-
First observation of liquid xenon electroluminescence with a Microstrip Plate
Authors:
G. Martinez-Lema,
V. Chepel,
A. Roy,
A. Breskin
Abstract:
We report on the first observation of electroluminescence amplification with a Microstrip Plate immersed in liquid xenon. The electroluminescence of the liquid, induced by alpha-particles, was observed in an intense non-uniform electric field in the vicinity of 8-$μ$m narrow anode strips interlaced with wider cathode ones, deposited on the same side of a glass substrate. The electroluminescence yi…
▽ More
We report on the first observation of electroluminescence amplification with a Microstrip Plate immersed in liquid xenon. The electroluminescence of the liquid, induced by alpha-particles, was observed in an intense non-uniform electric field in the vicinity of 8-$μ$m narrow anode strips interlaced with wider cathode ones, deposited on the same side of a glass substrate. The electroluminescence yield in the liquid reached a value of $(35.5 \pm 2.6)$ VUV photons/electron. We propose ways of enhancing this response with more appropriate microstructures towards their potential incorporation as sensing elements in single-phase noble-liquid detectors.
△ Less
Submitted 23 January, 2024; v1 submitted 22 December, 2023;
originally announced December 2023.
-
Cryogenic RPWELL: a novel charge-readout element for dual-phase argon TPCs
Authors:
A. Tesi,
S. Leardini,
L. Moleri,
M. Morales,
D. Gonzalez-Diaz,
A. Jash,
A. Breskin,
S. Bressler
Abstract:
The first operation of a cryogenic Resistive Plate WELL (RPWELL) detector in the saturated vapor of liquid argon is reported. The RPWELL detector was composed of a Thick Gas Electron Multiplier (THGEM) electrode coupled to a metallic anode via Fe$_2$O$_3$/YSZ ceramics (Fe$_2$O$_3$ in weight equal to 75$\%$), with tunable bulk resistivity in the range 10$^{9}$ - 10$^{12}$ $Ω\cdot$cm. The detector w…
▽ More
The first operation of a cryogenic Resistive Plate WELL (RPWELL) detector in the saturated vapor of liquid argon is reported. The RPWELL detector was composed of a Thick Gas Electron Multiplier (THGEM) electrode coupled to a metallic anode via Fe$_2$O$_3$/YSZ ceramics (Fe$_2$O$_3$ in weight equal to 75$\%$), with tunable bulk resistivity in the range 10$^{9}$ - 10$^{12}$ $Ω\cdot$cm. The detector was operated at liquid argon temperature in saturated argon vapor (90~K, 1.2~bar) and characterized in terms of its effective charge gain and stability against discharges. Maximum stable gain of G$\approx$17 was obtained, without discharges. In addition, preliminary results from novel 3D-printed thermoplastic plates doped with carbon nanotubes are presented.
△ Less
Submitted 11 December, 2023;
originally announced December 2023.
-
Electron transfer efficiency in liquid xenon across THGEM holes
Authors:
G. Martínez-Lema,
A. Roy,
A. Breskin,
L. Arazi
Abstract:
Dual-phase liquid-xenon time projection chambers (LXe TPCs) deploying a few tonnes of liquid are presently leading the search for WIMP dark matter. Scaling these detectors to 10-fold larger fiducial masses, while improving their sensitivity to low-mass WIMPs presents difficult challenges in detector design. Several groups are considering a departure from current schemes, towards either single-phas…
▽ More
Dual-phase liquid-xenon time projection chambers (LXe TPCs) deploying a few tonnes of liquid are presently leading the search for WIMP dark matter. Scaling these detectors to 10-fold larger fiducial masses, while improving their sensitivity to low-mass WIMPs presents difficult challenges in detector design. Several groups are considering a departure from current schemes, towards either single-phase liquid-only TPCs, or dual-phase detectors where the electroluminescence region consists of patterned electrodes. Here, we discuss the possible use of Thick Gaseous Electron Multipliers (THGEMs) coated with a VUV photocathode and immersed in LXe as a building block in such designs. We focus on the transfer efficiencies of ionization electrons and photoelectrons emitted from the photocathode through the electrode holes, and show experimentally that efficiencies approaching 100 % can be achieved with realistic voltage settings. The observed voltage dependence of the transfer efficiencies is consistent with electron transport simulations once diffusion and charging-up effects are included.
△ Less
Submitted 9 November, 2023; v1 submitted 16 August, 2023;
originally announced August 2023.
-
The cryogenic RWELL: a stable charge multiplier for dual-phase liquid-argon detectors
Authors:
A. Tesi,
S. Leardini,
L. Moleri,
D. Gonzalez-Diaz,
A. Jash,
A. Breskin,
S. Bressler
Abstract:
The operation of a cryogenic Resistive WELL (RWELL) in liquid argon vapor is reported for the first time. It comprises a Thick Gas Electron Multiplier (THGEM) structure coupled to a resistive Diamond-Like Carbon (DLC) anode deposited on an insulating substrate. The multiplier was operated at cryogenic temperature (90~K, 1.2~bar) in saturated argon vapor and characterized in terms of charge gain an…
▽ More
The operation of a cryogenic Resistive WELL (RWELL) in liquid argon vapor is reported for the first time. It comprises a Thick Gas Electron Multiplier (THGEM) structure coupled to a resistive Diamond-Like Carbon (DLC) anode deposited on an insulating substrate. The multiplier was operated at cryogenic temperature (90~K, 1.2~bar) in saturated argon vapor and characterized in terms of charge gain and electrical stability. A comparative study with standard, non-resistive THGEM (a.k.a LEM) and WELL multipliers, confirmed the RWELL advantages in terms of discharge quenching - thus superior gain and stability.
△ Less
Submitted 26 September, 2023; v1 submitted 5 July, 2023;
originally announced July 2023.
-
Cosmogenic background simulations for the DARWIN observatory at different underground locations
Authors:
M. Adrover,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
B. Antunovic,
E. Aprile,
M. Babicz,
D. Bajpai,
E. Barberio,
L. Baudis,
M. Bazyk,
N. Bell,
L. Bellagamba,
R. Biondi,
Y. Biondi,
A. Bismark,
C. Boehm,
A. Breskin,
E. J. Brookes,
A. Brown,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso
, et al. (158 additional authors not shown)
Abstract:
Xenon dual-phase time projections chambers (TPCs) have proven to be a successful technology in studying physical phenomena that require low-background conditions. With 40t of liquid xenon (LXe) in the TPC baseline design, DARWIN will have a high sensitivity for the detection of particle dark matter, neutrinoless double beta decay ($0νββ$), and axion-like particles (ALPs). Although cosmic muons are…
▽ More
Xenon dual-phase time projections chambers (TPCs) have proven to be a successful technology in studying physical phenomena that require low-background conditions. With 40t of liquid xenon (LXe) in the TPC baseline design, DARWIN will have a high sensitivity for the detection of particle dark matter, neutrinoless double beta decay ($0νββ$), and axion-like particles (ALPs). Although cosmic muons are a source of background that cannot be entirely eliminated, they may be greatly diminished by placing the detector deep underground. In this study, we used Monte Carlo simulations to model the cosmogenic background expected for the DARWIN observatory at four underground laboratories: Laboratori Nazionali del Gran Sasso (LNGS), Sanford Underground Research Facility (SURF), Laboratoire Souterrain de Modane (LSM) and SNOLAB. We determine the production rates of unstable xenon isotopes and tritium due to muon-included neutron fluxes and muon-induced spallation. These are expected to represent the dominant contributions to cosmogenic backgrounds and thus the most relevant for site selection.
△ Less
Submitted 28 June, 2023;
originally announced June 2023.
-
Novel resistive charge-multipliers for dual-phase LAr-TPCs: towards stable operation at higher gains
Authors:
A. Tesi,
L. Moleri,
S. Leardini,
A. Breskin,
D. Gonzalez-Diaz,
L. Olano-Vegas,
A. Jash,
S. Bressler
Abstract:
Cryogenic versions of Resistive WELL (RWELL) and Resistive Plate WELL (RPWELL) detectors have been developed, aimed at stable avalanche multiplication of ionization electrons in dual-phase TPCs. In the RWELL, a thin resistive layer deposited on top of an insulator is inserted in between the electron multiplier (THGEM) and the readout anode; in the RPWELL, a resistive plate is directly coupled to t…
▽ More
Cryogenic versions of Resistive WELL (RWELL) and Resistive Plate WELL (RPWELL) detectors have been developed, aimed at stable avalanche multiplication of ionization electrons in dual-phase TPCs. In the RWELL, a thin resistive layer deposited on top of an insulator is inserted in between the electron multiplier (THGEM) and the readout anode; in the RPWELL, a resistive plate is directly coupled to the THGEM. Radiation-induced ionization electrons in the liquid are extracted into the gaseous phase. They drift into the THGEM's holes where they undergo charge multiplication. Embedding resistive materials into the multiplier proved to enhance operation stability due to the mitigation of electrical discharges - thus allowing operation at higher charge gain compared to standard THGEM (a.k.a. LEM) multipliers. We present the detector concepts and report on the main preliminary results.
△ Less
Submitted 21 May, 2023; v1 submitted 8 April, 2023;
originally announced April 2023.
-
First results on FHM -- a Floating Hole Multiplier
Authors:
V. Chepel,
G. Martinez-Lema,
A. Roy,
A. Breskin
Abstract:
A proof of principle of a novel concept for event recording in dual-phase liquid xenon detectors -- the Floating Hole Multiplier (FHM) -- is presented. It is shown that a standard Thick Gaseous Electron Multiplier (THGEM), freely floating on the liquid xenon surface permits extraction of electrons from the liquid to the gas. Secondary scintillation induced by the extracted electrons in the THGEM h…
▽ More
A proof of principle of a novel concept for event recording in dual-phase liquid xenon detectors -- the Floating Hole Multiplier (FHM) -- is presented. It is shown that a standard Thick Gaseous Electron Multiplier (THGEM), freely floating on the liquid xenon surface permits extraction of electrons from the liquid to the gas. Secondary scintillation induced by the extracted electrons in the THGEM holes as well as in the uniform field above it was observed. The first results with the FHM indicate that the concept of floating electrodes may offer new prospects for large-scale dual-phase detectors, for dark matter searches in particular.
