-
Dose-response curve of EBT, EBT2, and EBT3 radiochromic films to synchrotron-produced monochromatic x-ray beams
Authors:
Thomas A. D. Brown,
Kenneth R. Hogstrom,
Diane Alvarez,
Kenneth L. Matthews II,
Kyungmin Ham,
Joseph P. Dugas
Abstract:
This work investigates the dose-response curves of GAFCHROMIC EBT, EBT2, and EBT3 radiochromic films using synchrotron-produced monochromatic x-ray beams. EBT2 film is being utilized for dose verification in photoactivated Auger electron therapy at the Louisiana State University CAMD synchrotron facility. Monochromatic beams of 25, 30, and 35 keV were generated on the tomography beamline at CAMD.…
▽ More
This work investigates the dose-response curves of GAFCHROMIC EBT, EBT2, and EBT3 radiochromic films using synchrotron-produced monochromatic x-ray beams. EBT2 film is being utilized for dose verification in photoactivated Auger electron therapy at the Louisiana State University CAMD synchrotron facility. Monochromatic beams of 25, 30, and 35 keV were generated on the tomography beamline at CAMD. Ion chamber depth-dose measurements were used to determine the dose delivered to films irradiated at depths from 0.7 to 8.5 cm in a 10x10x10-cm3 PMMA phantom. AAPM TG-61 protocol was applied to convert measured ionization into dose. Films were digitized using an Epson 1680 Professional flatbed scanner and analyzed using the net optical density (NOD) derived from the red channel. A dose-response curve was obtained at 35 keV for EBT film, and at 25, 30, and 35 keV for EBT2 and EBT3 films. Calibrations of films for 4 MV x-rays were obtained for comparison using a radiotherapy accelerator at Mary Bird Perkins Cancer Center. The sensitivity (NOD per unit dose) of EBT film at 35 keV relative to that for 4-MV x-rays was 0.73 and 0.76 for doses 50 and 100 cGy, respectively. The sensitivity of EBT2 film at 25, 30, and 35 keV relative to that for 4-MV x-rays varied from 1.09 - 1.07, 1.23 - 1.17, and 1.27 - 1.19 for doses 50 - 200 cGy, respectively. For EBT3 film the relative sensitivity was within 3% of unity for all three monochromatic x-ray beams. EBT and EBT2 film sensitivity showed strong energy dependence over an energy range of 25 keV - 4 MV, although this dependence becomes weaker for larger doses. EBT3 film shows weak energy dependence, indicating that it would be a better dosimeter for kV x-ray beams where beam hardening effects can result in large changes in the effective energy.
△ Less
Submitted 4 December, 2012;
originally announced December 2012.
-
Verification of TG-61 dose for synchrotron-produced monochromatic x-ray beams using fluence-normalized MCNP5 calculations
Authors:
Thomas A. D. Brown,
Kenneth R. Hogstrom,
Diane Alvarez,
Kenneth L. Matthews II,
Kyungmin Ham
Abstract:
Ion chamber dosimetry is being used to calibrate dose for cell irradiations designed to investigate photoactivated Auger electron therapy at the Louisiana State University CAMD synchrotron facility. This study performed a dosimetry intercomparison for synchrotron-produced monochromatic x-ray beams at 25 and 35 keV. Ion chamber depth-dose measurements in a PMMA phantom were compared with the produc…
▽ More
Ion chamber dosimetry is being used to calibrate dose for cell irradiations designed to investigate photoactivated Auger electron therapy at the Louisiana State University CAMD synchrotron facility. This study performed a dosimetry intercomparison for synchrotron-produced monochromatic x-ray beams at 25 and 35 keV. Ion chamber depth-dose measurements in a PMMA phantom were compared with the product of MCNP5 Monte Carlo calculations of dose per fluence and measured incident fluence. Monochromatic beams of 25 and 35 keV were generated on the tomography beamline at CAMD. A cylindrical, air-equivalent ion chamber was used to measure the ionization created in a 10x10x10-cm3 PMMA phantom for depths from 0.6 to 7.7 cm. The American Association of Physicists in Medicine TG-61 protocol was applied to convert measured ionization into dose. Photon fluence was determined using a NaI detector to make scattering measurements of the beam from a thin polyethylene target at angles 30 degrees to 60 degrees. Differential Compton and Rayleigh scattering cross sections obtained from xraylib, an ANSI C library for x-ray-matter interactions, were applied to derive the incident fluence. MCNP5 simulations of the irradiation geometry provided the dose deposition per photon fluence as a function of depth in the phantom. At 25 keV the fluence-normalized MCNP5 dose overestimated the ion-chamber measured dose by an average of 7.2+/-3.0% to 2.1+/-3.0% for PMMA depths from 0.6 to 7.7 cm, respectively. At 35 keV the fluence-normalized MCNP5 dose underestimated the ion-chamber measured dose by an average of 1.0+/-3.4% to 2.5+/-3.4%, respectively. These results showed that TG-61 ion chamber dosimetry, used to calibrate dose output for cell irradiations, agreed with fluence-normalized MCNP5 calculations to within approximately 7% and 3% at 25 and 35 keV, respectively.
