-
Superconducting boron doped nanocrystalline diamond microwave coplanar resonator
Authors:
Jerome A. Cuenca,
Thomas Brien,
Soumen Mandal,
Scott Manifold,
Simon Doyle,
Adrian Porch,
Georgina M. Klemencic,
Oliver A. Williams
Abstract:
A superconducting boron doped nanocrystalline diamond (B-NCD) coplanar waveguide resonator (CPR) is presented for kinetic inductance ($L_k$) and penetration depth ($λ_{\rm{L}}$) measurements at microwave frequencies of 0.4 to 1.2 GHz and at temperatures below 3 K. Using a simplified effective medium CPR approach, this work demonstrates that thin granular B-NCD films ($t\approx $ 500 nm) on Si have…
▽ More
A superconducting boron doped nanocrystalline diamond (B-NCD) coplanar waveguide resonator (CPR) is presented for kinetic inductance ($L_k$) and penetration depth ($λ_{\rm{L}}$) measurements at microwave frequencies of 0.4 to 1.2 GHz and at temperatures below 3 K. Using a simplified effective medium CPR approach, this work demonstrates that thin granular B-NCD films ($t\approx $ 500 nm) on Si have a large penetration depth ($λ_{\rm{L}}\approx 4.3$ to 4.4 $μ$m), and therefore an associated high kinetic inductance ($L_{k,\square} \approx $ 670 to 690 pH/$\square$). These values are much larger than those typically obtained for films on single crystal diamond which is likely due to the significant granularity of the nanocrystalline films. Based on the measured Q factors of the structure, the calculated surface resistance in this frequency range is found to be as low as $\approx$ 2 to 4 $μΩ$ at $T<2$ K, demonstrating the potential for granular B-NCD for high quality factor superconducting microwave resonators and highly sensitive kinetic inductance detectors.
△ Less
Submitted 27 February, 2022;
originally announced February 2022.
-
Observation of Time-Crystalline Eigenstate Order on a Quantum Processor
Authors:
Xiao Mi,
Matteo Ippoliti,
Chris Quintana,
Ami Greene,
Zijun Chen,
Jonathan Gross,
Frank Arute,
Kunal Arya,
Juan Atalaya,
Ryan Babbush,
Joseph C. Bardin,
Joao Basso,
Andreas Bengtsson,
Alexander Bilmes,
Alexandre Bourassa,
Leon Brill,
Michael Broughton,
Bob B. Buckley,
David A. Buell,
Brian Burkett,
Nicholas Bushnell,
Benjamin Chiaro,
Roberto Collins,
William Courtney,
Dripto Debroy
, et al. (80 additional authors not shown)
Abstract:
Quantum many-body systems display rich phase structure in their low-temperature equilibrium states. However, much of nature is not in thermal equilibrium. Remarkably, it was recently predicted that out-of-equilibrium systems can exhibit novel dynamical phases that may otherwise be forbidden by equilibrium thermodynamics, a paradigmatic example being the discrete time crystal (DTC). Concretely, dyn…
▽ More
Quantum many-body systems display rich phase structure in their low-temperature equilibrium states. However, much of nature is not in thermal equilibrium. Remarkably, it was recently predicted that out-of-equilibrium systems can exhibit novel dynamical phases that may otherwise be forbidden by equilibrium thermodynamics, a paradigmatic example being the discrete time crystal (DTC). Concretely, dynamical phases can be defined in periodically driven many-body localized systems via the concept of eigenstate order. In eigenstate-ordered phases, the entire many-body spectrum exhibits quantum correlations and long-range order, with characteristic signatures in late-time dynamics from all initial states. It is, however, challenging to experimentally distinguish such stable phases from transient phenomena, wherein few select states can mask typical behavior. Here we implement a continuous family of tunable CPHASE gates on an array of superconducting qubits to experimentally observe an eigenstate-ordered DTC. We demonstrate the characteristic spatiotemporal response of a DTC for generic initial states. Our work employs a time-reversal protocol that discriminates external decoherence from intrinsic thermalization, and leverages quantum typicality to circumvent the exponential cost of densely sampling the eigenspectrum. In addition, we locate the phase transition out of the DTC with an experimental finite-size analysis. These results establish a scalable approach to study non-equilibrium phases of matter on current quantum processors.
△ Less
Submitted 11 August, 2021; v1 submitted 28 July, 2021;
originally announced July 2021.
