-
Performance of CVD diamond detectors for single ion beam-tagging applications in hadrontherapy monitoring
Authors:
Sébastien Curtoni,
Marie-Laure Gallin-Martel,
Sara Marcatili,
Latifa Abbassi,
Alexandre Bes,
Germain Bosson,
Johann Collot,
Thierry Crozes,
Denis Dauvergne,
Wout De Nolf,
Pierre Everaere,
Laurent Gallin-Martel,
Abderrahmane Ghimouz,
Ferid Haddad,
Christophe Hoarau,
Jean-Yves Hostachy,
Charbel Koumeir,
Ana Lacoste,
Vincent Métivier,
John Morse,
Jean-François Motte,
Jean-François Muraz,
Freddy Poirier,
Fatah Ellah Rarbi,
Olivier Rossetto
, et al. (4 additional authors not shown)
Abstract:
In the context of online ion range verification in particle therapy, the CLaRyS collaboration is develo** Prompt-Gamma (PG) detection systems. The originality in the CLaRyS approach is to use a beam-tagging hodoscope in coincidence with the gamma detectors to provide both temporal and spatial information of the incoming ions. The ion range sensitivity of such PG detection systems could be improv…
▽ More
In the context of online ion range verification in particle therapy, the CLaRyS collaboration is develo** Prompt-Gamma (PG) detection systems. The originality in the CLaRyS approach is to use a beam-tagging hodoscope in coincidence with the gamma detectors to provide both temporal and spatial information of the incoming ions. The ion range sensitivity of such PG detection systems could be improved by detecting single ions with a 100 ps ($σ$) time resolution, through a quality assurance procedure at low beam intensity at the beginning of the treatment session. This work presents the investigations led to assess the performance of Chemical Vapor Deposition (CVD) diamond detectors to fulfill these requirements. A $^{90}$Sr beta source, 68 MeV protons, 95 MeV/u carbon ions and a synchrotron X-ray pulsed beam were used to measure the time resolution, single ion detection efficiency and proton counting capability of various CVD diamond samples. An offline technique, based on double-sided readout with fast current preamplifiers and used to improve the signal-to-noise ratio, is also presented. The different tests highlighted Time-Of-Flight resolutions ranging from 13 ps ($σ$) to 250 ps ($σ$), depending on the experimental conditions. The single 68 MeV proton detection efficiency of various large area polycrystalline (pCVD) samples was measured to be $>$96% using coincidence measurements with a single-crystal reference detector. Single-crystal CVD (sCVD) diamond proved to be able to count a discrete number of simultaneous protons while it was not achievable with a polycrystalline sample. Considering the results of the present study, two diamond hodoscope demonstrators are under development: one based on sCVD, and one of larger size based on pCVD. They will be used for the purpose of single ion as well as ion bunches detection, either at reduced or clinical beam intensities.
△ Less
Submitted 23 August, 2021; v1 submitted 11 May, 2021;
originally announced May 2021.
-
RF pulse amplifier for CVD-diamond particle detectors
Authors:
C. Hoarau,
G. Bosson,
J. -L. Bouly,
S. Curtoni,
D. Dauvergne,
P. Everaere,
M. -L. Gallin-Martel,
S. Marcatili,
J. -F. Muraz,
A. Portier,
N. Rosuel
Abstract:
This article introduces a design of a Low Noise Amplifier (LNA), for the field of diamond particle detectors. This amplifier is described from simulation to measurements, which include pulses from α particles detection. In hadron therapy, with high-frequency pulsed particle beams, the diamond detector is a promising candidate for beam monitoring and time-stam**, with prerequisite of fast electro…
▽ More
This article introduces a design of a Low Noise Amplifier (LNA), for the field of diamond particle detectors. This amplifier is described from simulation to measurements, which include pulses from α particles detection. In hadron therapy, with high-frequency pulsed particle beams, the diamond detector is a promising candidate for beam monitoring and time-stam**, with prerequisite of fast electronics. The LNA is designed with surface mounted components and RF layout techniques to control costs and to allow timing performance suitable for sub-nanosecond edges of pulses. Also this amplifier offers the possibility of high voltage biasing, a characteristic essential for driving diamond detectors. Finally the greatest asset of this study is certainly the minimization of the power consumption, which allows us to consider designs with multiple amplifiers, in limited space, for striped diamond detectors.
△ Less
Submitted 22 February, 2021;
originally announced February 2021.
