Skip to main content

Showing 1–50 of 108 results for author: Breskin, A

.
  1. arXiv:2312.14663  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    First observation of liquid xenon electroluminescence with a Microstrip Plate

    Authors: G. Martinez-Lema, V. Chepel, A. Roy, A. Breskin

    Abstract: We report on the first observation of electroluminescence amplification with a Microstrip Plate immersed in liquid xenon. The electroluminescence of the liquid, induced by alpha-particles, was observed in an intense non-uniform electric field in the vicinity of 8-$μ$m narrow anode strips interlaced with wider cathode ones, deposited on the same side of a glass substrate. The electroluminescence yi… ▽ More

    Submitted 23 January, 2024; v1 submitted 22 December, 2023; originally announced December 2023.

    Comments: 17 pages, 14 figures, prepared for submission to JINST

  2. arXiv:2312.06809  [pdf, other

    physics.ins-det

    Cryogenic RPWELL: a novel charge-readout element for dual-phase argon TPCs

    Authors: A. Tesi, S. Leardini, L. Moleri, M. Morales, D. Gonzalez-Diaz, A. Jash, A. Breskin, S. Bressler

    Abstract: The first operation of a cryogenic Resistive Plate WELL (RPWELL) detector in the saturated vapor of liquid argon is reported. The RPWELL detector was composed of a Thick Gas Electron Multiplier (THGEM) electrode coupled to a metallic anode via Fe$_2$O$_3$/YSZ ceramics (Fe$_2$O$_3$ in weight equal to 75$\%$), with tunable bulk resistivity in the range 10$^{9}$ - 10$^{12}$ $Ω\cdot$cm. The detector w… ▽ More

    Submitted 11 December, 2023; originally announced December 2023.

  3. arXiv:2308.08314  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Electron transfer efficiency in liquid xenon across THGEM holes

    Authors: G. Martínez-Lema, A. Roy, A. Breskin, L. Arazi

    Abstract: Dual-phase liquid-xenon time projection chambers (LXe TPCs) deploying a few tonnes of liquid are presently leading the search for WIMP dark matter. Scaling these detectors to 10-fold larger fiducial masses, while improving their sensitivity to low-mass WIMPs presents difficult challenges in detector design. Several groups are considering a departure from current schemes, towards either single-phas… ▽ More

    Submitted 9 November, 2023; v1 submitted 16 August, 2023; originally announced August 2023.

  4. arXiv:2307.02343  [pdf, other

    physics.ins-det

    The cryogenic RWELL: a stable charge multiplier for dual-phase liquid-argon detectors

    Authors: A. Tesi, S. Leardini, L. Moleri, D. Gonzalez-Diaz, A. Jash, A. Breskin, S. Bressler

    Abstract: The operation of a cryogenic Resistive WELL (RWELL) in liquid argon vapor is reported for the first time. It comprises a Thick Gas Electron Multiplier (THGEM) structure coupled to a resistive Diamond-Like Carbon (DLC) anode deposited on an insulating substrate. The multiplier was operated at cryogenic temperature (90~K, 1.2~bar) in saturated argon vapor and characterized in terms of charge gain an… ▽ More

    Submitted 26 September, 2023; v1 submitted 5 July, 2023; originally announced July 2023.

  5. arXiv:2306.16340  [pdf, other

    physics.ins-det

    Cosmogenic background simulations for the DARWIN observatory at different underground locations

    Authors: M. Adrover, L. Althueser, B. Andrieu, E. Angelino, J. R. Angevaare, B. Antunovic, E. Aprile, M. Babicz, D. Bajpai, E. Barberio, L. Baudis, M. Bazyk, N. Bell, L. Bellagamba, R. Biondi, Y. Biondi, A. Bismark, C. Boehm, A. Breskin, E. J. Brookes, A. Brown, G. Bruno, R. Budnik, C. Capelli, J. M. R. Cardoso , et al. (158 additional authors not shown)

    Abstract: Xenon dual-phase time projections chambers (TPCs) have proven to be a successful technology in studying physical phenomena that require low-background conditions. With 40t of liquid xenon (LXe) in the TPC baseline design, DARWIN will have a high sensitivity for the detection of particle dark matter, neutrinoless double beta decay ($0νββ$), and axion-like particles (ALPs). Although cosmic muons are… ▽ More

    Submitted 28 June, 2023; originally announced June 2023.

  6. arXiv:2304.04044  [pdf, other

    physics.ins-det hep-ex

    Novel resistive charge-multipliers for dual-phase LAr-TPCs: towards stable operation at higher gains

    Authors: A. Tesi, L. Moleri, S. Leardini, A. Breskin, D. Gonzalez-Diaz, L. Olano-Vegas, A. Jash, S. Bressler

    Abstract: Cryogenic versions of Resistive WELL (RWELL) and Resistive Plate WELL (RPWELL) detectors have been developed, aimed at stable avalanche multiplication of ionization electrons in dual-phase TPCs. In the RWELL, a thin resistive layer deposited on top of an insulator is inserted in between the electron multiplier (THGEM) and the readout anode; in the RPWELL, a resistive plate is directly coupled to t… ▽ More

    Submitted 21 May, 2023; v1 submitted 8 April, 2023; originally announced April 2023.