-
MUSCAT focal plane verification
Authors:
M. Tapia,
P. A. R. Ade,
P. S. Barry,
T. L. R. Brien,
E. Castillo-Domínguez,
D. Ferrusca,
V. Gómez-Rivera,
P. Hargrave,
J. L. Hernández Rebollar,
A. Hornsby,
D. H. Hughes,
J. M. Jáuregui-García,
P. Mauskopf,
D. Murias,
A. Papageorgiou,
E. Pascale,
A. Pérez,
S. Rowe,
M. W. L. Smith,
C. Tucker,
M. Velázquez,
S. Ventura,
S. Doyle
Abstract:
The Mexico-UK Submillimetre Camera for Astronomy (MUSCAT) is the second-generation large-format continuum camera operating in the 1.1 mm band to be installed on the 50-m diameter Large Millimeter Telescope (LMT) in Mexico. The focal plane of the instrument is made up of 1458 horn coupled lumped-element kinetic inductance detectors (LEKID) divided equally into six channels deposited on three silico…
▽ More
The Mexico-UK Submillimetre Camera for Astronomy (MUSCAT) is the second-generation large-format continuum camera operating in the 1.1 mm band to be installed on the 50-m diameter Large Millimeter Telescope (LMT) in Mexico. The focal plane of the instrument is made up of 1458 horn coupled lumped-element kinetic inductance detectors (LEKID) divided equally into six channels deposited on three silicon wafers. Here we present the preliminary results of the complete characterisation in the laboratory of the MUSCAT focal plane. Through the instrument's readout system, we perform frequency sweeps of the array to identify the resonance frequencies, and continuous timestream acquisitions to measure and characterise the intrinsic noise and 1/f knee of the detectors. Subsequently, with a re-imaging lens and a black body point source, the beams of every detector are mapped, obtaining a mean FWHM size of $\sim$3.27 mm, close to the expected 3.1 mm. Then, by varying the intensity of a beam filling black body source, we measure the responsivity and noise power spectral density (PSD) for each detector under an optical load of 300 K, obtaining the noise equivalent power (NEP), with which we verify that the majority of the detectors are photon noise limited. Finally, using a Fourier Transform Spectrometer (FTS), we measure the spectral response of the instrument, which indicate a bandwidth of 1.0--1.2 mm centred on 1.1 mm, as expected.
△ Less
Submitted 9 December, 2020;
originally announced December 2020.
-
Pre-deployment Verification and Predicted Map** Speed of MUSCAT
Authors:
T. L. R. Brien,
P. A. R. Ade,
P. S. Barry,
E. Castillo-Domínguez,
D. Ferrusca,
V. Gómez-Rivera,
P. Hargrave,
J. L. Hernández Rebollar,
A. Hornsby,
D. H. Hughes,
J. M. Jáuregui-García,
P. Mauskopf,
D. Murias,
A. Papageorgiou,
E. Pascale,
A. Pérez,
S. Rowe,
M. W. L. Smith,
M. Tapia,
C. Tucker,
M. Velázquez,
S. Ventura,
S. Doyle
Abstract:
The Mexico-UK Submillimetre Camera for AsTronomy (MUSCAT) is a 1.1 mm receiver consisting of 1,500 lumped-element kinetic inductance detectors (LEKIDs) for the Large Millimeter Telescope (LMT; Volcán Sierra Negra in Puebla, México). MUSCAT utilises the maximum field of view of the LMT's upgraded 50-metre primary mirror and is the first México-UK collaboration to deploy a millimetre/sub-mm receiver…
▽ More
The Mexico-UK Submillimetre Camera for AsTronomy (MUSCAT) is a 1.1 mm receiver consisting of 1,500 lumped-element kinetic inductance detectors (LEKIDs) for the Large Millimeter Telescope (LMT; Volcán Sierra Negra in Puebla, México). MUSCAT utilises the maximum field of view of the LMT's upgraded 50-metre primary mirror and is the first México-UK collaboration to deploy a millimetre/sub-mm receiver on the Large Millimeter Telescope. Using a simplistic simulator, we estimate a predicted map** speed for MUSCAT by combining the measured performance of MUSCAT with the observed sky conditions at the LMT. We compare this to a previously calculated bolometric-model map** speed and find that our map** speed is in good agreement when this is scaled by a previously reported empirical factor. Through this simulation we show that signal contamination due to sky fluctuations can be effectively removed through the use of principle component analysis. We also give an overview of the instrument design and explain how this design allows for MUSCAT to be upgraded and act as an on-sky demonstration testbed for novel technologies after the facility-class TolTEC receiver comes online.