-
Fast neutron spectroscopy from 1 MeV up to 15 MeV with Mimac-FastN, a mobile and directional fast neutron spectrometer
Authors:
Nadine Sauzet,
Daniel Santos,
Olivier Guillaudin,
Germain Bosson,
Joël Bouvier,
Thierry Descombes,
Marc Marton,
Jean-François Muraz
Abstract:
In the frame of direct dark matter search, the fast neutrons producing elastic collisions are the ultimate background. The MIMAC (MIcro-tpc MAtrix Chambers) project has developed a directional detector providing the directional signature to discriminate them based on 3D nuclear tracks reconstruction. The MIMAC team of the LPSC has adapted one MIMAC chamber as a portable fast neutron spectrometer,…
▽ More
In the frame of direct dark matter search, the fast neutrons producing elastic collisions are the ultimate background. The MIMAC (MIcro-tpc MAtrix Chambers) project has developed a directional detector providing the directional signature to discriminate them based on 3D nuclear tracks reconstruction. The MIMAC team of the LPSC has adapted one MIMAC chamber as a portable fast neutron spectrometer, the Mimac-FastN detector, having a very large neutron energy range (10 keV - 600 MeV) with different gas mixtures and pressures. The present paper shows its main features and functionality and demonstrates its potential in the energy range from 1 MeV to 15 MeV at the GENESIS neutron source facility of LPSC.
△ Less
Submitted 12 March, 2020; v1 submitted 10 June, 2019;
originally announced June 2019.
-
The STEREO Experiment
Authors:
N. Allemandou,
H. Almazán,
P. del Amo Sanchez,
L. Bernard,
C. Bernard,
A. Blanchet,
A. Bonhomme,
G. Bosson,
O. Bourrion,
J. Bouvier,
C. Buck,
V. Caillot,
M. Chala,
P. Champion,
P. Charon,
A. Collin,
P. Contrepois,
G. Coulloux,
B. Desbrières,
G. Deleglise,
W. El Kanawati,
J. Favier,
S. Fuard,
I. Gomes Monteiro,
B. Gramlich
, et al. (40 additional authors not shown)
Abstract:
The STEREO experiment is a very short baseline reactor antineutrino experiment aiming at testing the hypothesis of light sterile neutrinos as an explanation of the deficit of the observed neutrino interaction rate with respect to the predicted rate, known as the Reactor Antineutrino Anomaly. The detector center is located 10 m away from the compact, highly $^{235}$U enriched core of the research n…
▽ More
The STEREO experiment is a very short baseline reactor antineutrino experiment aiming at testing the hypothesis of light sterile neutrinos as an explanation of the deficit of the observed neutrino interaction rate with respect to the predicted rate, known as the Reactor Antineutrino Anomaly. The detector center is located 10 m away from the compact, highly $^{235}$U enriched core of the research nuclear reactor of the Institut Laue Langevin in Grenoble, France. This paper describes the STEREO site, the detector components and associated shielding designed to suppress the external sources of background which were characterized on site. It reports the performances in terms of detector response and energy reconstruction.
△ Less
Submitted 14 August, 2018; v1 submitted 24 April, 2018;
originally announced April 2018.
-
The NIKA2 instrument at 30-m IRAM telescope: performance and results
Authors:
A. Catalano,
R. Adam,
P. A. R. Ade,
P.,
André,
H. Aussel,
A. Beelen,
A. Benoit,
A. Bideaud,
N. Billot,
O. Bourrion,
M. Calvo,
B. Comis,
M. De Petris,
F. -X. Désert,
S. Doyle,
E. F. C. Driessen,
J. Goupy,
C. Kramer,
G. Lagache,
S. Leclercq,
J. -F. Lestrade,
J. F. Macìas-Pérez,
P. Mauskopf,
F. Mayet
, et al. (62 additional authors not shown)
Abstract:
The New IRAM KID Arrays 2 (NIKA2) consortium has just finished installing and commissioning a millimetre camera on the IRAM 30 m telescope. It is a dual-band camera operating with three frequency multiplexed kilo-pixels arrays of Lumped Element Kinetic Inductance Detectors (LEKID) cooled at 150 mK, designed to observe the intensity and polarisation of the sky at 260 and 150 GHz (1.15 and 2 mm). NI…
▽ More
The New IRAM KID Arrays 2 (NIKA2) consortium has just finished installing and commissioning a millimetre camera on the IRAM 30 m telescope. It is a dual-band camera operating with three frequency multiplexed kilo-pixels arrays of Lumped Element Kinetic Inductance Detectors (LEKID) cooled at 150 mK, designed to observe the intensity and polarisation of the sky at 260 and 150 GHz (1.15 and 2 mm). NIKA2 is today an IRAM resident instrument for millimetre astronomy, such as Intra Cluster Medium from intermediate to distant clusters and so for the follow-up of Planck satellite detected clusters, high redshift sources and quasars, early stages of star formation and nearby galaxies emission. We present an overview of the instrument performance as it has been evaluated at the end of the commissioning phase.