  7. arXiv:2301.12990  [pdf, other

    physics.ins-det astro-ph.IM

    First results on FHM -- a Floating Hole Multiplier

    Authors: V. Chepel, G. Martinez-Lema, A. Roy, A. Breskin

    Abstract: A proof of principle of a novel concept for event recording in dual-phase liquid xenon detectors -- the Floating Hole Multiplier (FHM) -- is presented. It is shown that a standard Thick Gaseous Electron Multiplier (THGEM), freely floating on the liquid xenon surface permits extraction of electrons from the liquid to the gas. Secondary scintillation induced by the extracted electrons in the THGEM h… ▽ More

    Submitted 30 January, 2023; originally announced January 2023.

    Comments: 12 pages

  8. Diamond-like carbon coatings for cryogenic operation of particle detectors

    Authors: Sara Leardini, Yi Zhou, Andrea Tesi, Miguel Morales, Diego González-Díaz, Amos Breskin, Shikma Bressler, Luca Moleri, Vladimir Peskov

    Abstract: Characterization of diamond-like carbon (DLC) coatings at cryogenic temperatures (down to 77 K) is presented, covering the electrical resistivity range of practical interest to gaseous and liquid particle instrumentation: 10^-1-10^5 Mohm/sq. The good behaviour observed in terms of linearity, surface uniformity and stability with time and transported charge add to other well-known characteristics l… ▽ More

    Submitted 22 January, 2023; v1 submitted 30 September, 2022; originally announced September 2022.

    Comments: 22 pages, 14 figures

  9. arXiv:2208.12846  [pdf, other

    physics.ins-det hep-ex

    Test-Beam and Simulation Studies Towards RPWELL-based DHCAL

    Authors: Dan Shaked-Renous, Fernando Domingues Amaro, Purba Bhattacharya, Amos Breskin, Maximilien Chefdeville, Cyril Drancourt, Theo Geralis, Yannis Karyotakis, Luca Moleri, Andrea Tesi, Maxim Titov, Joao Veloso, Guillaum Vouters, Shikma Bressler

    Abstract: Digital Hadronic Calorimeters (DHCAL) were suggested for future Colliders as part of the particle-flow concept. Though studied mainly with Resistive Plate Chambers (RPC), studies focusing on Micro-Pattern Gaseous Detector (MPGD)-based sampling elements have shown the potential advantages; they can be operated with environmental friendly gases and reach similar detection efficiency at lower average… ▽ More

    Submitted 7 October, 2022; v1 submitted 26 August, 2022; originally announced August 2022.

  10. arXiv:2206.04445  [pdf, other

    stat.ME

    Bridged treatment comparisons: an illustrative application in HIV treatment

    Authors: Paul N Zivich, Stephen R Cole, Jessie K Edwards, Bonnie E Shook-Sa, Alexander Breskin, Michael G Hudgens

    Abstract: Comparisons of treatments, interventions, or exposures are of central interest in epidemiology, but direct comparisons are not always possible due to practical or ethical reasons. Here, we detail a fusion approach to compare treatments across studies. The motivating example entails comparing the risk of the composite outcome of death, AIDS, or greater than a 50% CD4 cell count decline in people wi… ▽ More

    Submitted 22 August, 2023; v1 submitted 9 June, 2022; originally announced June 2022.

    Comments: 21 pages, 3 figures, 5 tables

  11. arXiv:2203.02309  [pdf, other

    physics.ins-det astro-ph.CO hep-ex nucl-ex

    A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics

    Authors: J. Aalbers, K. Abe, V. Aerne, F. Agostini, S. Ahmed Maouloud, D. S. Akerib, D. Yu. Akimov, J. Akshat, A. K. Al Musalhi, F. Alder, S. K. Alsum, L. Althueser, C. S. Amarasinghe, F. D. Amaro, A. Ames, T. J. Anderson, B. Andrieu, N. Angelides, E. Angelino, J. Angevaare, V. C. Antochi, D. Antón Martin, B. Antunovic, E. Aprile, H. M. Araújo , et al. (572 additional authors not shown)

    Abstract: The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut… ▽ More

    Submitted 4 March, 2022; originally announced March 2022.

    Comments: 77 pages, 40 figures, 1262 references

    Report number: INT-PUB-22-003

    Journal ref: J. Phys. G: Nucl. Part. Phys. 50 (2023) 013001

  12. arXiv:2203.01774  [pdf

    physics.ins-det astro-ph.IM hep-ex

    Novel electron and photon recording concepts in noble-liquid detectors

    Authors: Amos Breskin

    Abstract: We present several novel ionization-electron and scintillation-photon recording concepts in noble-liquid detectors, for future applications in particle and astroparticle physics and in other fields. These involve both single- and dual-phase detector configurations with combined electroluminescence and small charge multiplication in gas and liquid media.

    Submitted 9 May, 2022; v1 submitted 3 March, 2022; originally announced March 2022.

    Comments: 32 pages, 15 figures, to be published in JINST

  13. Bubble dynamics in Liquid Hole Multipliers

    Authors: A. Tesi, E. Segre, S. Leardini, A. Breskin, S. Kapishnikov, L. Moleri, D. Vartsky, S. Bressler

    Abstract: In bubble-assisted Liquid HoleMultipliers(LHM), developed for noble-liquid radiation detectors, the stability of the bubble and the electro-mechanical properties of the liquid-to-gas interface play a dominant role in the detector performance. A model is proposed to evaluate the static equilibrium configurations of a bubble sustained underneath a perforated electrode immersed in a liquid. For the f… ▽ More

    Submitted 26 July, 2021; originally announced August 2021.