△ Less
Submitted 9 December, 2020;
originally announced December 2020.
-
MUSCAT: The Mexico-UK Sub-Millimetre Camera for AsTronomy
Authors:
Thomas L. R. Brien,
Peter A. R. Ade,
Peter S. Barry,
Edgar Castillo-Domìnguez,
Daniel Ferrusca,
Thomas Gascard,
Victor Gómez,
Peter C. Hargrave,
Amber L. Hornsby,
David Hughes,
Enzo Pascale,
Josie D. A. Parrianen,
Abel Perez,
Sam Rowe,
Carole Tucker,
Salvador Ventura González,
Simon M. Doyle
Abstract:
The Mexico-UK Sub-millimetre Camera for AsTronomy (MUSCAT) is a large-format, millimetre-wave camera consisting of 1,500 background-limited lumped-element kinetic inductance detectors (LEKIDs) scheduled for deployment on the Large Millimeter Telescope (Volcán Sierra Negra, Mexico) in 2018. MUSCAT is designed for observing at 1.1 mm and will utilise the full 40' field of view of the LMTs upgraded 5…
▽ More
The Mexico-UK Sub-millimetre Camera for AsTronomy (MUSCAT) is a large-format, millimetre-wave camera consisting of 1,500 background-limited lumped-element kinetic inductance detectors (LEKIDs) scheduled for deployment on the Large Millimeter Telescope (Volcán Sierra Negra, Mexico) in 2018. MUSCAT is designed for observing at 1.1 mm and will utilise the full 40' field of view of the LMTs upgraded 50-m primary mirror. In its primary role, MUSCAT is designed for high-resolution follow-up surveys of both galactic and extra-galactic sub-mm sources identified by Herschel. MUSCAT is also designed to be a technology demonstrator that will provide the first on-sky demonstrations of novel design concepts such as horn-coupled LEKID arrays and closed continuous cycle miniature dilution refrigeration.
Here we describe some of the key design elements of the MUSCAT instrument such as the novel use of continuous sorption refrigerators and a miniature dilutor for continuous 100-mK cooling of the focal plane, broadband optical coupling to Aluminium LEKID arrays using waveguide chokes and anti-reflection coating materials as well as with the general mechanical and optical design of MUSCAT. We explain how MUSCAT is designed to be simple to upgrade and the possibilities for changing the focal plane unit that allows MUSCAT to act as a demonstrator for other novel technologies such as multi-chroic polarisation sensitive pixels and on-chip spectrometry in the future. Finally, we will report on the current status of MUSCAT's commissioning.
△ Less
Submitted 23 July, 2018;
originally announced July 2018.
-
Mexico-UK Sub-millimeter Camera for AsTronomy
Authors:
Edgar Castillo-Dominguez,
Peter Ade,
Peter Barry,
Thom Brien,
Simon Doyle,
Daniel Ferrusca,
Victor Gomez-Rivera,
Peter Hargrave,
Amber Hornsby,
David Hughes,
Phillip Mauskopf,
Paul Moseley,
Enzo Pascale,
Abel Perez-Fajardo,
Giampaolo Pisano,
Samuel Rowe,
Carole Tucker,
Miguel Velazquez
Abstract:
MUSCAT is a large format mm-wave camera scheduled for installation on the Large Millimeter Telescope Alfonso Serrano (LMT) in 2018. The MUSCAT focal plane is based on an array of horn coupled lumped-element kinetic inductance detectors optimised for coupling to the 1.1mm atmospheric window. The detectors are fed with fully baffled reflective optics to minimize stray-light contamination. This combi…
▽ More
MUSCAT is a large format mm-wave camera scheduled for installation on the Large Millimeter Telescope Alfonso Serrano (LMT) in 2018. The MUSCAT focal plane is based on an array of horn coupled lumped-element kinetic inductance detectors optimised for coupling to the 1.1mm atmospheric window. The detectors are fed with fully baffled reflective optics to minimize stray-light contamination. This combination will enable background-limited performance at 1.1 mm across the full 4 arcminute field-of-view of the LMT. The easily accessible focal plane will be cooled to 100 mK with a new closed cycle miniature dilution refrigerator that permits fully continuous operation. The MUSCAT instrument will demonstrate the science capabilities of the LMT through two relatively short science programmes to provide high resolution follow-up surveys of Galactic and extra-galactic sources previously observed with the Herschel space observatory, after the initial observing campaigns. In this paper, we will provide an overview of the overall instrument design as well as an update on progress and scheduled installation on the LMT.
