Wireless User-Generic Ear EEG
Authors:
Ryan Kaveh,
Justin Doong,
Andy Zhou,
Carolyn Schwendeman,
Karthik Gopalan,
Fred Burghardt,
Ana C. Arias,
Michel Maharbiz,
Rikky Muller
Abstract:
In the past few years it has been demonstrated that electroencephalography (EEG) can be recorded from inside the ear (in-ear EEG). To open the door to low-profile earpieces as wearable brain-computer interfaces (BCIs), this work presents a practical in-ear EEG device based on multiple dry electrodes, a user-generic design, and a lightweight wireless interface for streaming data and device programm…
▽ More
In the past few years it has been demonstrated that electroencephalography (EEG) can be recorded from inside the ear (in-ear EEG). To open the door to low-profile earpieces as wearable brain-computer interfaces (BCIs), this work presents a practical in-ear EEG device based on multiple dry electrodes, a user-generic design, and a lightweight wireless interface for streaming data and device programming. The earpiece is designed for improved ear canal contact across a wide population of users and is fabricated in a low-cost and scalable manufacturing process based on standard techniques such as vacuum forming,plasma-treatment, and spray coating. A 2.5x2.5 cm^2 wireless recording module is designed to record and stream data wirelessly to a host computer. Performance was evaluated on three human subjects over three months and compared with clinical-grade wet scalp EEG recordings. Recordings of spontaneous and evoked physiological signals, eye-blinks, alpha rhythm, and the auditory steady-state response (ASSR), are presented. This is the first wireless in-ear EEG to our knowledge to incorporate a dry multielectrode, user-generic design. The user-generic ear EEG recorded a mean alpha modulation of 2.17, outperforming the state-of-the-art in dry electrode in-ear EEG systems.
△ Less
Submitted 29 April, 2020; v1 submitted 1 March, 2020;
originally announced March 2020.
-
An EMG Gesture Recognition System with Flexible High-Density Sensors and Brain-Inspired High-Dimensional Classifier
Authors:
Ali Moin,
Andy Zhou,
Abbas Rahimi,
Simone Benatti,
Alisha Menon,
Senam Tamakloe,
Jonathan Ting,
Natasha Yamamoto,
Yasser Khan,
Fred Burghardt,
Luca Benini,
Ana C. Arias,
Jan M. Rabaey
Abstract:
EMG-based gesture recognition shows promise for human-machine interaction. Systems are often afflicted by signal and electrode variability which degrades performance over time. We present an end-to-end system combating this variability using a large-area, high-density sensor array and a robust classification algorithm. EMG electrodes are fabricated on a flexible substrate and interfaced to a custo…
▽ More
EMG-based gesture recognition shows promise for human-machine interaction. Systems are often afflicted by signal and electrode variability which degrades performance over time. We present an end-to-end system combating this variability using a large-area, high-density sensor array and a robust classification algorithm. EMG electrodes are fabricated on a flexible substrate and interfaced to a custom wireless device for 64-channel signal acquisition and streaming. We use brain-inspired high-dimensional (HD) computing for processing EMG features in one-shot learning. The HD algorithm is tolerant to noise and electrode misplacement and can quickly learn from few gestures without gradient descent or back-propagation. We achieve an average classification accuracy of 96.64% for five gestures, with only 7% degradation when training and testing across different days. Our system maintains this accuracy when trained with only three trials of gestures; it also demonstrates comparable accuracy with the state-of-the-art when trained with one trial.
△ Less
Submitted 5 April, 2018; v1 submitted 27 February, 2018;
originally announced February 2018.
-
WAND: A 128-channel, closed-loop, wireless artifact-free neuromodulation device
Authors:
Andy Zhou,
Samantha R. Santacruz,
Benjamin C. Johnson,
George Alexandrov,
Ali Moin,
Fred L. Burghardt,
Jan M. Rabaey,
Jose M. Carmena,
Rikky Muller
Abstract:
Closed-loop neuromodulation systems aim to treat a variety of neurological conditions by dynamically delivering and adjusting therapeutic electrical stimulation in response to a patient's neural state, recorded in real-time. Existing systems are limited by low channel counts, lack of algorithmic flexibility, and distortion of recorded signals from large, persistent stimulation artifacts. Here, we…
▽ More
Closed-loop neuromodulation systems aim to treat a variety of neurological conditions by dynamically delivering and adjusting therapeutic electrical stimulation in response to a patient's neural state, recorded in real-time. Existing systems are limited by low channel counts, lack of algorithmic flexibility, and distortion of recorded signals from large, persistent stimulation artifacts. Here, we describe a device that enables new research applications requiring high-throughput data streaming, low-latency biosignal processing, and truly simultaneous sensing and stimulation. The Wireless Artifact-free Neuromodulation Device (WAND) is a miniaturized, wireless neural interface capable of recording and stimulating on 128 channels with on-board processing to fully cancel stimulation artifacts, detect neural biomarkers, and automatically adjust stimulation parameters in a closed-loop fashion. It combines custom application specific integrated circuits (ASICs), an on-board FPGA, and a low-power bidirectional radio. We validate wireless, long-term recordings of local field potentials (LFP) and real-time cancellation of stimulation artifacts in a behaving nonhuman primate (NHP). We use WAND to demonstrate a closed-loop stimulation paradigm to disrupt movement preparatory activity during a delayed-reach task in a NHP in vivo. This wireless device, leveraging custom ASICs for both neural recording and electrical stimulation modalities, makes possible a neural interface platform technology to significantly advance both neuroscientific discovery and preclinical investigations of stimulation-based therapeutic interventions.
△ Less
Submitted 29 May, 2018; v1 submitted 1 August, 2017;
originally announced August 2017.