    Comments: 25 pages, 15 figures

  14. Single Electron Spectra in RPWELL-based detectors

    Authors: Purba Bhattacharya, Andrea Tesi, Dan Shaked-Renous, Luca Moleri, Amos Breskin, Shikma Bressler

    Abstract: Single-electron avalanche distributions in gaseous multipliers affect their efficient detection and that of single UV-photons. In this work, we investigated the shape of single-photo-electron spectra in single- and double-stage Resistive Plate WELL (RPWELL) detector configurations, operated in $\mathrm{Ne/CH_{4}}$ and $\mathrm{Ar/CH_{4}}$. Discharge-free operation was reached over a broad dynamic… ▽ More

    Submitted 21 June, 2021; v1 submitted 5 January, 2021; originally announced January 2021.

    Journal ref: JINST 16 P05004 (2021)

  15. arXiv:2006.03114  [pdf, other

    physics.ins-det astro-ph.SR hep-ex hep-ph

    Solar Neutrino Detection Sensitivity in DARWIN via Electron Scattering

    Authors: J. Aalbers, F. Agostini, S. E. M. Ahmed Maouloud, M. Alfonsi, L. Althueser, F. Amaro, J. Angevaare, V. C. Antochi, B. Antunovic, E. Aprile, L. Arazi, F. Arneodo, M. Balzer, L. Baudis, D. Baur, M. L. Benabderrahmane, Y. Biondi, A. Bismark, C. Bourgeois, A. Breskin, P. A. Breur, A. Brown, E. Brown, S. Brünner, G. Bruno , et al. (141 additional authors not shown)

    Abstract: We detail the sensitivity of the liquid xenon (LXe) DARWIN observatory to solar neutrinos via elastic electron scattering. We find that DARWIN will have the potential to measure the fluxes of five solar neutrino components: $pp$, $^7$Be, $^{13}$N, $^{15}$O and $pep$. The precision of the $^{13}$N, $^{15}$O and $pep$ components is hindered by the double-beta decay of $^{136}$Xe and, thus, would ben… ▽ More

    Submitted 20 December, 2020; v1 submitted 4 June, 2020; originally announced June 2020.

    Comments: 9 pages, 4 figures; for associated data files, see https://github.com/Physik-Institut-UZH/DARWIN-Sensitivity-Studies/tree/master/solar_neutrinos_electron_scattering

  16. Machine learning for causal inference: on the use of cross-fit estimators

    Authors: Paul N Zivich, Alexander Breskin

    Abstract: Modern causal inference methods allow machine learning to be used to weaken parametric modeling assumptions. However, the use of machine learning may result in complications for inference. Doubly-robust cross-fit estimators have been proposed to yield better statistical properties. We conducted a simulation study to assess the performance of several different estimators for the average causal ef… ▽ More

    Submitted 28 August, 2020; v1 submitted 21 April, 2020; originally announced April 2020.

    Comments: 19 pages, 3 figures

    Journal ref: Epidemiology 32:3 (2021) 393-401

  17. arXiv:2004.04251  [pdf

    stat.ME stat.AP

    DAG With Omitted Objects Displayed (DAGWOOD): A framework for revealing causal assumptions in DAGs

    Authors: Noah A Haber, Mollie E Wood, Sarah Wieten, Alexander Breskin

    Abstract: Directed acyclic graphs (DAGs) are frequently used in epidemiology as a method to encode causal inference assumptions. We propose the DAGWOOD framework to bring many of those encoded assumptions to the forefront. DAGWOOD combines a root DAG (the DAG in the proposed analysis) and a set of branch DAGs (alternative hidden assumptions to the root DAG). All branch DAGs share a common ruleset, and mus… ▽ More

    Submitted 23 November, 2021; v1 submitted 8 April, 2020; originally announced April 2020.

  18. Bubble-assisted Liquid Hole Multipliers in LXe and LAr: towards "local dual-phase TPCs"

    Authors: E. Erdal, L. Arazi, A. Breskin, S. Shchemelinin, A. Roy, A. Tesi, D. Vartsky, S. Bressler

    Abstract: The bubble-assisted Liquid Hole Multiplier (LHM) is a novel concept for the combined detection of ionization electrons and scintillation photons in noble-liquid time projection chambers. It consists of a perforated electrode immersed in the noble liquid, with heating wires generating a stable bubble underneath. Radiation-inducted ionization electrons in the liquid drift into the electrode's holes… ▽ More

    Submitted 23 December, 2019; originally announced December 2019.

    Comments: presented at LIDINE 2019; to be published in JINST

  19. First demonstration of a bubble-assisted Liquid Hole Multiplier operation in liquid argon

    Authors: Eran Erdal, Andrea Tesi, Amos Breskin, David Vartsky, Shikma Bressler

    Abstract: We demonstrate, for the time, the operation of a bubble-assisted Liquid Hole Multiplier (LHM) in liquid argon. The LHM, sensitive to both radiation-induced ionization electrons and primary scintillation photons, consists of a perforated electrode immersed in the noble liquid, with a stable gas-bubble trapped underneath. Electrons deposited in the liquid or scintillation-induced photoelectrons emit… ▽ More

    Submitted 26 September, 2019; v1 submitted 14 August, 2019; originally announced August 2019.