△ Less
Submitted 4 February, 2018; v1 submitted 11 December, 2017;
originally announced December 2017.
-
Readout technologies for directional WIMP Dark Matter detection
Authors:
J. B. R. Battat,
I. G. Irastorza,
A. Aleksandrov,
M. Ali Guler,
T. Asada,
E. Baracchini,
J. Billard,
G. Bosson,
O. Bourrion,
J. Bouvier,
A. Buonaura,
K. Burdge,
S. Cebrian,
P. Colas,
L. Consiglio,
T. Dafni,
N. D'Ambrosio,
C. Deaconu,
G. De Lellis,
T. Descombes,
A. Di Crescenzo,
N. Di Marco,
G. Druitt,
R. Eggleston,
E. Ferrer-Ribas
, et al. (68 additional authors not shown)
Abstract:
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial…
▽ More
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.
△ Less
Submitted 6 October, 2016;
originally announced October 2016.
-
Production of highly-polarized positrons using polarized electrons at MeV energies
Authors:
D. Abbott,
P. Adderley,
A. Adeyemi,
P. Aguilera,
M. Ali,
H. Areti,
M. Baylac,
J. Benesch,
G. Bosson,
B. Cade,
A. Camsonne,
L. S. Cardman,
J. Clark,
P. Cole,
S. Covert,
C. Cuevas,
O. Dadoun,
D. Dale,
H. Dong,
J. Dumas,
E. Fanchini,
T. Forest,
E. Forman,
A. Freyberger,
E. Froidefond
, et al. (40 additional authors not shown)
Abstract:
The Polarized Electrons for Polarized Positrons experiment at the injector of the Continuous Electron Beam Accelerator Facility has demonstrated for the first time the efficient transfer of polarization from electrons to positrons produced by the polarized bremsstrahlung radiation induced by a polarized electron beam in a high-$Z$ target. Positron polarization up to 82\% have been measured for an…
▽ More
The Polarized Electrons for Polarized Positrons experiment at the injector of the Continuous Electron Beam Accelerator Facility has demonstrated for the first time the efficient transfer of polarization from electrons to positrons produced by the polarized bremsstrahlung radiation induced by a polarized electron beam in a high-$Z$ target. Positron polarization up to 82\% have been measured for an initial electron beam momentum of 8.19~MeV/$c$, limited only by the electron beam polarization. This technique extends polarized positron capabilities from GeV to MeV electron beams, and opens access to polarized positron beam physics to a wide community.
△ Less
Submitted 28 June, 2016;
originally announced June 2016.
-
MIMAC low energy electron-recoil discrimination measured with fast neutrons
Authors:
Q. Riffard,
D. Santos,
O. Guillaudin,
G. Bosson,
O. Bourrion,
J. Bouvier,
T. Descombes,
J. -F. Muraz,
L. Lebreton,
D. Maire,
P. Colas,
I. Giomataris,
J. Busto,
D. Fouchez,
J. Brunner,
C. Tao
Abstract:
MIMAC (MIcro-TPC MAtrix of Chambers) is a directional WIMP Dark Matter detector project. Direct dark matter experiments need a high level of electron/recoil discrimination to search for nuclear recoils produced by WIMP-nucleus elastic scattering. In this paper, we proposed an original method for electron event rejection based on a multivariate analysis applied to experimental data acquired using m…
▽ More
MIMAC (MIcro-TPC MAtrix of Chambers) is a directional WIMP Dark Matter detector project. Direct dark matter experiments need a high level of electron/recoil discrimination to search for nuclear recoils produced by WIMP-nucleus elastic scattering. In this paper, we proposed an original method for electron event rejection based on a multivariate analysis applied to experimental data acquired using monochromatic neutron fields. This analysis shows that a $10^5$ rejection power is reachable for electron/recoil discrimination. Moreover, the efficiency was estimated by a Monte-Carlo simulation showing that a 105 electron rejection power is reached with a $86.49\pm 0.17$\% nuclear recoil efficiency considering the full energy range and $94.67\pm0.19$\% considering a 5~keV lower threshold.
△ Less
Submitted 4 July, 2016; v1 submitted 4 February, 2016;
originally announced February 2016.