△ Less
Submitted 27 June, 2018;
originally announced June 2018.
-
A Continuous 100-mK Helium-Light Cooling System for MUSCAT on the LMT
Authors:
T. L. R. Brien,
E. Castillo-Dominguez,
S. Chase,
S. M. Doyle
Abstract:
The MUSCAT instrument is a large-format camera planned for installation on the Large Millimeter Telescope (LMT) in 2018. MUSCAT requires continuous cooling of several large-volume stages to sub-Kelvin temperatures, with the focal plane cooled to 100 mK. Through the use of continuous sorption coolers and a miniature dilution refrigerator, the MUSCAT project can fulfil its cryogenic requirements at…
▽ More
The MUSCAT instrument is a large-format camera planned for installation on the Large Millimeter Telescope (LMT) in 2018. MUSCAT requires continuous cooling of several large-volume stages to sub-Kelvin temperatures, with the focal plane cooled to 100 mK. Through the use of continuous sorption coolers and a miniature dilution refrigerator, the MUSCAT project can fulfil its cryogenic requirements at a fraction of the cost and space required for conventional dilution systems. Our design is a helium-light system, using a total of only 9 litres of helium-3 across several continuous cooling systems, cooling from 4 K to 100 mK. Here we describe the operation of both the continuous sorption and the miniature dilution refrigerator systems used in this system, along with the overall thermal design and budgeting of MUSCAT. MUSCAT will represent the first deployment of these new technologies in a science-grade instrument and will prove the concept as a viable option for future large-scale experiments such as CMB-S4.
△ Less
Submitted 23 July, 2018; v1 submitted 23 January, 2018;
originally announced January 2018.
-
Multi-Epoch Radio Imaging of gamma-ray Nova V959 Mon
Authors:
F. Healy,
T. J. O Brien,
R. Beswick,
A. Avison,
M. K. Argo
Abstract:
V959 Mon (Nova Mon 2012) was first detected by the Fermi Large Area Telescope in June 2012, as a transient gamma-ray source. Subsequent optical observations showed that this gamma-ray emission was due to a classical nova explosion. Multi-frequency observations of V959 Mon with the VLA between June and September 2012 revealed dramatic brightening, and a spectrum that steepened with increasing frequ…
▽ More
V959 Mon (Nova Mon 2012) was first detected by the Fermi Large Area Telescope in June 2012, as a transient gamma-ray source. Subsequent optical observations showed that this gamma-ray emission was due to a classical nova explosion. Multi-frequency observations of V959 Mon with the VLA between June and September 2012 revealed dramatic brightening, and a spectrum that steepened with increasing frequency. High resolution radio images of V959 Mon using e-MERLIN are presented here, at six epochs between September 2012 and February 2014 which show morphological evolution of the source. While early e-MERLIN observations of V959 Mon show an east-west elonga- tion in the ejecta morphology, subsequent observations suggest that the ejecta become elongated in the north-south direction. Our high-resolution observations of this sur- prising evolution in the structure of V959 Mon can assist us in further understanding the behaviour and morphology of nova ejecta.
△ Less
Submitted 23 October, 2017;
originally announced October 2017.
-
Optical Response of Strained- and Unstrained-Silicon Cold-Electron Bolometers
Authors:
T. L. R. Brien,
P. A. R. Ade,
P. S. Barry,
C. J. Dunscombe,
D. R. Leadley,
D. V. Morozov,
M. Myronov,
E. H. C. Parker,
M. J. Prest,
M. Prunnila,
R. V. Sudiwala,
T. E. Whall,
P. D. Mauskopf
Abstract:
We describe the optical characterisation of two silicon cold-electron bolometers each consisting of a small ($32 \times 14~\mathrm{μm}$) island of degenerately doped silicon with superconducting aluminium contacts. Radiation is coupled into the silicon absorber with a twin-slot antenna designed to couple to 160-GHz radiation through a silicon lens.The first device has a highly doped silicon absorb…
▽ More
We describe the optical characterisation of two silicon cold-electron bolometers each consisting of a small ($32 \times 14~\mathrm{μm}$) island of degenerately doped silicon with superconducting aluminium contacts. Radiation is coupled into the silicon absorber with a twin-slot antenna designed to couple to 160-GHz radiation through a silicon lens.The first device has a highly doped silicon absorber, the second has a highly doped strained-silicon absorber.Using a novel method of cross-correlating the outputs from two parallel amplifiers, we measure noise-equivalent powers of $3.0 \times 10^{-16}$ and $6.6 \times 10^{-17}~\mathrm{W\,Hz^{-1/2}}$ for the control and strained device, respectively, when observing radiation from a 77-K source. In the case of the strained device, the noise-equivalent power is limited by the photon noise.
