First measurement of the $^{10}{\rm B}(α,n)^{13}{\rm N}$ reaction in an inertial confinement fusion implosion at the National Ignition Facility: Initial steps toward the development of a radiochemistry mix diagnostic
Authors:
D. Lonardoni,
J. P. Sauppe,
S. H. Batha,
N. Birge,
T. Bredeweg,
M. Freeman,
V. Geppert-Kleinrath,
M. E. Gooden,
A. C. Hayes,
H. Huang,
G. Jungman,
B. D. Keenan,
L. Kot,
K. D. Meaney,
T. Murphy,
C. Velsko,
C. B. Yeamans,
H. D. Whitley,
C. Wilde,
J. B. Wilhelmy
Abstract:
We report the first measurement of the $^{10}{\rm B}(α,n)^{13}{\rm N}$ reaction in a polar-direct-drive exploding pusher (PDXP) at the National Ignition Facility (NIF). This work is motivated by the need to develop alternative mix diagnostics, radiochemistry being the focus here. The target is composed of a $65/35\,\rm at.\,\%$ deuterium-tritium (DT) fill surrounded by a roughly $30\,μ\rm m$ thick…
▽ More
We report the first measurement of the $^{10}{\rm B}(α,n)^{13}{\rm N}$ reaction in a polar-direct-drive exploding pusher (PDXP) at the National Ignition Facility (NIF). This work is motivated by the need to develop alternative mix diagnostics, radiochemistry being the focus here. The target is composed of a $65/35\,\rm at.\,\%$ deuterium-tritium (DT) fill surrounded by a roughly $30\,μ\rm m$ thick beryllium ablator. The inner portion of the beryllium ablator is doped with $10\,\rm at.\,\%$ of $^{10}{\rm B}$. Radiation-hydrodynamics calculations were performed in 1D to optimize both the remaining boron rho-R and the DT neutron yield. A charged-particle transport post-processor has been developed to study $α$-induced reactions on the ablator material. Results indicate a large $^{13}{\rm N}$ production from $α$-induced reactions on $^{10}{\rm B}$, measurable by the radiochemical analysis of gaseous samples system at the NIF. The PDXP target N201115-001 was successfully fielded on the NIF, and nitrogen from the $^{10}{\rm B}(α,n)^{13}{\rm N}$ reaction was measured. The $^{13}{\rm N}$ production yield, as well as the DT neutron yield, was, however, lower than expected. Some of the reduced yields can be explained by the oblate shape, but the ratios of the various radiochemical signals are not commensurate with expectations based on a simple reduction of the 1D results. Preliminary 2D radiation-hydrodynamics computations are consistent with the experimental measurements, and work is ongoing to extend the radiochemistry analysis into higher dimensions.
△ Less
Submitted 17 May, 2022; v1 submitted 18 November, 2021;
originally announced November 2021.
-
Isotope Harvesting at FRIB: Additional opportunities for scientific discovery
Authors:
E. Paige Abel,
Mikael Avilov,
Virginia Ayres,
Eva Birnbaum,
Georg Bollen,
Greg Bonito,
Todd Bredeweg,
Hannah Clause,
Aaron Couture,
Joe DeVore,
Matt Dietrich,
Paul Ellison,
Jonathan Engle,
Richard Ferrieri,
Jonathan Fitzsimmons,
Moshe Friedman,
Dali Georgobiani,
Stephen Graves,
John Greene,
Suzanne Lapi,
C. Shaun Loveless,
Paul Mantica,
Tara Mastren,
Cecilia Martinez-Gomez,
Sean McGuinness
, et al. (15 additional authors not shown)
Abstract:
The Facility for Rare Isotope Beams (FRIB) at Michigan State University provides a unique opportunity to access some of the nation's most specialized scientific resources: radioisotopes. An excess of useful radioisotopes will be formed as FRIB fulfills its basic science mission of providing rare isotope beams. In order for the FRIB beams to reach high-purity, many of the isotopes are discarded and…
▽ More
The Facility for Rare Isotope Beams (FRIB) at Michigan State University provides a unique opportunity to access some of the nation's most specialized scientific resources: radioisotopes. An excess of useful radioisotopes will be formed as FRIB fulfills its basic science mission of providing rare isotope beams. In order for the FRIB beams to reach high-purity, many of the isotopes are discarded and go unused. If harvested, the unused isotopes could enable cutting-edge research for diverse applications ranging from medical therapy and diagnosis to nuclear security. Given that FRIB will have the capability to create about 80 percent of all possible atomic nuclei, harvesting at FRIB will provide a fast path for access to a vast array of isotopes of interest in basic and applied science investigations. To fully realize this opportunity, infrastructure investment is required to enable harvesting and purification of otherwise unused isotopes. An investment in isotope harvesting at FRIB will provide the nation with a powerful resource for development of crucial isotope applications.
△ Less
Submitted 7 December, 2018;
originally announced December 2018.
