminosity upgrade, which is set to increase the instantaneous luminosity by about a factor of five. Consequently, the Compact Muon Solenoid experiment is upgrading its muon spectrometer to cope with the increased muon flux in the forward region. The GE2/1 triple-Gas Electron Multiplier detector, which has recently entered the mass production phase, and the ME0 triple-GEM detector system, which is in the late prototy** phase, are undergoing electronics integration. These proceedings briefly discuss the frontend electronics for the GE2/1 and ME0 detector systems, the electronics integration testing process, and the future plans for the frontend electronics of these two detector systems by the CMS GEM Collaboration.
△ Less
Submitted 30 October, 2021;
originally announced November 2021.
-
Performance of a Triple-GEM Demonstrator in $pp$ Collisions at the CMS Detector
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi,
O. Bouhali
, et al. (156 additional authors not shown)
Abstract:
After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $η$ region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstr…
▽ More
After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $η$ region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstrator GEM detectors were installed in CMS during 2017 to gain operational experience and perform a preliminary investigation of detector performance. We present the results of triple-GEM detector performance studies performed in situ during normal CMS and LHC operations in 2018. The distribution of cluster size and the efficiency to reconstruct high $p_T$ muons in proton--proton collisions are presented as well as the measurement of the environmental background rate to produce hits in the GEM detector.
△ Less
Submitted 22 September, 2021; v1 submitted 20 July, 2021;
originally announced July 2021.
-
Modeling the triple-GEM detector response to background particles for the CMS Experiment
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
I. Azhgirey,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi
, et al. (164 additional authors not shown)
Abstract:
An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The…
▽ More
An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The simulation framework uses a combination of the FLUKA and Geant4 packages to obtain the hit rate. FLUKA provides the radiation environment around the GE1/1 chambers, which is comprised of the particle flux with momentum direction and energy spectra ranging from $10^{-11}$ to $10^{4}$ MeV for neutrons, $10^{-3}$ to $10^{4}$ MeV for $γ$'s, $10^{-2}$ to $10^{4}$ MeV for $e^{\pm}$, and $10^{-1}$ to $10^{4}$ MeV for charged hadrons. Geant4 provides an estimate of detector response (sensitivity) based on an accurate description of detector geometry, material composition and interaction of particles with the various detector layers. The MC simulated hit rate is estimated as a function of the perpendicular distance from the beam line and agrees with data within the assigned uncertainties of 10-14.5%. This simulation framework can be used to obtain a reliable estimate of background rates expected at the High Luminosity LHC.
△ Less
Submitted 8 July, 2021;
originally announced July 2021.
-
Investigation and Mitigation of Crosstalk in the Prototype ME0 GEM Detector for the Phase-2 Muon System Upgrade of the CMS Experiment
Authors:
Stephen D. Butalla,
Marcus Hohlmann
Abstract:
The LHC is undergoing a high luminosity upgrade, which is set to increase the instantaneous luminosity by at least a factor of five, resulting in a higher muon flux rate in the forward region, which will overwhelm the current trigger system of the CMS experiment. The ME0, a gas electron multiplier detector, is proposed for the Phase-2 Muon System Upgrade to help increase the muon acceptance and to…
▽ More
The LHC is undergoing a high luminosity upgrade, which is set to increase the instantaneous luminosity by at least a factor of five, resulting in a higher muon flux rate in the forward region, which will overwhelm the current trigger system of the CMS experiment. The ME0, a gas electron multiplier detector, is proposed for the Phase-2 Muon System Upgrade to help increase the muon acceptance and to control the Level 1 muon trigger rate. To lower the probability of HV discharges, the ME0 was designed with GEM foils that are segmented on both sides. Initial testing of the ME0 showed substantial crosstalk between readout sectors. Here, we investigate, characterize, and quantify the crosstalk in the detector, and estimate the performance of the chamber as a result of this crosstalk via simulation of the detector dead time, efficiency loss, and frontend electronics response. The results of crosstalk via signals produced by applying a square voltage pulse directly on the readout strips of the detector with a pulser are summarized, and the efficacy of various mitigation strategies are presented. The crosstalk is a result of capacitive coupling between the readout strips on the readout board and between the readout strips and the bottom of GEM3. The crosstalk also generally follows a pattern where the largest magnitude of crosstalk is within the same azimuthal readout segment in the detector and in the nearest horizontal segments. The use of bypass capacitors and larger HV segments successfully reduce the crosstalk: we observe a maximum decrease of crosstalk in sectors previously experiencing crosstalk from $(1.66\pm0.03)\%$ to $(1.11\pm0.02)\%$ with all HV segments connected in parallel on the bottom of GEM3, with an HV low-pass filter, and an HV divider. These mitigation strategies slightly increase crosstalk $\big(\hspace{-0.1cm}\lessapprox 0.4\%\big)$ in readout sectors farther away.
△ Less
Submitted 5 February, 2021;
originally announced February 2021.
-
Interstrip Capacitances of the Readout Board used in Large Triple-GEM Detectors for the CMS Muon Upgrade
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi,
O. Bouhali
, et al. (156 additional authors not shown)
Abstract:
We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequent…
▽ More
We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequently maximize the signal-to-noise ratio for the detector. We find agreement at the 1.5--4.8% level between the two methods of calculations and on the average at the 17% level between calculations and measurements. A configuration with halved strip lengths and doubled strip widths results in a measured 27--29% reduction over the original configuration while leaving the total number of strips unchanged. We have now adopted this design modification for all eight module types of the GE2/1 detector and will produce the final detector with this new strip design.
△ Less
Submitted 20 September, 2020;
originally announced September 2020.