Measurement of track structure parameters of low and medium energy helium and carbon ions in nanometric volumes
Authors:
G. Hilgers,
M. U. Bug,
H. Rabus
Abstract:
Ionisation cluster size distributions produced in the sensitive volume of an ion-counting wall-less nanodosimeter by monoenergetic carbon ions with energies between 45 MeV and 150 MeV were measured at the TANDEM-ALPI ion accelerator facility complex of the LNL INFN in Legnaro. Those produced by monoenergetic helium ions with energies between 2 MeV and 20 MeV were measured at the accelerator facili…
▽ More
Ionisation cluster size distributions produced in the sensitive volume of an ion-counting wall-less nanodosimeter by monoenergetic carbon ions with energies between 45 MeV and 150 MeV were measured at the TANDEM-ALPI ion accelerator facility complex of the LNL INFN in Legnaro. Those produced by monoenergetic helium ions with energies between 2 MeV and 20 MeV were measured at the accelerator facilities of PTB and with a 241Am alpha particle source. C3H8 was used as the target gas. The ionisation cluster size distributions were measured in narrow beam geometry with the primary beam passing the target volume at specified distances from its centre, and in broad beam geometry with a fan-like primary beam. By applying a suitable drift time window, the effective size of the target volume was adjusted to match the size of a DNA segment. The measured data were compared with the results of simulations obtained with the PTB Monte Carlo code PTra. Before the comparison, the simulated cluster size distributions were corrected with respect to the background of additional ionisations produced in the transport system of the ionised target gas molecules. Measured and simulated characteristics of the particle track structure are in good agreement for both types of primary particles and for both types of the irradiation geometry.
△ Less
Submitted 10 February, 2017;
originally announced February 2017.
SoLEXS - A low-energy X-ray Spectrometer for Solar Coronal Studies
Authors:
K. Sankarasubramanian,
M. C. Ramadevi,
Monoj Bug,
C. N. Umapathy,
S. Seetha,
P. Sreekumar,
Kumar
Abstract:
A Solar Low-energy X-ray Spectrometer (SoLEXS), a high spectral resolution (\leq 250 eV at 5.9 keV) instrument with soft X-ray energy coverage (\leq 1.5 keV), is being proposed as an additional payload on-board Aditya-1. The motivation behind this is to complement the visible emission line space solar coronagraph, the main payload on Aditya-1. The science goals in which SoLEXS data will compliment…
▽ More
A Solar Low-energy X-ray Spectrometer (SoLEXS), a high spectral resolution (\leq 250 eV at 5.9 keV) instrument with soft X-ray energy coverage (\leq 1.5 keV), is being proposed as an additional payload on-board Aditya-1. The motivation behind this is to complement the visible emission line space solar coronagraph, the main payload on Aditya-1. The science goals in which SoLEXS data will compliment the main payload are: (i) Understanding of DC heating mechanism, (ii) Studies on the Flare-CME relations from the same platform, (iii) Independent and accurate estimates of temperature and emission measure at the flaring sites, and (iv) Coronal abundance studies and its variations during flares. Apart from these four major science goals, this instrument in principle can provide a flare trigger to the main payload and help in optimizing the on-board memory storage.
△ Less
Submitted 24 November, 2011;
originally announced November 2011.