-
The $^{63}$Ni(n,$γ$) cross section measured with DANCE
Authors:
M. Weigand,
T. A. Bredeweg,
A. Couture,
K. Göbel,
T. Heftrich,
M. Jandel,
F. Käppeler,
C. Lederer,
N. Kivel,
G. Korschinek,
M. Krticka,
J. M. O'Donnell,
J. Ostermöller,
R. Plag,
R. Reifarth,
D. Schumann,
J. L. Ullmann,
A. Wallner
Abstract:
The neutron capture cross section of the s-process branch nucleus $^{63}$Ni affects the abundances of other nuclei in its region, especially $^{63}$Cu and $^{64}$Zn. In order to determine the energy dependent neutron capture cross section in the astrophysical energy region, an experiment at the Los Alamos National Laboratory has been performed using the calorimetric 4$π$ BaF$_2$ array DANCE. The (…
▽ More
The neutron capture cross section of the s-process branch nucleus $^{63}$Ni affects the abundances of other nuclei in its region, especially $^{63}$Cu and $^{64}$Zn. In order to determine the energy dependent neutron capture cross section in the astrophysical energy region, an experiment at the Los Alamos National Laboratory has been performed using the calorimetric 4$π$ BaF$_2$ array DANCE. The (n,$γ$) cross section of $^{63}$Ni has been determined relative to the well known $^{197}$Au standard with uncertainties below 15%. Various $^{63}$Ni resonances have been identified based on the Q-value. Furthermore, the s-process sensitivity of the new values was analyzed with the new network calculation tool NETZ.
△ Less
Submitted 7 December, 2015;
originally announced December 2015.
-
Development of position-sensitive time-of-flight spectrometer for fission fragment research
Authors:
C. W. Arnold,
F. Tovesson,
K. Meierbachtol,
T. Bredeweg,
M. Jandel,
H. J. Jorgenson,
A. Laptev,
G. Rusev,
D. W. Shields,
M. White,
R. E. Blakeley,
D. M. Mader,
A. A. Hecht
Abstract:
A position-sensitive, high-resolution time-of-flight detector for fission fragments has been developed. The SPectrometer for Ion DEterminiation in fission Research (SPIDER) is a $2E-2v$ spectrometer designed to measure the mass of light fission fragments to a single mass unit. The time pick-off detector pairs to be used in SPIDER have been tested with $α$-particles from $^{229}$Th and its decay ch…
▽ More
A position-sensitive, high-resolution time-of-flight detector for fission fragments has been developed. The SPectrometer for Ion DEterminiation in fission Research (SPIDER) is a $2E-2v$ spectrometer designed to measure the mass of light fission fragments to a single mass unit. The time pick-off detector pairs to be used in SPIDER have been tested with $α$-particles from $^{229}$Th and its decay chain and $α$-particles and spontaneous fission fragments from $^{252}$Cf. Each detector module is comprised of a thin electron conversion foil, electrostatic mirror, microchannel plates, and delay-line anodes. Particle trajectories on the order of 700 mm are determined accurately to within 0.7 mm. Flight times on the order of 70 ns were measured with 200 ps resolution FWHM. Computed particle velocities are accurate to within 0.06 mm/ns corresponding to precision of 0.5%. An ionization chamber capable of 400 keV energy resolution coupled with the velocity measurements described here will pave the way for modestly efficient measurements of light fission fragments with unit mass resolution.
△ Less
Submitted 6 March, 2014;
originally announced March 2014.
-
Background identification and suppression for the measurement of (n,g) reactions with the DANCE array at LANSCE
Authors:
R. Reifarth,
T. A. Bredeweg,
A. Alpizar-Vicente,
J. C. Browne,
E. -I. Esch,
U. Greife,
R. C. Haight,
R. Hatarik,
A. Kronenberg,
J. M. O'Donnell,
R. S. Rundberg,
J. L. Ullmann,
D. J. Vieira,
J. B. Wilhelmy,
J. M. Wouters
Abstract:
In the commissioning phase of the DANCE project (Detector for Advanced Neutron Capture Experiments) measurements have been performed with special emphasis on the identification and suppression of possible backgrounds for the planned (n,g) experiments. This report describes several background sources, observed in the experiment or anticipated from simulations, which will need to be suppressed in th…
▽ More
In the commissioning phase of the DANCE project (Detector for Advanced Neutron Capture Experiments) measurements have been performed with special emphasis on the identification and suppression of possible backgrounds for the planned (n,g) experiments. This report describes several background sources, observed in the experiment or anticipated from simulations, which will need to be suppressed in this and in similar detectors that are planned at other facilities. First successes are documented in the suppression of background from scattered neutrons captured in the detector as well as from the internal radiation. Experimental results and simulations using the GEANT code are compared.
△ Less
Submitted 7 October, 2013;
originally announced October 2013.