△ Less
Submitted 10 March, 2016;
originally announced March 2016.
-
A passive THz video camera based on lumped element kinetic inductance detectors
Authors:
Sam Rowe,
Enzo Pascale,
Simon Doyle,
Chris Dunscombe,
Peter Hargrave,
Andreas Papageorgio,
Ken Wood,
Peter A. R. Ade,
Peter Barry,
Aurélien Bideaud,
Tom Brien,
Chris Dodd,
William Grainger,
Julian House,
Philip Mauskopf,
Paul Moseley,
Locke Spencer,
Rashmi Sudiwala,
Carole Tucker,
Ian Walker
Abstract:
We have developed a passive 350 GHz (850 μm) video-camera to demonstrate lumped element kinetic inductance detectors (LEKIDs) -- designed originally for far-infrared astronomy -- as an option for general purpose terrestrial terahertz imaging applications. The camera currently operates at a quasi-video frame rate of 2 Hz with a noise equivalent temperature difference per frame of $\sim$0.1 K, which…
▽ More
We have developed a passive 350 GHz (850 μm) video-camera to demonstrate lumped element kinetic inductance detectors (LEKIDs) -- designed originally for far-infrared astronomy -- as an option for general purpose terrestrial terahertz imaging applications. The camera currently operates at a quasi-video frame rate of 2 Hz with a noise equivalent temperature difference per frame of $\sim$0.1 K, which is close to the background limit. The 152 element superconducting LEKID array is fabricated from a simple 40 nm aluminum film on a silicon dielectric substrate and is read out through a single microwave feedline with a cryogenic low noise amplifier and room temperature frequency domain multiplexing electronics.
△ Less
Submitted 18 November, 2015;
originally announced November 2015.
-
A Strained Silicon Cold Electron Bolometer using Schottky Contacts
Authors:
T. L. R. Brien,
P. A. R. Ade,
P. S. Barry,
C. Dunscombe,
D. R. Leadley,
D. V. Morozov,
M. Myronov,
E. H. C. Parker,
M. Prunnila,
M. J. Prest,
R. V. Sudiwala,
T. E. Whall,
P. D. Mauskopf
Abstract:
We describe optical characterisation of a Strained Silicon Cold Electron Bolometer (CEB), operating on a $350~\mathrm{mK}$ stage, designed for absorption of millimetre-wave radiation. The silicon Cold Electron Bolometer utilises Schottky contacts between a superconductor and an n++ doped silicon island to detect changes in the temperature of the charge carriers in the silicon, due to variations in…
▽ More
We describe optical characterisation of a Strained Silicon Cold Electron Bolometer (CEB), operating on a $350~\mathrm{mK}$ stage, designed for absorption of millimetre-wave radiation. The silicon Cold Electron Bolometer utilises Schottky contacts between a superconductor and an n++ doped silicon island to detect changes in the temperature of the charge carriers in the silicon, due to variations in absorbed radiation. By using strained silicon as the absorber, we decrease the electron-phonon coupling in the device and increase the responsivity to incoming power. The strained silicon absorber is coupled to a planar aluminium twin-slot antenna designed to couple to $160~\mathrm{GHz}$ and that serves as the superconducting contacts. From the measured optical responsivity and spectral response, we calculate a maximum optical efficiency of $50~\%$ for radiation coupled into the device by the planar antenna and an overall noise equivalent power (NEP), referred to absorbed optical power, of $1.1 \times 10^{-16}~\mathrm{\mbox{W Hz}^{-1/2}}$ when the detector is observing a $300~\mathrm{K}$ source through a $4~\mathrm{K}$ throughput limiting aperture. Even though this optical system is not optimised we measure a system noise equivalent temperature difference (NETD) of $6~\mathrm{\mbox{mK Hz}^{-1/2}}$. We measure the noise of the device using a cross-correlation of time stream data measured simultaneously with two junction field-effect transistor (JFET) amplifiers, with a base correlated noise level of $300~\mathrm{\mbox{pV Hz}^{-1/2}}$ and find that the total noise is consistent with a combination of photon noise, current shot noise and electron-phonon thermal noise.
