-
Chiral sensing with achiral anisotropic metasurfaces
Authors:
Sotiris Droulias,
Lykourgos Bougas
Abstract:
Recently, we proposed a metasurface design for chiral sensing that (i) results in enhanced chiroptical signals by more than two orders of magnitude for ultrathin, subwavelength, chiral samples over a uniform and accessible area, (ii) allows for complete measurements of the total chirality (magnitude and sign of both its real and imaginary part), and (iii) offers the possibility for a crucial signa…
▽ More
Recently, we proposed a metasurface design for chiral sensing that (i) results in enhanced chiroptical signals by more than two orders of magnitude for ultrathin, subwavelength, chiral samples over a uniform and accessible area, (ii) allows for complete measurements of the total chirality (magnitude and sign of both its real and imaginary part), and (iii) offers the possibility for a crucial signal reversal (excitation with reversed polarization) that enables chirality measurements in an absolute manner, i.e., without the need for sample removal. Our design is based on the anisotropic response of the metasurface, rather than the superchirality of the generated near-fields, as in most contemporary nanophotonic-based chiral sensing approaches. Here, we derive analytically, and verify numerically, simple formulas that provide insight to the sensing mechanism and explain how anisotropic metasurfaces, in general, offer additional degrees of freedom with respect to their isotropic counterparts. We provide a detailed discussion of the key functionalities and benefits of our proposed design and we demonstrate practical measurement schemes for the unambiguous determination of an unknown chirality. Last, we provide the design principles towards broadband operation - from near-infrared to near-ultraviolet frequencies - opening the way for highly sensitive nanoscale chiroptical spectroscopy.
△ Less
Submitted 18 March, 2021;
originally announced March 2021.
-
Rapid parameter estimation of discrete decaying signals using autoencoder networks
Authors:
Jim C. Visschers,
Dmitry Budker,
Lykourgos Bougas
Abstract:
In this work we demonstrate the use of neural networks for rapid extraction of signal parameters of discretely sampled signals. In particular, we use dense autoencoder networks to extract the parameters of interest from exponentially decaying signals and decaying oscillations. By using a three-stage training method and careful choice of the neural network size, we are able to retrieve the relevant…
▽ More
In this work we demonstrate the use of neural networks for rapid extraction of signal parameters of discretely sampled signals. In particular, we use dense autoencoder networks to extract the parameters of interest from exponentially decaying signals and decaying oscillations. By using a three-stage training method and careful choice of the neural network size, we are able to retrieve the relevant signal parameters directly from the latent space of the autoencoder network at significantly improved rates compared to traditional algorithmic signal-analysis approaches. We show that the achievable precision and accuracy of this method of analysis is similar to conventional algorithm-based signal analysis methods, by demonstrating that the extracted signal parameters are approaching their fundamental parameter estimation limit as provided by the Cramér-Rao bound. Furthermore, we demonstrate that autoencoder networks are able to achieve signal analysis, and, hence, parameter extraction, at rates of 75 kHz, orders-of-magnitude faster than conventional techniques with similar precision. Finally, we explore the limitations of our approach, demonstrating that analysis rates of $>$200 kHz are feasible with further optimization of the transfer rate between the data-acquisition system and data-analysis system.
△ Less
Submitted 29 June, 2021; v1 submitted 10 March, 2021;
originally announced March 2021.
-
Rapid parameter determination of discrete damped sinusoidal oscillations
Authors:
Jim C. Visschers,
Emma Wilson,
Thomas Conneely,
Andrey Mudrov,
Lykourgos Bougas
Abstract:
We present different computational approaches for the rapid extraction of the signal parameters of discretely sampled damped sinusoidal signals. We compare time- and frequency-domain-based computational approaches in terms of their accuracy and precision and computational time required in estimating the frequencies of such signals, and observe a general trade-off between precision and speed. Our m…
▽ More
We present different computational approaches for the rapid extraction of the signal parameters of discretely sampled damped sinusoidal signals. We compare time- and frequency-domain-based computational approaches in terms of their accuracy and precision and computational time required in estimating the frequencies of such signals, and observe a general trade-off between precision and speed. Our motivation is precise and rapid analysis of damped sinusoidal signals as these become relevant in view of the recent experimental developments in cavity-enhanced polarimetry and ellipsometry, where the relevant time scales and frequencies are typically within the $\sim1-10\,μ$s and $\sim1-100$MHz ranges, respectively. In such experimental efforts, single-shot analysis with high accuracy and precision becomes important when develo** experiments that study dynamical effects and/or when develo** portable instrumentations. Our results suggest that online, running-fashion, microsecond-resolved analysis of polarimetric/ellipsometric measurements with fractional uncertainties at the $10^{-6}$ levels, is possible, and using a proof-of-principle experimental demonstration we show that using a frequency-based analysis approach we can monitor and analyze signals at kHz rates and accurately detect signal changes at microsecond time-scales.
△ Less
Submitted 9 October, 2020;
originally announced October 2020.
-
Probing topological spin structures using light-polarization and magnetic microscopy
Authors:
Till Lenz,
Georgios Chatzidrosos,
Zhiyuan Wang,
Lykourgos Bougas,
Yannick Dumeige,
Arne Wickenbrock,
Nico Kerber,
Jakub Zázvorka,
Fabian Kammerbauer,
Mathias Kläui,
Zeeshawn Kazi,
Kai-Mei C. Fu,
Kohei Itoh,
Hideyuki Watanabe,
Dmitry Budker
Abstract:
We present an imaging modality that enables detection of magnetic moments and their resulting stray magnetic fields. We use wide-field magnetic imaging that employs a diamond-based magnetometer and has combined magneto-optic detection (e.g. magneto-optic Kerr effect) capabilities. We employ such an instrument to image magnetic (stripe) domains in multilayered ferromagnetic structures.
We present an imaging modality that enables detection of magnetic moments and their resulting stray magnetic fields. We use wide-field magnetic imaging that employs a diamond-based magnetometer and has combined magneto-optic detection (e.g. magneto-optic Kerr effect) capabilities. We employ such an instrument to image magnetic (stripe) domains in multilayered ferromagnetic structures.
△ Less
Submitted 7 October, 2020;
originally announced October 2020.