-
Abrupt Change in Radiation-Width Distribution for 147Sm Neutron Resonances
Authors:
P. E. Koehler,
R. Reifarth,
J. L. Ullmann,
T. A. Bredeweg,
J. M. O'Donnell,
R. S. Rundberg,
D. J. Vieira,
J. M. Wouters
Abstract:
We obtained total radiation widths of s-wave resonances through R-matrix analysis of 147Sm(n,gamma) cross-sections. Distributions of these widths differ markedly for resonances below and above 300 eV, in stark contrast to long-established theory. We show that this change, as well as a similar change in the neutron-width distribution reported previously, are reflected in abrupt increases in both th…
▽ More
We obtained total radiation widths of s-wave resonances through R-matrix analysis of 147Sm(n,gamma) cross-sections. Distributions of these widths differ markedly for resonances below and above 300 eV, in stark contrast to long-established theory. We show that this change, as well as a similar change in the neutron-width distribution reported previously, are reflected in abrupt increases in both the average 147Sm(n,gamma) cross section and fluctuations about the average near 300 eV. Such effects could have important consequences for applications such as nuclear astrophysics and nuclear criticality safety.
△ Less
Submitted 1 February, 2012;
originally announced February 2012.
-
Non-Statistical Effects in Neutron Capture
Authors:
P. E. Koehler,
T. A. Bredeweg,
K. H. Guber,
J. A. Harvey,
J. M. ODonnell,
R. Reifarth,
R. S. Rundberg,
J. L. Ullmann,
D. J. Vieira,
D. Wiarda,
J. M. Wouters
Abstract:
There have been many reports of non-statistical effects in neutron-capture measurements. However, reports of deviations of reduced-neutron-width distributions from the expected Porter-Thomas (PT) shape largely have been ignored. Most of these deviations have been reported for odd-A nuclides. Because reliable spin (J) assignments have been absent for most resonances for such nuclides, it is possi…
▽ More
There have been many reports of non-statistical effects in neutron-capture measurements. However, reports of deviations of reduced-neutron-width distributions from the expected Porter-Thomas (PT) shape largely have been ignored. Most of these deviations have been reported for odd-A nuclides. Because reliable spin (J) assignments have been absent for most resonances for such nuclides, it is possible that reported deviations from PT might be due to incorrect J assignments. We recently developed a new method for measuring spins of neutron resonances by using the DANCE detector at LANSCE. Measurements made with a 147Sm sample allowed us to determine spins of almost all known resonances below 1 keV. Furthermore, analysis of these data revealed that the reduced-neutron-width distribution was in good agreement with PT for resonances below 350 eV, but in disagreement with PT for resonances between 350 and 700 eV. Our previous (n,alpha) measurements had revealed that the alpha strength function also changes abruptly at this energy. There currently is no known explanation for these two non-statistical effects. Recently, we have developed another new method for determining the spins of neutron resonances. To implement this technique required a small change (to record pulse-height information for coincidence events) to a much simpler apparatus: A pair of C6D6 gamma-ray detectors which we have employed for many years to measure neutron-capture cross sections at ORELA. Measurements with a 95Mo sample revealed that not only does the method work very well for determining spins, but it also makes possible parity assignments. Taken together, these new techniques at LANSCE and ORELA could be very useful for further elucidation of non-statistical effects.
△ Less
Submitted 16 September, 2008;
originally announced September 2008.
-
Spin measurements for 147Sm+n resonances: Further evidence for non-statistical effects
Authors:
P. E. Koehler,
J. L. Ullmann,
T. A. Bredeweg,
J. M. O`Donnell,
R. Reifarth,
R. S. Rundberg,
D. J. Vieira,
J. M. Wouters
Abstract:
We have determined the spins J of resonances in the 147Sm(n,gamma) reaction by measuring multiplicities of gamma-ray cascades following neutron capture. Using this technique, we were able to determine J values for all but 14 of the 140 known resonances below En = 1 keV, including 41 firm J assignments for resonances whose spins previously were either unknown or tentative. These new spin assignme…
▽ More
We have determined the spins J of resonances in the 147Sm(n,gamma) reaction by measuring multiplicities of gamma-ray cascades following neutron capture. Using this technique, we were able to determine J values for all but 14 of the 140 known resonances below En = 1 keV, including 41 firm J assignments for resonances whose spins previously were either unknown or tentative. These new spin assignments, together with previously determined resonance parameters, allowed us to extract separate level spacings and neutron strength functions for J = 3 and 4 resonances. Furthermore, several statistical test of the data indicate that very few resonances of either spin have been missed below En = 700eV. Because a non-statistical effect recently was reported near En = 350 eV from an analysis of 147Sm(n,alpha) data, we divided the data into two regions; 0 < En < 350 eV and 350 < En < 700 eV. Using neutron widths from a previous measurement and published techniques for correcting for missed resonances and for testing whether data are consistent with a Porter-Thomas distribution, we found that the reduced-neutron-width distribution for resonances below 350 eV is consistent with the expected Porter-Thomas distribution. On the other hand, we found that reduced-neutron-width data in the 350 < En < 700 eV region are inconsistent with a Porter-Thomas distribution, but in good agreement with a chi-squared distribution having two or more degrees of freedom. We discuss possible explanations for these observed non-statistical effects and their possible relation to similar effects previously observed in other nuclides.
△ Less
Submitted 1 August, 2007;