On-ground calibration of the X-ray, gamma-ray, and relativistic electron detector onboard TARANIS
Authors:
Yuuki Wada,
Philippe Laurent,
Damien Pailot,
Ion Cojocari,
Eric Bréelle,
Stéphane Colonges,
Jean-Pierre Baronick,
François Lebrun,
Pierre-Louis Blelly,
David Sarria,
Kazuhiro Nakazawa,
Miles Lindsey Clark
Abstract:
We developed the X-ray, Gamma-ray and Relativistic Electron detector (XGRE) onboard the TARANIS satellite, to investigate high-energy phenomena associated with lightning discharges such as terrestrial gamma-ray flashes and terrestrial electron beams. XGRE consisted of three sensors. Each sensor has one layer of LaBr$_{3}$ crystals for X-ray/gamma-ray detections, and two layers of plastic scintilla…
▽ More
We developed the X-ray, Gamma-ray and Relativistic Electron detector (XGRE) onboard the TARANIS satellite, to investigate high-energy phenomena associated with lightning discharges such as terrestrial gamma-ray flashes and terrestrial electron beams. XGRE consisted of three sensors. Each sensor has one layer of LaBr$_{3}$ crystals for X-ray/gamma-ray detections, and two layers of plastic scintillators for electron and charged-particle discrimination. Since 2018, the flight model of XGRE was developed, and validation and calibration tests, such as a thermal cycle test and a calibration test with the sensors onboard the satellite were performed before the launch of TARANIS on 17 November 2020. The energy range of the LaBr$_{3}$ crystals sensitive to X-rays and gamma rays was determined to be 0.04-11.6 MeV, 0.08-11.0 MeV, and 0.08-11.3 MeV for XGRE1, 2, and 3, respectively. The energy resolution at 0.662 MeV (full width at half maximum) was to be 20.5%, 25.9%, and 28.6%, respectively. Results from the calibration test were then used to validate a simulation model of XGRE and TARANIS. By performing Monte Carlo simulations with the verified model, we calculated effective areas of XGRE to X-rays, gamma rays, electrons, and detector responses to incident photons and electrons coming from various elevation and azimuth angles.
△ Less
Submitted 8 May, 2024;
originally announced May 2024.
-
Thermal architecture for the QUBIC cryogenic receiver
Authors:
A. J. May,
C. Chapron,
G. Coppi,
G. D'Alessandro,
P. de Bernardis,
S. Masi,
S. Melhuish,
M. Piat,
L. Piccirillo,
A. Schillaci,
J. -P. Thermeau,
P. Ade,
G. Amico,
D. Auguste,
J. Aumont,
S. Banfi,
G. Barbara,
P. Battaglia,
E. Battistelli,
A. Bau,
B. Belier,
D. Bennett,
L. Berge,
J. -Ph. Bernard,
M. Bersanelli
, et al. (105 additional authors not shown)
Abstract:
QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex opt…
▽ More
QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex optical and detector stages to 40 K, 4 K, 1 K and 350 mK using two pulse tube coolers, a novel 4He sorption cooler and a double-stage 3He/4He sorption cooler. We discuss the thermal and mechanical design of the cryostat, modelling and thermal analysis, and laboratory cryogenic testing.
△ Less
Submitted 6 November, 2018;
originally announced November 2018.
-
Intensity and polarization of the atmospheric emission at millimetric wavelengths at Dome Concordia
Authors:
E. S. Battistelli,
G. Amico,
A. Baù,
L. Bergé,
É. Bréelle,
R. Charlassier,
S. Collin,
A. Cruciani,
P. de Bernardis,
C. Dufour,
L. Dumoulin,
M. Gervasi,
M. Giard,
C. Giordano,
Y. Giraud-Héraud,
L. Guglielmi,
J. -C. Hamilton,
J. Landé,
B. Maffei,
M. Maiello,
S. Marnieros,
S. Masi,
A. Passerini,
F. Piacentini,
M. Piat
, et al. (10 additional authors not shown)
Abstract:
Atmospheric emission is a dominant source of disturbance in ground-based astronomy at mm wavelengths. The Antarctic plateau is recognized to be an ideal site for mm and sub-mm observations, and the French/Italian base of Dome C is among the best sites on Earth for these observations. In this paper we present measurements, performed using the BRAIN-pathfinder experiment, at Dome C of the atmospheri…
▽ More
Atmospheric emission is a dominant source of disturbance in ground-based astronomy at mm wavelengths. The Antarctic plateau is recognized to be an ideal site for mm and sub-mm observations, and the French/Italian base of Dome C is among the best sites on Earth for these observations. In this paper we present measurements, performed using the BRAIN-pathfinder experiment, at Dome C of the atmospheric emission in intensity and polarization at 150GHz, one of the best observational frequencies for CMB observations when considering cosmic signal intensity, atmospheric transmission, detectors sensitivity, and foreground removal. Careful characterization of the air-mass synchronous emission has been performed, acquiring more that 380 elevation scans (i.e. "skydip") during the third BRAIN-pathfinder summer campaign in December 2009/January 2010. The extremely high transparency of the Antarctic atmosphere over Dome Concordia is proven by the very low measured optical depth: <tau_I>=0.050 \pm 0.003 \pm 0.011 where the first error is statistical and the second is systematic error. Mid term stability, over the summer campaign, of the atmosphere emission has also been studied. Adapting the radiative transfer atmosphere emission model "am" to the particular conditions found at Dome C, we also infer the level of the PWV content of the atmosphere, notoriously the main source of disturbance in millimetric astronomy (<PWV>=0.77 +/- 0.06 + 0.15 - 0.12 mm). Upper limits on the air-mass correlated polarized signal are also placed for the first time. The degree of circular polarization of atmospheric emission is found to be lower than 0.2% (95%CL), while the degree of linear polarization is found to be lower than 0.1% (95%CL). These limits include signal-correlated instrumental spurious polarization.