  20. First results of Resistive-Plate Well (RPWELL) detector operation at 163 K

    Authors: A. Roy, M. Morales, I. Israelashvili, A. Breskin, S. Bressler, D. Gonzalez-Diaz, C. Pecharromán, S. Shchemelinin, D. Vartsky, L. Arazi

    Abstract: We present for the first time, discharge-free operation at cryogenic conditions of a Resistive-Plate WELL (RPWELL) detector. It is a single-sided Thick Gaseous Electron Multiplier (THGEM) coupled to a readout anode via a plate of high bulk resistivity. The results of single- and double-stage RPWELL detectors operated in stable conditions in Ne/5$\%$CH$_{4}$ at 163 K are summarized. The RPWELL comp… ▽ More

    Submitted 11 July, 2019; originally announced July 2019.

    Comments: 14 pages, 8 figures, to be submitted to JINST

  21. arXiv:1904.05545  [pdf, other

    physics.ins-det hep-ex

    Novel Resistive-Plate WELL sampling element for (S)DHCAL

    Authors: S. Bressler, P. Bhattacharya, A. Breskin, A. E. C. Coimbra, D. Shaked-Renous, A. Tesi, L. Moler, M. Chefdeville, G. Vouters, J. Karyotakis, C. Drancourt, M. Titov, T. Geralis

    Abstract: Digital and Semi-Digital Hadronic Calorimeters (S)DHCAL were suggested for future Colliders as part of the particle-flow concept. Though studied mostly with RPC-based techniques, investigations have shown that MPGD-based sampling elements could outperform. An attractive, industry-produced, robust, particle-tracking detector for large-area coverage, e.g. in (S)DHCAL, could be the novel single-stage… ▽ More

    Submitted 26 September, 2019; v1 submitted 11 April, 2019; originally announced April 2019.

    Comments: 4 pages, 9 figures, Submitted to NIMA as VCI 2019 conference proceedings

  22. arXiv:1812.09536  [pdf, ps, other

    physics.ins-det nucl-ex

    Time Projection Chamber (TPC) Detectors for Nuclear Astrophysics Studies With Gamma Beams

    Authors: M. Gai, D. Schweitzer, S. R. Stern, A. H. Young, R. Smith, M. Cwiok, J. S. Bihalowicz, H. Czyrkowski, R. Dabrowski, W. Dominik, A. Fijalkowska, Z. Janas, L. Janiak, A. Korgul, T. Matulewicz, C. Mazzocchi, M. Pfuetzner, M. Zaremba, D. Balabanski, I. Gheorghe, C. Matei, O. Tesileanu, N. V. Zamfir, M. W. Ahmed, S. S. Henshaw , et al. (11 additional authors not shown)

    Abstract: Gamma-Beams at the HIgS facility in the USA and anticipated at the ELI-NP facility, now constructed in Romania, present unique new opportunities to advance research in nuclear astrophysics; not the least of which is resolving open questions in oxygen formation during stellar helium burning via a precise measurement of the 12C(a,g) reaction. Time projection chamber (TPC) detectors operating with lo… ▽ More

    Submitted 22 December, 2018; originally announced December 2018.

    Comments: Contribution Symposium on Radiation Measurements and Applications (SORMA XVII), June 11 - June 14 , 2018, University of Michigan, Ann Arbor

    Report number: UConn-40870-XXXX

  23. arXiv:1812.00780  [pdf

    physics.ins-det hep-ex

    First Imaging Results of a Bubble-assisted Liquid Hole Multiplier with SiPM readout in Liquid Xenon

    Authors: E. Erdal, A. Tesi, D. Vartsky, S. Bressler, L. Arazi, A. Breskin

    Abstract: First imaging results in liquid xenon of a Liquid Hole Multiplier (LHM) coupled to a Quad-Silicon Photomultiplier (SiPM) array are presented. Ionization electrons deposited in the noble liquid by 5.5 MeV alpha particles, are collected into the holes of a Thick Gas Electron Multiplier (THGEM) electrode having a xenon gas bubble trapped underneath. They drift through the liquid-gas interface, induci… ▽ More

    Submitted 14 January, 2019; v1 submitted 29 November, 2018; originally announced December 2018.

  24. arXiv:1801.00533  [pdf, other

    physics.ins-det hep-ex

    Measurements of charging-up processes in THGEM-based particle detectors

    Authors: M. Pitt, P. M. M. Correia, S. Bressler, A. E. C. Coimbra, D. Shaked Renous, C. D. R. Azevedo, J. F. C. A. Veloso, A. Breskin

    Abstract: The time-dependent gain variation of detectors incorporating Thick Gas Electron Multipliers (THGEM) electrodes was studied in the context of charging-up processes of the electrode's insulating surfaces. An experimental study was performed to examine model-simulation results of the aforementioned phenomena, under various experimental conditions. The results indicate that in a stable detector's envi… ▽ More

    Submitted 9 January, 2018; v1 submitted 1 January, 2018; originally announced January 2018.

  25. Simulation of gain stability of THGEM gas-avalanche particle detectors

    Authors: P. M. M. Correia, M. Pitt, C. D. R. Azevedo, A. Breskin, S. Bressler, C. A. B. Oliveira, A. L. M. Silva, R. Veenhof, J. F. C. A. Veloso

    Abstract: Charging-up processes affecting gain stability in Thick Gas Electron Multipliers (THGEM) were studied with a dedicated simulation toolkit. Integrated with Garfield++, it provides an effective platform for systematic phenomenological studies of charging-up processes in MPGD detectors. We describe the simulation tool and the fine-tuning of the step-size required for the algorithm convergence, in rel… ▽ More

    Submitted 6 November, 2017; originally announced November 2017.