-
Rapid online solid-state battery diagnostics with optically pumped magnetometers
Authors:
Yinan Hu,
Geoffrey Z. Iwata,
Lykourgos Bougas,
John W. Blanchard,
Arne Wickenbrock,
Gerhard Jakob,
Stephan Schwarz,
Clemens Schwarzinger,
Alexej Jerschow,
Dmitry Budker
Abstract:
Solid state battery technology is motivated by the desire to deliver flexible power storage in a safe and efficient manner. The increasingly widespread use of batteries from mass-production facilities highlights the need for a rapid and sensitive diagnostic for identifying battery defects. We demonstrate the use of atomic magnetometry to measure the magnetic fields around miniature solid-state bat…
▽ More
Solid state battery technology is motivated by the desire to deliver flexible power storage in a safe and efficient manner. The increasingly widespread use of batteries from mass-production facilities highlights the need for a rapid and sensitive diagnostic for identifying battery defects. We demonstrate the use of atomic magnetometry to measure the magnetic fields around miniature solid-state battery cells. These fields encode information about battery manufacturing defects, state of charge, impurities, or can provide important insights into ageing processes. Compared with SQUID-based magnetometry, the availability of atomic magnetometers, however, highlights the possibility for a low-cost, portable, and flexible implementation of battery quality-control and characterization technology.
△ Less
Submitted 5 October, 2020;
originally announced October 2020.
-
Action potentials induce biomagnetic fields in Venus flytrap plants
Authors:
Anne Fabricant,
Geoffrey Z. Iwata,
Sönke Scherzer,
Lykourgos Bougas,
Katharina Rolfs,
Anna Jodko-Władzińska,
Jens Voigt,
Rainer Hedrich,
Dmitry Budker
Abstract:
Upon stimulation, plants elicit electrical signals that can travel within a cellular network analogous to the animal nervous system. It is well-known that in the human brain, voltage changes in certain regions result from concerted electrical activity which, in the form of action potentials (APs), travels within nerve-cell arrays. Electrophysiological techniques like electroencephalography, magnet…
▽ More
Upon stimulation, plants elicit electrical signals that can travel within a cellular network analogous to the animal nervous system. It is well-known that in the human brain, voltage changes in certain regions result from concerted electrical activity which, in the form of action potentials (APs), travels within nerve-cell arrays. Electrophysiological techniques like electroencephalography, magnetoencephalography, and magnetic resonance imaging are used to record this activity and to diagnose disorders. In the plant kingdom, two types of electrical signals are observed: all-or-nothing APs of similar amplitudes to those seen in humans and animals, and slow-wave potentials of smaller amplitudes. Sharp APs appear restricted to unique plant species like the "sensitive plant", Mimosa pudica, and the carnivorous Venus flytrap, Dionaea muscipula. Here we ask the question, is electrical activity in the Venus flytrap accompanied by distinct magnetic signals? Using atomic optically pumped magnetometers, biomagnetism in AP-firing traps of the carnivorous plant was recorded. APs were induced by heat stimulation, and the thermal properties of ion channels underlying the AP were studied. The measured magnetic signals exhibit similar temporal behavior and shape to the fast de- and repolarization AP phases. Our findings pave the way to understanding the molecular basis of biomagnetism, which might be used to improve magnetometer-based noninvasive diagnostics of plant stress and disease.
△ Less
Submitted 18 August, 2020; v1 submitted 12 August, 2020;
originally announced August 2020.
-
Photoluminescence at the ground state level anticrossing of the nitrogen-vacancy center in diamond
Authors:
Viktor Ivády,
Huijie Zheng,
Arne Wickenbrock,
Lykourgos Bougas,
Georgios Chatzidrosos,
Kazuo Nakamura,
Hitoshi Sumiya,
Takeshi Ohshima,
Junichi Isoya,
Dmitry Budker,
Igor A. Abrikosov,
Adam Gali
Abstract:
The nitrogen-vacancy center (NV center) in diamond at magnetic fields corresponding to the ground state level anticrossing (GSLAC) region gives rise to rich photoluminescence (PL) signals due to the vanishing energy gap between the electron spin states, which enables to have an effect on the NV center's luminescence for a broad variety of environmental couplings. In this article we report on the G…
▽ More
The nitrogen-vacancy center (NV center) in diamond at magnetic fields corresponding to the ground state level anticrossing (GSLAC) region gives rise to rich photoluminescence (PL) signals due to the vanishing energy gap between the electron spin states, which enables to have an effect on the NV center's luminescence for a broad variety of environmental couplings. In this article we report on the GSLAC photoluminescence signature of NV ensembles in different spin environments at various external fields. We investigate the effects of transverse electric and magnetic fields, P1 centers, NV centers, and the $^{13}$C nuclear spins, each of which gives rise to a unique PL signature at the GSLAC. The comprehensive analysis of the couplings and related optical signal at the GSLAC provides a solid ground for advancing various microwave-free applications at the GSLAC, including but not limited to magnetometry, spectroscopy, dynamic nuclear polarization (DNP), and nuclear magnetic resonance (NMR) detection. We demonstrate that not only the most abundant $^{14}$NV center but the $^{15}$NV can also be utilized in such applications and that nuclear spins coupled to P1 centers can be polarized directly by the NV center at the GSLAC, through a giant effective nuclear $g$-factor arising from the NV center-P1 center-nuclear spin coupling. We report on new alternative for measuring defect concentration in the vicinity of NV centers and on the optical signatures of interacting, mutually aligned NV centers.
△ Less
Submitted 19 June, 2020; v1 submitted 9 June, 2020;
originally announced June 2020.
-
Continuous-Wave Cavity Ring-Down Polarimetry
Authors:
Jim C. Visschers,
Oleg Tretiak,
Dmitry Budker,
Lykourgos Bougas
Abstract:
We present a new cavity-based polarimetric scheme for highly sensitive and time-resolved measurements of birefringence and dichroism, linear and circular, that employs rapidly-pulsed single-frequency CW laser sources and extends current cavity-based spectropolarimetric techniques. We demonstrate how the use of a CW laser source allows for gains in spectral resolution, signal intensity and data acq…
▽ More
We present a new cavity-based polarimetric scheme for highly sensitive and time-resolved measurements of birefringence and dichroism, linear and circular, that employs rapidly-pulsed single-frequency CW laser sources and extends current cavity-based spectropolarimetric techniques. We demonstrate how the use of a CW laser source allows for gains in spectral resolution, signal intensity and data acquisition rate compared to traditional pulsed-based cavity ring-down polarimetry (CRDP). We discuss a particular CW-CRDP modality that is different from intensity-based cavity-enhanced polarimetric schemes as it relies on the determination of the polarization-rotation frequency during a ring-down event generated by large intracavity polarization anisotropies. We present the principles of CW-CRDP and validate the applicability of this technique for measurement of the non-resonant Faraday effect in solid SiO$_2$ and CeF$_3$ and gaseous butane. We give a general analysis of the fundamental sensitivity limits for CRDP techniques and show how the presented frequency-based methodology alleviates the requirement for high finesse cavities to achieve high polarimetric sensitivities, and, thus, allows for the extension of cavity-based polarimetric schemes into different spectral regimes but most importantly renders the CW-CRDP methodology particularly suitable for robust portable polarimetric instrumentations.