△ Less
Submitted 20 April, 2012; v1 submitted 26 March, 2012;
originally announced March 2012.
-
Planck Early Results. II. The thermal performance of Planck
Authors:
Planck Collaboration,
P. A. R. Ade,
N. Aghanim,
M. Arnaud,
M. Ashdown,
J. Aumont,
C. Baccigalupi,
M. Baker,
A. Balbi,
A. J. Banday,
R. B. Barreiro,
E. Battaner,
K. Benabed,
A. Benoit,
J. P. Bernard,
M. Bersanelli,
P. Bhandari,
R. Bhatia,
J. J. Bock,
A. Bonaldi,
J. R. Bond,
J. Borders,
J. Borrill,
F. R. Bouchet,
B. Bowman
, et al. (203 additional authors not shown)
Abstract:
The performance of the Planck instruments in space is enabled by their low operating temperatures, 20K for LFI and 0.1K for HFI, achieved through a combination of passive radiative cooling and three active mechanical coolers. The scientific requirement for very broad frequency coverage led to two detector technologies with widely different temperature and cooling needs. Active coolers could satisf…
▽ More
The performance of the Planck instruments in space is enabled by their low operating temperatures, 20K for LFI and 0.1K for HFI, achieved through a combination of passive radiative cooling and three active mechanical coolers. The scientific requirement for very broad frequency coverage led to two detector technologies with widely different temperature and cooling needs. Active coolers could satisfy these needs; a helium cryostat, as used by previous cryogenic space missions (IRAS, COBE, ISO, Spitzer, AKARI), could not. Radiative cooling is provided by three V-groove radiators and a large telescope baffle. The active coolers are a hydrogen sorption cooler (<20K), a 4He Joule-Thomson cooler (4.7K), and a 3He-4He dilution cooler (1.4K and 0.1K). The flight system was at ambient temperature at launch and cooled in space to operating conditions. The HFI bolometer plate reached 93mK on 3 July 2009, 50 days after launch. The solar panel always faces the Sun, shadowing the rest of Planck, andoperates at a mean temperature of 384K. At the other end of the spacecraft, the telescope baffle operates at 42.3K and the telescope primary mirror operates at 35.9K. The temperatures of key parts of the instruments are stabilized by both active and passive methods. Temperature fluctuations are driven by changes in the distance from the Sun, sorption cooler cycling and fluctuations in gas-liquid flow, and fluctuations in cosmic ray flux on the dilution and bolometer plates. These fluctuations do not compromise the science data.
△ Less
Submitted 2 January, 2012; v1 submitted 11 January, 2011;
originally announced January 2011.