  26. arXiv:1708.07051  [pdf, other

    astro-ph.IM astro-ph.CO hep-ex physics.ins-det

    The XENON1T Dark Matter Experiment

    Authors: XENON Collaboration, E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, F. D. Amaro, M. Anthony, B. Antunes, F. Arneodo, M. Balata, P. Barrow, L. Baudis, B. Bauermeister, M. L. Benabderrahmane, T. Berger, A. Breskin, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Bütikofer, J. Calvén, J. M. R. Cardoso , et al. (120 additional authors not shown)

    Abstract: The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is the first WIMP dark matter detector operating with a liquid xenon target mass above the ton-scale. Out of its 3.2t liquid xenon inventory, 2.0t constitute the active target of the dual-phase time projection chamber. The scintillation and ionization signals from particle interactions are detected with low-background photomu… ▽ More

    Submitted 23 August, 2017; originally announced August 2017.

    Comments: 22 pages, 25 figures

  27. Recent Advances in Bubble-Assisted Liquid Hole Multipliers in Liquid Xenon

    Authors: E. Erdal, L. Arazi, A. Tesi, A. Roy, S. Shchemelinin, D. Vartsky, A. Breskin

    Abstract: We report on recent advances in the operation of bubble-assisted Liquid Hole Multipliers (LHM). By confining a vapor bubble under or adjacent to a perforated electrode immersed in liquid xenon, we could record both radiation-induced ionization electrons and primary scintillation photons in the noble liquid. Four types of LHM electrodes were investigated: a THGEM, standard double-conical GEM, 50… ▽ More

    Submitted 3 November, 2018; v1 submitted 22 August, 2017; originally announced August 2017.

    Comments: 27 pages, 22 figures. Submitted to JINST

  28. arXiv:1708.00073  [pdf

    physics.ins-det

    Progress with Xenon Liquid Hole Multipliers

    Authors: Lior Arazi, Eran Erdal, Yevgeniya Korotinsky, Michael Rappaport, Arindam Roy, Sergei Shchemelinin, David Vartsky, Amos Breskin

    Abstract: The bubble-assisted Liquid Hole Multiplier (LHM) is a recently-proposed concept for the combined detection of ionization electrons and primary scintillation photons in noble-liquid time projection chambers. The LHM comprises a perforated micro-pattern electrode (e.g. Thick Gas Electron Multiplier - THGEM, or Gas Electron Multiplier - GEM) immersed in the liquid, with a bubble of the noble gas supp… ▽ More

    Submitted 31 July, 2017; originally announced August 2017.

    Comments: Presented at 2016 IEEE NSS/MIC, Strasbourg, France, 29 October - 5 November 2016

  29. Fast-neutron and gamma-ray imaging with a capillary liquid xenon converter coupled to a gaseous photomultiplier

    Authors: I. Israelashvili, A. E. C. Coimbra, D. Vartsky, L. Arazi, S. Shchemelinin, E. N. Caspi, A. Breskin

    Abstract: Gamma-ray and fast-neutron imaging was performed with a novel liquid xenon (LXe) scintillation detector read out by a Gaseous Photomultiplier (GPM). The 100 mm diameter detector prototype comprised a capillary-filled LXe converter/scintillator, coupled to a triple-THGEM imaging-GPM, with its first electrode coated by a CsI UV-photocathode, operated in Ne/5%CH4 cryogenic temperatures. Radiation loc… ▽ More

    Submitted 15 July, 2017; originally announced July 2017.

    Comments: 27 pages, 17 figures. Submitted to JINST

  30. Gain stabilization in Micro Pattern Gaseous Detectors: methodology and results

    Authors: Dan Shaked Renous, Arindam Roy, Amos Breskin, Shikma Bressler

    Abstract: The phenomenon of avalanche-gain variations over time, particularly in Micro Pattern Gaseous Detectors (MPGD) incorporating insulator materials, have been generally attributed to electric-field modifications resulting from "charging-up" effects of the insulator. A robust methodology for characterization of gain-transients in such detectors is presented. It comprises three guidelines: detector init… ▽ More

    Submitted 17 July, 2017; v1 submitted 13 July, 2017; originally announced July 2017.

  31. On the localization properties of an RPWELL gas-avalanche detector

    Authors: Luca Moleri, Purba Bhattacharya, Artur E. C. Coimbra, Amos Breskin, Shikma Bressler

    Abstract: A study of the localization properties of a single-element Resistive Plate WELL (RPWELL) detector is presented. The detector comprises of a single-sided THick Gaseous Electron Multiplier (THGEM) coupled to a segmented readout anode through a doped silicate-glass plate of 10$^{10}$ $Ω\cdot$cm bulk resistivity. Operated in ambient Ne/(5$\%$CH$_4$) gas, the detector has been investigated with 150 GeV… ▽ More

    Submitted 16 August, 2017; v1 submitted 1 July, 2017; originally announced July 2017.