△ Less
Submitted 27 March, 2020; v1 submitted 11 February, 2020;
originally announced February 2020.
-
Absolute chiral sensing in dielectric metasurfaces with signal reversals
Authors:
Sotiris Droulias,
Lykourgos Bougas
Abstract:
Sensing molecular chirality at the nanoscale has been a long-standing challenge due to the inherently weak nature of chiroptical signals, and nanophotonic approaches have proven fruitful in accessing these signals. However, in most cases, absolute chiral sensing of the total chiral refractive index has not been possible, while the strong inherent signals from the nanostructures themselves obscure…
▽ More
Sensing molecular chirality at the nanoscale has been a long-standing challenge due to the inherently weak nature of chiroptical signals, and nanophotonic approaches have proven fruitful in accessing these signals. However, in most cases, absolute chiral sensing of the total chiral refractive index has not been possible, while the strong inherent signals from the nanostructures themselves obscure the weak chiroptical signals. Here, we propose a dielectric metamaterial system that overcomes these limitations and allows for absolute measurements of the total chirality, and the possibility for a crucial signal reversal that enables chirality measurements without the need for sample removal. As proof of principle, we demonstrate signal-enhancements by a factor of 200 for ultrathin, sub-wavelength, chiral samples over a uniform and accessible area.
△ Less
Submitted 18 January, 2020;
originally announced January 2020.
-
Noncovalent force spectroscopy using wide-field optical and diamond-based magnetic imaging
Authors:
Sean Lourette,
Lykourgos Bougas,
Metin Kayci,
Shoujun Xu,
Dmitry Budker
Abstract:
A realization of the force-induced remnant magnetization spectroscopy (FIRMS) technique of specific biomolecular binding is presented where detection is accomplished with wide-field optical and diamond-based magnetometry using an ensemble of nitrogen-vacancy (NV) color centers. The technique may be adapted for massively parallel screening of arrays of nanoscale samples.
A realization of the force-induced remnant magnetization spectroscopy (FIRMS) technique of specific biomolecular binding is presented where detection is accomplished with wide-field optical and diamond-based magnetometry using an ensemble of nitrogen-vacancy (NV) color centers. The technique may be adapted for massively parallel screening of arrays of nanoscale samples.
△ Less
Submitted 27 August, 2019;
originally announced August 2019.
-
$\mathcal{P}$,$\mathcal{T}$-odd Faraday rotation on atoms and molecules in intra-cavity absorption spectroscopy as an alternative way to search for the $\mathcal{P}$,$\mathcal{T}$-odd effects in nature
Authors:
D. V. Chubukov,
L. V. Skripnikov,
L. Bougas,
L. N. Labzowsky
Abstract:
Present limit on the electron electric dipole moment ($e$EDM) is based on the electron spin precession measurement. We propose an alternative approach - observation of the $\mathcal{P}$,$\mathcal{T}$-odd Faraday effect in an external electric field on atoms and molecules using cavity-enhanced polarimetric scheme in combination with molecular (atomic) beam crossing the cavity. Our calculations of t…
▽ More
Present limit on the electron electric dipole moment ($e$EDM) is based on the electron spin precession measurement. We propose an alternative approach - observation of the $\mathcal{P}$,$\mathcal{T}$-odd Faraday effect in an external electric field on atoms and molecules using cavity-enhanced polarimetric scheme in combination with molecular (atomic) beam crossing the cavity. Our calculations of the effective electric fields and theoretical simulation of the proposed experiment on Tl and Pb atoms, PbF, YbF, ThO, and YbOH show that the present limit on the $e$EDM can be improved by 6-7 orders of magnitude.
△ Less
Submitted 26 July, 2019;
originally announced July 2019.
-
A surface plasmon platform for angle-resolved chiral sensing
Authors:
Sotiris Droulias,
Lykourgos Bougas
Abstract:
Chiral sensitive techniques have been used to probe the fundamental symmetries of the universe, study biomolecular structures, and even develop safe drugs. As chiral signals are inherently weak and often suppressed by large backgrounds, different techniques have been proposed to overcome the limitations of traditionally used chiral polarimetry. Here, we propose an angle-resolved chiral surface pla…
▽ More
Chiral sensitive techniques have been used to probe the fundamental symmetries of the universe, study biomolecular structures, and even develop safe drugs. As chiral signals are inherently weak and often suppressed by large backgrounds, different techniques have been proposed to overcome the limitations of traditionally used chiral polarimetry. Here, we propose an angle-resolved chiral surface plasmon resonance (CHISPR) scheme that can detect the absolute chirality (handedness and magnitude) of a chiral sample and is sensitive to both the real and imaginary part of a chiral sample's refractive index. We present analytical results and numerical simulations of CHISPR measurements, predicting signals in the mdeg range for chiral samples of <100nm thickness at visible wavelengths. Moreover, we present a theoretical analysis that clarifies how our far-field measurements elucidate the underlying physics. This CHISPR protocol does not require elaborate fabrication and has the advantage of being directly implementable on existing surface plasmon resonance instrumentation.
△ Less
Submitted 28 January, 2019;
originally announced January 2019.
-
Variable single-axis magnetic-field generator using permanent magnets
Authors:
Oleg Tretiak,
Peter Blümler,
Lykourgos Bougas
Abstract:
We present a design for producing precisely adjustable and alternating single-axis magnetic fields based on nested Halbach dipole pairs consisting of permanent magnets only. Our design allows for three dimensional optical and mechanical access to a region with strong adjustable dipolar fields, is compatible with systems operating under vacuum, and does not effectively dissipate heat under normal o…
▽ More
We present a design for producing precisely adjustable and alternating single-axis magnetic fields based on nested Halbach dipole pairs consisting of permanent magnets only. Our design allows for three dimensional optical and mechanical access to a region with strong adjustable dipolar fields, is compatible with systems operating under vacuum, and does not effectively dissipate heat under normal operational conditions. We present a theoretical analysis of the properties and capabilities of our design, and construct a proof-of-concept prototype. Using our prototype, we demonstrate fields of up to several kilogauss with field homogeneities of better than 5%, which are harmonically modulated at frequencies of $\sim$1Hz with a power consumption of approximately 1W. Moreover, we discuss how our design can be modified to generate adjustable quadrupolar magnetic fields with gradients as large as 9.5T/m in a region of optical and mechanical access. Our design is scalable and can be constructed to be suitable for table-top experiments, as in the case of polarimetric and magnetometric setups that require strong alternating magnetic fields, but also for large scale applications such as generators.
