A Finely Segmented Semi-Monolithic Detector tailored for High Resolution PET
Authors:
Yannick Kuhl,
Florian Mueller,
Stephan Naunheim,
Matthias Bovelett,
Janko Lambertus,
David Schug,
Bjoern Weissler,
Eike Gegenmantel,
Pierre Gebhardt,
Volkmar Schulz
Abstract:
Preclinical research and organ-dedicated applications require high-resolution positron emission tomography (PET) detectors to visualize small structures and understand biological processes at a finer level of detail. Current commercial systems often employ finely pixelated or monolithic scintillators, each with its limitations. We present a semi-monolithic detector, tailored for high-resolution PE…
▽ More
Preclinical research and organ-dedicated applications require high-resolution positron emission tomography (PET) detectors to visualize small structures and understand biological processes at a finer level of detail. Current commercial systems often employ finely pixelated or monolithic scintillators, each with its limitations. We present a semi-monolithic detector, tailored for high-resolution PET applications, and merging concepts of monolithic and pixelated crystals. The detector features slabs measuring (24 x 10 x 1) sq. mm, coupled to a 12 x 12 readout channel photosensor with 4 mm pitch. The slabs are grouped in two arrays of 44 slabs each to achieve a higher optical photon density. We employ a fan beam collimator for fast calibration to train machine-learning-based positioning models for all three dimensions, including slab identification and depth-of-interaction (DOI), utilizing gradient tree boosting (GTB). Energy calculation was based on a position-dependent energy calibration. Using an analytical timing calibration, time skews were corrected for coincidence timing resolution (CTR) estimation. Leveraging machine-learning-based calibration in all three dimensions, we achieved high detector spatial resolution: down to 1.18 mm full width at half maximum (FWHM) detector spatial resolution and 0.75 mm mean absolute error (MAE) in the planar-monolithic direction along the slabs, and 2.14 mm FWHM and 1.03 mm MAE for depth-of-interaction (DOI) at an energy window of (435-585) keV. Correct slab interaction identification exceeded 80%, alongside an energy resolution of 13.8% and a CTR of 450 ps FWHM. Therewith, the introduced finely segmented, high-resolution slab detector demonstrates an appealing performance suitable for high-resolution PET applications. The current benchtop-based detector calibration routine allows these detectors to be used in PET systems.
△ Less
Submitted 25 October, 2023;
originally announced October 2023.