  32. arXiv:1706.07689  [pdf

    physics.geo-ph physics.ins-det

    A method for rapid determination of oil and water content in geological formations

    Authors: D. Vartsky, M. B. Goldberg, V. Dangendorf, I. Israelashvili, I. Mor, D. Bar, K. Tittelmeier, M. Weierganz, B. Bromberger, A. Breskin

    Abstract: A novel method utilizing Fast Neutron Resonance Transmission Radiography is proposed for rapid, non-destructive and quantitative determination of the weight fractions of oil and water in cores taken from subterranean or underwater geological formations. Its ability to distinguish water from oil stems from the unambiguously-specific energy-dependence of the neutron cross-sections for the principal… ▽ More

    Submitted 22 June, 2017; originally announced June 2017.

    Comments: 11 pages, 7 figures. arXiv admin note: text overlap with arXiv:1602.06533

  33. arXiv:1607.02924  [pdf

    cond-mat.mtrl-sci physics.ins-det

    Observation of electron excitation into silicon conduction band by slow-ion surface neutralization

    Authors: S. Shchemelinin, A. Breskin

    Abstract: Bare reverse biased silicon photodiodes were exposed to 3eV He+, Ne+, Ar+, N2+, N+ and H2O+ ions. In all cases an increase of the reverse current through the diode was observed. This effect and its dependence on the ionization energy of the incident ions and on other factors are qualitatively explained in the framework of Auger-type surface neutralization theory. Amplification of the ion-induced c… ▽ More

    Submitted 18 October, 2016; v1 submitted 11 July, 2016; originally announced July 2016.

    Comments: 11 pages, 6 figures

  34. arXiv:1607.02587  [pdf, other

    physics.ins-det hep-ex

    In-beam evaluation of a medium-size Resistive-Plate WELL gaseous particle detector

    Authors: L. Moleri, F. D. Amaro, L. Arazi, C. D. R. Azevedo, A. Breskin, A. E. C. Coimbra, E. Oliveri, F. A. Pereira, D. Shaked Renous, J. Schaarschmidt, J. M. F. dos Santos, J. F. C. A. Veloso, S. Bressler

    Abstract: In-beam evaluation of a fully-equipped medium-size 30$\times$30 cm$^2$ Resistive Plate WELL (RPWELL) detector is presented. It consists here of a single element gas-avalanche multiplier with Semitron ESD225 resistive plate, 1 cm$^2$ readout pads and APV25/SRS electronics. Similarly to previous results with small detector prototypes, stable operation at high detection efficiency (>98%) and low aver… ▽ More

    Submitted 8 September, 2016; v1 submitted 9 July, 2016; originally announced July 2016.

    Comments: Prepared for submission to JINST

  35. arXiv:1606.07001  [pdf, other

    astro-ph.IM hep-ex physics.ins-det

    DARWIN: towards the ultimate dark matter detector

    Authors: J. Aalbers, F. Agostini, M. Alfonsi, F. D. Amaro, C. Amsler, E. Aprile, L. Arazi, F. Arneodo, P. Barrow, L. Baudis, M. L. Benabderrahmane, T. Berger, B. Beskers, A. Breskin, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Buetikofer, J. Calven, J. M. R. Cardoso, D. Cichon, D. Coderre , et al. (94 additional authors not shown)

    Abstract: DARk matter WImp search with liquid xenoN (DARWIN) will be an experiment for the direct detection of dark matter using a multi-ton liquid xenon time projection chamber at its core. Its primary goal will be to explore the experimentally accessible parameter space for Weakly Interacting Massive Particles (WIMPs) in a wide mass-range, until neutrino interactions with the target become an irreducible… ▽ More

    Submitted 22 June, 2016; originally announced June 2016.

    Comments: 36 pages, 11 figures

    Journal ref: JCAP 1611 (2016) no.11, 017

  36. arXiv:1603.07669  [pdf, other

    physics.ins-det astro-ph.IM

    First demonstration of VUV-photon detection in liquid xenon with THGEM and GEM-based Liquid Hole Multipliers

    Authors: E. Erdal, L. Arazi, M. Rappaport, S. Shchemelinin, D. Vartsky, A. Breskin

    Abstract: The bubble-assisted Liquid Hole-Multiplier (LHM) is a recently-introduced detection concept for noble-liquid time projection chambers. In this "local dual-phase" detection element, a gas bubble is supported underneath a perforated electrode (e.g., Thick Gas Electron Multiplier - THGEM, or Gas Electron Multiplier - GEM). Electrons drifting through the holes induce large electroluminescence signals… ▽ More

    Submitted 24 March, 2016; originally announced March 2016.

    Comments: Presented at the 2016 Vienna Conference on Instrumentation. Submitted to the conference proceedings in NIM A

  37. arXiv:1603.04820  [pdf, other

    physics.ins-det hep-ex

    The Resistive-Plate WELL with Argon mixtures - a robust gaseous radiation detector

    Authors: L. Moleri, F. D. Amaro, L. Arazi, C. D. R. Azevedo, E. Oliveri, M. Pitt, J. Schaarschmidt, D. Shaked-Renous, J. M. F. dos Santos, J. F. C. A. Veloso, A. Breskin, S. Bressler

    Abstract: A thin single-element THGEM-based, Resistive-Plate WELL (RPWELL) detector was operated with 150 GeV/c muon and pion beams in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$); signals were recorded with 1 cm$^2$ square pads and SRS/APV25 electronics. Detection efficiency values greater than 98% were reached in all the gas mixtures, at average pad multiplicity of 1.2. The use of the 10$^9$Ωcm resistiv… ▽ More

    Submitted 15 March, 2016; originally announced March 2016.

