-
An Experimentally Benchmarked Geant4 SiPM-Based Scintillator Detector Simulation Platform for Gamma Ray Detection
Authors:
Lysander Miller,
Airlie Chapman,
Katie Auchettl,
Jeremy M. C. Brown
Abstract:
Radiation detection is vital for naturally occurring radioactive material detection, port and border monitoring, and homeland security operations. SiPM-based single-volume scintillator detectors offer a cost-effective and robust solution that enables timely radioactive site surveys, while retaining accuracy and sensitivity sufficient for isotope identification. Enhanced site surveying can be achie…
▽ More
Radiation detection is vital for naturally occurring radioactive material detection, port and border monitoring, and homeland security operations. SiPM-based single-volume scintillator detectors offer a cost-effective and robust solution that enables timely radioactive site surveys, while retaining accuracy and sensitivity sufficient for isotope identification. Enhanced site surveying can be achieved by optimising scintillator detector design. In this work, a detailed GAGG:Ce, CLLBC:Ce, BGO, NaI:Tl, and CsI:Tl SiPM-based scintillator detector simulation platform was developed with the Monte Carlo radiation transport toolkit, Geant4, and experimentally benchmarked. This simulation platform successfully predicted the spectral features for selected gamma ray emitting isotopes with energies between 30 keV to 2 MeV. The full width half maximum (FWHM) and normalised cross-correlation coefficient (NCCC) between simulated and experimental energy spectra were also compared. The majority of simulated FWHM values reproduced the experimental results within 2% and the NCCC values demonstrated agreement between the simulated and experimental energy spectra. Discrepancies in these figures of merit can be attributed to detector signal processing electronics modelling, geometry approximations, and multiple Compton scattering within the detector and surrounding environment.
△ Less
Submitted 5 March, 2024;
originally announced March 2024.
-
Modelling the Response of CLLBC(Ce) and TLYC(Ce) SiPM-Based Radiation Detectors in Mixed Radiation Fields with Geant4
Authors:
Jeremy M. C. Brown,
Lachlan Chartier,
David Boardman,
John Barnes,
Alison Flynn
Abstract:
CLLBC(Ce) and TLYC(Ce) are novel scintillation materials capable of measuring mixed gamma ray and neutron radiation fields that have gained significant interest in the areas of space and nuclear safety/security science. To date Geant4, the world's most popular Monte Carlo radiation modelling toolkit, has yet to be effectively used to simulate the full response of these materials when coupled to ne…
▽ More
CLLBC(Ce) and TLYC(Ce) are novel scintillation materials capable of measuring mixed gamma ray and neutron radiation fields that have gained significant interest in the areas of space and nuclear safety/security science. To date Geant4, the world's most popular Monte Carlo radiation modelling toolkit, has yet to be effectively used to simulate the full response of these materials when coupled to near ultra-violet Silicon PhotoMultipliers (SiPMs). In this work an experimentally validated Geant4 application has been developed with optimised material composition, optical data tables, and physics transport settings that is able to accurately simulate the response of CLLBC(Ce) and TLYC(Ce) SiPM-based radiation detectors under both gamma ray and neutron irradiation. Experimental benchmarking for five different radioactive sources (Co-60, Cs-137, Eu-152, Am-241, and Cf-252) illustrated that this developed Geant4 application was able to reproduce the position and structure of all major spectral features (full energy gamma ray photo-/neutron capture peaks, X-ray escape photopeaks, Compton edge, Compton backscatter peaks, and Compton plateau) to high level of accuracy.
△ Less
Submitted 16 March, 2023;
originally announced March 2023.
-
A Geant4 Based Simulation Platform of the HollandPTC R&D Proton Beamline for Radiobiological Studies
Authors:
C. F. Groenendijk,
M. Rovituso,
D. Lathouwers,
J. M. C. Brown
Abstract:
A Geant4 based simulation platform of the Holland Proton Therapy Centre (HollandPTC, Netherlands) R&D beamline (G4HPTC-R&D) was developed to enable the planning, optimisation and advanced dosimetry for radiobiological studies. It implemented a six parameter non-symmetrical Gaussian pencil beam surrogate model to simulate the R&D beamline in both a pencil beam and passively scattered field configur…
▽ More
A Geant4 based simulation platform of the Holland Proton Therapy Centre (HollandPTC, Netherlands) R&D beamline (G4HPTC-R&D) was developed to enable the planning, optimisation and advanced dosimetry for radiobiological studies. It implemented a six parameter non-symmetrical Gaussian pencil beam surrogate model to simulate the R&D beamline in both a pencil beam and passively scattered field configuration. Three different experimental proton datasets (70 MeV, 150 MeV, and 240 MeV) of the pencil beam envelope evolution in free air and depth-dose profiles in water were used to develop a set of individual parameter surrogate functions to enable the modelling of the non-symmetrical Gaussian pencil beam properties with only the ProBeam isochronous cyclotron mean extraction proton energy as input. This refined beam model was then benchmarked with respect to three independent experimental datasets of the R&D beamline operating in both a pencil beam configuration at 120 and 200 MeV, and passively scattered field configuration at 150 MeV. It was shown that the G4HPTC-R&D simulation platform can reproduce the pencil beam envelope evolution in free air and depth-dose profiles to within an accuracy on the order of $\pm$5% for all tested energies, and that it was able to reproduce the 150 MeV passively scattered field to the specifications need for clinical and radiobiological applications.