△ Less
Submitted 4 December, 2012;
originally announced December 2012.
-
Absolute Determination of the 22Na(p,g) Reaction Rate in Novae
Authors:
A. L. Sallaska,
C. Wrede,
A. Garcia,
D. W. Storm,
T. A. D. Brown,
C. Ruiz,
K. A. Snover,
D. F. Ottewell,
L. Buchmann,
C. Vockenhuber,
D. A. Hutcheon,
J. A. Caggiano,
J. Jose
Abstract:
Gamma-ray telescopes in orbit around the Earth are searching for evidence of the elusive radionuclide 22Na produced in novae. Previously published uncertainties in the dominant destructive reaction, 22Na(p,g)23Mg, indicated new measurements in the proton energy range of 150 to 300 keV were needed to constrain predictions. We have measured the resonance strengths, energies, and branches directly an…
▽ More
Gamma-ray telescopes in orbit around the Earth are searching for evidence of the elusive radionuclide 22Na produced in novae. Previously published uncertainties in the dominant destructive reaction, 22Na(p,g)23Mg, indicated new measurements in the proton energy range of 150 to 300 keV were needed to constrain predictions. We have measured the resonance strengths, energies, and branches directly and absolutely by using protons from the University of Washington accelerator with a specially designed beamline, which included beam rastering and cold vacuum protection of the 22Na implanted targets. The targets, fabricated at TRIUMF-ISAC, displayed minimal degradation over a ~ 20 C bombardment as a result of protective layers. We avoided the need to know the stop** power, and hence the target composition, by extracting resonance strengths from excitation functions integrated over proton energy. Our measurements revealed that resonance strengths for E_p = 213, 288, 454, and 610 keV are stronger by factors of 2.4 to 3.2 than previously reported. Upper limits have been placed on proposed resonances at 198-, 209-, and 232-keV. We have re-evaluated the 22Na(p,g) reaction rate, and our measurements indicate the resonance at 213 keV makes the most significant contribution to 22Na destruction in novae. Hydrodynamic simulations including our rate indicate that the expected abundance of 22Na ejecta from a classical nova is reduced by factors between 1.5 and 2, depending on the mass of the white-dwarf star hosting the nova explosion.
△ Less
Submitted 4 February, 2011; v1 submitted 20 September, 2010;
originally announced September 2010.
-
Direct measurements of 22Na(p,g)23Mg resonances and consequences for 22Na production in classical novae
Authors:
A. L. Sallaska,
C. Wrede,
A. Garcia,
D. W. Storm,
T. A. D. Brown,
C. Ruiz,
K. A. Snover,
D. F. Ottewell,
L. Buchmann,
C. Vockenhuber,
D. A. Hutcheon,
J. A. Caggiano
Abstract:
The radionuclide 22Na is a potential astronomical observable that is expected to be produced in classical novae in quantities that depend on the thermonuclear rate of the 22Na(p,g)23Mg reaction. We have measured the strengths of low-energy 22Na(p,g)23Mg resonances directly and absolutely using a radioactive 22Na target. We find the strengths of resonances at E_p = 213, 288, 454, and 610 keV to be…
▽ More
The radionuclide 22Na is a potential astronomical observable that is expected to be produced in classical novae in quantities that depend on the thermonuclear rate of the 22Na(p,g)23Mg reaction. We have measured the strengths of low-energy 22Na(p,g)23Mg resonances directly and absolutely using a radioactive 22Na target. We find the strengths of resonances at E_p = 213, 288, 454, and 610 keV to be higher than previous measurements by factors of 2.4 to 3.2, and we exclude important contributions to the rate from proposed resonances at E_p = 198, 209, and 232 keV. The 22Na abundances expected in the ejecta of classical novae are reduced by a factor of ~ 2.
△ Less
Submitted 24 September, 2010; v1 submitted 24 August, 2010;
originally announced August 2010.
-
The 3He + 4He --> 7Be Astrophysical S-factor
Authors:
T. A. D. Brown,
C. Bordeanu,
K. A. Snover,
D. W. Storm,
D. Melconian,
A. L. Sallaska,
S. K. L. Sjue,
S. Triambak
Abstract:
We present precision measurements of the 3He + 4He --> 7Be reaction in the range ECM = 0.33 to 1.23 MeV using a small gas cell and detection of both prompt gamma rays and 7Be activity. Our prompt and activity measurements are in good agreement within an experimental uncertainty of several percent. We find S(0) = 0.595 +/- 0.018 keV b from fits of the Ka**o theory to our data. We compare our res…
▽ More
We present precision measurements of the 3He + 4He --> 7Be reaction in the range ECM = 0.33 to 1.23 MeV using a small gas cell and detection of both prompt gamma rays and 7Be activity. Our prompt and activity measurements are in good agreement within an experimental uncertainty of several percent. We find S(0) = 0.595 +/- 0.018 keV b from fits of the Ka**o theory to our data. We compare our results with published measurements, and we discuss the consequences for Big Bang Nucleosynthesis and for solar neutrino flux calculations.
△ Less
Submitted 5 November, 2007; v1 submitted 5 October, 2007;
originally announced October 2007.