-
A high sensitivity Cherenkov detector for Prompt Gamma Timing and Time Imaging
Authors:
Maxime Jacquet,
Saba Ansari,
Marie-Laure Gallin-Martel,
Adélie André,
Yannick Boursier,
Mathieu Dupont,
Jilali Es-smimih,
Laurent Gallin-Martel,
Joël Hérault,
Christophe Hoarau,
Johan-Petter Hofverberg,
Daniel Maneval,
Christian Morel,
Jean-François Muraz,
Fabrice Salicis,
Sara Marcatili
Abstract:
We recently proposed a new approach for the real-time monitoring of particle therapy treatments with the goal of achieving high sensitivities on the particle range measurement already at limited counting statistics. This method extends the Prompt Gamma (PG) timing technique to obtain the PG vertex distribution from the exclusive measurement of particle Time-Of-Flight (TOF). It was previously shown…
▽ More
We recently proposed a new approach for the real-time monitoring of particle therapy treatments with the goal of achieving high sensitivities on the particle range measurement already at limited counting statistics. This method extends the Prompt Gamma (PG) timing technique to obtain the PG vertex distribution from the exclusive measurement of particle Time-Of-Flight (TOF). It was previously shown, through Monte Carlo simulation, that an original data reconstruction algorithm (Prompt Gamma Time Imaging) allows to combine the response of multiple detectors placed around the target. In this work we focus on the experimental feasibility of PGTI in Single Proton Regime (SPR) through the development of a multi-channel, Cherenkov-based PG detector with a targeted time resolution of 235 ps (FWHM): the TOF Imaging ARrAy (TIARA). The PG module that we developed is composed of a small PbF$_{2}$ crystal coupled to a silicon photoMultiplier to provide the time stamp of the PG. This prototype was tested with 63 MeV protons delivered from a cyclotron: a time resolution of 276 ps (FWHM) was obtained, resulting in a proton range sensitivity of 4 mm at 2$σ$ with the acquisition of only 600 PGs. A second prototype was also evaluated with 148 MeV protons delivered from a synchro-cyclotron obtaining a time resolution below 167 ps (FWHM) for the gamma detector. Moreover, using two identical PG modules, it was shown that a uniform sensitivity on the PG profiles would be achievable by combining the response of gamma detectors uniformly distributed around the target. This work provides the experimental proof-of-concept for the development of a high sensitivity detector that can be used to monitor particle therapy treatments and potentially act in real-time if the irradiation does not comply to treatment plan.
△ Less
Submitted 7 September, 2023;
originally announced September 2023.
-
A Time-Of-Flight-Based Reconstruction for Real-Time Prompt-Gamma Imaging in Protontherapy
Authors:
Maxime Jacquet,
Sara Marcatili,
Marie-Laure Gallin-Martel,
Jean-Luc Bouly,
Yannick Boursier,
Denis Dauvergne,
Mathieu Dupont,
Laurent Gallin-Martel,
Joël Hérault,
Jean-Michel Létang,
Daniel Manéval,
Christian Morel,
Jean-François Muraz,
Étienne Testa
Abstract:
We are currently conceiving, through (MC) simulation, a multi-channel gamma detector array (TIARA for Time-of-flight Imaging ARrAy) for the online monitoring of protontherapy treatments. By measuring the Time-Of-Flight (TOF) between a beam monitor placed upstream and the Prompt-Gamma (PG) detector, our goal is to reconstruct the PG vertex distribution to detect a possible deviation of proton beam…
▽ More
We are currently conceiving, through (MC) simulation, a multi-channel gamma detector array (TIARA for Time-of-flight Imaging ARrAy) for the online monitoring of protontherapy treatments. By measuring the Time-Of-Flight (TOF) between a beam monitor placed upstream and the Prompt-Gamma (PG) detector, our goal is to reconstruct the PG vertex distribution to detect a possible deviation of proton beam delivery. In this paper, two non-iterative reconstruction strategies are proposed. The first is based on the resolution of an analytical formula describing the PG vertex distribution in 3D. Here, it was resolved under a one-dimensional approximation in order to measure a potential proton range shift along the beam direction. The second is based on the calculation of the Centre-Of-Gravity (COG) of the TIARA pixel detectors counts and also provides 3D information on a possible beam displacement. The PG vertex reconstruction was evaluated in two different scenarios. A coincidence time resolution of 100 ps (rms) can be attained in single proton regime (operating a reduction of the beam current) and using an external beam monitor to provide a start trigger for the TOF measurement. Under these conditions, MC simulations have shown that a millimetric proton range shift sensitivity can be achieved at 2$σ$ with 10$^{8}$ incident protons. This level of accuracy would allow to act in real-time if the treatment does not conform to treatment plan. A worst case scenario of a 1 ns (rms) TOF resolution was also considered to demonstrate that a degraded timing information can be compensated by increasing the acquisition statistics: in this case, a 2 mm range shift would be detectable at 2$σ$ with 10$^{9}$ incident protons. The COG method has shown excellent capabilities of detecting lateral beam displacements: a 2 mm sensitivity was found at 2$σ$ with 10$^{8}$ incident protons.