△ Less
Submitted 30 May, 2023; v1 submitted 20 February, 2023;
originally announced February 2023.
-
Characterisation of the HollandPTC R&D proton beamline for physics and radiobiology studies
Authors:
M. Rovituso,
C. F. Groenendijk,
E. van der Wal,
W. van Burik,
A. Ibrahimi,
H. Rituerto Prieto,
J. M. C. Brown,
U. Weber,
Y. Simeonov,
M. Fontana,
D. Lathouwers,
M. van Vulpen,
M. Hoogeman
Abstract:
HollandPTC is an independent outpatient center for proton therapy, scientific research, and education. Patients with different types of cancer are treated with Intensity Modulated Proton Therapy (IMPT). In addition, the HollandPTC R&D consortium conducts scientific research into the added value and improvements of proton therapy. To this end, HollandPTC created clinical and pre-clinical research f…
▽ More
HollandPTC is an independent outpatient center for proton therapy, scientific research, and education. Patients with different types of cancer are treated with Intensity Modulated Proton Therapy (IMPT). In addition, the HollandPTC R&D consortium conducts scientific research into the added value and improvements of proton therapy. To this end, HollandPTC created clinical and pre-clinical research facilities including a versatile R&D proton beamline for various types of biologically and technologically oriented research. In this work, we present the characterization of the R&D proton beam line of HollandPTC. Its pencil beam mimics the one used for clinical IMPT, with energy ranging from 70 up to 240 MeV, which has been characterized in terms of shape, size, and intensity. For experiments that need a uniform field in depth and lateral directions, a dual ring passive scattering system has been designed, built, and characterized. With this system, field sizes between 2x2 cm2 and 20x20 cm2 with 98% uniformity are produced with dose rates ranging from 0.5 Gy/min up to 9 Gy/min. The unique and customized support of the dual ring system allows switching between a pencil beam and a large field in a very simple and fast way, making the HollandPTC R&D proton beam able to support a wide range of different applications.
△ Less
Submitted 20 February, 2023;
originally announced February 2023.
-
Simulation of DNA damage using Geant4-DNA: an overview of the "molecularDNA" example application
Authors:
Konstantinos P. Chatzipapas,
Ngoc Hoang Tran,
Milos Dordevic,
Sara Zivkovic,
Sara Zein,
Wook Geun Shin,
Dousatsu Sakata,
Nathanael Lampe,
Jeremy M. C. Brown,
Aleksandra Ristic-Fira,
Ivan Petrovic,
Ioanna Kyriakou,
Dimitris Emfietzoglou,
Susanna Guatelli,
Sébastien Incerti
Abstract:
The scientific community shows a great interest in the study of DNA damage induction, DNA damage repair and the biological effects on cells and cellular systems after exposure to ionizing radiation. Several in-silico methods have been proposed so far to study these mechanisms using Monte Carlo simulations. This study outlines a Geant4-DNA example application, named "molecularDNA", publicly release…
▽ More
The scientific community shows a great interest in the study of DNA damage induction, DNA damage repair and the biological effects on cells and cellular systems after exposure to ionizing radiation. Several in-silico methods have been proposed so far to study these mechanisms using Monte Carlo simulations. This study outlines a Geant4-DNA example application, named "molecularDNA", publicly released in the 11.1 version of Geant4 (December 2022). It was developed for novice Geant4 users and requires only a basic understanding of scripting languages to get started. The example currently proposes two different DNA-scale geometries of biological targets, namely "cylinders", and the "human cell". This public version is based on a previous prototype and includes new features such as: the adoption of a new approach for the modeling of the chemical stage (IRT-sync), the use of the Standard DNA Damage (SDD) format to describe radiation-induced DNA damage and upgraded computational tools to estimate DNA damage response. Simulation data in terms of single strand break (SSB) and double strand break (DSB) yields were produced using each of these geometries. The results were compared to the literature, to validate the example, producing less than 5 % difference in all cases.
