-
Signature of a possible $α$-cluster state in $N=Z$ doubly-magic $^{56}$Ni
Authors:
S. Bagchi,
H. Akimune,
J. Gibelin,
M. N. Harakeh,
N. Kalantar-Nayestanaki,
N. L. Achouri,
B. Bastin,
K. Boretzky,
H. Bouzomita,
M. Caamaño,
L. Càceres,
S. Damoy,
F. Delaunay,
B. Fernández-Domínguez,
M. Fujiwara,
U. Garg,
G. F. Grinyer,
O. Kamalou,
E. Khan,
A. Krasznahorkay,
G. Lhoutellier,
J. F. Libin,
S. Lukyanov,
K. Mazurek,
M. A. Najafi
, et al. (14 additional authors not shown)
Abstract:
An inelastic $α$-scattering experiment on the unstable $N=Z$, doubly-magic $^{56}$Ni nucleus was performed in inverse kinematics at an incident energy of 50 A.MeV at GANIL. High multiplicity for $α$-particle emission was observed within the limited phase-space of the experimental setup. This observation cannot be explained by means of the statistical-decay model. The ideal classical gas model at…
▽ More
An inelastic $α$-scattering experiment on the unstable $N=Z$, doubly-magic $^{56}$Ni nucleus was performed in inverse kinematics at an incident energy of 50 A.MeV at GANIL. High multiplicity for $α$-particle emission was observed within the limited phase-space of the experimental setup. This observation cannot be explained by means of the statistical-decay model. The ideal classical gas model at $kT$ = 0.4 MeV reproduces fairly well the experimental momentum distribution and the observed multiplicity of $α$ particles corresponds to an excitation energy around 96 MeV. The method of distributed $mα$-decay ensembles is in agreement with the experimental results if we assume that the $α$-gas state in $^{56}$Ni exists at around $113^{+15}_{-17}$ MeV. These results suggest that there may exist an exotic state consisting of many $α$ particles at the excitation energy of $113^{+15}_{-17}$ MeV.
△ Less
Submitted 29 October, 2020;
originally announced October 2020.
-
High Precision Measurement of the $^{19}$Ne Half-life using real-time digital acquisition
Authors:
C. Fontbonne,
P. Ujić,
F. de Oliveira Santos,
X. Fléchard,
F. Rotaru,
N. L. Achouri,
V. Girard Alcindor,
B. Bastin,
F. Boulay,
J. B. Briand,
A. M. Sánchez-Benítez,
H. Bouzomita,
C. Borcea,
R. Borcea,
B. Blank,
B. Carniol,
I. Čeliković,
P. Delahaye,
F. Delaunay,
D. Etasse,
G. Fremont,
G. de France,
J. M. Fontbonne,
G. F. Grinyer,
J. Harang
, et al. (12 additional authors not shown)
Abstract:
The half-life of $^{19}$Ne has been measured using a real-time digital multiparametric acquisition system providing an accurate time-stamp and relevant information on the detectors signals for each decay event. An exhaustive offline analysis of the data gave unique access to experimental effects potentially biasing the measurement. After establishing the influence factors impacting the measurement…
▽ More
The half-life of $^{19}$Ne has been measured using a real-time digital multiparametric acquisition system providing an accurate time-stamp and relevant information on the detectors signals for each decay event. An exhaustive offline analysis of the data gave unique access to experimental effects potentially biasing the measurement. After establishing the influence factors impacting the measurement such as after-pulses, pile-up, gain and base line fluctuations, their effects were accurately estimated and the event selection optimized. The resulting half-life, $17.2569\pm0.0019_{(stat)}\pm0.0009_{(syst)}$~s, is the most precise up to now for $^{19}$Ne. It is found in agreement with two recent precise measurements and not consistent with the most recent one [L.J. Broussard {\it et al.}, Phys. Rev. Lett. {\bf112}, 212301 (2014)] by 3.0 standard deviations. The full potential of the technique for nuclei with half-lives of a few seconds is discussed.
△ Less
Submitted 27 September, 2017;
originally announced September 2017.
-
High-precision efficiency calibration of a high-purity co-axial germanium detector
Authors:
B. Blank,
J. Souin,
P. Ascher,
L. Audirac,
G. Canchel,
M. Gerbaux,
S. Grevy,
J. Giovinazzo,
H. Guerin,
T. Kurtukian Nieto,
I. Matea,
H. Bouzomita,
P. Delahaye,
G. F. Grinyer,
J. C. Thomas
Abstract:
A high-purity co-axial germanium detector has been calibrated in efficiency to a precision of about 0.15% over a wide energy range. High-precision scans of the detector crystal and gamma-ray source measurements have been compared to Monte-Carlo simulations to adjust the dimensions of a detector model. For this purpose, standard calibration sources and short-lived on-line sources have been used. Th…
▽ More
A high-purity co-axial germanium detector has been calibrated in efficiency to a precision of about 0.15% over a wide energy range. High-precision scans of the detector crystal and gamma-ray source measurements have been compared to Monte-Carlo simulations to adjust the dimensions of a detector model. For this purpose, standard calibration sources and short-lived on-line sources have been used. The resulting efficiency calibration reaches the precision needed e.g. for branching ratio measurements of super-allowed beta decays for tests of the weak-interaction standard model.
△ Less
Submitted 4 April, 2014;
originally announced April 2014.