-
Overhaul and Installation of the ICARUS-T600 Liquid Argon TPC Electronics for the FNAL Short Baseline Neutrino Program
Authors:
L. Bagby,
B. Baibussinov,
B. Behera,
V. Bellini,
R. Benocci,
M. Betancourt,
M. Bettini,
M. Bonesini,
T. Boone,
A. Braggiotti,
J. D. Brown,
H. Budd,
F. Calaon,
L. Castellani,
S. Centro,
A. G. Cocco,
M. Convery,
F. Fabris,
A. Falcone,
C. Farnese,
A. Fava,
F. Fichera,
M. Giarin,
D. Gibin,
A. Guglielmi
, et al. (39 additional authors not shown)
Abstract:
The ICARUS T600 liquid argon (LAr) time projection chamber (TPC) underwent a major overhaul at CERN in 2016-2017 to prepare for the operation at FNAL in the Short Baseline Neutrino (SBN) program. This included a major upgrade of the photo-multiplier system and of the TPC wire read-out electronics. The full TPC wire read-out electronics together with the new wire biasing and interconnection scheme…
▽ More
The ICARUS T600 liquid argon (LAr) time projection chamber (TPC) underwent a major overhaul at CERN in 2016-2017 to prepare for the operation at FNAL in the Short Baseline Neutrino (SBN) program. This included a major upgrade of the photo-multiplier system and of the TPC wire read-out electronics. The full TPC wire read-out electronics together with the new wire biasing and interconnection scheme are described. The design of a new signal feed-through flange is also a fundamental piece of this overhaul whose major feature is the integration of all electronics components onto the signal flange. Initial functionality tests of the full TPC electronics chain installed in the T600 detector at FNAL are also described.
△ Less
Submitted 25 November, 2020; v1 submitted 5 October, 2020;
originally announced October 2020.
-
Design and implementation of the new scintillation light detection system of ICARUS T600
Authors:
B. Ali-Mohammadzadeh,
M. Babicz,
W. Badgett,
L. Bagby,
V. Bellini,
R. Benocci,
M. Bonesini,
A. Braggiotti,
S. Centro,
A. Chatterjee,
A. G. Cocco,
M. Diwan,
A. Falcone,
C. Farnese,
A. Fava,
D. Gibin,
A. Guglielmi,
W. Ketchum,
U. Kose,
A. Menegolli,
G. Meng,
C. Montanari,
M. Nessi,
F. Pietropaolo,
A. Rappoldi
, et al. (15 additional authors not shown)
Abstract:
ICARUS T600 is the far detector of the Short Baseline Neutrino program at Fermilab(USA), which foresees three Liquid Argon Time Projection Chambers along the Booster Neutrino Beam line to search for LSND-like sterile neutrino signal. The T600 detector underwent a significant overhauling process at CERN, introducing new technological developments while maintaining the already achieved performances.…
▽ More
ICARUS T600 is the far detector of the Short Baseline Neutrino program at Fermilab(USA), which foresees three Liquid Argon Time Projection Chambers along the Booster Neutrino Beam line to search for LSND-like sterile neutrino signal. The T600 detector underwent a significant overhauling process at CERN, introducing new technological developments while maintaining the already achieved performances. The realization of a new liquid argon scintillation light detection system is a primary task of the detector overhaul. As the detector will be subject to a huge flux of cosmic rays, the light detection system should allow the 3D reconstruction of events contributing to the identification of neutrino interactions in the beam spill gate. The design and implementationof the new scintillation light detection system of ICARUS T600 is described.
△ Less
Submitted 1 September, 2020; v1 submitted 9 June, 2020;
originally announced June 2020.
-
Test and characterization of 400 Hamamatsu R5912-MOD photomultiplier tubes for the ICARUS T600 detector
Authors:
M. Babicz,
L. Bagby,
B. Baibussinov,
V. Bellini,
M. Bonesini,
A. Braggiotti,
S. Centro,
T. Cervi,
A. G. Cocco,
A. Falcone,
C. Farnese,
A. Fava,
F. Fichera,
D. Gibin,
A. Guglielmi,
U. Kose,
R. Mazza,
A. Menegolli,
G. Meng,
C. Montanari,
M. Nessi,
P. Picchi,
F. Pietropaolo,
M. C. Prata,
A. Rappoldi
, et al. (13 additional authors not shown)
Abstract:
ICARUS T600 will be operated as far detector of the Short Baseline Neutrino program at Fermilab (USA), which foresees three liquid argon time projection chambers along the Booster Neutrino Beam line to search for a LSND-like sterile neutrino signal. The detector employs 360 photomultiplier tubes, Hamamatsu model R5912-MOD, suitable for cryogenic applications. A total of 400 PMTs were procured from…
▽ More
ICARUS T600 will be operated as far detector of the Short Baseline Neutrino program at Fermilab (USA), which foresees three liquid argon time projection chambers along the Booster Neutrino Beam line to search for a LSND-like sterile neutrino signal. The detector employs 360 photomultiplier tubes, Hamamatsu model R5912-MOD, suitable for cryogenic applications. A total of 400 PMTs were procured from Hamamatsu and tested at room temperature to evaluate the performance of the devices and their compliance to detect the liquid argon scintillation light in the T600 detector. Furthermore 60 units were also characterized at cryogenic temperature, in liquid argon bath, to evaluate any parameter variation which could affect the scintillation light detection. All the tested PMTs were found to comply with the requirements of ICARUS T600 and a subset of 360 specimens was selected for the final installation in the detector.
△ Less
Submitted 4 November, 2018; v1 submitted 23 July, 2018;
originally announced July 2018.
-
New read-out electronics for ICARUS-T600 liquid Argon TPC. Description, simulation and tests of the new front-end and ADC system
Authors:
L. Bagby,
B. Baibussinov,
V. Bellini,
M. Bonesini,
A. Braggiotti,
L. Castellani,
S. Centro,
T. Cervi,
A. G. Cocco,
F. Fabris,
A. Falcone,
C. Farnese,
A. Fava,
F. Fichera,
D. Franciotti,
G. Galet,
D. Gibin,
A. Guglielmi,
R. Guida,
W. Ketchum,
S. Marchini,
A. Menegolli,
G. Meng,
G. Menon,
C. Montanari
, et al. (20 additional authors not shown)
Abstract:
The ICARUS T600, a liquid argon time projection chamber (LAr-TPC) detector mainly devoted to neutrino physics, underwent a major overhauling at CERN in 2016-2017, which included also a new design of the read-out electronics, in view of its operation in Fermilab on the Short Baseline Neutrino (SBN) beam from 2019. The new more compact electronics showed capability of handling more efficiently the s…
▽ More
The ICARUS T600, a liquid argon time projection chamber (LAr-TPC) detector mainly devoted to neutrino physics, underwent a major overhauling at CERN in 2016-2017, which included also a new design of the read-out electronics, in view of its operation in Fermilab on the Short Baseline Neutrino (SBN) beam from 2019. The new more compact electronics showed capability of handling more efficiently the signals also in the intermediate Induction 2 wire plane with a significant increase of signal to noise (S/N), allowing for charge measurement also in this view. The new front-end and the analog to digital conversion (ADC) system are presented together with the results of the tests on 50 liters liquid argon TPC performed at CERN with cosmic rays.
△ Less
Submitted 10 May, 2018;
originally announced May 2018.