△ Less
Submitted 20 March, 2023; v1 submitted 4 October, 2022;
originally announced October 2022.
-
A new Standard DNA damage (SDD) data format
Authors:
J. Schuemann,
A. McNamara,
J. W. Warmenhoven,
N. T. Henthorn,
K. Kirkby,
M. J. Merchant,
S. Ingram,
H. Paganetti,
KD. Held,
J. Ramos-Mendez,
B. Faddegon,
J. Perl,
D. Goodhead,
I. Plante,
H. Rabus,
H. Nettelbeck,
W. Friedland,
P. Kundrat,
A. Ottolenghi,
G. Baiocco,
S. Barbieri,
M. Dingfelder,
S. Incerti,
C. Villagrasa,
M. Bueno
, et al. (26 additional authors not shown)
Abstract:
Our understanding of radiation induced cellular damage has greatly improved over the past decades. Despite this progress, there are still many obstacles to fully understanding how radiation interacts with biologically relevant cellular components to form observable endpoints. One hurdle is the difficulty faced by members of different research groups in directly comparing results. Multiple Monte Ca…
▽ More
Our understanding of radiation induced cellular damage has greatly improved over the past decades. Despite this progress, there are still many obstacles to fully understanding how radiation interacts with biologically relevant cellular components to form observable endpoints. One hurdle is the difficulty faced by members of different research groups in directly comparing results. Multiple Monte Carlo codes have been developed to simulate damage induction at the DNA scale, while at the same time various groups have developed models that describe DNA repair processes with varying levels of detail. These repair models are intrinsically linked to the damage model employed in their development, making it difficult to disentangle systematic effects in either part of the modelling chain. The modelling chain typically consists of track structure Monte Carlo simulations of the physics interactions creating direct damages to the DNA; followed by simulations of the production and initial reactions of chemical species causing indirect damages. After the DNA damage induction, DNA repair models combine the simulated damage patterns with biological models to determine the biological consequences of the damage. We propose a new Standard data format for DNA Damage to unify the interface between the simulation of damage induction and the biological modelling of cell repair processes. Such a standard greatly facilitates inter model comparisons, providing an ideal environment to tease out model assumptions and identify persistent, underlying mechanisms. Through inter model comparisons, this unified standard has the potential to greatly advance our understanding of the underlying mechanisms of radiation induced DNA damage and the resulting observable biological effects.
△ Less
Submitted 11 January, 2022;
originally announced January 2022.
-
Pressure-induced shift of effective Ce valence, Fermi energy and phase boundaries in CeOs$_4$Sb$_{12}$
Authors:
K. Götze,
M. J. Pearce,
M. J. Coak,
P. A. Goddard,
A. D. Grockowiak,
W. A. Coniglio,
S. W. Tozer,
D. E. Graf,
M. B. Maple,
P. -C. Ho,
M. C. Brown,
J. Singleton
Abstract:
CeOs$_4$Sb$_{12}$, a member of the skutterudite family, has an unusual semimetallic low-temperature $\cal{L}$-phase that inhabits a wedge-like area of the field $H$ - temperature $T$ phase diagram. We have conducted measurements of electrical transport and megahertz conductivity on CeOs$_4$Sb$_{12}$ single crystals under pressures of up to 3 GPa and in high magnetic fields of up to 41 T to investi…
▽ More
CeOs$_4$Sb$_{12}$, a member of the skutterudite family, has an unusual semimetallic low-temperature $\cal{L}$-phase that inhabits a wedge-like area of the field $H$ - temperature $T$ phase diagram. We have conducted measurements of electrical transport and megahertz conductivity on CeOs$_4$Sb$_{12}$ single crystals under pressures of up to 3 GPa and in high magnetic fields of up to 41 T to investigate the influence of pressure on the different $H$-$T$ phase boundaries. While the high-temperature valence transition between the metallic $\cal{H}$-phase and the $\cal{L}$-phase is shifted to higher $T$ by pressures of the order of 1 GPa, we observed only a marginal suppression of the $\cal{S}$-phase that is found below 1 K for pressures of up to 1.91 GPa. High-field quantum oscillations have been observed for pressures up to 3.0 GPa and the Fermi surface of the high-field side of the $\cal{H}$-phase is found to show a surprising decrease in size with increasing pressure, implying a change in electronic structure rather than a mere contraction of lattice parameters. We evaluate the field-dependence of the effective masses for different pressures and also reflect on the sample dependence of some of the properties of CeOs$_4$Sb$_{12}$ which appears to be limited to the low-field region.
