Skip to main content

Showing 1–3 of 3 results for author: Buechele, S W

.
  1. arXiv:2007.11614  [pdf, other

    physics.atom-ph physics.chem-ph

    Optical Mass Spectrometry of Cold $\mathrm{RaOH}^+$ and ${\mathrm{RaOCH}_3}^+$

    Authors: M. Fan, C. A. Holliman, X. Shi, H. Zhang, M. W. Straus, X. Li, S. W. Buechele, A. M. Jayich

    Abstract: We present an all-optical mass spectrometry technique to identify trapped ions. The new method uses laser-cooled ions to determine the mass of a cotrapped dark ion with a sub-dalton resolution within a few seconds. We apply the method to identify the first controlled synthesis of cold, trapped $\mathrm{RaOH}^+$ and ${\mathrm{RaOCH}_3}^+$. These molecules are promising for their sensitivity to time… ▽ More

    Submitted 11 January, 2021; v1 submitted 22 July, 2020; originally announced July 2020.

    Comments: Main text 5 pages, 4 figures. Supplemental material 5 pages, 3 figures

    Journal ref: Phys. Rev. Lett. 126, 023002 (2021)

  2. arXiv:2005.05483  [pdf, other

    physics.ins-det physics.atom-ph

    A Transition-edge Sensor-based X-ray Spectrometer for the Study of Highly Charged Ions at the National Institute of Standards and Technology Electron Beam Ion Trap

    Authors: P. Szypryt, G. C. O'Neil, E. Takacs, J. N. Tan, S. W. Buechele, A. S. Naing, D. A. Bennett, W. B. Doriese, M. Durkin, J. W. Fowler, J. D. Gard, G. C. Hilton, K. M. Morgan, C. D. Reintsema, D. R. Schmidt, D. S. Swetz, J. N. Ullom, Yu. Ralchenko

    Abstract: We report on the design, commissioning, and initial measurements of a Transition-edge Sensor (TES) x-ray spectrometer for the Electron Beam Ion Trap (EBIT) at the National Institute of Standards and Technology (NIST). Over the past few decades, the NIST EBIT has produced numerous studies of highly charged ions in diverse fields such as atomic physics, plasma spectroscopy, and laboratory astrophysi… ▽ More

    Submitted 11 May, 2020; originally announced May 2020.

  3. arXiv:2005.05395  [pdf, other

    physics.ins-det cond-mat.other

    On low-energy tail distortions in the detector responsefunction of x-ray microcalorimeter spectrometers

    Authors: G. C. O'Neil, P. Szypryt, E. Takacs, J. N. Tan, S. W. Buechele, A. S. Naing, Y. I. Joe, D. Swetz, D. R. Schmidt, W. B. Doriese, J. D. Gard, C. D. Reintsema, J. N. Ullom, J. S. Villarrubia, Yu. Ralchenko

    Abstract: We use narrow spectral lines from the x-ray spectra of various highlycharged ions to measure low-energy tail-like deviations from a Gaussian responsefunction in a microcalorimter x-ray spectrometer with Au absorbers at energiesfrom 650 eV to 3320 eV. We review the literature on low energy tails in othermicrocalorimter x-ray spectrometers and present a model that explains all thereviewed tail fract… ▽ More

    Submitted 11 May, 2020; originally announced May 2020.