High-power closed-cycle $^4$He cryostat with top-loading sample exchange
Authors:
F. M. Piegsa,
B. van den Brandt,
K. Kirch
Abstract:
We report on the development of a versatile cryogen-free laboratory cryostat based upon a commercial pulse tube cryocooler. It provides enough cooling power for continuous recondensation of circulating $^4$He gas at a condensation pressure of approximately 250~mbar. Moreover, the cryostat allows for exchange of different cryostat-inserts as well as fast and easy "wet" top-loading of samples direct…
▽ More
We report on the development of a versatile cryogen-free laboratory cryostat based upon a commercial pulse tube cryocooler. It provides enough cooling power for continuous recondensation of circulating $^4$He gas at a condensation pressure of approximately 250~mbar. Moreover, the cryostat allows for exchange of different cryostat-inserts as well as fast and easy "wet" top-loading of samples directly into the 1 K pot with a turn-over time of less than 75~min. Starting from room temperature and using a $^4$He cryostat-insert, a base temperature of 1.0~K is reached within approximately seven hours and a cooling power of 250~mW is established at 1.24~K.
△ Less
Submitted 30 August, 2017;
originally announced August 2017.
-
Polarized Neutron Laue Diffraction on a Crystal Containing Dynamically Polarized Proton Spins
Authors:
F. M. Piegsa,
M. Karlsson,
B. van den Brandt,
C. J. Carlile,
E. M. Forgan,
P. Hautle,
J. A. Konter,
G. J. McIntyre,
O. Zimmer
Abstract:
We report on a polarized-neutron Laue diffraction experiment on a single crystal of neodynium doped lanthanum magnesium nitrate hydrate containing polarized proton spins. By using dynamic nuclear polarization to polarize the proton spins, we demonstrate that the intensities of the Bragg peaks can be enhanced or diminished significantly, whilst the incoherent background, due to proton spin disorder…
▽ More
We report on a polarized-neutron Laue diffraction experiment on a single crystal of neodynium doped lanthanum magnesium nitrate hydrate containing polarized proton spins. By using dynamic nuclear polarization to polarize the proton spins, we demonstrate that the intensities of the Bragg peaks can be enhanced or diminished significantly, whilst the incoherent background, due to proton spin disorder, is reduced. It follows that the method offers unique possibilities to tune continuously the contrast of the Bragg reflections and thereby represents a new tool for increasing substantially the signal-to-noise ratio in neutron diffraction patterns of hydrogenous matter.
△ Less
Submitted 9 October, 2012;
originally announced October 2012.
-
Accumulation and extraction of ultracold neutrons from a superfluid helium converter coated with fluorinated grease
Authors:
O. Zimmer,
P. Schmidt-Wellenburg,
M. Assmann,
M. Fertl,
J. Klenke,
S. Mironov,
H. -F. Wirth,
B. van den Brandt
Abstract:
We report experiments on the production of ultracold neutrons (UCN) in a converter of superfluid helium coated with fluorinated grease. We employed our technique of window-free extraction of accumulated UCN from the helium, in which they were produced by downscattering neutrons of a cold beam from the Munich research reactor. The time constant for UCN passage through the same extraction aperture…
▽ More
We report experiments on the production of ultracold neutrons (UCN) in a converter of superfluid helium coated with fluorinated grease. We employed our technique of window-free extraction of accumulated UCN from the helium, in which they were produced by downscattering neutrons of a cold beam from the Munich research reactor. The time constant for UCN passage through the same extraction aperture as in a previous experiment was a factor two shorter, despite a lower mean velocity of the accumulated UCN in the present experiments. A time-of-flight measurement of the cold neutron spectrum incident on the converter allowed us to estimate the multi-phonon contribution to the UCN production. The UCN production rate inferred from two methods agrees with the theoretical expectation.
△ Less
Submitted 31 January, 2008;
originally announced January 2008.