    Comments: presented at the 2016 VIenna Conf. On instrumentation. Submitted to the Conference proceedings

  38. arXiv:1602.06533  [pdf

    physics.geo-ph physics.ins-det

    Quantitative discrimination between oil and water in drilled bore cores via fast-neutron resonance transmission radiography

    Authors: D. Vartsky, M. B. Goldberg, V. Dangendorf, I. Israelashvili, I. Mor, D. Bar, K. Tittelmeier, M. Weierganz, A. Breskin

    Abstract: A novel method based on Fast Neutron Resonance Transmission Radiography is proposed for non-destructive, quantitative determination of the weight percentages of oil and water in cores taken from subterranean or underwater geological formations. The ability of the method to distinguish water from oil stems from the unambiguously-specific energy dependence of the neutron cross-sections for the princ… ▽ More

    Submitted 21 February, 2016; originally announced February 2016.

    Comments: 16 pages, 10 figures, patent pending

  39. arXiv:1512.07501  [pdf, other

    physics.ins-det astro-ph.CO

    Physics reach of the XENON1T dark matter experiment

    Authors: The XENON collaboration, E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, F. D. Amaro, M. Anthony, L. Arazi, F. Arneodo, C. Balan, P. Barrow, L. Baudis, B. Bauermeister, T. Berger, P. Breur, A. Breskin, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Bütikofer, J. M. R. Cardoso, M. Cervantes, D. Cichon , et al. (91 additional authors not shown)

    Abstract: The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds. The total electronic recoil background in $1$ tonne fiducial volume and (… ▽ More

    Submitted 15 April, 2016; v1 submitted 23 December, 2015; originally announced December 2015.

    Comments: 36 pages, 18 figures, published by JCAP

    Journal ref: JCAP04(2016)027

  40. First in-beam studies of a Resistive-Plate WELL gaseous multiplier

    Authors: S. Bressler, L. Moleri, M. Pitt, S. Kudella, D. C. R. Azevedo, F. D. Amaro, M. R. Jorge, J. M. F. dos Santos, J. F. C. A. Veloso, H. Natal da Luz, L. Arazi, E. Olivieri, A. Breskin

    Abstract: We present the results of the first in-beam studies of a medium size (10$\times$10 cm$^2$) Resistive-Plate WELL (RPWELL): a single-sided THGEM coupled to a pad anode through a resistive layer of high bulk resistivity ($\sim$10$^9 Ω$cm). The 6.2~mm thick (excluding readout electronics) single-stage detector was studied with 150~GeV muons and pions. Signals were recorded from 1$\times$1 cm$^2$ squar… ▽ More

    Submitted 20 January, 2016; v1 submitted 11 October, 2015; originally announced October 2015.

    Comments: Accepted by JINST

  41. arXiv:1509.02354  [pdf

    physics.ins-det

    Direct observation of bubble-assisted electroluminescence in liquid xenon

    Authors: E. Erdal, L. Arazi, V. Chepel, M. L. Rappaport, D. Vartsky, A. Breskin

    Abstract: Bubble formation in liquid xenon underneath a Thick Gaseous Electron Multiplier (THGEM) electrode immersed in liquid xenon was observed with a CCD camera. With voltage across the THGEM, the appearance of bubbles was correlated with that of electroluminescence signals induced by ionization electrons from alpha-particle tracks. This confirms recent indirect evidence that the observed photons are due… ▽ More

    Submitted 8 September, 2015; originally announced September 2015.

    Comments: Submitted to JINST

  42. First results of a large-area cryogenic gaseous photomultiplier coupled to a dual-phase liquid xenon TPC

    Authors: L. Arazi, A. E. C. Coimbra, E. Erdal, I. Israelashvili, M. L. Rappaport, S. Shchemelinin, D. Vartsky, J. M. F. dos Santos, A. Breskin

    Abstract: We discuss recent advances in the development of cryogenic gaseous photomultipliers (GPM), for possible use in dark matter and other rare-event searches using noble-liquid targets. We present results from a 10 cm diameter GPM coupled to a dual-phase liquid xenon (LXe) TPC, demonstrating - for the first time - the feasibility of recording both primary ("S1") and secondary ("S2") scintillation signa… ▽ More

    Submitted 3 August, 2015; originally announced August 2015.

    Comments: Submitted to JINST

  43. arXiv:1505.02316  [pdf

    physics.ins-det astro-ph.IM hep-ex

    Liquid Hole Multipliers: bubble-assisted electroluminescence in liquid xenon

    Authors: L. Arazi, E. Erdal, A. E. C. Coimbra, M. L. Rappaport, D. Vartsky, V. Chepel, A. Breskin

    Abstract: In this work we discuss the mechanism behind the large electroluminescence signals observed at relatively low electric fields in the holes of a Thick Gas Electron Multiplier (THGEM) electrode immersed in liquid xenon. We present strong evidence that the scintillation light is generated in xenon bubbles trapped below the THGEM holes. The process is shown to be remarkably stable over months of opera… ▽ More

    Submitted 13 May, 2015; v1 submitted 9 May, 2015; originally announced May 2015.