△ Less
Submitted 30 January, 2023;
originally announced January 2023.
-
Diamond-like carbon coatings for cryogenic operation of particle detectors
Authors:
Sara Leardini,
Yi Zhou,
Andrea Tesi,
Miguel Morales,
Diego González-Díaz,
Amos Breskin,
Shikma Bressler,
Luca Moleri,
Vladimir Peskov
Abstract:
Characterization of diamond-like carbon (DLC) coatings at cryogenic temperatures (down to 77 K) is presented, covering the electrical resistivity range of practical interest to gaseous and liquid particle instrumentation: 10^-1-10^5 Mohm/sq. The good behaviour observed in terms of linearity, surface uniformity and stability with time and transported charge add to other well-known characteristics l…
▽ More
Characterization of diamond-like carbon (DLC) coatings at cryogenic temperatures (down to 77 K) is presented, covering the electrical resistivity range of practical interest to gaseous and liquid particle instrumentation: 10^-1-10^5 Mohm/sq. The good behaviour observed in terms of linearity, surface uniformity and stability with time and transported charge add to other well-known characteristics like low chemical reactivity and tolerance to radiation. The observed temperature dependence and stability of electrical properties with transported charge is consistent with a conductivity mechanism based on 2-dimensional variable-range electron hop**, as expected for the surface conductivity of thin films made from amorphous carbon. First results from a resistive-protected WELL detector ('RWELL') built with DLC and operated close to the liquid-vapor coexistence point of argon (87.5 K at 1 bar) are presented.
△ Less
Submitted 22 January, 2023; v1 submitted 30 September, 2022;
originally announced September 2022.
-
Test-Beam and Simulation Studies Towards RPWELL-based DHCAL
Authors:
Dan Shaked-Renous,
Fernando Domingues Amaro,
Purba Bhattacharya,
Amos Breskin,
Maximilien Chefdeville,
Cyril Drancourt,
Theo Geralis,
Yannis Karyotakis,
Luca Moleri,
Andrea Tesi,
Maxim Titov,
Joao Veloso,
Guillaum Vouters,
Shikma Bressler
Abstract:
Digital Hadronic Calorimeters (DHCAL) were suggested for future Colliders as part of the particle-flow concept. Though studied mainly with Resistive Plate Chambers (RPC), studies focusing on Micro-Pattern Gaseous Detector (MPGD)-based sampling elements have shown the potential advantages; they can be operated with environmental friendly gases and reach similar detection efficiency at lower average…
▽ More
Digital Hadronic Calorimeters (DHCAL) were suggested for future Colliders as part of the particle-flow concept. Though studied mainly with Resistive Plate Chambers (RPC), studies focusing on Micro-Pattern Gaseous Detector (MPGD)-based sampling elements have shown the potential advantages; they can be operated with environmental friendly gases and reach similar detection efficiency at lower average pad-multiplicity. We summarize here the experimental test-beam results of a small-size DHCAL prototype, incorporating six Micromegas (MM) and two Resistive-Plate WELL (RPWELL) sampling elements, interlaced with steel-absorber plates. It was investigated with 2-6 GeV pion beam at the CERN/PS beam facility. The data permitted validating a GEANT4 simulation framework of a DHCAL, and evaluating the expected pion energy resolution of a full-scale RPWELL-based calorimeter. The pion energy resolution of $\fracσ{E[GeV]}=\frac{50.8\%}{\sqrt{E[GeV]}} \oplus 10.3\%$ derived expected with the RPWELL concept is competitive to that of glass RPC and MM sampling techniques.
△ Less
Submitted 7 October, 2022; v1 submitted 26 August, 2022;
originally announced August 2022.
-
Bridged treatment comparisons: an illustrative application in HIV treatment
Authors:
Paul N Zivich,
Stephen R Cole,
Jessie K Edwards,
Bonnie E Shook-Sa,
Alexander Breskin,
Michael G Hudgens
Abstract:
Comparisons of treatments, interventions, or exposures are of central interest in epidemiology, but direct comparisons are not always possible due to practical or ethical reasons. Here, we detail a fusion approach to compare treatments across studies. The motivating example entails comparing the risk of the composite outcome of death, AIDS, or greater than a 50% CD4 cell count decline in people wi…
▽ More
Comparisons of treatments, interventions, or exposures are of central interest in epidemiology, but direct comparisons are not always possible due to practical or ethical reasons. Here, we detail a fusion approach to compare treatments across studies. The motivating example entails comparing the risk of the composite outcome of death, AIDS, or greater than a 50% CD4 cell count decline in people with HIV when assigned triple versus mono antiretroviral therapy, using data from the AIDS Clinical Trial Group (ACTG) 175 (mono versus dual therapy) and ACTG 320 (dual versus triple therapy). We review a set of identification assumptions and estimate the risk difference using an inverse probability weighting estimator that leverages the shared trial arms (dual therapy). A fusion diagnostic based on comparing the shared arms is proposed that may indicate violation of the identification assumptions. Application of the data fusion estimator and diagnostic to the ACTG trials indicates triple therapy results in a reduction in risk compared to monotherapy in individuals with baseline CD4 counts between 50 and 300 cells/mm$^3$. Bridged treatment comparisons address questions that none of the constituent data sources could address alone, but valid fusion-based inference requires careful consideration of the underlying assumptions.
△ Less
Submitted 22 August, 2023; v1 submitted 9 June, 2022;
originally announced June 2022.
-
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
Authors:
J. Aalbers,
K. Abe,
V. Aerne,
F. Agostini,
S. Ahmed Maouloud,
D. S. Akerib,
D. Yu. Akimov,
J. Akshat,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
L. Althueser,
C. S. Amarasinghe,
F. D. Amaro,
A. Ames,
T. J. Anderson,
B. Andrieu,
N. Angelides,
E. Angelino,
J. Angevaare,
V. C. Antochi,
D. Antón Martin,
B. Antunovic,
E. Aprile,
H. M. Araújo
, et al. (572 additional authors not shown)
Abstract:
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut…
▽ More
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.
△ Less
Submitted 4 March, 2022;
originally announced March 2022.
-
Novel electron and photon recording concepts in noble-liquid detectors
Authors:
Amos Breskin
Abstract:
We present several novel ionization-electron and scintillation-photon recording concepts in noble-liquid detectors, for future applications in particle and astroparticle physics and in other fields. These involve both single- and dual-phase detector configurations with combined electroluminescence and small charge multiplication in gas and liquid media.
We present several novel ionization-electron and scintillation-photon recording concepts in noble-liquid detectors, for future applications in particle and astroparticle physics and in other fields. These involve both single- and dual-phase detector configurations with combined electroluminescence and small charge multiplication in gas and liquid media.
△ Less
Submitted 9 May, 2022; v1 submitted 3 March, 2022;
originally announced March 2022.
-
Bubble dynamics in Liquid Hole Multipliers
Authors:
A. Tesi,
E. Segre,
S. Leardini,
A. Breskin,
S. Kapishnikov,
L. Moleri,
D. Vartsky,
S. Bressler
Abstract:
In bubble-assisted Liquid HoleMultipliers(LHM), developed for noble-liquid radiation detectors, the stability of the bubble and the electro-mechanical properties of the liquid-to-gas interface play a dominant role in the detector performance. A model is proposed to evaluate the static equilibrium configurations of a bubble sustained underneath a perforated electrode immersed in a liquid. For the f…
▽ More
In bubble-assisted Liquid HoleMultipliers(LHM), developed for noble-liquid radiation detectors, the stability of the bubble and the electro-mechanical properties of the liquid-to-gas interface play a dominant role in the detector performance. A model is proposed to evaluate the static equilibrium configurations of a bubble sustained underneath a perforated electrode immersed in a liquid. For the first time bubbles were optically observed in LAr; their properties were studied in contact with different material surfaces. This permitted investigating the bubble-electrodynamics via numerical simulations; it was shown that the electric field acts as an additional pressure term on the bubble meniscus. The predictions for the liquid-to-gas interface were successfully validated using X-ray micro-CT in water and in silicone oil at STP. The proposed model and the results of this study are an important milestone towards understanding and optimizing the parameters of LHM-based noble-liquid detectors.
△ Less
Submitted 26 July, 2021;
originally announced August 2021.
-
Single Electron Spectra in RPWELL-based detectors
Authors:
Purba Bhattacharya,
Andrea Tesi,
Dan Shaked-Renous,
Luca Moleri,
Amos Breskin,
Shikma Bressler
Abstract:
Single-electron avalanche distributions in gaseous multipliers affect their efficient detection and that of single UV-photons. In this work, we investigated the shape of single-photo-electron spectra in single- and double-stage Resistive Plate WELL (RPWELL) detector configurations, operated in $\mathrm{Ne/CH_{4}}$ and $\mathrm{Ar/CH_{4}}$. Discharge-free operation was reached over a broad dynamic…
▽ More
Single-electron avalanche distributions in gaseous multipliers affect their efficient detection and that of single UV-photons. In this work, we investigated the shape of single-photo-electron spectra in single- and double-stage Resistive Plate WELL (RPWELL) detector configurations, operated in $\mathrm{Ne/CH_{4}}$ and $\mathrm{Ar/CH_{4}}$. Discharge-free operation was reached over a broad dynamic range, with charge gains of \numrange[range-phrase = -]{e4}{e6}. Compared to the usual exponential ones, the observed Polya-like charge spectra pave the way towards higher single-electrons detection efficiencies. The latter were evaluated here, using experimental data combined with numerical simulations. The effects of the gas mixtures, electric field configuration and detector geometry on the Polya spectra and their related "$θ$" parameter are presented.
