Skip to main content

Showing 1–6 of 6 results for author: Botnar, R

.
  1. arXiv:2307.14363  [pdf, other

    eess.IV cs.LG

    Unsupervised reconstruction of accelerated cardiac cine MRI using Neural Fields

    Authors: Tabita Catalán, Matías Courdurier, Axel Osses, René Botnar, Francisco Sahli Costabal, Claudia Prieto

    Abstract: Cardiac cine MRI is the gold standard for cardiac functional assessment, but the inherently slow acquisition process creates the necessity of reconstruction approaches for accelerated undersampled acquisitions. Several regularization approaches that exploit spatial-temporal redundancy have been proposed to reconstruct undersampled cardiac cine MRI. More recently, methods based on supervised deep l… ▽ More

    Submitted 24 July, 2023; originally announced July 2023.

  2. arXiv:2301.02702  [pdf, ps, other

    physics.med-ph

    KomaMRI.jl: An Open-Source Framework for General MRI Simulations with GPU Acceleration

    Authors: Carlos Castillo-Passi, Ronal Coronado, Gabriel Varela-Mattatall, Carlos Alberola-López, René Botnar, Pablo Irarrazaval

    Abstract: Purpose: To develop an open-source, high-performance, easy-to-use, extensible, cross-platform, and general MRI simulation framework (Koma). Methods: Koma was developed using the Julia programming language. Like other MRI simulators, it solves the Bloch equations with CPU and GPU parallelization. The inputs are the scanner parameters, the phantom, and the pulse sequence that is Pulseq-compatible.… ▽ More

    Submitted 6 January, 2023; originally announced January 2023.

    Comments: 13 pages, 7 figures, 2 tables

  3. arXiv:2107.09060  [pdf

    eess.IV cs.AI cs.CV cs.LG

    LAPNet: Non-rigid Registration derived in k-space for Magnetic Resonance Imaging

    Authors: Thomas Küstner, Jiazhen Pan, Haikun Qi, Gastao Cruz, Christopher Gilliam, Thierry Blu, Bin Yang, Sergios Gatidis, René Botnar, Claudia Prieto

    Abstract: Physiological motion, such as cardiac and respiratory motion, during Magnetic Resonance (MR) image acquisition can cause image artifacts. Motion correction techniques have been proposed to compensate for these types of motion during thoracic scans, relying on accurate motion estimation from undersampled motion-resolved reconstruction. A particular interest and challenge lie in the derivation of re… ▽ More

    Submitted 19 July, 2021; originally announced July 2021.

  4. arXiv:2012.11974  [pdf, other

    eess.IV

    Complementary Time-Frequency Domain Networks for Dynamic Parallel MR Image Reconstruction

    Authors: Chen Qin, **ming Duan, Kerstin Hammernik, Jo Schlemper, Thomas Küstner, René Botnar, Claudia Prieto, Anthony N. Price, Joseph V. Hajnal, Daniel Rueckert

    Abstract: Purpose: To introduce a novel deep learning based approach for fast and high-quality dynamic multi-coil MR reconstruction by learning a complementary time-frequency domain network that exploits spatio-temporal correlations simultaneously from complementary domains. Theory and Methods: Dynamic parallel MR image reconstruction is formulated as a multi-variable minimisation problem, where the data… ▽ More

    Submitted 18 June, 2021; v1 submitted 22 December, 2020; originally announced December 2020.

    Comments: Accepted by Magnetic Resonance in Medicine

  5. arXiv:1812.08155  [pdf, other

    cs.CV

    Magnetic Resonance Fingerprinting using Recurrent Neural Networks

    Authors: Ilkay Oksuz, Gastao Cruz, James Clough, Aurelien Bustin, Nicolo Fuin, Rene M. Botnar, Claudia Prieto, Andrew P. King, Julia A. Schnabel

    Abstract: Magnetic Resonance Fingerprinting (MRF) is a new approach to quantitative magnetic resonance imaging that allows simultaneous measurement of multiple tissue properties in a single, time-efficient acquisition. Standard MRF reconstructs parametric maps using dictionary matching and lacks scalability due to computational inefficiency. We propose to perform MRF map reconstruction using a recurrent neu… ▽ More

    Submitted 19 December, 2018; originally announced December 2018.

    Comments: Accepted for ISBI 2018

  6. arXiv:1810.12185  [pdf, other

    cs.CV

    Automatic CNN-based detection of cardiac MR motion artefacts using k-space data augmentation and curriculum learning

    Authors: Ilkay Oksuz, Bram Ruijsink, Esther Puyol-Anton, James Clough, Gastao Cruz, Aurelien Bustin, Claudia Prieto, Rene Botnar, Daniel Rueckert, Julia A. Schnabel, Andrew P. King

    Abstract: Good quality of medical images is a prerequisite for the success of subsequent image analysis pipelines. Quality assessment of medical images is therefore an essential activity and for large population studies such as the UK Biobank (UKBB), manual identification of artefacts such as those caused by unanticipated motion is tedious and time-consuming. Therefore, there is an urgent need for automatic… ▽ More

    Submitted 11 December, 2018; v1 submitted 29 October, 2018; originally announced October 2018.

    Comments: Submitted to Medical Image Analysis