    Comments: Submitted to JINST

  44. A Comprehensive Simulation Study of a Liquid-Xe Detector for Contraband Detection

    Authors: I. Israelashvili, M. Cortesi, D. Vartsky, L. Arazi, D. Bar, E. N. Caspi, A. Breskin

    Abstract: Recently, a new detector concept, for combined imaging and spectroscopy of fast-neutrons and gamma was presented. It encompasses a liquid-xenon (LXe) converter-scintillator coupled to a UV-sensitive gaseous Thick Gas Electron Multiplier (THGEM)-based imaging photomultiplier (GPM). In this work we present and discuss the results of a systematic computer-simulation study aiming at optimizing the typ… ▽ More

    Submitted 31 December, 2014; originally announced January 2015.

    Comments: 29 pages, 17 figures

  45. Performance degradation of Geiger-mode APDs at cryogenic temperatures

    Authors: A. Bondar, A. Buzulutskov, A. Dolgov, L. Shekhtman, E. Shemyakina, A. Sokolov, A. Breskin, D. Thers

    Abstract: Two-phase Cryogenic Avalanche Detectors (CRADs) with THGEM multipliers, optically read out with Geiger-mode APDs (GAPDs), were proposed as potential technique for charge recording in rare-event experiments. In this work we report on the degradation of the GAPD performance at cryogenic temperatures revealed in the course of the study of two-phase CRAD in Ar, with combined THGEM/GAPD-matrix multipli… ▽ More

    Submitted 18 June, 2014; originally announced June 2014.

    Comments: 11 pages, 9 figures. Submitted to JINST

    Journal ref: JINST 9:P08006,2014

  46. arXiv:1406.2374  [pdf, other

    astro-ph.IM physics.ins-det

    Conceptual design and simulation of a water Cherenkov muon veto for the XENON1T experiment

    Authors: E. Aprile, F. Agostini, M. Alfonsi, K. Arisaka, F. Arneodo, M. Auger, C. Balan, P. Barrow, L. Baudis, B. Bauermeister, A. Behrens, P. Beltrame, K. Bokeloh, A. Breskin, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, J. M. R. Cardoso, A. P. Colijn, H. Contreras, J. P. Cussonneau, M. P. Decowski, E. Duchovni , et al. (66 additional authors not shown)

    Abstract: XENON is a dark matter direct detection project, consisting of a time projection chamber (TPC) filled with liquid xenon as detection medium. The construction of the next generation detector, XENON1T, is presently taking place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a sensitivity to spin-independent cross sections of $2 \cdot 10^{-47} ~ \mathrm{cm}^{\mathrm{2}}$ for W… ▽ More

    Submitted 25 February, 2015; v1 submitted 9 June, 2014; originally announced June 2014.

    Journal ref: JINST 9, P11006 (2014)

  47. A concept for laboratory studies of radiation detectors over a broad dynamic-range: instabilities evaluation in THGEM-structures

    Authors: S. Bressler, L. Moleri, L. Arazi, E. Erdal, A. Rubin, M. Pitt, A. Breskin

    Abstract: A simple methodology for evaluating the dynamic-range of gas avalanche detectors in the laboratory is presented and discussed. It comprises two tools: a charge injector of tunable gain which transfers radiation-induced amplified electron swarms to the investigated detector to mimic events with well defined primary-ionization spectra, and a systematic approach for measuring the detector's discharge… ▽ More

    Submitted 5 November, 2013; v1 submitted 2 November, 2013; originally announced November 2013.

  48. Laboratory studies of THGEM-based WELL structures with resistive anodes

    Authors: L. Arazi, M. Pitt, S. Bressler, L. Moleri, A. Rubin, A. Breskin

    Abstract: In this work we investigate three variants of single amplification-stage detector elements; they comprise THGEM electrodes closed at their bottom with metallic or resistive anodes to form WELL-type configurations. We present the results of a comparative study of the Thick-WELL (THWELL), Resistive-WELL (RWELL) and Segmented Resistive WELL (SRWELL), focusing on their performance in terms of spark-qu… ▽ More

    Submitted 23 October, 2013; originally announced October 2013.

    Comments: Submitted to JINST

  49. First observation of liquid-xenon proportional electroluminescence in THGEM holes

    Authors: L. Arazi, A. E. C. Coimbra, R. Itay, H. Landsman, L. Levinson, M. L. Rappaport, D. Vartsky, A. Breskin

    Abstract: Radiation-induced proportional-electroluminescence UV signals, emitted from the holes of a Thick Gas Electron Multiplier (THGEM) electrode immersed in liquid xenon, were recorded with a PMT for the first time. Significant photon yields were observed using a 0.4 mm thick electrode with 0.3 mm diameter holes; at 2 kV across the THGEM the photon yield was estimated to be ~600 UV photons/electron over… ▽ More

    Submitted 15 October, 2013; originally announced October 2013.

    Comments: To be published in the MPGD2013 JINST proceedings

  50. Recent advances with THGEM detectors

    Authors: S. Bressler, L. Arazi, L. Moleri, M. Pitt, A. Rubin, A. Breskin

    Abstract: The Thick Gaseous Electron Multiplier (THGEM) is a simple and robust electrode suitable for large area detectors. In this work the results of extensive comparative studies of the physical properties of different THGEM-based structures are reviewed. The focus is on newly suggested THGEM-like WELL configurations as well as on recently developed characterization methods. The WELL structures are singl… ▽ More

    Submitted 15 October, 2013; originally announced October 2013.

    Comments: presented at MPGD2013, Zaragoza, July 2013; submitted to JINST procedings