-
NIKEL_AMC: Readout electronics for the NIKA2 experiment
Authors:
O. Bourrion,
A. Benoit,
J. L. Bouly,
J. Bouvier,
G. Bosson,
M. Calvo,
A. Catalano,
J. Goupy,
C. Li,
J. F. Macías-Pérez,
A. Monfardini,
D. Tourres,
N. Ponchant,
C. Vescovi
Abstract:
The New Iram Kid Arrays-2 (NIKA2) instrument has recently been installed at the IRAM 30 m telescope. NIKA2 is a state-of-art instrument dedicated to mm-wave astronomy using microwave kinetic inductance detectors (KID) as sensors. The three arrays installed in the camera, two at 1.25 mm and one at 2.05 mm, feature a total of 3300 KIDs. To instrument these large array of detectors, a specifically de…
▽ More
The New Iram Kid Arrays-2 (NIKA2) instrument has recently been installed at the IRAM 30 m telescope. NIKA2 is a state-of-art instrument dedicated to mm-wave astronomy using microwave kinetic inductance detectors (KID) as sensors. The three arrays installed in the camera, two at 1.25 mm and one at 2.05 mm, feature a total of 3300 KIDs. To instrument these large array of detectors, a specifically designed electronics, composed of 20 readout boards and hosted in three microTCA crates, has been developed. The implemented solution and the achieved performances are presented in this paper. We find that multiplexing factors of up to 400 detectors per board can be achieved with homogeneous performance across boards in real observing conditions, and a factor of more than 3 decrease in volume with respect to previous generations.
△ Less
Submitted 25 October, 2016; v1 submitted 3 February, 2016;
originally announced February 2016.
-
Trigger and readout electronics for the STEREO experiment
Authors:
O. Bourrion,
J. L. Bouly,
J. Bouvier,
G. Bosson,
V. Helaine,
J. Lamblin,
C. Li,
F. Montanet,
J. S. Real,
T. Salagnac,
N. Ponchant,
A. Stutz,
D. Tourres,
C. Vescovi,
S. Zsoldos
Abstract:
The STEREO experiment will search for a sterile neutrino by measuring the anti-neutrino energy spectrum as a function of the distance from the source, the ILL nuclear reactor. A dedicated electronic system, hosted in a single microTCA crate, was designed for this experiment. It performs triggering in two stages with various selectable conditions, processing and readout via UDP/IPBUS of 68 photomul…
▽ More
The STEREO experiment will search for a sterile neutrino by measuring the anti-neutrino energy spectrum as a function of the distance from the source, the ILL nuclear reactor. A dedicated electronic system, hosted in a single microTCA crate, was designed for this experiment. It performs triggering in two stages with various selectable conditions, processing and readout via UDP/IPBUS of 68 photomultiplier signals continuously digitized at 250 MSPS. Additionally, for detector performance monitoring, the electronics allow on-line calibration by driving LED synchronously with the data acquisition. This paper describes the electronics requirements, architecture and the performances achieved.
△ Less
Submitted 18 January, 2016; v1 submitted 28 October, 2015;
originally announced October 2015.
-
First detection of tracks of radon progeny recoils by MIMAC
Authors:
Q. Riffard,
D. Santos,
G. Bosson,
O. Bourrion,
T. Descombes,
C. Fourel,
O. Guillaudin,
J. -F. Muraz,
P. Colas,
E. Ferrer-Ribas,
I. Giomataris,
J. Busto,
D. Fouchez,
C. Tao,
L. Lebreton,
D. Maire
Abstract:
The MIMAC experiment is a $μ$-TPC matrix project for directional dark matter search. Directional detection is a strategy based on the measurement of the WIMP flux anisotropy due to the solar system motion with respect to the dark matter halo. The main purpose of MIMAC project is the measurement of the energy and the direction of nuclear recoils in 3D produced by elastic scattering of WIMPs. Since…
▽ More
The MIMAC experiment is a $μ$-TPC matrix project for directional dark matter search. Directional detection is a strategy based on the measurement of the WIMP flux anisotropy due to the solar system motion with respect to the dark matter halo. The main purpose of MIMAC project is the measurement of the energy and the direction of nuclear recoils in 3D produced by elastic scattering of WIMPs. Since June 2012 a bi-chamber prototype is operating at the Modane underground laboratory. In this paper, we report the first ionization energy and 3D track observations of nuclear recoils produced by the radon progeny. This measurement shows the capability of the MIMAC detector and opens the possibility to explore the low energy recoil directionality signature.
△ Less
Submitted 20 June, 2017; v1 submitted 22 April, 2015;
originally announced April 2015.
