-
Calibration of the EDELWEISS Cryogenic Heat-and-ionisation Germanium Detectors for Dark Matter Search
Authors:
The EDELWEISS Collaboration,
O. Martineau,
A. Benoit,
L. Berge,
A. Broniatowski,
L. Chabert,
B. Chambon,
M. Chapellier,
G. Chardin,
P. Charvin,
M. De Jesus,
P. Di Stefano,
D. Drain,
L. Dumoulin,
J. Gascon,
G. Gerbier,
E. Gerlic,
C. Goldbach,
M. Goyot,
M. Gros,
J. P. Hadjout,
S. Herve,
A. Juillard,
A. de Lesquen,
M. Loidl
, et al. (12 additional authors not shown)
Abstract:
Several aspects of the analysis of the data obtained with the cryogenic heat-and-ionisation Ge detectors used by the EDELWEISS dark matter search experiment are presented. Their calibration, the determination of their energy threshold, fiducial volume and nuclear recoil acceptance are detailed.
Several aspects of the analysis of the data obtained with the cryogenic heat-and-ionisation Ge detectors used by the EDELWEISS dark matter search experiment are presented. Their calibration, the determination of their energy threshold, fiducial volume and nuclear recoil acceptance are detailed.
△ Less
Submitted 22 October, 2003;
originally announced October 2003.
-
SICANE: a Detector Array for the Measurement of Nuclear Recoil Quenching Factors using Monoenergetic Neutron Beam
Authors:
E. Simon,
L. Berge,
A. Broniatowski,
R. Bouvier,
B. Chambon,
M. De Jesus,
D. Drain,
L. Dumoulin,
J. Gascon,
J. P. Hadjout,
A. Juillard,
O. Martineau,
C. Pastor,
M. Stern,
L. Vagneron
Abstract:
SICANE is a neutron scattering multidetector facility for the determination of the quenching factor (ratio of the response to nuclear recoils and to electrons) of cryogenic detectors used in direct WIMP searches. Well collimated monoenergetic neutron beams are obtained with inverse (p,n) reactions. The facility is described, and results obtained for the quenching factors of scintillation in NaI(…
▽ More
SICANE is a neutron scattering multidetector facility for the determination of the quenching factor (ratio of the response to nuclear recoils and to electrons) of cryogenic detectors used in direct WIMP searches. Well collimated monoenergetic neutron beams are obtained with inverse (p,n) reactions. The facility is described, and results obtained for the quenching factors of scintillation in NaI(Tl) and of heat and ionization in Ge are presented.
△ Less
Submitted 20 December, 2002;
originally announced December 2002.
-
Improved Exclusion Limits from the EDELWEISS WIMP Search
Authors:
A. Benoit,
L. Berge,
A. Broniatowski,
L. Chabert,
B. Chambon,
M. Chapellier,
G. Chardin,
P. Charvin,
M. De Jesus,
P. Di Stefano,
D. Drain,
L. Dumoulin,
J. Gascon,
G. Gerbier,
E. Gerlic,
C. Goldbach,
M. Goyot,
M. Gros,
J. P. Hadjout,
S. Herve,
A. Juillard,
A. de Lesquen,
M. Loidl,
J. Mallet,
S. Marnieros
, et al. (10 additional authors not shown)
Abstract:
The EDELWEISS experiment has improved its sensitivity for the direct search for WIMP dark matter. In the recoil energy range relevant for WIMP masses below 10 TeV/c2, no nuclear recoils were observed in the fiducial volume of a heat-and-ionization cryogenic Ge detector operated in the low-background environment of the Laboratoire Souterrain de Modane in the Frejus Tunnel, during an effective exp…
▽ More
The EDELWEISS experiment has improved its sensitivity for the direct search for WIMP dark matter. In the recoil energy range relevant for WIMP masses below 10 TeV/c2, no nuclear recoils were observed in the fiducial volume of a heat-and-ionization cryogenic Ge detector operated in the low-background environment of the Laboratoire Souterrain de Modane in the Frejus Tunnel, during an effective exposure of 7.4 kg.days. This result is combined with the previous EDELWEISS data to derive a limit on the cross-section for spin-independent interaction of WIMPs and nucleons as a function of WIMP mass, using standard nuclear physics and astrophysical assumptions. This limit excludes at more than 99.8%CL a WIMP candidate with a mass of 44 GeV/c2 and a cross-section of 5.4 x 10-6 pb, as reported by the DAMA collaboration. A first sample of supersymmetric models are also excluded at 90%CL.