-
A superfluid helium converter for accumulation and extraction of ultracold neutrons
Authors:
O. Zimmer,
K. Baumann,
M. Fertl,
B. Franke,
S. Mironov,
C. Plonka,
D. Rich,
P. Schmidt-Wellenburg,
H. -F. Wirth,
B. van den Brandt
Abstract:
We report the first successful extraction of accumulated ultracold neutrons (UCN) from a converter of superfluid helium, in which they were produced by downscattering neutrons of a cold beam from the Munich research reactor. Windowless UCN extraction is performed in vertical direction through a mechanical cold valve. This prototype of a versatile UCN source is comprised of a novel cryostat desig…
▽ More
We report the first successful extraction of accumulated ultracold neutrons (UCN) from a converter of superfluid helium, in which they were produced by downscattering neutrons of a cold beam from the Munich research reactor. Windowless UCN extraction is performed in vertical direction through a mechanical cold valve. This prototype of a versatile UCN source is comprised of a novel cryostat designed to keep the source portable and to allow for rapid cooldown. We measured time constants for UCN storage and extraction into a detector at room temperature, with the converter held at various temperatures between 0.7 and 1.3 K. The UCN production rate inferred from the count rate of extracted UCN is close to the theoretical expectation.
△ Less
Submitted 27 May, 2007;
originally announced May 2007.
-
Low Energy Analyzing Powers in Pion-Proton Elastic Scattering
Authors:
R. Meier,
M. Cröni,
R. Bilger,
B. van den Brandt,
J. Breitschopf,
H. Clement,
J. R. Comfort,
H. Denz,
A. Erhardt,
K. Föhl,
E. Friedman,
J. Gräter,
P. Hautle,
G. J. Hofman,
J. A. Konter,
S. Mango,
J. Pätzold,
M. M. Pavan,
G. J. Wagner,
F. von Wrochem
Abstract:
Analyzing powers of pion-proton elastic scattering have been measured at PSI with the Low Energy Pion Spectrometer LEPS as well as a novel polarized scintillator target. Angular distributions between 40 and 120 deg (c.m.) were taken at 45.2, 51.2, 57.2, 68.5, 77.2, and 87.2 MeV incoming pion kinetic energy for pi+ p scattering, and at 67.3 and 87.2 MeV for pi- p scattering. These new measurement…
▽ More
Analyzing powers of pion-proton elastic scattering have been measured at PSI with the Low Energy Pion Spectrometer LEPS as well as a novel polarized scintillator target. Angular distributions between 40 and 120 deg (c.m.) were taken at 45.2, 51.2, 57.2, 68.5, 77.2, and 87.2 MeV incoming pion kinetic energy for pi+ p scattering, and at 67.3 and 87.2 MeV for pi- p scattering. These new measurements constitute a substantial extension of the polarization data base at low energies. Predictions from phase shift analyses are compared with the experimental results, and deviations are observed at low energies.
△ Less
Submitted 25 February, 2004;
originally announced February 2004.
-
The spin-dependent nd scattering length - a proposed high-accuracy measurement
Authors:
B. van den Brandt,
H. W. Griesshammer,
P. Hautle,
J. Kohlbrecher,
J. A. Konter,
O. Zimmer
Abstract:
The understanding of few-nucleon systems at low energies is essential, e.g. for accurate predictions of element abundances in big-bang and stellar fusion. Novel effective field theories, taking only nucleons, or nucleons and pions as explicit degrees of freedom, provide a systematic approach, permitting an estimate of theoretical uncertainties. Basic constants parameterising the short range phys…
▽ More
The understanding of few-nucleon systems at low energies is essential, e.g. for accurate predictions of element abundances in big-bang and stellar fusion. Novel effective field theories, taking only nucleons, or nucleons and pions as explicit degrees of freedom, provide a systematic approach, permitting an estimate of theoretical uncertainties. Basic constants parameterising the short range physics are derived from only a handful of experimental values. The doublet neutron scattering length a_2 of the deuteron is particularly sensitive to a three-nucleon contact interaction, but experimentally known with only 6% accuracy. It can be deduced from the two experimentally accessible parameters of the nd scattering length. We plan to measure the poorly known "incoherent" nd scattering length a_{i,d} with 10^{-3} accuracy, using a Ramsey apparatus for pseudomagnetic precession with a cold polarised neutron beam at PSI. A polarised target containing both deuterons and protons will permit a measurement relative to the incoherent np scattering length, which is know experimentally with an accuracy of 2.4\times 10^{-4}.