-
Limiting Lamport Exposure to Distant Failures in Globally-Managed Distributed Systems
Authors:
Cristina Băsescu,
Georgia Fragkouli,
Enis Ceyhun Alp,
Michael F. Nowlan,
Jose M. Faleiro,
Gaylor Bosson,
Kelong Cong,
Pierluca Borsò-Tan,
Vero Estrada-Galiñanes,
Bryan Ford
Abstract:
Globalized computing infrastructures offer the convenience and elasticity of globally managed objects and services, but lack the resilience to distant failures that localized infrastructures such as private clouds provide. Providing both global management and resilience to distant failures, however, poses a fundamental problem for configuration services: How to discover a possibly migratory, stron…
▽ More
Globalized computing infrastructures offer the convenience and elasticity of globally managed objects and services, but lack the resilience to distant failures that localized infrastructures such as private clouds provide. Providing both global management and resilience to distant failures, however, poses a fundamental problem for configuration services: How to discover a possibly migratory, strongly-consistent service/object in a globalized infrastructure without dependencies on globalized state? Limix is the first metadata configuration service that addresses this problem. With Limix, global strongly-consistent data-plane services and objects are insulated from remote gray failures by ensuring that the definitive, strongly-consistent metadata for any object is always confined to the same region as the object itself. Limix guarantees availability bounds: any user can continue accessing any strongly consistent object that matters to the user located at distance $Δ$ away, insulated from failures outside a small multiple of $Δ$. We built a Limix metadata service based on CockroachDB. Our experiments on Internet-like networks and on AWS, using realistic trace-driven workloads, show that Limix enables global management and significantly improves availability over the state-of-the-art.
△ Less
Submitted 15 July, 2022; v1 submitted 3 May, 2014;
originally announced May 2014.
-
Measurement of the electron drift velocity for directional dark matter detectors
Authors:
F. Mayet,
J. Billard,
G. Bosson,
O. Bourrion,
O. Guillaudin,
J. Lamblin,
J. P. Richer,
Q. Riffard,
D. Santos,
F. J. Iguaz,
L. Lebreton,
D. Maire
Abstract:
Three-dimensional track reconstruction is a key issue for directional Dark Matter detection. It requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by sim…
▽ More
Three-dimensional track reconstruction is a key issue for directional Dark Matter detection. It requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by simulation. In situ measurement of this key parameter is hence a way to avoid bias in the 3D track reconstruction. We present a dedicated method for the measurement of the electron drift velocity with the MIMAC detector. It is tested on two gas mixtures : $\rm CF_4$ and $\rm CF_4+CHF_3$. We also show that adding $\rm CHF_3$ allows us to lower the electron drift velocity while kee** almost the same Fluorine content of the gas mixture.
△ Less
Submitted 6 January, 2014;
originally announced January 2014.
-
MIMAC: MIcro-tpc MAtrix of Chambers for dark matter directional detection
Authors:
D. Santos,
G. Bosson,
J. L. Bouly,
O. Bourrion,
Ch. Fourel,
O. Guillaudin,
J. Lamblin,
F. Mayet,
J. F. Muraz,
J. P. Richer,
Q. Riffard,
L. Lebreton,
D. Maire,
J. Busto,
J. Brunner,
D. Fouchez
Abstract:
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from neutrons, the ultimate background for dark matter direct detection. This strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last ye…
▽ More
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from neutrons, the ultimate background for dark matter direct detection. This strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based on the direct coupling of large pixelized micromegas with a special developed fast self-triggered electronics showing the feasibility of a new generation of directional detectors. The first bi-chamber prototype has been installed at Modane, underground laboratory in June 2012. The first undergournd background events, the gain stability and calibration are shown. The first spectrum of nuclear recoils showing 3D tracks coming from the radon progeny is presented.
△ Less
Submitted 4 November, 2013;
originally announced November 2013.
-
Measurement of a 127 keV Neutron Field with a micro-TPC Spectrometer
Authors:
D. Maire,
J. Billard,
G. Bosson,
O. Bourrion,
O. Guillaudin,
J. Lamblin,
L. Lebreton,
F. Mayet,
J. Médard,
J. F. Muraz,
M. Petit,
J. P. Richer,
Q. Riffard,
D. Santos
Abstract:
In order to measure the energy of neutron fields, with energy ranging from 8 keV to 1 MeV, a new primary standard is being developed at the IRSN (Institute for Radioprotection and Nuclear Safety). This project, micro-TPC (Micro Time Projection Chamber), carried out in collaboration with the LPSC (Laboratoire de Physique Subatomique et de Cosmologie), is based on the nuclear recoil detector princip…
▽ More
In order to measure the energy of neutron fields, with energy ranging from 8 keV to 1 MeV, a new primary standard is being developed at the IRSN (Institute for Radioprotection and Nuclear Safety). This project, micro-TPC (Micro Time Projection Chamber), carried out in collaboration with the LPSC (Laboratoire de Physique Subatomique et de Cosmologie), is based on the nuclear recoil detector principle. The instrument is presented with the associated method to measure the neutron energy. This article emphasizes the proton energy calibration procedure and energy measurements of a neutron field produced at 127 keV with the IRSN facility AMANDE.