△ Less
Submitted 21 June, 2021; v1 submitted 5 January, 2021;
originally announced January 2021.
-
Solar Neutrino Detection Sensitivity in DARWIN via Electron Scattering
Authors:
J. Aalbers,
F. Agostini,
S. E. M. Ahmed Maouloud,
M. Alfonsi,
L. Althueser,
F. Amaro,
J. Angevaare,
V. C. Antochi,
B. Antunovic,
E. Aprile,
L. Arazi,
F. Arneodo,
M. Balzer,
L. Baudis,
D. Baur,
M. L. Benabderrahmane,
Y. Biondi,
A. Bismark,
C. Bourgeois,
A. Breskin,
P. A. Breur,
A. Brown,
E. Brown,
S. Brünner,
G. Bruno
, et al. (141 additional authors not shown)
Abstract:
We detail the sensitivity of the liquid xenon (LXe) DARWIN observatory to solar neutrinos via elastic electron scattering. We find that DARWIN will have the potential to measure the fluxes of five solar neutrino components: $pp$, $^7$Be, $^{13}$N, $^{15}$O and $pep$. The precision of the $^{13}$N, $^{15}$O and $pep$ components is hindered by the double-beta decay of $^{136}$Xe and, thus, would ben…
▽ More
We detail the sensitivity of the liquid xenon (LXe) DARWIN observatory to solar neutrinos via elastic electron scattering. We find that DARWIN will have the potential to measure the fluxes of five solar neutrino components: $pp$, $^7$Be, $^{13}$N, $^{15}$O and $pep$. The precision of the $^{13}$N, $^{15}$O and $pep$ components is hindered by the double-beta decay of $^{136}$Xe and, thus, would benefit from a depleted target. A high-statistics observation of $pp$ neutrinos would allow us to infer the values of the weak mixing angle, $\sin^2θ_w$, and the electron-type neutrino survival probability, $P_e$, in the electron recoil energy region from a few keV up to 200 keV for the first time, with relative precision of 5% and 4%, respectively, at an exposure of 300 ty. An observation of $pp$ and $^7$Be neutrinos would constrain the neutrino-inferred solar luminosity down to 0.2%. A combination of all flux measurements would distinguish between the high (GS98) and low metallicity (AGS09) solar models with 2.1-2.5$σ$ significance, independent of external measurements from other experiments or a measurement of $^8$B neutrinos through coherent elastic neutrino-nucleus scattering in DARWIN. Finally, we demonstrate that with a depleted target DARWIN may be sensitive to the neutrino capture process of $^{131}$Xe.
△ Less
Submitted 20 December, 2020; v1 submitted 4 June, 2020;
originally announced June 2020.
-
Machine learning for causal inference: on the use of cross-fit estimators
Authors:
Paul N Zivich,
Alexander Breskin
Abstract:
Modern causal inference methods allow machine learning to be used to weaken parametric modeling assumptions. However, the use of machine learning may result in complications for inference. Doubly-robust cross-fit estimators have been proposed to yield better statistical properties.
We conducted a simulation study to assess the performance of several different estimators for the average causal ef…
▽ More
Modern causal inference methods allow machine learning to be used to weaken parametric modeling assumptions. However, the use of machine learning may result in complications for inference. Doubly-robust cross-fit estimators have been proposed to yield better statistical properties.
We conducted a simulation study to assess the performance of several different estimators for the average causal effect (ACE). The data generating mechanisms for the simulated treatment and outcome included log-transforms, polynomial terms, and discontinuities. We compared singly-robust estimators (g-computation, inverse probability weighting) and doubly-robust estimators (augmented inverse probability weighting, targeted maximum likelihood estimation). Nuisance functions were estimated with parametric models and ensemble machine learning, separately. We further assessed doubly-robust cross-fit estimators.
With correctly specified parametric models, all of the estimators were unbiased and confidence intervals achieved nominal coverage. When used with machine learning, the doubly-robust cross-fit estimators substantially outperformed all of the other estimators in terms of bias, variance, and confidence interval coverage.
Due to the difficulty of properly specifying parametric models in high dimensional data, doubly-robust estimators with ensemble learning and cross-fitting may be the preferred approach for estimation of the ACE in most epidemiologic studies. However, these approaches may require larger sample sizes to avoid finite-sample issues.
△ Less
Submitted 28 August, 2020; v1 submitted 21 April, 2020;
originally announced April 2020.
-
DAG With Omitted Objects Displayed (DAGWOOD): A framework for revealing causal assumptions in DAGs
Authors:
Noah A Haber,
Mollie E Wood,
Sarah Wieten,
Alexander Breskin
Abstract:
Directed acyclic graphs (DAGs) are frequently used in epidemiology as a method to encode causal inference assumptions. We propose the DAGWOOD framework to bring many of those encoded assumptions to the forefront.
DAGWOOD combines a root DAG (the DAG in the proposed analysis) and a set of branch DAGs (alternative hidden assumptions to the root DAG). All branch DAGs share a common ruleset, and mus…
▽ More
Directed acyclic graphs (DAGs) are frequently used in epidemiology as a method to encode causal inference assumptions. We propose the DAGWOOD framework to bring many of those encoded assumptions to the forefront.
DAGWOOD combines a root DAG (the DAG in the proposed analysis) and a set of branch DAGs (alternative hidden assumptions to the root DAG). All branch DAGs share a common ruleset, and must 1) change the root DAG, 2) be a valid DAG, and either 3a) change the minimally sufficient adjustment set or 3b) change the number of frontdoor paths. Branch DAGs comprise a list of assumptions which must be justified as negligible. We define two types of branch DAGs: exclusion branch DAGs add a single- or bidirectional pathway between two nodes in the root DAG (e.g. direct pathways and colliders), while misdirection branch DAGs represent alternative pathways that could be drawn between objects (e.g., creating a collider by reversing the direction of causation for a controlled confounder).
The DAGWOOD framework 1) organizes causal model assumptions, 2) reinforces best DAG practices, 3) provides a framework for evaluation of causal models, and 4) can be used for generating causal models.
△ Less
Submitted 23 November, 2021; v1 submitted 8 April, 2020;
originally announced April 2020.
-
Bubble-assisted Liquid Hole Multipliers in LXe and LAr: towards "local dual-phase TPCs"
Authors:
E. Erdal,
L. Arazi,
A. Breskin,
S. Shchemelinin,
A. Roy,
A. Tesi,
D. Vartsky,
S. Bressler
Abstract:
The bubble-assisted Liquid Hole Multiplier (LHM) is a novel concept for the combined detection of ionization electrons and scintillation photons in noble-liquid time projection chambers. It consists of a perforated electrode immersed in the noble liquid, with heating wires generating a stable bubble underneath. Radiation-inducted ionization electrons in the liquid drift into the electrode's holes…
▽ More
The bubble-assisted Liquid Hole Multiplier (LHM) is a novel concept for the combined detection of ionization electrons and scintillation photons in noble-liquid time projection chambers. It consists of a perforated electrode immersed in the noble liquid, with heating wires generating a stable bubble underneath. Radiation-inducted ionization electrons in the liquid drift into the electrode's holes and cross the liquid-vapor interface into the bubble where they induce electroluminescence (EL). The top surface of the electrode is optionally coated with a CsI photocathode; radiation-induced UV-scintillation photons extract photoelectrons that induce EL in a similar way. EL-photons recorded with an array of photosensors, e.g. SiPMs, provide event localization. We present the basic principles of the LHM and summarize the results obtained in LXe and LAr.
△ Less
Submitted 23 December, 2019;
originally announced December 2019.
-
First demonstration of a bubble-assisted Liquid Hole Multiplier operation in liquid argon
Authors:
Eran Erdal,
Andrea Tesi,
Amos Breskin,
David Vartsky,
Shikma Bressler
Abstract:
We demonstrate, for the time, the operation of a bubble-assisted Liquid Hole Multiplier (LHM) in liquid argon. The LHM, sensitive to both radiation-induced ionization electrons and primary scintillation photons, consists of a perforated electrode immersed in the noble liquid, with a stable gas-bubble trapped underneath. Electrons deposited in the liquid or scintillation-induced photoelectrons emit…
▽ More
We demonstrate, for the time, the operation of a bubble-assisted Liquid Hole Multiplier (LHM) in liquid argon. The LHM, sensitive to both radiation-induced ionization electrons and primary scintillation photons, consists of a perforated electrode immersed in the noble liquid, with a stable gas-bubble trapped underneath. Electrons deposited in the liquid or scintillation-induced photoelectrons emitted from a photocathode on the electrode's surface, are collected into the holes; after crossing the liquid-gas interface, they induce electroluminescence within the bubble. After having validated in previous works the LHM concept in liquid xenon, we provide here first preliminary results on its operation in liquid argon. We demonstrate the bubble containment under a Thick Gas Electron Multiplier (THGEM) electrode and provide detector response to alpha particles, recorded with a SiPM - under electroluminescence and with modest gas multiplication; the imaging capability is also demonstrated.
△ Less
Submitted 26 September, 2019; v1 submitted 14 August, 2019;
originally announced August 2019.