△ Less
Submitted 17 June, 2002;
originally announced June 2002.
-
First Results of the EDELWEISS WIMP Search using a 320 g Heat-and-Ionization Ge Detector
Authors:
A. Benoit,
L. Berge,
A. Broniatowski,
B. Chambon,
M. Chapellier,
G. Chardin,
P. Charvin,
M. De Jesus,
P. Di Stefano,
D. Drain,
L. Dumoulin,
J. Gascon,
G. Gerbier,
C. Goldbach,
M. Goyot,
M. Gros,
J. P. Hadjout,
A. Juillard,
A. de Lesquen,
M. Loidl,
J. Mallet,
S. Marnieros,
O. Martineau,
N. Mirabolfathi,
L. Mosca
, et al. (6 additional authors not shown)
Abstract:
The EDELWEISS collaboration has performed a direct search for WIMP dark matter using a 320 g heat-and-ionization cryogenic Ge detector operated in a low-background environment in the Laboratoire Souterrain de Modane. No nuclear recoils are observed in the fiducial volume in the 30-200 keV energy range during an effective exposure of 4.53 kg.days. Limits for the cross-section for the spin-indepen…
▽ More
The EDELWEISS collaboration has performed a direct search for WIMP dark matter using a 320 g heat-and-ionization cryogenic Ge detector operated in a low-background environment in the Laboratoire Souterrain de Modane. No nuclear recoils are observed in the fiducial volume in the 30-200 keV energy range during an effective exposure of 4.53 kg.days. Limits for the cross-section for the spin-independent interaction of WIMPs and nucleons are set in the framework of the Minimal Supersymmetric Standard Model (MSSM). The central value of the signal reported by the experiment DAMA is excluded at 90% CL.
△ Less
Submitted 6 June, 2001;
originally announced June 2001.
-
Dark Matter Search in the EDELWEISS experiment
Authors:
A. Juillard,
A. Benoit,
L. Berge,
A. Bonnevaux,
R. Bouvier,
A. Broniatowski,
B. Chambon,
M. Chapellier,
G. Chardin,
P. Charvin,
P. Cluzel,
M. De Jesus,
P. Di Stefano,
D. Drain,
L. Dumoulin,
J. Gascon,
G. Gerbier,
C. Goldbach,
M. Goyot,
M. Gros,
J. P. Hadjout,
A. De Lesquen,
M. Loidl,
D. Loiseau,
J. Mallet
, et al. (11 additional authors not shown)
Abstract:
The EDELWEISS Dark Matter Search uses low-temperature Ge detectors with heat and ionisation read-out to identify nuclear recoils induced by elastic collisions with WIMPs from the galactic halo. Preliminary results obtained with 320g bolometers are described. After a few weeks of data taking, data accumulated with one of these detectors already allow to reach the upper part of the DAMA region. Pr…
▽ More
The EDELWEISS Dark Matter Search uses low-temperature Ge detectors with heat and ionisation read-out to identify nuclear recoils induced by elastic collisions with WIMPs from the galactic halo. Preliminary results obtained with 320g bolometers are described. After a few weeks of data taking, data accumulated with one of these detectors already allow to reach the upper part of the DAMA region. Prospects for the present run and the second stage of the experiment, EDELWEISS-II, using an innovative reversed cryostat allowing data taking with 100 detectors, are briefly described.
△ Less
Submitted 11 April, 2001;
originally announced April 2001.