△ Less
Submitted 7 January, 2014; v1 submitted 25 October, 2013;
originally announced October 2013.
-
Development of a microtpc detector as a standard instrument for low energy neutron field characterization
Authors:
D. Maire,
J. Billard,
G. Bosson,
O. Bourrion,
O. Guillaudin,
J. Lamblin,
L. Lebreton,
F. Mayet,
J. Médard,
J-F. Muraz,
J-P. Richer,
Q. Riffard,
D. Santos
Abstract:
In order to measure energy and fluence of neutron fields, with energy ranging from 8 keV to 1 MeV, a new primary standard is being developed at the IRSN (Institute for Radioprotection and Nuclear Safety). This project, micro-TPC (Micro Time Projection Chamber), carried out in collaboration with the LPSC, is based on the nucleus recoil detector principle. The measurement strategy requires track rec…
▽ More
In order to measure energy and fluence of neutron fields, with energy ranging from 8 keV to 1 MeV, a new primary standard is being developed at the IRSN (Institute for Radioprotection and Nuclear Safety). This project, micro-TPC (Micro Time Projection Chamber), carried out in collaboration with the LPSC, is based on the nucleus recoil detector principle. The measurement strategy requires track reconstruction of recoiling nuclei down to a few keV, which can be achieved with a low pressure gaseous detector using a micro-pattern gaseous detector. A gas mixture, mainly isobutane, is used as a n-p converter to detect neutrons into the detection volume. Then electrons, coming from the ionization of the gas by the proton recoil, are collected by the pixelised anode (2D projection). A self-triggered electronics is able to perform the anode readout at a 50 MHz frequency in order to give the third dimension of the track. Then the scattering angle is deduced from this track using algorithms. The charge collection leads to the proton energy, taking into account the ionization quenching factor. This article emphasizes the neutron energy measurements of a monoenergetic neutron field produced at 127 keV. The measurements are compared to Monte Carlo simulations using realistic neutron fields and simulations of the detector response. The discrepancy between experiments and simulations is 5 keV mainly due to the calibration uncertainties of 10%.
△ Less
Submitted 22 October, 2013;
originally announced October 2013.
-
Dark Matter directional detection with MIMAC
Authors:
Q. Riffard,
J. Billard,
G. Bosson,
O. Bourrion,
O. Guillaudin,
J. Lamblin,
F. Mayet,
J. -F. Muraz,
J. -P. Richer,
D. Santos,
L. Lebreton,
D. Maire,
J. Busto,
J. Brunner,
D. Fouchez
Abstract:
Directional detection is a promising direct Dark Matter (DM) search strategy. The angular distribution of the nuclear recoil tracks from WIMP events should present an anisotropy in galactic coordinates. This strategy requires both a measurement of the recoil energy with a threshold of about 5 keV and 3D recoil tracks down to few millimeters.
The MIMAC project, based on a \textmu-TPC matrix, with…
▽ More
Directional detection is a promising direct Dark Matter (DM) search strategy. The angular distribution of the nuclear recoil tracks from WIMP events should present an anisotropy in galactic coordinates. This strategy requires both a measurement of the recoil energy with a threshold of about 5 keV and 3D recoil tracks down to few millimeters.
The MIMAC project, based on a \textmu-TPC matrix, with $CF_4$ and $CHF_3$, is being developed. In June 2012, a bi-chamber prototype was installed at the LSM (Laboratoire Souterrain de Modane). A preliminary analysis of the first four months data taking allowed, for the first time, the observation of recoils from the $\mathrm{^{222}Rn}$ progeny.
△ Less
Submitted 18 June, 2013;
originally announced June 2013.
-
In situ measurement of the electron drift velocity for upcoming directional Dark Matter detectors
Authors:
J. Billard,
F. Mayet,
G. Bosson,
O. Bourrion,
O. Guillaudin,
J. Lamblin,
J. P. Richer,
Q. Riffard,
D. Santos,
F. J. Iguaz,
L. Lebreton,
D. Maire
Abstract:
Three-dimensional track reconstruction is a key issue for directional Dark Matter detection and it requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by…
▽ More
Three-dimensional track reconstruction is a key issue for directional Dark Matter detection and it requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by simulation. In situ measurement of this key parameter is hence needed as it is a way to avoid bias in the 3D track reconstruction. We present a dedicated method for the measurement of the electron drift velocity with the MIMAC detector. It is tested on two gas mixtures: CF4 and CF4 + CHF3. The latter has been chosen for the MIMAC detector as we expect that adding CHF3 to pure CF4 will lower the electron drift velocity. This is a key point for directional Dark Matter as the track sampling along the drift field will be improved while kee** almost the same Fluorine content of the gas mixture. We show that the drift velocity at 50 mbar is reduced by a factor of about 5 when adding 30% of CHF3.