-
First results of Resistive-Plate Well (RPWELL) detector operation at 163 K
Authors:
A. Roy,
M. Morales,
I. Israelashvili,
A. Breskin,
S. Bressler,
D. Gonzalez-Diaz,
C. Pecharromán,
S. Shchemelinin,
D. Vartsky,
L. Arazi
Abstract:
We present for the first time, discharge-free operation at cryogenic conditions of a Resistive-Plate WELL (RPWELL) detector. It is a single-sided Thick Gaseous Electron Multiplier (THGEM) coupled to a readout anode via a plate of high bulk resistivity. The results of single- and double-stage RPWELL detectors operated in stable conditions in Ne/5$\%$CH$_{4}$ at 163 K are summarized. The RPWELL comp…
▽ More
We present for the first time, discharge-free operation at cryogenic conditions of a Resistive-Plate WELL (RPWELL) detector. It is a single-sided Thick Gaseous Electron Multiplier (THGEM) coupled to a readout anode via a plate of high bulk resistivity. The results of single- and double-stage RPWELL detectors operated in stable conditions in Ne/5$\%$CH$_{4}$ at 163 K are summarized. The RPWELL comprised a ferric-based (Fe$^{3+}$) ceramic composite ("Fe-ceramic") as the resistive plate, of volume resistivity $\sim$$10^{11}$ $Ω$$\cdot$cm at this temperature. Gains of $\sim$$10^{4}$ and $\sim$$10^{5}$ were reached with the single-stage RPWELL, with 6 keV X-rays and single UV-photons, respectively. The double-stage detector, a THGEM followed by the RPWELL, reached gains $\sim$$10^{5}$ and $\sim$$10^{6}$ with X-rays and single UV-photons, respectively. The results were obtained with and without a CsI photocathode on the first multiplying element. Potential applications at these cryogenic conditions are discussed.
△ Less
Submitted 11 July, 2019;
originally announced July 2019.
-
Novel Resistive-Plate WELL sampling element for (S)DHCAL
Authors:
S. Bressler,
P. Bhattacharya,
A. Breskin,
A. E. C. Coimbra,
D. Shaked-Renous,
A. Tesi,
L. Moler,
M. Chefdeville,
G. Vouters,
J. Karyotakis,
C. Drancourt,
M. Titov,
T. Geralis
Abstract:
Digital and Semi-Digital Hadronic Calorimeters (S)DHCAL were suggested for future Colliders as part of the particle-flow concept. Though studied mostly with RPC-based techniques, investigations have shown that MPGD-based sampling elements could outperform. An attractive, industry-produced, robust, particle-tracking detector for large-area coverage, e.g. in (S)DHCAL, could be the novel single-stage…
▽ More
Digital and Semi-Digital Hadronic Calorimeters (S)DHCAL were suggested for future Colliders as part of the particle-flow concept. Though studied mostly with RPC-based techniques, investigations have shown that MPGD-based sampling elements could outperform. An attractive, industry-produced, robust, particle-tracking detector for large-area coverage, e.g. in (S)DHCAL, could be the novel single-stage Resistive Plate WELL (RPWELL). It is a single-sided THGEM coupled to the segmented readout electrode through a sheet of large bulk resistivity. We summarize here the preliminary test-beam results obtained with 6.5 mm thick (incl. electronics) {$48 \times 48\,\mathrm{cm^2}$}~RPWELL detectors. Two configurations are considered: a standalone RPWELL detector studied with 150 GeV muons and high-rate pions beams and RPWELL sampling element investigated within a small-(S)DHCAL prototype consisting of 7 resistive MICROMEGAS sampling elements followed by 5 RPWELL ones. The sampling elements were equipped with a Semi-Digital readout electronics based on the MICROROC chip.
△ Less
Submitted 26 September, 2019; v1 submitted 11 April, 2019;
originally announced April 2019.
-
Time Projection Chamber (TPC) Detectors for Nuclear Astrophysics Studies With Gamma Beams
Authors:
M. Gai,
D. Schweitzer,
S. R. Stern,
A. H. Young,
R. Smith,
M. Cwiok,
J. S. Bihalowicz,
H. Czyrkowski,
R. Dabrowski,
W. Dominik,
A. Fijalkowska,
Z. Janas,
L. Janiak,
A. Korgul,
T. Matulewicz,
C. Mazzocchi,
M. Pfuetzner,
M. Zaremba,
D. Balabanski,
I. Gheorghe,
C. Matei,
O. Tesileanu,
N. V. Zamfir,
M. W. Ahmed,
S. S. Henshaw
, et al. (11 additional authors not shown)
Abstract:
Gamma-Beams at the HIgS facility in the USA and anticipated at the ELI-NP facility, now constructed in Romania, present unique new opportunities to advance research in nuclear astrophysics; not the least of which is resolving open questions in oxygen formation during stellar helium burning via a precise measurement of the 12C(a,g) reaction. Time projection chamber (TPC) detectors operating with lo…
▽ More
Gamma-Beams at the HIgS facility in the USA and anticipated at the ELI-NP facility, now constructed in Romania, present unique new opportunities to advance research in nuclear astrophysics; not the least of which is resolving open questions in oxygen formation during stellar helium burning via a precise measurement of the 12C(a,g) reaction. Time projection chamber (TPC) detectors operating with low pressure gas (as an active target) are ideally suited for such studies. We review the progress of the current research program and plans for the future at the HIγS facility with the optical readout TPC (O-TPC) and the development of an electronic readout TPC for the ELI-NP facility (ELITPC).
△ Less
Submitted 22 December, 2018;
originally announced December 2018.
-
First Imaging Results of a Bubble-assisted Liquid Hole Multiplier with SiPM readout in Liquid Xenon
Authors:
E. Erdal,
A. Tesi,
D. Vartsky,
S. Bressler,
L. Arazi,
A. Breskin
Abstract:
First imaging results in liquid xenon of a Liquid Hole Multiplier (LHM) coupled to a Quad-Silicon Photomultiplier (SiPM) array are presented. Ionization electrons deposited in the noble liquid by 5.5 MeV alpha particles, are collected into the holes of a Thick Gas Electron Multiplier (THGEM) electrode having a xenon gas bubble trapped underneath. They drift through the liquid-gas interface, induci…
▽ More
First imaging results in liquid xenon of a Liquid Hole Multiplier (LHM) coupled to a Quad-Silicon Photomultiplier (SiPM) array are presented. Ionization electrons deposited in the noble liquid by 5.5 MeV alpha particles, are collected into the holes of a Thick Gas Electron Multiplier (THGEM) electrode having a xenon gas bubble trapped underneath. They drift through the liquid-gas interface, inducing electroluminescence within the bubble. The resulting photons are detected with a Hamamatsu VUV4 quad-SiPM array - providing the deposited energy with a charge-only RMS resolution of 6.6%. The image reconstruction resolution was estimated to be ~200 um (RMS).
△ Less
Submitted 14 January, 2019; v1 submitted 29 November, 2018;
originally announced December 2018.
-
Measurements of charging-up processes in THGEM-based particle detectors
Authors:
M. Pitt,
P. M. M. Correia,
S. Bressler,
A. E. C. Coimbra,
D. Shaked Renous,
C. D. R. Azevedo,
J. F. C. A. Veloso,
A. Breskin
Abstract:
The time-dependent gain variation of detectors incorporating Thick Gas Electron Multipliers (THGEM) electrodes was studied in the context of charging-up processes of the electrode's insulating surfaces. An experimental study was performed to examine model-simulation results of the aforementioned phenomena, under various experimental conditions. The results indicate that in a stable detector's envi…
▽ More
The time-dependent gain variation of detectors incorporating Thick Gas Electron Multipliers (THGEM) electrodes was studied in the context of charging-up processes of the electrode's insulating surfaces. An experimental study was performed to examine model-simulation results of the aforementioned phenomena, under various experimental conditions. The results indicate that in a stable detector's environment, the gain stabilization process is mainly affected by the charging-up of the detector's insulating surfaces caused by the avalanche charges. The charging-up is a transient effect, occurring during the detector's initial operation period; it does not affect its long-term operation. The experimental results are consistent with the outcome of model-simulations.
△ Less
Submitted 9 January, 2018; v1 submitted 1 January, 2018;
originally announced January 2018.
-
Simulation of gain stability of THGEM gas-avalanche particle detectors
Authors:
P. M. M. Correia,
M. Pitt,
C. D. R. Azevedo,
A. Breskin,
S. Bressler,
C. A. B. Oliveira,
A. L. M. Silva,
R. Veenhof,
J. F. C. A. Veloso
Abstract:
Charging-up processes affecting gain stability in Thick Gas Electron Multipliers (THGEM) were studied with a dedicated simulation toolkit. Integrated with Garfield++, it provides an effective platform for systematic phenomenological studies of charging-up processes in MPGD detectors. We describe the simulation tool and the fine-tuning of the step-size required for the algorithm convergence, in rel…
▽ More
Charging-up processes affecting gain stability in Thick Gas Electron Multipliers (THGEM) were studied with a dedicated simulation toolkit. Integrated with Garfield++, it provides an effective platform for systematic phenomenological studies of charging-up processes in MPGD detectors. We describe the simulation tool and the fine-tuning of the step-size required for the algorithm convergence, in relation to physical parameters. Simulation results of gain stability over time in THGEM detectors are presented, exploring the role of electrode-thickness and applied voltage on its evolution. The results show that the total amount of irradiated charge through electrode's hole needed for reaching gain stabilization is in the range of tens to hundreds of pC, depending on the detector geometry and operational voltage. These results are in agreement with experimental observations presented previously.
△ Less
Submitted 6 November, 2017;
originally announced November 2017.
-
The XENON1T Dark Matter Experiment
Authors:
XENON Collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
M. Anthony,
B. Antunes,
F. Arneodo,
M. Balata,
P. Barrow,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
A. Breskin,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Bütikofer,
J. Calvén,
J. M. R. Cardoso
, et al. (120 additional authors not shown)
Abstract:
The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is the first WIMP dark matter detector operating with a liquid xenon target mass above the ton-scale. Out of its 3.2t liquid xenon inventory, 2.0t constitute the active target of the dual-phase time projection chamber. The scintillation and ionization signals from particle interactions are detected with low-background photomu…
▽ More
The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is the first WIMP dark matter detector operating with a liquid xenon target mass above the ton-scale. Out of its 3.2t liquid xenon inventory, 2.0t constitute the active target of the dual-phase time projection chamber. The scintillation and ionization signals from particle interactions are detected with low-background photomultipliers. This article describes the XENON1T instrument and its subsystems as well as strategies to achieve an unprecedented low background level. First results on the detector response and the performance of the subsystems are also presented.