-
QUBIC: The QU Bolometric Interferometer for Cosmology
Authors:
The QUBIC collaboration,
E. Battistelli,
A. Baù,
D. Bennett,
L. Bergé,
J. -Ph. Bernard,
P. de Bernardis,
A. Bounab,
É. Bréelle,
E. F. Bunn,
M. Calvo,
R. Charlassier,
S. Collin,
A. Cruciani,
G. Curran,
L. Dumoulin,
A. Gault,
M. Gervasi,
A. Ghribi,
M. Giard,
C. Giordano,
Y. Giraud-Héraud,
M. Gradziel,
L. Guglielmi,
J. -Ch. Hamilton
, et al. (35 additional authors not shown)
Abstract:
One of the major challenges of modern cosmology is the detection of B-mode polarization anisotropies in the CMB. These originate from tensor fluctuations of the metric produced during the inflationary phase. Their detection would therefore constitute a major step towards understanding the primordial Universe. The expected level of these anisotropies is however so small that it requires a new gener…
▽ More
One of the major challenges of modern cosmology is the detection of B-mode polarization anisotropies in the CMB. These originate from tensor fluctuations of the metric produced during the inflationary phase. Their detection would therefore constitute a major step towards understanding the primordial Universe. The expected level of these anisotropies is however so small that it requires a new generation of instruments with high sensitivity and extremely good control of systematic effects. We propose the QUBIC instrument based on the novel concept of bolometric interferometry, bringing together the sensitivity advantages of bolometric detectors with the systematics effects advantages of interferometry. Methods: The instrument will directly observe the sky through an array of entry horns whose signals will be combined together using an optical combiner. The whole set-up is located inside a cryostat. Polarization modulation will be achieved using a rotating half-wave plate and interference fringes will be imaged on two focal planes (separated by a polarizing grid) tiled with bolometers. We show that QUBIC can be considered as a synthetic imager, exactly similar to a usual imager but with a synthesized beam formed by the array of entry horns. Scanning the sky provides an additional modulation of the signal and improve the sky coverage shape. The usual techniques of map-making and power spectrum estimation can then be applied. We show that the sensitivity of such an instrument is comparable with that of an imager with the same number of horns. We anticipate a low level of beam-related systematics thanks to the fact that the synthesized beam is determined by the location of the primary horns. Other systematics should be under good control thanks to an autocalibration technique, specific to our concept, that will permit the accurate determination of most of the systematics parameters.
△ Less
Submitted 4 October, 2010;
originally announced October 2010.
-
A demonstrator for bolometric interferometry
Authors:
Adnan Ghribi,
Andrea Tartari,
Silvia Galli,
Michel Piat,
Eric Breelle,
Jean-Christophe Hamilton,
Sebastiano Spinelli,
Massimo Gervasi,
Mario Zannoni
Abstract:
Bolometric Interferometry (BI) is one of the most promising techniques for precise measurements of the Cosmic Microwave Background polarization. In this paper, we present the results of DIBO (Demonstrateur d'Interferometrie Bolometrique), a single-baseline demonstrator operating at 90 GHz, built to proof the validity of the BI concept applied to a millimeter-wave interferometer. This instrument…
▽ More
Bolometric Interferometry (BI) is one of the most promising techniques for precise measurements of the Cosmic Microwave Background polarization. In this paper, we present the results of DIBO (Demonstrateur d'Interferometrie Bolometrique), a single-baseline demonstrator operating at 90 GHz, built to proof the validity of the BI concept applied to a millimeter-wave interferometer. This instrument has been characterized in the laboratory with a detector at room temperature and with a 4 K bolometer. This allowed us to measure interference patterns in a clean way, both (1) rotating the source and (2) varying with time the phase shift among the two interferometer's arms. Detailed modelisation has also been performed and validated with measurements.
△ Less
Submitted 2 February, 2009;
originally announced February 2009.
-
An efficient phase-shifting scheme for bolometric additive interferometry
Authors:
R. Charlassier,
J. -Ch. Hamilton,
É. Bréelle,
A. Ghribi,
Y. Giraud-Héraud,
J. Kaplan,
M. Piat,
D. Prêle
Abstract:
Context: Most upcoming CMB polarization experiments will use direct imaging to search for the primordial gravitational waves through the B-modes. Bolometric interferometry is an appealing alternative to direct imaging that combines the advantages of interferometry in terms of systematic effects handling and those of bolometric detectors in terms of sensitivity. Aims: We calculate the signal from…
▽ More
Context: Most upcoming CMB polarization experiments will use direct imaging to search for the primordial gravitational waves through the B-modes. Bolometric interferometry is an appealing alternative to direct imaging that combines the advantages of interferometry in terms of systematic effects handling and those of bolometric detectors in terms of sensitivity. Aims: We calculate the signal from a bolometric interferometer in order to investigate its sensitivity to the Stokes parameters paying particular attention to the choice of the phase-shifting scheme applied to the input channels in order to modulate the signal. Methods: The signal is expressed as a linear combination of the Stokes parameter visibilities whose coefficients are functions of the phase-shifts. Results: We show that the signal to noise ratio on the reconstructed visibilities can be maximized provided the fact that the phase-shifting scheme is chosen in a particular way called coherent summation of equivalent baselines. As a result, a bolometric interferometer is competitive with an imager having the same number of horns, but only if the coherent summation of equivalent baselines is performed. We confirm our calculations using a Monte-Carlo simulation. We also discuss the impact of the uncertainties on the relative calibration between bolometers and propose a way to avoid this systematic effect.
△ Less
Submitted 2 June, 2008;
originally announced June 2008.