△ Less
Submitted 28 January, 2014; v1 submitted 10 May, 2013;
originally announced May 2013.
-
MIMAC: A micro-tpc matrix for dark matter directional detection
Authors:
D. Santos,
J. Billard,
G. Bosson,
J. L. Bouly,
O. Bourrion,
C. Fourel,
O. Guillaudin,
J. Lamblin,
J. F. Muraz,
F. Mayet,
J. P. Richer,
Q. Riffard,
E. Ferrer,
I. Giomataris,
F. J. Iguaz,
L. Lebreton,
D. Maire
Abstract:
The dark matter directional detection opens a new field in cosmology bringing the possibility to build a map of nuclear recoils that would be able to explore the galactic dark matter halo giving access to a particle characterization of such matter and the shape of the halo. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based o…
▽ More
The dark matter directional detection opens a new field in cosmology bringing the possibility to build a map of nuclear recoils that would be able to explore the galactic dark matter halo giving access to a particle characterization of such matter and the shape of the halo. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based on the direct coupling of large pixelized micromegas with a devoted fast self-triggered electronics showing the feasibility of a new generation of directional detectors. The discovery potential of this search strategy is discussed and illustrated. In June 2012, the first bi-chamber prototype has been installed at Modane Underground Laboratory (LSM) and the first underground background events, the gain stability and calibration are shown.
△ Less
Submitted 8 April, 2013;
originally announced April 2013.
-
A μ-TPC detector for the characterization of low energy neutron fields
Authors:
C. Golabek,
J. Billard,
A. Allaoua,
G. Bosson,
O. Bourrion,
C. Grignon,
O. Guillaudin,
L. Lebreton,
F. Mayet,
M. Petit,
J. -P. Richer,
D. Santos
Abstract:
The AMANDE facility produces monoenergetic neutron fields from 2 keV to 20 MeV for metrological purposes. To be considered as a reference facility, fluence and energy distributions of neutron fields have to be determined by primary measurement standards. For this purpose, a micro Time Projection Chamber is being developed to be dedicated to measure neutron fields with energy ranging from 8 keV up…
▽ More
The AMANDE facility produces monoenergetic neutron fields from 2 keV to 20 MeV for metrological purposes. To be considered as a reference facility, fluence and energy distributions of neutron fields have to be determined by primary measurement standards. For this purpose, a micro Time Projection Chamber is being developed to be dedicated to measure neutron fields with energy ranging from 8 keV up to 1 MeV. In this work we present simulations showing that such a detector, which allows the measurement of the ionization energy and the 3D reconstruction of the recoil nucleus, provides the determination of neutron energy and fluence of these neutron fields.
△ Less
Submitted 12 March, 2012;
originally announced March 2012.
-
MIMAC: A micro-tpc matrix project for directional detection of dark matter
Authors:
D. Santos,
J. Billard,
G. Bosson,
J. L. Bouly,
O. Bourrion,
Ch. Fourel,
O. Guillaudin,
F. Mayet,
J. P. Richer,
A. Delbart,
E. Ferrer,
I. Giomataris,
F. J. Iguaz,
J. P. Mols,
C. Golabek,
L. Lebreton
Abstract:
Directional detection of non-baryonic DarkMatter is a promising search strategy for discriminating WIMP events from background ones. This strategy requires both a measurement of the recoil energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC project, based on a micro-TPC matrix, filled with CF4 and CHF3 is being developed. The first results of a chamber prototype of…
▽ More
Directional detection of non-baryonic DarkMatter is a promising search strategy for discriminating WIMP events from background ones. This strategy requires both a measurement of the recoil energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC project, based on a micro-TPC matrix, filled with CF4 and CHF3 is being developed. The first results of a chamber prototype of this matrix, on low energy nuclear recoils (1H and 19F) obtained with mono-energetic neutron fields are presented. The discovery potential of this search strategy is illustrated by a realistic case accessible to MIMAC.
△ Less
Submitted 7 November, 2011;
originally announced November 2011.