△ Less
Submitted 9 November, 2018;
originally announced November 2018.
-
Infrared laser magnetometry with a NV doped diamond intracavity etalon
Authors:
Yannick Dumeige,
Jean-François Roch,
Fabien Bretenaker,
Thierry Debuisschert,
Victor Acosta,
Christoph Becher,
Georgios Chatzidrosos,
Arne Wickenbrock,
Lykourgos Bougas,
Alexander Wilzewski,
Dmitry Budker
Abstract:
We propose an hybrid laser system consisting of a semiconductor external cavity laser associated to an intra-cavity diamond etalon doped with nitrogen-vacancy color centers. We consider laser emission tuned to the infrared absorption line that is enhanced under the magnetic field dependent nitrogen-vacancy electron spin resonance and show that this architecture leads to a compact solid-state magne…
▽ More
We propose an hybrid laser system consisting of a semiconductor external cavity laser associated to an intra-cavity diamond etalon doped with nitrogen-vacancy color centers. We consider laser emission tuned to the infrared absorption line that is enhanced under the magnetic field dependent nitrogen-vacancy electron spin resonance and show that this architecture leads to a compact solid-state magnetometer that can be operated at room-temperature. The sensitivity to the magnetic field limited by the photon shot-noise of the output laser beam is estimated to be around $250~\mathrm{fT/\sqrt{Hz}}$. Unlike usual NV center infrared magnetometry, this method would not require an external frequency stabilized laser. Since the proposed system relies on the competition between the laser threshold and an intracavity absorption, such laser-based optical sensor could be easily adapted to a broad variety of physical systems.
△ Less
Submitted 18 October, 2018;
originally announced October 2018.
-
Eddy-current imaging with nitrogen-vacancy centers in diamond
Authors:
Georgios Chatzidrosos,
Arne Wickenbrock,
Lykourgos Bougas,
Huijie Zheng,
Oleg Tretiak,
Yu Yang,
Dmitry Budker
Abstract:
We demonstrate microwave-free eddy-current imaging using nitrogen-vacancy centers in diamond. By detecting the eddy-current induced magnetic field of conductive samples, we can distinguish between different materials and shapes and identify structural defects. Our technique allows for the discrimination of different materials according to their conductivity. The sensitivity of the measurements is…
▽ More
We demonstrate microwave-free eddy-current imaging using nitrogen-vacancy centers in diamond. By detecting the eddy-current induced magnetic field of conductive samples, we can distinguish between different materials and shapes and identify structural defects. Our technique allows for the discrimination of different materials according to their conductivity. The sensitivity of the measurements is calculated as 8$\times 10 ^{5}$\,S/m\,$\sqrt[]{\textrm{Hz}}$ at 3.5\,MHz, for a cylindrical sample with radius $r_0$\,=\,1\,mm and height $h$\,=\,0.1\,mm (volume $\sim$\,0.3\,mm$^3$), at a distance of 0.5\,mm. In comparison with existing technologies, the diamond-based device exhibits a superior bandwidth and spatial resolution. In particular, we demonstrate a flat frequency response from DC to 3.5 MHz and a spatial resolution of 348\,$\pm$\,2\,$μ$m.
△ Less
Submitted 5 October, 2018;
originally announced October 2018.
-
Sawtooth wave adiabatic passage slowing of dysprosium
Authors:
Niels Petersen,
Florian Mühlbauer,
Lykourgos Bougas,
Arijit Sharma,
Dmitry Budker,
Patrick Windpassinger
Abstract:
We report on sawtooth wave adiabatic passage (SWAP) slowing of bosonic and fermionic dysprosium isotopes by using a 136 kHz wide transition at 626 nm. A beam of precooled atoms is further decelerated in one dimension by the SWAP force and the amount of atoms at near zero velocity is measured. We demonstrate that the SWAP slowing can be twice as fast as in a conventional optical molasses operated o…
▽ More
We report on sawtooth wave adiabatic passage (SWAP) slowing of bosonic and fermionic dysprosium isotopes by using a 136 kHz wide transition at 626 nm. A beam of precooled atoms is further decelerated in one dimension by the SWAP force and the amount of atoms at near zero velocity is measured. We demonstrate that the SWAP slowing can be twice as fast as in a conventional optical molasses operated on the same transition. In addition, we investigate the parameter range for which the SWAP force is efficiently usable in our set-up, and relate the results to the adiabaticity condition. Furthermore, we add losses to the hyperfine ground-state population of fermionic dysprosium during deceleration and observe more robust slowing with SWAP compared to slowing with the radiation pressure force.
△ Less
Submitted 17 September, 2018;
originally announced September 2018.
-
Diamond magnetic microscopy of malarial hemozoin nanocrystals
Authors:
Ilja Fescenko,
Abdelghani Laraoui,
Janis Smits,
Nazanin Mosavian,
Pauli Kehayias,
Jong Seto,
Lykourgos Bougas,
Andrey Jarmola,
Victor M. Acosta
Abstract:
Magnetic microscopy of malarial hemozoin nanocrystals was performed using optically detected magnetic resonance imaging of near-surface diamond nitrogen-vacancy centers. Hemozoin crystals were extracted from $Plasmodium$-$falciparum$-infected human blood cells and studied alongside synthetic hemozoin crystals. The stray magnetic fields produced by individual crystals were imaged at room temperatur…
▽ More
Magnetic microscopy of malarial hemozoin nanocrystals was performed using optically detected magnetic resonance imaging of near-surface diamond nitrogen-vacancy centers. Hemozoin crystals were extracted from $Plasmodium$-$falciparum$-infected human blood cells and studied alongside synthetic hemozoin crystals. The stray magnetic fields produced by individual crystals were imaged at room temperature as a function of applied field up to 350 mT. More than 100 nanocrystals were analyzed, revealing the distribution of their magnetic properties. Most crystals ($96\%$) exhibit a linear dependence of stray field magnitude on applied field, confirming hemozoin's paramagnetic nature. A volume magnetic susceptibility $χ=3.4\times10^{-4}$ is inferred using a magnetostatic model informed by correlated scanning electron microscopy measurements of crystal dimensions. A small fraction of nanoparticles (4/82 for $Plasmodium$-produced and 1/41 for synthetic) exhibit a saturation behavior consistent with superparamagnetism. Translation of this platform to the study of living malaria-infected cells may shed new light on hemozoin formation dynamics and their interaction with antimalarial drugs.