△ Less
Submitted 23 August, 2017;
originally announced August 2017.
-
Recent Advances in Bubble-Assisted Liquid Hole Multipliers in Liquid Xenon
Authors:
E. Erdal,
L. Arazi,
A. Tesi,
A. Roy,
S. Shchemelinin,
D. Vartsky,
A. Breskin
Abstract:
We report on recent advances in the operation of bubble-assisted Liquid Hole Multipliers (LHM). By confining a vapor bubble under or adjacent to a perforated electrode immersed in liquid xenon, we could record both radiation-induced ionization electrons and primary scintillation photons in the noble liquid. Four types of LHM electrodes were investigated: a THGEM, standard double-conical GEM, 50…
▽ More
We report on recent advances in the operation of bubble-assisted Liquid Hole Multipliers (LHM). By confining a vapor bubble under or adjacent to a perforated electrode immersed in liquid xenon, we could record both radiation-induced ionization electrons and primary scintillation photons in the noble liquid. Four types of LHM electrodes were investigated: a THGEM, standard double-conical GEM, 50 $μ$m-thick single-conical GEM (SC-GEM) and 125 $μ$m-thick SC-GEM - all coated with CsI photocathodes. The 125 $μ$m-thick SC-GEM provided the highest electroluminescence (EL) yields, up to ~400 photons per electron over 4$π$ with an RMS pulse-height resolution reaching 5.5% for events comprising ~7000 primary electrons. Applying a high transfer field across the bubble, the EL yield was further increased by a factor of ~5. The feasibility of a vertical-mode LHM, with the bubble confined between two vertical electrodes, and the operation of a two-stage LHM configuration were demonstrated for the first time. We combine electrostatic simulations with observed signals to draw conclusions regarding the location of the liquid-gas interface and suggest an explanation for the observed differences in EL yield between the investigated electrodes.
△ Less
Submitted 3 November, 2018; v1 submitted 22 August, 2017;
originally announced August 2017.
-
Progress with Xenon Liquid Hole Multipliers
Authors:
Lior Arazi,
Eran Erdal,
Yevgeniya Korotinsky,
Michael Rappaport,
Arindam Roy,
Sergei Shchemelinin,
David Vartsky,
Amos Breskin
Abstract:
The bubble-assisted Liquid Hole Multiplier (LHM) is a recently-proposed concept for the combined detection of ionization electrons and primary scintillation photons in noble-liquid time projection chambers. The LHM comprises a perforated micro-pattern electrode (e.g. Thick Gas Electron Multiplier - THGEM, or Gas Electron Multiplier - GEM) immersed in the liquid, with a bubble of the noble gas supp…
▽ More
The bubble-assisted Liquid Hole Multiplier (LHM) is a recently-proposed concept for the combined detection of ionization electrons and primary scintillation photons in noble-liquid time projection chambers. The LHM comprises a perforated micro-pattern electrode (e.g. Thick Gas Electron Multiplier - THGEM, or Gas Electron Multiplier - GEM) immersed in the liquid, with a bubble of the noble gas supported underneath. Ionization electrons and scintillation-induced photoelectrons extracted from a cesium iodide photocathode drift through the electrode's holes and induce electroluminescence (EL) signals in the bubble; these are recorded by photon detectors located closely below the electrode. We present recent results in the development of LHMs, comparing the response of different electrodes to ionization and photon-induced electrons.
△ Less
Submitted 31 July, 2017;
originally announced August 2017.
-
Fast-neutron and gamma-ray imaging with a capillary liquid xenon converter coupled to a gaseous photomultiplier
Authors:
I. Israelashvili,
A. E. C. Coimbra,
D. Vartsky,
L. Arazi,
S. Shchemelinin,
E. N. Caspi,
A. Breskin
Abstract:
Gamma-ray and fast-neutron imaging was performed with a novel liquid xenon (LXe) scintillation detector read out by a Gaseous Photomultiplier (GPM). The 100 mm diameter detector prototype comprised a capillary-filled LXe converter/scintillator, coupled to a triple-THGEM imaging-GPM, with its first electrode coated by a CsI UV-photocathode, operated in Ne/5%CH4 cryogenic temperatures. Radiation loc…
▽ More
Gamma-ray and fast-neutron imaging was performed with a novel liquid xenon (LXe) scintillation detector read out by a Gaseous Photomultiplier (GPM). The 100 mm diameter detector prototype comprised a capillary-filled LXe converter/scintillator, coupled to a triple-THGEM imaging-GPM, with its first electrode coated by a CsI UV-photocathode, operated in Ne/5%CH4 cryogenic temperatures. Radiation localization in 2D was derived from scintillation-induced photoelectron avalanches, measured on the GPM's segmented anode. The localization properties of Co-60 gamma-rays and a mixed fast-neutron/gamma-ray field from an AmBe neutron source were derived from irradiation of a Pb edge absorber. Spatial resolutions of 12+/-2 mm and 10+/-2 mm (FWHM) were reached with Co-60 and AmBe sources, respectively. The experimental results are in good agreement with GEANT4 simulations. The calculated ultimate expected resolutions for our application-relevant 4.4 and 15.1 MeV gamma-rays and 1-15 MeV neutrons are 2-4 mm and ~2 mm (FWHM), respectively. These results indicate the potential applicability of the new detector concept to Fast-Neutron Resonance Radiography (FNRR) and Dual-Discrete-Energy Gamma Radiography (DDEGR) of large objects.
△ Less
Submitted 15 July, 2017;
originally announced July 2017.
-
Gain stabilization in Micro Pattern Gaseous Detectors: methodology and results
Authors:
Dan Shaked Renous,
Arindam Roy,
Amos Breskin,
Shikma Bressler
Abstract:
The phenomenon of avalanche-gain variations over time, particularly in Micro Pattern Gaseous Detectors (MPGD) incorporating insulator materials, have been generally attributed to electric-field modifications resulting from "charging-up" effects of the insulator. A robust methodology for characterization of gain-transients in such detectors is presented. It comprises three guidelines: detector init…
▽ More
The phenomenon of avalanche-gain variations over time, particularly in Micro Pattern Gaseous Detectors (MPGD) incorporating insulator materials, have been generally attributed to electric-field modifications resulting from "charging-up" effects of the insulator. A robust methodology for characterization of gain-transients in such detectors is presented. It comprises three guidelines: detector initialization, long-gain stabilization monitoring and imposing transients by applying abrupt changes in operation conditions. Using THWELL and RPWELL detectors, we validated the proposed methodology by assessing a charging-up/charging-down model describing the governing processes of gain stabilization. The results provide a deeper insight into these processes, reflected by different transients upon abrupt variations of detector gain or the irradiation rate. This methodology provides a handle for future investigations of the involved physics phenomena in MPGD detectors comprising insulating components.
△ Less
Submitted 17 July, 2017; v1 submitted 13 July, 2017;
originally announced July 2017.
-
On the localization properties of an RPWELL gas-avalanche detector
Authors:
Luca Moleri,
Purba Bhattacharya,
Artur E. C. Coimbra,
Amos Breskin,
Shikma Bressler
Abstract:
A study of the localization properties of a single-element Resistive Plate WELL (RPWELL) detector is presented. The detector comprises of a single-sided THick Gaseous Electron Multiplier (THGEM) coupled to a segmented readout anode through a doped silicate-glass plate of 10$^{10}$ $Ω\cdot$cm bulk resistivity. Operated in ambient Ne/(5$\%$CH$_4$) gas, the detector has been investigated with 150 GeV…
▽ More
A study of the localization properties of a single-element Resistive Plate WELL (RPWELL) detector is presented. The detector comprises of a single-sided THick Gaseous Electron Multiplier (THGEM) coupled to a segmented readout anode through a doped silicate-glass plate of 10$^{10}$ $Ω\cdot$cm bulk resistivity. Operated in ambient Ne/(5$\%$CH$_4$) gas, the detector has been investigated with 150 GeV muons at CERN-SPS. Signals induced through the resistive plate on anode readout strips were recorded with APV25/SRS electronics. The experimental results are compared with that of Monte Carlo simulations. The effects of various physics phenomena on the position resolution are discussed. The measured position resolution in the present configuration is 0.28 mm RMS - compatible with the holes-pattern of the multiplier. Possible ways for improving the detector position resolution are suggested.
△ Less
Submitted 16 August, 2017; v1 submitted 1 July, 2017;
originally announced July 2017.
-
A method for rapid determination of oil and water content in geological formations
Authors:
D. Vartsky,
M. B. Goldberg,
V. Dangendorf,
I. Israelashvili,
I. Mor,
D. Bar,
K. Tittelmeier,
M. Weierganz,
B. Bromberger,
A. Breskin
Abstract:
A novel method utilizing Fast Neutron Resonance Transmission Radiography is proposed for rapid, non-destructive and quantitative determination of the weight fractions of oil and water in cores taken from subterranean or underwater geological formations. Its ability to distinguish water from oil stems from the unambiguously-specific energy-dependence of the neutron cross-sections for the principal…
▽ More
A novel method utilizing Fast Neutron Resonance Transmission Radiography is proposed for rapid, non-destructive and quantitative determination of the weight fractions of oil and water in cores taken from subterranean or underwater geological formations. Its ability to distinguish water from oil stems from the unambiguously-specific energy-dependence of the neutron cross-sections for the principal elemental constituents. Furthermore, the fluid weight fractions permit determining core porosity and oil and water saturations. In this article we show results of experimental determination of oil and water weight fractions in 10 cm thick samples of Berea Sandstone and Indiana Limestone formations, followed by calculation of their porosity and fluid saturations. The technique may ultimately permit rapid, accurate and non-destructive evaluation of relevant petro-physical properties in thick intact cores. It is suitable for all types of formations including tight shales, clays and oil sands.