△ Less
Submitted 23 January, 2004;
originally announced January 2004.
-
Search for the Hypothetical pi -> mu x Decay
Authors:
R. Bilger,
H. Clement,
A. Denig,
K. Fohl,
P. Hautle,
W. Kluge,
J. A. Konter,
G. Kurz,
S. Mango,
D. Schapler,
F. Schonleber,
U. Siodlaczek,
B. van den Brandt,
G. J. Wagner,
R. Wieser
Abstract:
The KARMEN collaboration has reported the possible observation of a hitherto unknown neutral and weakly interacting particle x, which is produced in the decay pi -> mu + x with a mass m(x) = 33.9 MeV. We have searched for this hypothetical decay branch by studying muons from pion decay in flight with the LEPS spectrometer at the piE3 channel at PSI and find branching ratios BR(pi- to mu- anti-x)…
▽ More
The KARMEN collaboration has reported the possible observation of a hitherto unknown neutral and weakly interacting particle x, which is produced in the decay pi -> mu + x with a mass m(x) = 33.9 MeV. We have searched for this hypothetical decay branch by studying muons from pion decay in flight with the LEPS spectrometer at the piE3 channel at PSI and find branching ratios BR(pi- to mu- anti-x) < 4e-7 and BR(pi+ to mu+ x) < 7e-8 (95\% C.L.). Together with the limit BR > 2e-8 derived in a recent theoretical paper our result would leave only a narrow region for the existence of x if it is a heavy neutrino.
△ Less
Submitted 18 August, 1995;
originally announced August 1995.
-
Detection of nuclear recoils in prototype dark matter detectors, made from Al, Sn and Zn Superheated Superconducting Granules
Authors:
M. Abplanalp,
C. Berger,
G. Czapek,
U. Diggelmann,
M. Furlan,
A. Gabutti,
S. Janos,
U. Moser,
R. Pozzi,
K. Pretzl,
K. Schmiemann,
D. Perret-Gallix,
B. van den Brandt,
J. A. Konter,
S. Mango
Abstract:
This work is part of an ongoing project to develop a Superheated Superconducting Granule (SSG) detector for cold dark matter and neutrinos. The response of SSG devices to nuclear recoils has been explored irradiating SSG detectors with a 70MeV neutron beam. The aim of the experiment was to test the sensitivity of Sn, Al and Zn SSG detectors to nuclear recoil energies down to a few keV. The detec…
▽ More
This work is part of an ongoing project to develop a Superheated Superconducting Granule (SSG) detector for cold dark matter and neutrinos. The response of SSG devices to nuclear recoils has been explored irradiating SSG detectors with a 70MeV neutron beam. The aim of the experiment was to test the sensitivity of Sn, Al and Zn SSG detectors to nuclear recoil energies down to a few keV. The detector consisted of a hollow teflon cylinder (0.1cm$^3$ inner volume) filled with tiny superconducting metastable granules embedded in a dielectric medium. The nuclear recoil energies deposited in the SSG were determined measuring the neutron scattering angles with a neutron hodoscope. Coincidences in time between the SSG and the hodoscope signals have been clearly established. In this paper the results of the neutron irradiation experiments at different SSG intrinsic thresholds are discussed and compared to Monte Carlo simulations. The results show that SSG are sensitive to recoil energies down to $\sim$1keV. The limited angular resolution of the neutron hodoscope prevented us from measuring the SSG sensitivity to even lower recoil energies.
△ Less
Submitted 17 November, 1994;
originally announced November 1994.