△ Less
Submitted 6 December, 2021;
originally announced December 2021.
-
An electromagnetic physics constructor for low energy polarised X-/gamma ray transport in Geant4
Authors:
Jeremy M. C. Brown,
Matthew R. Dimmock
Abstract:
The production, application, and/or measurement of polarised X-/gamma rays are key to the fields of synchrotron science and X-/gamma-ray astronomy. The design, development and optimisation of experimental equipment utilised in these fields typically relies on the use of Monte Carlo radiation transport modelling toolkits such as Geant4. In this work the Geant4 "G4LowEPPhysics" electromagnetic physi…
▽ More
The production, application, and/or measurement of polarised X-/gamma rays are key to the fields of synchrotron science and X-/gamma-ray astronomy. The design, development and optimisation of experimental equipment utilised in these fields typically relies on the use of Monte Carlo radiation transport modelling toolkits such as Geant4. In this work the Geant4 "G4LowEPPhysics" electromagnetic physics constructor has been reconfigured to offer a "best set" of electromagnetic physics models for studies exploring the transport of low energy polarised X-/gamma rays. An overview of the physics models implemented in "G4LowEPPhysics", and it's experimental validation against Compton X-ray polarimetry measurements of the BL38B1 beamline at the SPring-8 synchrotron (Sayo, Japan) is reported. "G4LowEPPhysics" is shown to be able to reproduce the experimental results obtained at the BL38B1 beamline (SPring-8) to within a level of accuracy on the same order as Geant4's X-/gamma ray interaction cross-sectional data uncertainty (approximately $\pm$ 5 \%).
△ Less
Submitted 6 February, 2021; v1 submitted 4 February, 2021;
originally announced February 2021.
-
Full field X-ray Scatter Tomography
Authors:
Gary Ruben,
Isaac Pinar,
Jeremy M. C. Brown,
Florian Schaff,
James A. Pollock,
Kelly J. Crossley,
Anton Maksimenko,
Chris Hall,
Daniel Hausermann,
Kentaro Uesugi,
Marcus J. Kitchen
Abstract:
In X-ray imaging, photons are transmitted through and absorbed by the subject, but are also scattered in significant quantities. Previous attempts to use scattered photons for biological imaging used pencil or fan beam illumination. Here we present 3D X-ray Scatter Tomography using full-field illumination. Synchrotron imaging experiments were performed of a phantom and the chest of a juvenile rat.…
▽ More
In X-ray imaging, photons are transmitted through and absorbed by the subject, but are also scattered in significant quantities. Previous attempts to use scattered photons for biological imaging used pencil or fan beam illumination. Here we present 3D X-ray Scatter Tomography using full-field illumination. Synchrotron imaging experiments were performed of a phantom and the chest of a juvenile rat. Transmitted and scattered photons were simultaneously imaged with separate cameras; a scientific camera directly downstream of the sample stage, and a pixelated detector with a pinhole imaging system placed at 45${}^\circ$ to the beam axis. We obtained scatter tomogram feature fidelity sufficient for segmentation of the lung and major airways in the rat. The image contrast in scatter tomogram slices approached that of transmission imaging, indicating robustness to the amount of multiple scattering present in our case. This opens the possibility of augmenting full-field 2D imaging systems with additional scatter detectors to obtain complementary modes or to improve the fidelity of existing images without additional dose, potentially leading to single-shot or reduced-angle tomography or overall dose reduction for live animal studies.
△ Less
Submitted 10 March, 2022; v1 submitted 16 December, 2020;
originally announced December 2020.