△ Less
Submitted 22 June, 2017;
originally announced June 2017.
-
Observation of electron excitation into silicon conduction band by slow-ion surface neutralization
Authors:
S. Shchemelinin,
A. Breskin
Abstract:
Bare reverse biased silicon photodiodes were exposed to 3eV He+, Ne+, Ar+, N2+, N+ and H2O+ ions. In all cases an increase of the reverse current through the diode was observed. This effect and its dependence on the ionization energy of the incident ions and on other factors are qualitatively explained in the framework of Auger-type surface neutralization theory. Amplification of the ion-induced c…
▽ More
Bare reverse biased silicon photodiodes were exposed to 3eV He+, Ne+, Ar+, N2+, N+ and H2O+ ions. In all cases an increase of the reverse current through the diode was observed. This effect and its dependence on the ionization energy of the incident ions and on other factors are qualitatively explained in the framework of Auger-type surface neutralization theory. Amplification of the ion-induced charge was observed with an avalanche photodiode under high applied bias. The observed effect can be considered as ion-induced internal potential electron emission into the conduction band of silicon. To the best of our knowledge, no experimental evidence of such effect was previously reported. Possible applications are discussed.
△ Less
Submitted 18 October, 2016; v1 submitted 11 July, 2016;
originally announced July 2016.
-
In-beam evaluation of a medium-size Resistive-Plate WELL gaseous particle detector
Authors:
L. Moleri,
F. D. Amaro,
L. Arazi,
C. D. R. Azevedo,
A. Breskin,
A. E. C. Coimbra,
E. Oliveri,
F. A. Pereira,
D. Shaked Renous,
J. Schaarschmidt,
J. M. F. dos Santos,
J. F. C. A. Veloso,
S. Bressler
Abstract:
In-beam evaluation of a fully-equipped medium-size 30$\times$30 cm$^2$ Resistive Plate WELL (RPWELL) detector is presented. It consists here of a single element gas-avalanche multiplier with Semitron ESD225 resistive plate, 1 cm$^2$ readout pads and APV25/SRS electronics. Similarly to previous results with small detector prototypes, stable operation at high detection efficiency (>98%) and low aver…
▽ More
In-beam evaluation of a fully-equipped medium-size 30$\times$30 cm$^2$ Resistive Plate WELL (RPWELL) detector is presented. It consists here of a single element gas-avalanche multiplier with Semitron ESD225 resistive plate, 1 cm$^2$ readout pads and APV25/SRS electronics. Similarly to previous results with small detector prototypes, stable operation at high detection efficiency (>98%) and low average pad multiplicity (~1.2) were recorded with 150 GeV muon and high-rate pion beams, in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$). This is an important step towards the realization of robust detectors suitable for applications requiring large-area coverage; among them Digital Hadron Calorimetry.
△ Less
Submitted 8 September, 2016; v1 submitted 9 July, 2016;
originally announced July 2016.
-
DARWIN: towards the ultimate dark matter detector
Authors:
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
C. Amsler,
E. Aprile,
L. Arazi,
F. Arneodo,
P. Barrow,
L. Baudis,
M. L. Benabderrahmane,
T. Berger,
B. Beskers,
A. Breskin,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Buetikofer,
J. Calven,
J. M. R. Cardoso,
D. Cichon,
D. Coderre
, et al. (94 additional authors not shown)
Abstract:
DARk matter WImp search with liquid xenoN (DARWIN) will be an experiment for the direct detection of dark matter using a multi-ton liquid xenon time projection chamber at its core. Its primary goal will be to explore the experimentally accessible parameter space for Weakly Interacting Massive Particles (WIMPs) in a wide mass-range, until neutrino interactions with the target become an irreducible…
▽ More
DARk matter WImp search with liquid xenoN (DARWIN) will be an experiment for the direct detection of dark matter using a multi-ton liquid xenon time projection chamber at its core. Its primary goal will be to explore the experimentally accessible parameter space for Weakly Interacting Massive Particles (WIMPs) in a wide mass-range, until neutrino interactions with the target become an irreducible background. The prompt scintillation light and the charge signals induced by particle interactions in the xenon will be observed by VUV sensitive, ultra-low background photosensors. Besides its excellent sensitivity to WIMPs above a mass of 5 GeV/c2, such a detector with its large mass, low-energy threshold and ultra-low background level will also be sensitive to other rare interactions. It will search for solar axions, galactic axion-like particles and the neutrinoless double-beta decay of 136-Xe, as well as measure the low-energy solar neutrino flux with <1% precision, observe coherent neutrino-nucleus interactions, and detect galactic supernovae. We present the concept of the DARWIN detector and discuss its physics reach, the main sources of backgrounds and the ongoing detector design and R&D efforts.
△ Less
Submitted 22 June, 2016;
originally announced June 2016.
-
First demonstration of VUV-photon detection in liquid xenon with THGEM and GEM-based Liquid Hole Multipliers
Authors:
E. Erdal,
L. Arazi,
M. Rappaport,
S. Shchemelinin,
D. Vartsky,
A. Breskin
Abstract:
The bubble-assisted Liquid Hole-Multiplier (LHM) is a recently-introduced detection concept for noble-liquid time projection chambers. In this "local dual-phase" detection element, a gas bubble is supported underneath a perforated electrode (e.g., Thick Gas Electron Multiplier - THGEM, or Gas Electron Multiplier - GEM). Electrons drifting through the holes induce large electroluminescence signals…
▽ More
The bubble-assisted Liquid Hole-Multiplier (LHM) is a recently-introduced detection concept for noble-liquid time projection chambers. In this "local dual-phase" detection element, a gas bubble is supported underneath a perforated electrode (e.g., Thick Gas Electron Multiplier - THGEM, or Gas Electron Multiplier - GEM). Electrons drifting through the holes induce large electroluminescence signals as they pass into the bubble. In this work we report on recent results of THGEM and GEM electrodes coated with cesium iodide and immersed in liquid xenon, allowing - for the first time - the detection of primary VUV scintillation photons in addition to ionization electrons using LHMs.
△ Less
Submitted 24 March, 2016;
originally announced March 2016.
-
The Resistive-Plate WELL with Argon mixtures - a robust gaseous radiation detector
Authors:
L. Moleri,
F. D. Amaro,
L. Arazi,
C. D. R. Azevedo,
E. Oliveri,
M. Pitt,
J. Schaarschmidt,
D. Shaked-Renous,
J. M. F. dos Santos,
J. F. C. A. Veloso,
A. Breskin,
S. Bressler
Abstract:
A thin single-element THGEM-based, Resistive-Plate WELL (RPWELL) detector was operated with 150 GeV/c muon and pion beams in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$); signals were recorded with 1 cm$^2$ square pads and SRS/APV25 electronics. Detection efficiency values greater than 98% were reached in all the gas mixtures, at average pad multiplicity of 1.2. The use of the 10$^9$Ωcm resistiv…
▽ More
A thin single-element THGEM-based, Resistive-Plate WELL (RPWELL) detector was operated with 150 GeV/c muon and pion beams in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$); signals were recorded with 1 cm$^2$ square pads and SRS/APV25 electronics. Detection efficiency values greater than 98% were reached in all the gas mixtures, at average pad multiplicity of 1.2. The use of the 10$^9$Ωcm resistive plate resulted in a completely discharge-free operation also in intense pion beams. The efficiency remained essentially constant at 98-99% up to fluxes of $\sim$10$^4$Hz/cm$^2$, drop** by a few % when approaching 10$^5$ Hz/cm$^2$. These results pave the way towards cost-effective, robust, efficient, large-scale detectors for a variety of applications in future particle, astro-particle and applied fields. A potential target application is digital hadron calorimetry.
△ Less
Submitted 15 March, 2016;
originally announced March 2016.
-
Quantitative discrimination between oil and water in drilled bore cores via fast-neutron resonance transmission radiography
Authors:
D. Vartsky,
M. B. Goldberg,
V. Dangendorf,
I. Israelashvili,
I. Mor,
D. Bar,
K. Tittelmeier,
M. Weierganz,
A. Breskin
Abstract:
A novel method based on Fast Neutron Resonance Transmission Radiography is proposed for non-destructive, quantitative determination of the weight percentages of oil and water in cores taken from subterranean or underwater geological formations. The ability of the method to distinguish water from oil stems from the unambiguously-specific energy dependence of the neutron cross-sections for the princ…
▽ More
A novel method based on Fast Neutron Resonance Transmission Radiography is proposed for non-destructive, quantitative determination of the weight percentages of oil and water in cores taken from subterranean or underwater geological formations. The ability of the method to distinguish water from oil stems from the unambiguously-specific energy dependence of the neutron cross-sections for the principal elemental constituents. Monte-Carlo simulations and initial results of experimental investigations indicate that the technique may provide a rapid, accurate and non-destructive method for quantitative evaluation of core fluids in thick intact cores, including those of tight shales for which the use of conventional core analytical approaches appears to be questionable.
△ Less
Submitted 21 February, 2016;
originally announced February 2016.
-
Physics reach of the XENON1T dark matter experiment
Authors:
The XENON collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
M. Anthony,
L. Arazi,
F. Arneodo,
C. Balan,
P. Barrow,
L. Baudis,
B. Bauermeister,
T. Berger,
P. Breur,
A. Breskin,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Bütikofer,
J. M. R. Cardoso,
M. Cervantes,
D. Cichon
, et al. (91 additional authors not shown)
Abstract:
The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds.
The total electronic recoil background in $1$ tonne fiducial volume and (…
▽ More
The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds.