△ Less
Submitted 19 September, 2018; v1 submitted 10 August, 2018;
originally announced August 2018.
-
Widefield imaging of superconductor vortices with electron spins in diamond
Authors:
Yechezkel Schlussel,
Till Lenz,
Dominik Rohner,
Yaniv Bar-Haim,
Lykourgos Bougas,
David Groswasser,
Michael Kieschnick,
Evgeny Rozenberg,
Lucas Thiel,
Amir Waxman,
Jan Meijer,
Patrick Maletinsky,
Dmitry Budker,
Ron Folman
Abstract:
Understanding the mechanisms behind high-$T_{c}$ Type-II superconductors (SC) is still an open task in condensed matter physics. One way to gain further insight into the microscopic mechanisms leading to superconductivity is to study the magnetic properties of the SC in detail, for example by studying the properties of vortices and their dynamics. In this work we describe a new method of wide-fiel…
▽ More
Understanding the mechanisms behind high-$T_{c}$ Type-II superconductors (SC) is still an open task in condensed matter physics. One way to gain further insight into the microscopic mechanisms leading to superconductivity is to study the magnetic properties of the SC in detail, for example by studying the properties of vortices and their dynamics. In this work we describe a new method of wide-field imaging magnetometry using nitrogen-vacancy (NV) centers in diamond to image vortices in an yttrium barium copper oxide (YBCO) thin film. We demonstrate quantitative determination of the magnetic field strength of the vortex stray field, the observation of vortex patterns for different cooling fields and direct observation of vortex pinning in our disordered YBCO film. This method opens prospects for imaging of the magnetic-stray fields of vortices at frequencies from DC to several megahertz within a wide range of temperatures which allows for the study of both high-$T_{C}$ and low-$T_{C}$ SCs. The wide temperature range allowed by NV center magnetometry also makes our approach applicable for the study of phenomena like island superconductivity at elevated temperatures (e.g. in metal nano-clusters).
△ Less
Submitted 5 March, 2018;
originally announced March 2018.
-
Nondestructive in-line sub-picomolar detection of magnetic nanoparticles in flowing complex fluids
Authors:
Lykourgos Bougas,
Lukas D. Langenegger,
Carlos A. Mora,
Martin Zeltner,
Wendelin J. Stark,
Arne Wickenbrock,
John W. Blanchard,
Dmitry Budker
Abstract:
Over the last decades, the use of magnetic nanoparticles in research and commercial applications has increased dramatically. However, direct detection of trace quantities remains a challenge in terms of equipment cost, operating conditions and data acquisition times, especially in flowing conditions within complex media. Here we present the in-line, non-destructive detection of magnetic nanopartic…
▽ More
Over the last decades, the use of magnetic nanoparticles in research and commercial applications has increased dramatically. However, direct detection of trace quantities remains a challenge in terms of equipment cost, operating conditions and data acquisition times, especially in flowing conditions within complex media. Here we present the in-line, non-destructive detection of magnetic nanoparticles using high performance atomic magnetometers at ambient conditions in flowing media. We achieve sub-picomolar sensitivities measuring $\sim$30 nm ferromagnetic iron and cobalt nanoparticles that are suitable for biomedical and industrial applications, under flowing conditions in water and whole blood. Additionally, we demonstrate real-time surveillance of the magnetic separation of nanoparticles from water and whole blood. Overall our system has the merit of inline direct measurement of trace quantities of ferromagnetic nanoparticles with so far unreached sensitivities and could be applied in the biomedical field (diagnostics and therapeutics) but also in the industrial sector.
△ Less
Submitted 17 January, 2018;
originally announced January 2018.
-
Measuring molecular parity nonconservation using nuclear magnetic resonance spectroscopy
Authors:
James Eills,
John W. Blanchard,
Lykourgos Bougas,
Mikhail G. Kozlov,
Alexander Pines,
Dmitry Budker
Abstract:
The weak interaction does not conserve parity and therefore induces energy shifts in chiral enantiomers that should in principle be detectable in molecular spectra. Unfortunately, the magnitude of the expected shifts are small and in spectra of a mixture of enantiomers, the energy shifts are not resolvable. We propose a nuclear magnetic resonance (NMR) experiment in which we titrate the chirality…
▽ More
The weak interaction does not conserve parity and therefore induces energy shifts in chiral enantiomers that should in principle be detectable in molecular spectra. Unfortunately, the magnitude of the expected shifts are small and in spectra of a mixture of enantiomers, the energy shifts are not resolvable. We propose a nuclear magnetic resonance (NMR) experiment in which we titrate the chirality (enantiomeric excess) of a solvent and measure the diasteriomeric splitting in the spectra of a chiral solute in order to search for an anomalous offset due to parity nonconservation (PNC). We present a proof-of-principle experiment in which we search for PNC in the \textsuperscript{13}C resonances of small molecules, and use the \textsuperscript{1}H resonances, which are insensitive to PNC, as an internal reference. We set a new constraint on molecular PNC in \textsuperscript{13}C chemical shifts at a level of $10^{-5}$\,ppm, and provide a discussion of important considerations in the search for molecular PNC using NMR spectroscopy.
△ Less
Submitted 21 August, 2017; v1 submitted 6 July, 2017;
originally announced July 2017.