△ Less
Submitted 31 July, 2014; v1 submitted 8 July, 2014;
originally announced July 2014.
-
A relativistic jetted outburst from a massive black hole fed by a tidally disrupted star
Authors:
Joshua S. Bloom,
Dimitrios Giannios,
Brian D. Metzger,
S. Bradley Cenko,
Daniel A. Perley,
Nathaniel R. Butler,
Nial R. Tanvir,
Andrew J. Levan,
Paul T. O' Brien,
Linda E. Strubbe,
Fabio De Colle,
Enrico Ramirez-Ruiz,
William H. Lee,
Sergei Nayakshin,
Eliot Quataert,
Andrew R. King,
Antonino Cucchiara,
James Guillochon,
Geoffrey C. Bower,
Andrew S. Fruchter,
Adam N. Morgan,
Alexander J. van der Horst
Abstract:
While gas accretion onto some massive black holes (MBHs) at the centers of galaxies actively powers luminous emission, the vast majority of MBHs are considered dormant. Occasionally, a star passing too near a MBH is torn apart by gravitational forces, leading to a bright panchromatic tidal disruption flare (TDF). While the high-energy transient Swift J164449.3+573451 ("Sw 1644+57") initially displ…
▽ More
While gas accretion onto some massive black holes (MBHs) at the centers of galaxies actively powers luminous emission, the vast majority of MBHs are considered dormant. Occasionally, a star passing too near a MBH is torn apart by gravitational forces, leading to a bright panchromatic tidal disruption flare (TDF). While the high-energy transient Swift J164449.3+573451 ("Sw 1644+57") initially displayed none of the theoretically anticipated (nor previously observed) TDF characteristics, we show that the observations (Levan et al. 2011) suggest a sudden accretion event onto a central MBH of mass ~10^6-10^7 solar masses. We find evidence for a mildly relativistic outflow, jet collimation, and a spectrum characterized by synchrotron and inverse Compton processes; this leads to a natural analogy of Sw 1644+57 with a smaller-scale blazar. The phenomenologically novel Sw 1644+57 thus connects the study of TDFs and active galaxies, opening a new vista on disk-jet interactions in BHs and magnetic field generation and transport in accretion systems.
△ Less
Submitted 16 April, 2011;
originally announced April 2011.
-
Soft X-ray emission lines in the afterglow spectrum of GRB 011211:- a detailed XMM-Newton analysis
Authors:
J. N. Reeves,
D. Watson,
J. P. Osborne,
K. A. Pounds,
P. T. O Brien
Abstract:
We report on an XMM-Newton observation of the X-ray afterglow of the Gamma Ray Burst GRB 011211, originally detected by Beppo-SAX on 11th December 2001. The early afterglow spectrum obtained by XMM-Newton, observed 11 hours after the initial burst, appeared to reveal decaying H-like K emission lines of Mg, Si, S, Ar and Ca, arising in enriched material with an outflow velocity of order 0.1c (Ree…
▽ More
We report on an XMM-Newton observation of the X-ray afterglow of the Gamma Ray Burst GRB 011211, originally detected by Beppo-SAX on 11th December 2001. The early afterglow spectrum obtained by XMM-Newton, observed 11 hours after the initial burst, appeared to reveal decaying H-like K emission lines of Mg, Si, S, Ar and Ca, arising in enriched material with an outflow velocity of order 0.1c (Reeves et al. 2002). This was attributed to matter ejected from a massive stellar progenitor occurring shortly before the burst itself. Here, we present a detailed re-analysis of the XMM-Newton EPIC observations of GRB 011211. In particular, we show that the detection of the soft X-ray line emission appears robust, regardless of detector background, calibration, spectral binning, or the spectral model that is assumed. We demonstrate that thermal emission, from an optically thin plasma, is the most plausible model that can account for the soft X-ray emission, which appears to be the case for at least two burst afterglow spectra observed by XMM-Newton. The X-ray spectrum of GRB 011211 evolves with time over the first 12 ksec of the XMM-Newton observation, the observations suggest that thermal emission dominates the early afterglow spectrum, whilst a power-law component dominates the latter stages. Finally we estimate the mass of the ejected material in GRB 011211 to be of the order 4-20 solar masses.
△ Less
Submitted 27 June, 2002;
originally announced June 2002.