-
The EDELWEISS Experiment : Status and Outlook
Authors:
J. Gascon,
A. Benoit,
A. Bonnevaux,
L. Berge,
A. Broniatowski,
B. Chambon,
M. Chapellier,
G. Chardin,
P. Charvin,
P. Cluzel,
M. De Jesus,
P. Di Stefano,
D. Drain,
L. Dumoulin,
G. Gerbier,
C. Goldbach,
M. Goyot,
M. Gros,
J. P. Hadjout S. Herve,
A. Juillard,
A. de Lesquen,
M. Loidl,
J. Mallet,
S. Marnieros,
O. Martineau
, et al. (11 additional authors not shown)
Abstract:
The EDELWEISS Dark Matter search uses low-temperature Ge detectors with heat and ionisation read- out to identify nuclear recoils induced by elastic collisions with WIMPs from the galactic halo. Results from the operation of 70 g and 320 g Ge detectors in the low-background environment of the Modane Underground Laboratory (LSM) are presented.
The EDELWEISS Dark Matter search uses low-temperature Ge detectors with heat and ionisation read- out to identify nuclear recoils induced by elastic collisions with WIMPs from the galactic halo. Results from the operation of 70 g and 320 g Ge detectors in the low-background environment of the Modane Underground Laboratory (LSM) are presented.
△ Less
Submitted 6 February, 2001; v1 submitted 25 January, 2001;
originally announced January 2001.
-
Dark Matter Search in the Edelweiss Experiment
Authors:
M. Chapellier,
A. Benoit,
L. Berge,
A. Broniatowski,
B. Chambon,
G. Chardin,
P. Charvin,
M. De Jesus,
P. Di Stefano,
D. Drain,
L. Dumoulin,
J. Gascon,
G. Gerbier,
C. Goldbach,
M. Goyot,
M. Gros,
J. P. Hadjout,
S. Herve,
A. Juillard,
A. de Lesquen,
M. Loidl,
J. Mallet,
S. Marnieros,
O. Martineau,
N. Mirabolfathi
, et al. (9 additional authors not shown)
Abstract:
Preliminary results obtained with 320g bolometers with simultaneous ionization and heat measurements are described. After a few weeks of data taking, data accumulated with one of these detectors are beginning to exclude the upper part of the DAMA region. Prospects for the present run and the second stage of the experiment, EDELWEISS-II, using an innovative reversed cryostat allowing data taking…
▽ More
Preliminary results obtained with 320g bolometers with simultaneous ionization and heat measurements are described. After a few weeks of data taking, data accumulated with one of these detectors are beginning to exclude the upper part of the DAMA region. Prospects for the present run and the second stage of the experiment, EDELWEISS-II, using an innovative reversed cryostat allowing data taking with 100 detectors, are briefly described.
△ Less
Submitted 23 February, 2001; v1 submitted 12 January, 2001;
originally announced January 2001.
-
Event categories in the EDELWEISS WIMP search experiment
Authors:
A. Benoit,
L. Berge,
A. Broniatowski,
B. Chambon,
M. Chapellier,
G. Chardin,
P. Charvin,
M. De Jesus,
P. Di Stefano,
D. Drain,
L. Dumoulin,
P. Garoche,
J. Gascon,
C. Goldbach,
M. Gros,
A. Juillard,
A. de Lesquen,
D. L'Hote,
L. Mallet,
J. Mangin,
S. Marnieros,
N. Mirabolfathi,
L. Miramonti,
L. Mosca,
X-F. Navick
, et al. (6 additional authors not shown)
Abstract:
Four categories of events have been identified in the EDELWEISS-I dark matter experiment using germanium cryogenic detectors measuring simultaneously charge and heat signals. These categories of events are interpreted as electron and nuclear interactions occurring in the volume of the detector, and electron and nuclear interactions occurring close to the surface of the detectors(10-20 mu-m of th…
▽ More
Four categories of events have been identified in the EDELWEISS-I dark matter experiment using germanium cryogenic detectors measuring simultaneously charge and heat signals. These categories of events are interpreted as electron and nuclear interactions occurring in the volume of the detector, and electron and nuclear interactions occurring close to the surface of the detectors(10-20 mu-m of the surface). We discuss the hypothesis that low energy surface nuclear recoils,which seem to have been unnoticed by previous WIMP searches, may provide an interpretation of the anomalous events recorded by the UKDMC and Saclay NaI experiments. The present analysis points to the necessity of taking into account surface nuclear and electron recoil interactions for a reliable estimate of background rejection factors.
△ Less
Submitted 24 February, 2000;
originally announced February 2000.