-
Miniature cavity-enhanced diamond magnetometer
Authors:
Georgios Chatzidrosos,
Arne Wickenbrock,
Lykourgos Bougas,
Nathan Leefer,
Teng Wu,
Kasper Jensen,
Yannick Dumeige,
Dmitry Budker
Abstract:
We present a highly sensitive miniaturized cavity-enhanced room-temperature magnetic-field sensor based on nitrogen-vacancy (NV) centers in diamond. The magnetic resonance signal is detected by probing absorption on the 1042\,nm spin-singlet transition. To improve the absorptive signal the diamond is placed in an optical resonator. The device has a magnetic-field sensitivity of 28 pT/…
▽ More
We present a highly sensitive miniaturized cavity-enhanced room-temperature magnetic-field sensor based on nitrogen-vacancy (NV) centers in diamond. The magnetic resonance signal is detected by probing absorption on the 1042\,nm spin-singlet transition. To improve the absorptive signal the diamond is placed in an optical resonator. The device has a magnetic-field sensitivity of 28 pT/$\sqrt{\rm{Hz}}$, a projected photon shot-noise-limited sensitivity of 22 pT/$\sqrt{\rm{Hz}}$ and an estimated quantum projection-noise-limited sensitivity of 0.43 pT/$\sqrt{\rm{Hz}}$ with the sensing volume of $\sim$ 390 $μ$m $\times$ 4500 $μ$m$^{2}$. The presented miniaturized device is the basis for an endoscopic magnetic field sensor for biomedical applications.
△ Less
Submitted 7 June, 2017;
originally announced June 2017.
-
Towards improved measurements of parity violation in atomic ytterbium
Authors:
D. Antypas,
A. Fabricant,
L. Bougas,
K. Tsigutkin,
D. Budker
Abstract:
We report on progress towards performing precision measurements of parity violation in Yb, in which the theoretical prediction for a strong weak-interaction-induced effect in the 6s^{2} ^{1}S_{0} \rightarrow 5d6s ^{3}D_{1} optical transition at 408 nm has already been confirmed, with a measurement of the effect at the \approx 10 % level of accuracy. With a new atomic-beam apparatus offering enhanc…
▽ More
We report on progress towards performing precision measurements of parity violation in Yb, in which the theoretical prediction for a strong weak-interaction-induced effect in the 6s^{2} ^{1}S_{0} \rightarrow 5d6s ^{3}D_{1} optical transition at 408 nm has already been confirmed, with a measurement of the effect at the \approx 10 % level of accuracy. With a new atomic-beam apparatus offering enhanced sensitivity, we are aiming at precisely determining the parity violation observable in Yb, which will allow us to probe the distributions of neutrons in different isotopes, investigate physics beyond the Standard Model, as well as to study intra-nucleus weak interactions, through an observation of the anapole moment of Yb nuclei with nonzero spin. We present the experimental principle employed to probe atomic parity violation, describe our new apparatus, and discuss the attained experimental sensitivity as well as the methods for characterizing systematics in these measurements.
△ Less
Submitted 2 February, 2017; v1 submitted 28 January, 2017;
originally announced January 2017.
-
Level anti-crossing magnetometry with color centers in diamond
Authors:
Huijie Zheng,
Georgios Chatzidrosos,
Arne Wickenbrock,
Lykourgos Bougas,
Reinis Lazda,
Andris Berzins,
Florian Helmuth Gahbauer,
Marcis Auzinsh,
Ruvin Ferber,
Dmitry Budker
Abstract:
Recent developments in magnetic field sensing with negatively charged nitrogen-vacancy centers (NV) in diamond employ magnetic-field (MF) dependent features in the photoluminescence (PL) and eliminate the need for microwaves (MW). Here, we study two approaches towards improving the magnetometric sensitivity using the ground-state level anti-crossing (GSLAC) feature of the NV center at a background…
▽ More
Recent developments in magnetic field sensing with negatively charged nitrogen-vacancy centers (NV) in diamond employ magnetic-field (MF) dependent features in the photoluminescence (PL) and eliminate the need for microwaves (MW). Here, we study two approaches towards improving the magnetometric sensitivity using the ground-state level anti-crossing (GSLAC) feature of the NV center at a background MF of 102.4\,mT. Following the first approach, we investigate the feature parameters for precise alignment in a dilute diamond sample; the second approach extends the sensing protocol into absorption via detection of the GSLAC in the diamond transmission of a 1042\,nm laser beam. This leads to an increase of GSLAC contrast and results in a magnetometer with a sensitivity of 0.45\,nT/$\sqrt{\text{Hz}}$ and a photon shot-noise limited sensitivity of 12.2 pT/$\sqrt{\rm{Hz}}$.
△ Less
Submitted 24 January, 2017;
originally announced January 2017.
-
Solution nuclear magnetic resonance spectroscopy on a nanostructured diamond chip
Authors:
P. Kehayias,
A. Jarmola,
N. Mosavian,
I. Fescenko,
F. M. Benito,
A. Laraoui,
J. Smits,
L. Bougas,
D. Budker,
A. Neumann,
S. R. J. Brueck,
V. M. Acosta
Abstract:
We demonstrate nuclear magnetic resonance (NMR) spectroscopy of picoliter-volume solutions with a nanostructured diamond chip. Using optical interferometric lithography, diamond surfaces were nanostructured with dense, high-aspect-ratio nanogratings, enhancing the surface area by more than a factor of 15 over mm^2 regions of the chip. The nanograting sidewalls were doped with nitrogen-vacancy (NV)…
▽ More
We demonstrate nuclear magnetic resonance (NMR) spectroscopy of picoliter-volume solutions with a nanostructured diamond chip. Using optical interferometric lithography, diamond surfaces were nanostructured with dense, high-aspect-ratio nanogratings, enhancing the surface area by more than a factor of 15 over mm^2 regions of the chip. The nanograting sidewalls were doped with nitrogen-vacancy (NV) centers so that more than 10 million NV centers in a (25 micrometer)^2 laser spot are located close enough to the diamond surface (5 nm) to detect the NMR spectrum of 1 pL of fluid lying within adjacent nanograting grooves. The platform was used to perform 1H and 19F NMR spectroscopy at room temperature in magnetic fields below 50 mT. Using a solution of CsF in glycerol, we demonstrate that 4 +/- 2 x 10^12 19F spins in a 1 pL volume, can be detected with a signal-to-noise ratio of 3 in 1 s integration. This represents nearly two orders of magnitude improvement in concentration sensitivity over previous NV and picoliter NMR studies.
△ Less
Submitted 5 January, 2017;
originally announced January 2017.