-
In-Silico Optimisation of Tileable Philips Digital SiPM Based Thin Monolithic Scintillator Detectors for SPECT Applications
Authors:
Jeremy M. C. Brown
Abstract:
Over the last decade one of the most significant technological advances made in the field of radiation detectors for nuclear medicine was the development of Silicon Photomultipler (SiPM) sensors. At present a only small number of SiPM based radiation detectors for Single Photon Emission Computed Tomography (SPECT) applications have been explored, and even fewer experimental prototypes developed. A…
▽ More
Over the last decade one of the most significant technological advances made in the field of radiation detectors for nuclear medicine was the development of Silicon Photomultipler (SiPM) sensors. At present a only small number of SiPM based radiation detectors for Single Photon Emission Computed Tomography (SPECT) applications have been explored, and even fewer experimental prototypes developed. An in-silico investigation into the optimal design of a Philips DPC3200 SiPM photosensor-based thin monolithic scintillator detector for SPECT applications was undertaken using the Monte Carlo radiation transport modelling toolkit Geant4 version 10.5. The performance of the 20 different SPECT radiation detector configurations, 4 scintillator materials (NaI(Tl), GAGG(Ce), CsI(Tl) and LaBr$_{3}$(Ce)) and 5 thicknesses (1 to 5 mm), were determined through the use of seven figures of merit. It was found that a crystal thickness range of 4 to 5 mm was required for all four materials to ensure acceptable energy resolution, sensitivity and spatial resolution performance with the Philips DPC3200 SiPM. Any thinner than this and the performance of all four materials was found to degrade rapidly due to a high probability of material specific fluorescence x-ray escape after incident gamma/x-ray photoelectric absorption. When factoring in each material's magnetic resonance imaging compatibility, hygroscopy, and cost, it was found that CsI(Tl) represents the most promising material to construct tileable Philips digital SiPM based thin monolithic scintillator detectors for SPECT applications.
△ Less
Submitted 31 July, 2020; v1 submitted 13 August, 2019;
originally announced August 2019.
-
A High Count-Rate and Depth-of-Interaction Resolving Single Layered One-Side Readout Pixelated Scintillator Crystal Array for PET Applications
Authors:
J. M. C. Brown,
S. E. Brunner,
D. R. Schaart
Abstract:
Organ-specific, targeted Field-of-View (FoV) Positron Emission Tomography (PET)/Magnetic Resonance Imaging (MRI) inserts are viable solutions for a number of imaging tasks where whole-body PET/MRI systems lack the necessary sensitivity and resolution. To meet the required PET detector performance of these systems, high count-rates and effective spatial resolutions on the order of a few mm, a novel…
▽ More
Organ-specific, targeted Field-of-View (FoV) Positron Emission Tomography (PET)/Magnetic Resonance Imaging (MRI) inserts are viable solutions for a number of imaging tasks where whole-body PET/MRI systems lack the necessary sensitivity and resolution. To meet the required PET detector performance of these systems, high count-rates and effective spatial resolutions on the order of a few mm, a novel two-axis patterned reflector foil pixelated scintillator crystal array design is developed and its proof-of-concept illustrated in-silico with the Monte Carlo radiation transport modelling toolkit Geant4. It is shown that the crystal surface roughness and phased open reflector cross-section patterns could be optimised to maximise either the PET radiation detector's effective spatial resolution, or count rate before event pile up. In addition, it was illustrated that these two parameters had minimal impact on the energy and time resolution of the proposed PET radiation detector design. Finally, it is shown that a PET radiation detector with balance performance could be constructed using ground crystals and phased open reflector cross-section pattern corresponding to the middle of the tested range.
△ Less
Submitted 18 September, 2019; v1 submitted 27 May, 2019;
originally announced May 2019.
-
Statistical Image Reconstruction for High-Throughput Thermal Neutron Computed Tomography
Authors:
Jeremy M. C. Brown,
Ulf Garbe,
Daniele Pelliccia
Abstract:
Neutron Computed Tomography (CT) is an increasingly utilised non-destructive analysis tool in material science, palaeontology, and cultural heritage. With the development of new neutron imaging facilities (such as DINGO, ANSTO, Australia) new opportunities arise to maximise their performance through the implementation of statistically driven image reconstruction methods which have yet to see wide…
▽ More
Neutron Computed Tomography (CT) is an increasingly utilised non-destructive analysis tool in material science, palaeontology, and cultural heritage. With the development of new neutron imaging facilities (such as DINGO, ANSTO, Australia) new opportunities arise to maximise their performance through the implementation of statistically driven image reconstruction methods which have yet to see wide scale application in neutron transmission tomography. This work outlines the implementation of a convex algorithm statistical image reconstruction framework applicable to the geometry of most neutron tomography instruments with the aim of obtaining similar imaging quality to conventional ramp filtered back-projection via the inverse Radon transform, but using a lower number of measured projections to increase object throughput. Through comparison of the output of these two frameworks using a tomographic scan of a known 3 material cylindrical phantom obtain with the DINGO neutron radiography instrument (ANSTO, Australia), this work illustrates the advantages of statistical image reconstruction techniques over conventional filter back-projection. It was found that the statistical image reconstruction framework was capable of obtaining image estimates of similar quality with respect to filtered back-projection using only 12.5% the number of projections, potentially increasing object throughput at neutron imaging facilities such as DINGO eight-fold.
△ Less
Submitted 21 May, 2019; v1 submitted 7 June, 2018;
originally announced June 2018.