The total electronic recoil background in $1$ tonne fiducial volume and ($1$, $12$) keV electronic recoil equivalent energy region, before applying any selection to discriminate between electronic and nuclear recoils, is $(1.80 \pm 0.15) \cdot 10^{-4}$ ($\rm{kg} \cdot day \cdot keV)^{-1}$, mainly due to the decay of $^{222}\rm{Rn}$ daughters inside the xenon target. The nuclear recoil background in the corresponding nuclear recoil equivalent energy region ($4$, $50$) keV, is composed of $(0.6 \pm 0.1)$ ($\rm{t} \cdot y)^{-1}$ from radiogenic neutrons, $(1.8 \pm 0.3) \cdot 10^{-2}$ ($\rm{t} \cdot y)^{-1}$ from coherent scattering of neutrinos, and less than $0.01$ ($\rm{t} \cdot y)^{-1}$ from muon-induced neutrons.
The sensitivity of XENON1T is calculated with the Profile Likelihood Ratio method, after converting the deposited energy of electronic and nuclear recoils into the scintillation and ionization signals seen in the detector. We take into account the systematic uncertainties on the photon and electron emission model, and on the estimation of the backgrounds, treated as nuisance parameters. The main contribution comes from the relative scintillation efficiency $\mathcal{L}_\mathrm{eff}$, which affects both the signal from WIMPs and the nuclear recoil backgrounds. After a $2$ y measurement in $1$ t fiducial volume, the sensitivity reaches a minimum cross section of $1.6 \cdot 10^{-47}$ cm$^2$ at m$_χ$=$50$ GeV/$c^2$.
△ Less
Submitted 15 April, 2016; v1 submitted 23 December, 2015;
originally announced December 2015.
-
First in-beam studies of a Resistive-Plate WELL gaseous multiplier
Authors:
S. Bressler,
L. Moleri,
M. Pitt,
S. Kudella,
D. C. R. Azevedo,
F. D. Amaro,
M. R. Jorge,
J. M. F. dos Santos,
J. F. C. A. Veloso,
H. Natal da Luz,
L. Arazi,
E. Olivieri,
A. Breskin
Abstract:
We present the results of the first in-beam studies of a medium size (10$\times$10 cm$^2$) Resistive-Plate WELL (RPWELL): a single-sided THGEM coupled to a pad anode through a resistive layer of high bulk resistivity ($\sim$10$^9 Ω$cm). The 6.2~mm thick (excluding readout electronics) single-stage detector was studied with 150~GeV muons and pions. Signals were recorded from 1$\times$1 cm$^2$ squar…
▽ More
We present the results of the first in-beam studies of a medium size (10$\times$10 cm$^2$) Resistive-Plate WELL (RPWELL): a single-sided THGEM coupled to a pad anode through a resistive layer of high bulk resistivity ($\sim$10$^9 Ω$cm). The 6.2~mm thick (excluding readout electronics) single-stage detector was studied with 150~GeV muons and pions. Signals were recorded from 1$\times$1 cm$^2$ square copper pads with APV25-SRS readout electronics. The single-element detector was operated in Ne\(5% $\mathrm{CH_{4}}$) at a gas gain of a few times 10$^4$, reaching 99$\%$ detection efficiency at average pad multiplicity of $\sim$1.2. Operation at particle fluxes up to $\sim$10$^4$ Hz/cm$^2$ resulted in $\sim$23$\%$ gain drop leading to $\sim$5$\%$ efficiency loss. The striking feature was the discharge-free operation, also in intense pion beams. These results pave the way towards robust, efficient large-scale detectors for applications requiring economic solutions at moderate spatial and energy resolutions.
△ Less
Submitted 20 January, 2016; v1 submitted 11 October, 2015;
originally announced October 2015.
-
Direct observation of bubble-assisted electroluminescence in liquid xenon
Authors:
E. Erdal,
L. Arazi,
V. Chepel,
M. L. Rappaport,
D. Vartsky,
A. Breskin
Abstract:
Bubble formation in liquid xenon underneath a Thick Gaseous Electron Multiplier (THGEM) electrode immersed in liquid xenon was observed with a CCD camera. With voltage across the THGEM, the appearance of bubbles was correlated with that of electroluminescence signals induced by ionization electrons from alpha-particle tracks. This confirms recent indirect evidence that the observed photons are due…
▽ More
Bubble formation in liquid xenon underneath a Thick Gaseous Electron Multiplier (THGEM) electrode immersed in liquid xenon was observed with a CCD camera. With voltage across the THGEM, the appearance of bubbles was correlated with that of electroluminescence signals induced by ionization electrons from alpha-particle tracks. This confirms recent indirect evidence that the observed photons are due to electroluminescence within a xenon vapor layer trapped under the electrode. The bubbles seem to emerge spontaneously due to heat flow from 300K into the liquid, or in a controlled manner, by locally boiling the liquid with resistive wires. Controlled bubble formation resulted in energy resolution of σ/E~7.5% for ~6,000 ionization electrons. The phenomenon could pave ways towards the conception of large-volume 'local dual-phase' noble-liquid TPCs.
△ Less
Submitted 8 September, 2015;
originally announced September 2015.
-
First results of a large-area cryogenic gaseous photomultiplier coupled to a dual-phase liquid xenon TPC
Authors:
L. Arazi,
A. E. C. Coimbra,
E. Erdal,
I. Israelashvili,
M. L. Rappaport,
S. Shchemelinin,
D. Vartsky,
J. M. F. dos Santos,
A. Breskin
Abstract:
We discuss recent advances in the development of cryogenic gaseous photomultipliers (GPM), for possible use in dark matter and other rare-event searches using noble-liquid targets. We present results from a 10 cm diameter GPM coupled to a dual-phase liquid xenon (LXe) TPC, demonstrating - for the first time - the feasibility of recording both primary ("S1") and secondary ("S2") scintillation signa…
▽ More
We discuss recent advances in the development of cryogenic gaseous photomultipliers (GPM), for possible use in dark matter and other rare-event searches using noble-liquid targets. We present results from a 10 cm diameter GPM coupled to a dual-phase liquid xenon (LXe) TPC, demonstrating - for the first time - the feasibility of recording both primary ("S1") and secondary ("S2") scintillation signals. The detector comprised a triple Thick Gas Electron Multiplier (THGEM) structure with cesium iodide photocathode on the first element; it was shown to operate stably at 180 K with gains above 10^5, providing high single-photon detection efficiency even in the presence of large alpha particle-induced S2 signals comprising thousands of photoelectrons. S1 scintillation signals were recorded with a time resolution of 1.2 ns (RMS). The energy resolution (σ/E) for S2 electroluminescence of 5.5 MeV alpha particles was ~9%, which is comparable to that obtained in the XENON100 TPC with PMTs. The results are discussed within the context of potential GPM deployment in future multi-ton noble-liquid detectors.
△ Less
Submitted 3 August, 2015;
originally announced August 2015.
-
Liquid Hole Multipliers: bubble-assisted electroluminescence in liquid xenon
Authors:
L. Arazi,
E. Erdal,
A. E. C. Coimbra,
M. L. Rappaport,
D. Vartsky,
V. Chepel,
A. Breskin
Abstract:
In this work we discuss the mechanism behind the large electroluminescence signals observed at relatively low electric fields in the holes of a Thick Gas Electron Multiplier (THGEM) electrode immersed in liquid xenon. We present strong evidence that the scintillation light is generated in xenon bubbles trapped below the THGEM holes. The process is shown to be remarkably stable over months of opera…
▽ More
In this work we discuss the mechanism behind the large electroluminescence signals observed at relatively low electric fields in the holes of a Thick Gas Electron Multiplier (THGEM) electrode immersed in liquid xenon. We present strong evidence that the scintillation light is generated in xenon bubbles trapped below the THGEM holes. The process is shown to be remarkably stable over months of operation, providing - under specific thermodynamic conditions - energy resolution similar to that of present dual-phase liquid xenon experiments. The observed mechanism may serve as the basis for the development of Liquid Hole Multipliers (LHMs), capable of producing local charge-induced electroluminescence signals in large-volume single-phase noble-liquid detectors for dark matter and neutrino physics experiments.
△ Less
Submitted 13 May, 2015; v1 submitted 9 May, 2015;
originally announced May 2015.
-
A Comprehensive Simulation Study of a Liquid-Xe Detector for Contraband Detection
Authors:
I. Israelashvili,
M. Cortesi,
D. Vartsky,
L. Arazi,
D. Bar,
E. N. Caspi,
A. Breskin
Abstract:
Recently, a new detector concept, for combined imaging and spectroscopy of fast-neutrons and gamma was presented. It encompasses a liquid-xenon (LXe) converter-scintillator coupled to a UV-sensitive gaseous Thick Gas Electron Multiplier (THGEM)-based imaging photomultiplier (GPM). In this work we present and discuss the results of a systematic computer-simulation study aiming at optimizing the typ…
▽ More
Recently, a new detector concept, for combined imaging and spectroscopy of fast-neutrons and gamma was presented. It encompasses a liquid-xenon (LXe) converter-scintillator coupled to a UV-sensitive gaseous Thick Gas Electron Multiplier (THGEM)-based imaging photomultiplier (GPM). In this work we present and discuss the results of a systematic computer-simulation study aiming at optimizing the type and performance of LXe converter. We have evaluated the detector spectral response, detection efficiency and spatial resolution for gamma-rays and neutrons in the energy range of 2-15 MeV for 50 mm thick converters consisting of plain LXe volume and LXe-filled capillaries, of Teflon, Polyethylene or hydrogen-containing Teflon (Tefzel). Neutron detection efficiencies for plain LXe, Teflon-capillaries and Tefzel-capillaries converters were about 20% over the entire energy range. In polyethylene capillaries converters the neutron detection efficiency was about 10% at 2 MeV and increased up to about 20% at 14 MeV. Detection efficiencies of gammas in Teflon, Tefzel and polyethylene converters were ~35%. The plain-LXe converter provided the highest gamma-ray detection efficiency, of ~40-50% for 2-15 MeV energy range. Optimization of LXe-filled Tefzel capillary dimensions resulted in spatial resolution of ~1.5mm (FWHM) for neutrons and up to 3.5 mm (FWHM) for gamma-rays. Simulations of radiographic images of various materials using two discrete energy gamma-rays (4.4 MeV and 15.1 MeV) and neutrons in broad energy range (2-10 MeV) were performed in order to evaluate the potential of elemental discrimination.