-
Highly spin-polarized deuterium atoms from the UV dissociation of Deuterium Iodide
Authors:
D. Sofikitis,
P. Glodic,
G. Koumarianou,
H. Jiang,
L. Bougas,
P. C. Samartzis,
A. Andreev,
T. P. Rakitzis
Abstract:
We report the production of highly spin-polarized Deuterium atoms via photodissociation of deuterium iodide at 270 nm. The velocity distribution of both the deuterium and iodine photodissociation products is performed via velocity map** slice-imaging. Additionally, the angular momentum polarization of the iodine products is studied using polarization-sensitive ionization schemes. The results are…
▽ More
We report the production of highly spin-polarized Deuterium atoms via photodissociation of deuterium iodide at 270 nm. The velocity distribution of both the deuterium and iodine photodissociation products is performed via velocity map** slice-imaging. Additionally, the angular momentum polarization of the iodine products is studied using polarization-sensitive ionization schemes. The results are consistent with excitation of the $A^1Π_1$ state followed by adiabatic dissociation. The process produces $\sim$100\% electronically polarized deuterium atoms at the time of dissociation, which is then converted to $\sim 60\%$ nuclear D polarization after $\sim 1.6$ ns. These production times for hyperpolarized deuterium allow collision-limited densities of $\sim 10^{18}$ cm$^{-3}$, which is $\sim 10^6$ times higher than conventional (Stern-Gerlach separation) methods. We discuss how such high-density hyperpolarized deuterium atoms can be combined with laser fusion to measure polarized D-D fusion cross sections.
△ Less
Submitted 1 November, 2016; v1 submitted 17 October, 2016;
originally announced October 2016.
-
Microwave-free magnetometry with nitrogen-vacancy centers in diamond
Authors:
Arne Wickenbrock,
Huijie Zheng,
Lykourgos Bougas,
Nathan Leefer,
Samer Afach,
Andrey Jarmola,
Victor M. Acosta,
Dmitry Budker
Abstract:
We use magnetic-field-dependent features in the photoluminescence of negatively charged nitrogen-vacancy centers to measure magnetic fields without the use of microwaves. In particular, we present a magnetometer based on the level anti-crossing in the triplet ground state at 102.4 mT with a demonstrated noise floor of 6 nT/$\sqrt{\text{Hz}}$, limited by the intensity noise of the laser and the per…
▽ More
We use magnetic-field-dependent features in the photoluminescence of negatively charged nitrogen-vacancy centers to measure magnetic fields without the use of microwaves. In particular, we present a magnetometer based on the level anti-crossing in the triplet ground state at 102.4 mT with a demonstrated noise floor of 6 nT/$\sqrt{\text{Hz}}$, limited by the intensity noise of the laser and the performance of the background-field power supply. The technique presented here can be useful in applications where the sensor is placed closed to conductive materials, e.g. magnetic induction tomography or magnetic field map**, and in remote-sensing applications since principally no electrical access is needed.
△ Less
Submitted 9 June, 2016;
originally announced June 2016.
-
Search for ultralight scalar dark matter with atomic spectroscopy
Authors:
Ken Van Tilburg,
Nathan Leefer,
Lykourgos Bougas,
Dmitry Budker
Abstract:
We report new limits on ultralight scalar dark matter (DM) with dilaton-like couplings to photons that can induce oscillations in the fine-structure constant alpha. Atomic dysprosium exhibits an electronic structure with two nearly degenerate levels whose energy splitting is sensitive to changes in alpha. Spectroscopy data for two isotopes of dysprosium over a two-year span is analyzed for coheren…
▽ More
We report new limits on ultralight scalar dark matter (DM) with dilaton-like couplings to photons that can induce oscillations in the fine-structure constant alpha. Atomic dysprosium exhibits an electronic structure with two nearly degenerate levels whose energy splitting is sensitive to changes in alpha. Spectroscopy data for two isotopes of dysprosium over a two-year span is analyzed for coherent oscillations with angular frequencies below 1 rad/s. No signal consistent with a DM coupling is identified, leading to new constraints on dilaton-like photon couplings over a wide mass range. Under the assumption that the scalar field comprises all of the DM, our limits on the coupling exceed those from equivalence-principle tests by up to 4 orders of magnitude for masses below 3 * 10^-18 eV. Excess oscillatory power, inconsistent with fine-structure variation, is detected in a control channel, and is likely due to a systematic effect. Our atomic spectroscopy limits on DM are the first of their kind, and leave substantial room for improvement with state-of-the-art atomic clocks.
△ Less
Submitted 8 April, 2015; v1 submitted 23 March, 2015;
originally announced March 2015.
-
Towards a new measurement of parity violation in dysprosium
Authors:
N. Leefer,
L. Bougas,
D. Antypas,
D. Budker
Abstract:
The dysprosium parity violation experiment concluded nearly 17 years ago with an upper limit on weak interaction induced mixing of nearly degenerate, opposite parity states in atomic dysprosium. While that experiment was limited in sensitivity by statistics, a new apparatus constructed in the interim for radio-frequency spectroscopy is expected to provide significant improvements to the statistica…
▽ More
The dysprosium parity violation experiment concluded nearly 17 years ago with an upper limit on weak interaction induced mixing of nearly degenerate, opposite parity states in atomic dysprosium. While that experiment was limited in sensitivity by statistics, a new apparatus constructed in the interim for radio-frequency spectroscopy is expected to provide significant improvements to the statistical sensitivity. Preliminary work from the new PV experiment in dysprosium is presented with a discussion of the current statistical sensitivity and outlook.
△ Less
Submitted 3 December, 2014;
originally announced December 2014.
-
Evanescent-wave and open-air chiral sensing via signal-reversing cavity-enhanced polarimetry
Authors:
Dimitris Sofikitis,
Lykourgos Bougas,
Georgios E. Katsoprinakis,
Alexandros K. Spiliotis,
Benoit Loppinet,
T. Peter Rakitzis
Abstract:
Sensing chirality is of fundamental importance to many fields, including analytical and biological chemistry, pharmacology, and fundamental physics. Recent developments have extended optical chiral sensing using microwaves, fs pulses, superchiral light, and photoionization. The most widely used methods are the traditional methods of circular dichroism and optical rotation (OR). However, chiral sig…
▽ More
Sensing chirality is of fundamental importance to many fields, including analytical and biological chemistry, pharmacology, and fundamental physics. Recent developments have extended optical chiral sensing using microwaves, fs pulses, superchiral light, and photoionization. The most widely used methods are the traditional methods of circular dichroism and optical rotation (OR). However, chiral signals are typically very weak, and their measurement is limited by larger time-dependent backgrounds and by imperfect and slow subtraction procedures. Here, we demonstrate a pulsed-laser bowtie-cavity-enhanced polarimeter with counter-propagating beams, which solves these background problems: the chiral signals are enhanced by the number of cavity passes; the effects of linear birefringence are suppressed by a large induced intracavity Faraday rotation; and rapid signal reversals are effected by reversing the Faraday rotation and subtracting signals from the counter-propagating beams. These advantages allow measurements of absolute chiral signals in environments where background subtractions are not feasible: we measure optical rotation from chiral vapour in open air, and from chiral liquids in the evanescent wave (EW) produced by total internal reflection at a prism surface. EW-OR of (+)-maltodextrin and (-)-fructose solutions confirm the Drude-Condon model for Maxwell's equations in isotropic optically active media. In particular, the effective optical rotation path length, near index matching, is equal to the Goos-Hänchen shift of the EW. The limits of this polarimeter, when using a continuous-wave laser locked to a stable high-finesse cavity, should match sensitivity measurements for linear birefringence ($3\times 10^{-13}$ rad), which is several orders of magnitude more sensitive than current chiral detection limits, transforming the power of chiral sensing in many fields.