△ Less
Submitted 16 December, 2020;
originally announced December 2020.
-
Proceedings of the fourth "international Traveling Workshop on Interactions between low-complexity data models and Sensing Techniques" (iTWIST'18)
Authors:
Sandrine Anthoine,
Yannick Boursier,
Laurent Jacques
Abstract:
The iTWIST workshop series aim at fostering collaboration between international scientific teams for develo** new theories, applications and generalizations of low-complexity models. These events emphasize dissemination of ideas through both specific oral and poster presentations, as well as free discussions. For this fourth edition, iTWIST'18 gathered in CIRM, Marseille, France, 74 internationa…
▽ More
The iTWIST workshop series aim at fostering collaboration between international scientific teams for develo** new theories, applications and generalizations of low-complexity models. These events emphasize dissemination of ideas through both specific oral and poster presentations, as well as free discussions. For this fourth edition, iTWIST'18 gathered in CIRM, Marseille, France, 74 international participants and featured 7 invited talks, 16 oral presentations, and 21 posters.
From iTWIST'18, the scientific committee has decided that the workshop proceedings will adopt the episcience.org philosophy, combined with arXiv.org: in a nutshell, "the proceedings are equivalent to an overlay page, built above arXiv.org; they add value to these archives by attaching a scientific caution to the validated papers."
This means that all papers listed in the HTML page of this arxiv publication (see the menu on the right) have been thoroughly evaluated and approved by two independent reviewers, and authors have revised their work according to the comments provided by these reviewers.
△ Less
Submitted 20 December, 2018; v1 submitted 3 December, 2018;
originally announced December 2018.
-
Proceedings of the second "international Traveling Workshop on Interactions between Sparse models and Technology" (iTWIST'14)
Authors:
L. Jacques,
C. De Vleeschouwer,
Y. Boursier,
P. Sudhakar,
C. De Mol,
A. Pizurica,
S. Anthoine,
P. Vandergheynst,
P. Frossard,
C. Bilen,
S. Kitic,
N. Bertin,
R. Gribonval,
N. Boumal,
B. Mishra,
P. -A. Absil,
R. Sepulchre,
S. Bundervoet,
C. Schretter,
A. Dooms,
P. Schelkens,
O. Chabiron,
F. Malgouyres,
J. -Y. Tourneret,
N. Dobigeon
, et al. (42 additional authors not shown)
Abstract:
The implicit objective of the biennial "international - Traveling Workshop on Interactions between Sparse models and Technology" (iTWIST) is to foster collaboration between international scientific teams by disseminating ideas through both specific oral/poster presentations and free discussions. For its second edition, the iTWIST workshop took place in the medieval and picturesque town of Namur in…
▽ More
The implicit objective of the biennial "international - Traveling Workshop on Interactions between Sparse models and Technology" (iTWIST) is to foster collaboration between international scientific teams by disseminating ideas through both specific oral/poster presentations and free discussions. For its second edition, the iTWIST workshop took place in the medieval and picturesque town of Namur in Belgium, from Wednesday August 27th till Friday August 29th, 2014. The workshop was conveniently located in "The Arsenal" building within walking distance of both hotels and town center. iTWIST'14 has gathered about 70 international participants and has featured 9 invited talks, 10 oral presentations, and 14 posters on the following themes, all related to the theory, application and generalization of the "sparsity paradigm": Sparsity-driven data sensing and processing; Union of low dimensional subspaces; Beyond linear and convex inverse problem; Matrix/manifold/graph sensing/processing; Blind inverse problems and dictionary learning; Sparsity and computational neuroscience; Information theory, geometry and randomness; Complexity/accuracy tradeoffs in numerical methods; Sparsity? What's next?; Sparse machine learning and inference.
△ Less
Submitted 9 October, 2014; v1 submitted 2 October, 2014;
originally announced October 2014.
-
Spread spectrum for imaging techniques in radio interferometry
Authors:
Y. Wiaux,
G. Puy,
Y. Boursier,
P. Vandergheynst
Abstract:
We consider the probe of astrophysical signals through radio interferometers with small field of view and baselines with non-negligible and constant component in the pointing direction. In this context, the visibilities measured essentially identify with a noisy and incomplete Fourier coverage of the product of the planar signals with a linear chirp modulation. In light of the recent theory of c…
▽ More
We consider the probe of astrophysical signals through radio interferometers with small field of view and baselines with non-negligible and constant component in the pointing direction. In this context, the visibilities measured essentially identify with a noisy and incomplete Fourier coverage of the product of the planar signals with a linear chirp modulation. In light of the recent theory of compressed sensing and in the perspective of defining the best possible imaging techniques for sparse signals, we analyze the related spread spectrum phenomenon and suggest its universality relative to the sparsity dictionary. Our results rely both on theoretical considerations related to the mutual coherence between the sparsity and sensing dictionaries, as well as on numerical simulations.
△ Less
Submitted 11 August, 2009; v1 submitted 6 July, 2009;
originally announced July 2009.