△ Less
Submitted 31 December, 2014;
originally announced January 2015.
-
Performance degradation of Geiger-mode APDs at cryogenic temperatures
Authors:
A. Bondar,
A. Buzulutskov,
A. Dolgov,
L. Shekhtman,
E. Shemyakina,
A. Sokolov,
A. Breskin,
D. Thers
Abstract:
Two-phase Cryogenic Avalanche Detectors (CRADs) with THGEM multipliers, optically read out with Geiger-mode APDs (GAPDs), were proposed as potential technique for charge recording in rare-event experiments. In this work we report on the degradation of the GAPD performance at cryogenic temperatures revealed in the course of the study of two-phase CRAD in Ar, with combined THGEM/GAPD-matrix multipli…
▽ More
Two-phase Cryogenic Avalanche Detectors (CRADs) with THGEM multipliers, optically read out with Geiger-mode APDs (GAPDs), were proposed as potential technique for charge recording in rare-event experiments. In this work we report on the degradation of the GAPD performance at cryogenic temperatures revealed in the course of the study of two-phase CRAD in Ar, with combined THGEM/GAPD-matrix multiplier; the GAPDs recorded secondary scintillation photons from the THGEM holes in the Near Infrared. The degradation effect, namely the loss of the GAPD pulse amplitude, depended on the incident X-ray photon flux. The critical counting rate of photoelectrons produced at the 4.4 mm2 GAPD, degrading its performance at 87 K, was estimated as 10000 per second. This effect was shown to result from the considerable increase of the pixel quenching resistor of this CPTA-made GAPD type. Though not affecting low-rate rare-event experiments, the observed effect may impose some limitations on the performance of CRADs with GAPD-based optical readout at higher-rate applications.
△ Less
Submitted 18 June, 2014;
originally announced June 2014.
-
Conceptual design and simulation of a water Cherenkov muon veto for the XENON1T experiment
Authors:
E. Aprile,
F. Agostini,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
M. Auger,
C. Balan,
P. Barrow,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
K. Bokeloh,
A. Breskin,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni
, et al. (66 additional authors not shown)
Abstract:
XENON is a dark matter direct detection project, consisting of a time projection chamber (TPC) filled with liquid xenon as detection medium. The construction of the next generation detector, XENON1T, is presently taking place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a sensitivity to spin-independent cross sections of $2 \cdot 10^{-47} ~ \mathrm{cm}^{\mathrm{2}}$ for W…
▽ More
XENON is a dark matter direct detection project, consisting of a time projection chamber (TPC) filled with liquid xenon as detection medium. The construction of the next generation detector, XENON1T, is presently taking place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a sensitivity to spin-independent cross sections of $2 \cdot 10^{-47} ~ \mathrm{cm}^{\mathrm{2}}$ for WIMP masses around 50 GeV/c$^{2}$, which requires a background reduction by two orders of magnitude compared to XENON100, the current generation detector. An active system that is able to tag muons and muon-induced backgrounds is critical for this goal. A water Cherenkov detector of $\sim$10 m height and diameter has been therefore developed, equipped with 8 inch photomultipliers and cladded by a reflective foil. We present the design and optimization study for this detector, which has been carried out with a series of Monte Carlo simulations. The muon veto will reach very high detection efficiencies for muons ($>99.5%$) and showers of secondary particles from muon interactions in the rock ($>70%$). Similar efficiencies will be obtained for XENONnT, the upgrade of XENON1T, which will later improve the WIMP sensitivity by another order of magnitude. With the Cherenkov water shield studied here, the background from muon-induced neutrons in XENON1T is negligible.
△ Less
Submitted 25 February, 2015; v1 submitted 9 June, 2014;
originally announced June 2014.
-
A concept for laboratory studies of radiation detectors over a broad dynamic-range: instabilities evaluation in THGEM-structures
Authors:
S. Bressler,
L. Moleri,
L. Arazi,
E. Erdal,
A. Rubin,
M. Pitt,
A. Breskin
Abstract:
A simple methodology for evaluating the dynamic-range of gas avalanche detectors in the laboratory is presented and discussed. It comprises two tools: a charge injector of tunable gain which transfers radiation-induced amplified electron swarms to the investigated detector to mimic events with well defined primary-ionization spectra, and a systematic approach for measuring the detector's discharge…
▽ More
A simple methodology for evaluating the dynamic-range of gas avalanche detectors in the laboratory is presented and discussed. It comprises two tools: a charge injector of tunable gain which transfers radiation-induced amplified electron swarms to the investigated detector to mimic events with well defined primary-ionization spectra, and a systematic approach for measuring the detector's discharge probability. The methodology, applicable to a broad range of detectors, is applied here for instability studies in various single-stage THGEM and THGEM-WELL structures. The results indicate upon a somewhat larger attainable dynamic range in a single-stage THGEM operated with additional multiplication in the induction gap.
△ Less
Submitted 5 November, 2013; v1 submitted 2 November, 2013;
originally announced November 2013.
-
Laboratory studies of THGEM-based WELL structures with resistive anodes
Authors:
L. Arazi,
M. Pitt,
S. Bressler,
L. Moleri,
A. Rubin,
A. Breskin
Abstract:
In this work we investigate three variants of single amplification-stage detector elements; they comprise THGEM electrodes closed at their bottom with metallic or resistive anodes to form WELL-type configurations. We present the results of a comparative study of the Thick-WELL (THWELL), Resistive-WELL (RWELL) and Segmented Resistive WELL (SRWELL), focusing on their performance in terms of spark-qu…
▽ More
In this work we investigate three variants of single amplification-stage detector elements; they comprise THGEM electrodes closed at their bottom with metallic or resistive anodes to form WELL-type configurations. We present the results of a comparative study of the Thick-WELL (THWELL), Resistive-WELL (RWELL) and Segmented Resistive WELL (SRWELL), focusing on their performance in terms of spark-quenching capability, gain variation with position and counting rate, pulse shapes and signal propagation to neighboring readout pads; the study included both 30x30 and 100x100 mm$^2$ detectors. It was shown that the WELL structures with resistive anodes offer stable operation even in a highly ionizing environment, with effective spark quenching, as well as higher gain than the standard THGEM/induction-gap configuration. Cross talk between neighboring readout pads was shown to be effectively eliminated in the segmented detector with a conductive grid underneath the resistive layer. The latter multiplier should allow for the design of very thin detectors, e.g. sampling elements in digital hadronic calorimeters planned for experiments in future linear colliders.
△ Less
Submitted 23 October, 2013;
originally announced October 2013.
-
First observation of liquid-xenon proportional electroluminescence in THGEM holes
Authors:
L. Arazi,
A. E. C. Coimbra,
R. Itay,
H. Landsman,
L. Levinson,
M. L. Rappaport,
D. Vartsky,
A. Breskin
Abstract:
Radiation-induced proportional-electroluminescence UV signals, emitted from the holes of a Thick Gas Electron Multiplier (THGEM) electrode immersed in liquid xenon, were recorded with a PMT for the first time. Significant photon yields were observed using a 0.4 mm thick electrode with 0.3 mm diameter holes; at 2 kV across the THGEM the photon yield was estimated to be ~600 UV photons/electron over…
▽ More
Radiation-induced proportional-electroluminescence UV signals, emitted from the holes of a Thick Gas Electron Multiplier (THGEM) electrode immersed in liquid xenon, were recorded with a PMT for the first time. Significant photon yields were observed using a 0.4 mm thick electrode with 0.3 mm diameter holes; at 2 kV across the THGEM the photon yield was estimated to be ~600 UV photons/electron over 4pi This may pave the way towards the realization of novel single-phase noble-liquid radiation detectors incorporating liquid hole-multipliers (LHM); their concept is presented.
△ Less
Submitted 15 October, 2013;
originally announced October 2013.
-
Recent advances with THGEM detectors
Authors:
S. Bressler,
L. Arazi,
L. Moleri,
M. Pitt,
A. Rubin,
A. Breskin
Abstract:
The Thick Gaseous Electron Multiplier (THGEM) is a simple and robust electrode suitable for large area detectors. In this work the results of extensive comparative studies of the physical properties of different THGEM-based structures are reviewed. The focus is on newly suggested THGEM-like WELL configurations as well as on recently developed characterization methods. The WELL structures are singl…
▽ More
The Thick Gaseous Electron Multiplier (THGEM) is a simple and robust electrode suitable for large area detectors. In this work the results of extensive comparative studies of the physical properties of different THGEM-based structures are reviewed. The focus is on newly suggested THGEM-like WELL configurations as well as on recently developed characterization methods. The WELL structures are single-sided THGEM electrodes directly coupled to different anode readout electrodes. The structures differ by the coupling concept of the bottom THGEM electrode to the metallic readout pads: a Thick WELL (THWELL) with direct coupling; the Resistive WELL (RWELL) and the Segmented Resistive WELL (SRWELL) coupled through thin resistive films deposited on insulating sheets and a Resistive-Plate WELL (RPWELL) coupled through a plate of high bulk resistivity. The results are compared to that of traditional double-sided THGEM electrodes followed by induction gaps - in some cases with moderate additional multiplication within the gap. We compare the different configurations in terms of gain, avalanche extension, discharge-rate and magnitude as well as rate capabilities over a broad dynamic range - exploiting a method that mimics highly ionizing particles in the laboratory. We report on recent studies of avalanche distribution in THGEM holes using optical readout.
△ Less
Submitted 15 October, 2013;
originally announced October 2013.