△ Less
Submitted 27 May, 2014;
originally announced May 2014.
-
Stark shift and parity non-conservation for near-degenerate states of xenon
Authors:
L. Bougas,
G. E. Katsoprinakis,
D. Sofikitis,
T. P. Rakitzis,
P. C. Samartzis,
T. N. Kitsopoulos,
J. Sapirstein,
D. Budker,
V. A. Dzuba,
V. V. Flambaum,
M. G. Kozlov
Abstract:
We identify a pair of near-degenerate states of opposite parity in atomic Xe, the $5p^5 10s \,\, ^2[3/2]_2^o$ at $\rm{E}=94759.927$ cm$^{-1}$ and $5p^5 6f \,\, ^2[5/2]_2$ at $\rm{E}= 94759.935$ cm$^{-1}$, for which parity- and time-odd effects are expected to be enhanced by the small energy separation. We present theoretical calculations which indicate narrow widths for both states and we report a…
▽ More
We identify a pair of near-degenerate states of opposite parity in atomic Xe, the $5p^5 10s \,\, ^2[3/2]_2^o$ at $\rm{E}=94759.927$ cm$^{-1}$ and $5p^5 6f \,\, ^2[5/2]_2$ at $\rm{E}= 94759.935$ cm$^{-1}$, for which parity- and time-odd effects are expected to be enhanced by the small energy separation. We present theoretical calculations which indicate narrow widths for both states and we report a calculated value for the weak matrix element, arising from configuration mixing, of $|W|=2.1$ Hz for $^{132}$Xe. In addition, we measured the Stark effect of the $5p^5\,6f$ $^2[5/2]_{2}$ and $5p^5 \,6f \ ^2[3/2]_2$ ($\rm{E} =94737.121\,\rm{cm}^{-1}$) states. The Stark-shift of the $6f$ states is observed to be negative, revealing the presence of nearby $6g$ states at higher energies, which have not been observed before. The Stark-shift measurements imply an upper limit on the weak matrix element of $|W|\!<\!5$ Hz for the near-degenerate states ($10s \,\, ^2[3/2]_2^o$ and $6f \,\, ^2[5/2]_2$), which is in agreement with the presented calculations.
△ Less
Submitted 19 March, 2014;
originally announced March 2014.
-
Fundamentals of Cavity-Enhanced Polarimetry for Parity-Nonconserving Optical Rotation Measurements: Application to Xe, Hg and I
Authors:
L. Bougas,
G. E. Katsoprinakis,
W. von Klitzing,
T. P. Rakitzis
Abstract:
We present the theoretical basis of a cavity-enhanced polarimetric scheme for the measurement of parity-nonconserving (PNC) optical rotation. We discuss the possibility of detecting PNC optical rotation in accessible transitions in metastable Xe and Hg, and ground state I. In particular, the physics of the PNC optical rotation is presented, and we explore the lineshape effects on the expected PNC…
▽ More
We present the theoretical basis of a cavity-enhanced polarimetric scheme for the measurement of parity-nonconserving (PNC) optical rotation. We discuss the possibility of detecting PNC optical rotation in accessible transitions in metastable Xe and Hg, and ground state I. In particular, the physics of the PNC optical rotation is presented, and we explore the lineshape effects on the expected PNC optical rotation signals. Furthermore, we present an analysis of the eigenpolarizations of the cavity-enhanced polarimeter, which is necessary for understanding the measurement procedure and the ability of employing robust background subtraction procedures using two novel signal reversals. Using recent atomic structure theoretical calculations, we present simulations of the PNC optical rotation signals for all proposed transitions, assuming a range of experimentally feasible parameters. Finally, the possibility of performing sensitive measurements of the nuclear-spin-dependent PNC effects is investigated, for the odd-neutron nuclei $^{129}$Xe and $^{199}$Hg, and the odd-proton nucleus $^{127}$I.
△ Less
Submitted 22 November, 2013; v1 submitted 19 November, 2013;
originally announced November 2013.
-
Calculation of parity non-conserving optical rotation in iodine at 1315 nm
Authors:
G. E. Katsoprinakis,
L. Bougas,
T. P. Rakitzis,
V. A. Dzuba,
V. V. Flambaum
Abstract:
We examine the feasibility of a parity non-conserving (PNC) optical rotation experiment for the $^2$P$_{3/2}\rightarrow ^2$P$_{1/2}$ transition of atomic iodine at 1315 nm. The calculated $E1_{\rm PNC}$ to $M1$ amplitude ratio is $R=0.80(16)\times 10^{-8}$. We show that very large PNC rotations (greater than 10 $μ$rad) are obtained for iodine-atom column densities of $\sim 10^{22}$ cm$^{-2}$, whic…
▽ More
We examine the feasibility of a parity non-conserving (PNC) optical rotation experiment for the $^2$P$_{3/2}\rightarrow ^2$P$_{1/2}$ transition of atomic iodine at 1315 nm. The calculated $E1_{\rm PNC}$ to $M1$ amplitude ratio is $R=0.80(16)\times 10^{-8}$. We show that very large PNC rotations (greater than 10 $μ$rad) are obtained for iodine-atom column densities of $\sim 10^{22}$ cm$^{-2}$, which can be produced by increasing the effective interaction pathlength by a factor of $\sim 10^4$ with a high-finesse optical cavity. The simulated signals indicate that measurement of the nuclear anapole moment is feasible, and that a 1% PNC precision measurement should resolve the inconsistency between previous measurements in Cs and Tl.
△ Less
Submitted 1 April, 2013; v1 submitted 29 January, 2013;
originally announced January 2013.