-
Development and validation of a 64 channel front end ASIC for 3D directional detection for MIMAC
Authors:
J. P. Richer,
O. Bourrion,
G. Bosson,
O. Guillaudin,
F. Mayet,
D. Santos
Abstract:
A front end ASIC has been designed to equip the μTPC prototype developed for the MIMAC project, which requires 3D reconstruction of low energy particle tracks in order to perform directional detection of galactic Dark Matter. Each ASIC is able to monitor 64 strips of pixels and provides the "Time Over Threshold" information for each of those. These 64 digital informations, sampled at a rate of 50…
▽ More
A front end ASIC has been designed to equip the μTPC prototype developed for the MIMAC project, which requires 3D reconstruction of low energy particle tracks in order to perform directional detection of galactic Dark Matter. Each ASIC is able to monitor 64 strips of pixels and provides the "Time Over Threshold" information for each of those. These 64 digital informations, sampled at a rate of 50 MHz, can be transferred at 400MHz by eight LVDS serial links. Eight ASIC were validated on a 2x256 strips of pixels prototype.
△ Less
Submitted 10 November, 2011; v1 submitted 20 October, 2011;
originally announced October 2011.
-
Data acquisition electronics and reconstruction software for real time 3D track reconstruction within the MIMAC project
Authors:
O. Bourrion,
G. Bosson,
C. Grignon,
J. L. Bouly,
J. P. Richer,
O. Guillaudin,
F. Mayet,
J. Billard,
D. Santos
Abstract:
Directional detection of non-baryonic Dark Matter requires 3D reconstruction of low energy nuclear recoils tracks. A gaseous micro-TPC matrix, filled with either 3He, CF4 or C4H10 has been developed within the MIMAC project. A dedicated acquisition electronics and a real time track reconstruction software have been developed to monitor a 512 channel prototype. This autotriggered electronic uses em…
▽ More
Directional detection of non-baryonic Dark Matter requires 3D reconstruction of low energy nuclear recoils tracks. A gaseous micro-TPC matrix, filled with either 3He, CF4 or C4H10 has been developed within the MIMAC project. A dedicated acquisition electronics and a real time track reconstruction software have been developed to monitor a 512 channel prototype. This autotriggered electronic uses embedded processing to reduce the data transfer to its useful part only, i.e. decoded coordinates of hit tracks and corresponding energy measurements. An acquisition software with on-line monitoring and 3D track reconstruction is also presented.
△ Less
Submitted 2 November, 2011; v1 submitted 19 October, 2011;
originally announced October 2011.
-
Quenching factor measurement in low pressure gas detector for directional dark matter search
Authors:
O. Guillaudin,
J. Billard,
G. Bosson,
O. Bourrion,
T. Lamy,
F. Mayet,
D. Santos,
P. Sortais
Abstract:
There is considerable experimental effort dedicated to the directional detection of particle dark matter. Gaseous mu-TPC detectors present the privileged features of being able to reconstruct the track and the energy of the recoil nucleus following the interaction. A precise measurement of the recoil energy is a key point for the directional search strategy. Quenching has to be taken into account,…
▽ More
There is considerable experimental effort dedicated to the directional detection of particle dark matter. Gaseous mu-TPC detectors present the privileged features of being able to reconstruct the track and the energy of the recoil nucleus following the interaction. A precise measurement of the recoil energy is a key point for the directional search strategy. Quenching has to be taken into account, i.e. only a certain fraction of the recoil energy is deposited in the ionization channel. Measurements of the ionization quenching factor for different gas mixture at room temperature have been made with a dedicated ion beam facility at the LPSC of Grenoble.
△ Less
Submitted 10 October, 2011;
originally announced October 2011.
-
Dedicated front-end and readout electronics developments for real time 3D directional detection of dark matter with MIMAC
Authors:
O. Bourrion,
G. Bosson,
C. Grignon,
J. P. Richer,
O. Guillaudin,
F. Mayet,
J. Billard,
D. Santos
Abstract:
A complete dedicated electronics, from front-end to back-end, was developed to instrument a MIMAC prototype. A front end ASIC able to monitor 64 strips of pixels and to provide their individual "Time Over Threshold" information has been designed. An associated acquisition electronics and a real time track reconstruction software have been developed to monitor a 512 channel prototype. This auto-tri…
▽ More
A complete dedicated electronics, from front-end to back-end, was developed to instrument a MIMAC prototype. A front end ASIC able to monitor 64 strips of pixels and to provide their individual "Time Over Threshold" information has been designed. An associated acquisition electronics and a real time track reconstruction software have been developed to monitor a 512 channel prototype. This auto-triggered electronic uses embedded processing to reduce the data transfer to its useful part only, i.e. decoded coordinates of hit tracks and corresponding energy measurements. The electronic designs, acquisition software and the results obtained are presented.
△ Less
Submitted 19 September, 2011; v1 submitted 9 September, 2011;
originally announced September 2011.
-
Micromegas detector developments for MIMAC
Authors:
E. Ferrer-Ribas,
D. Attié,
D. Calvet,
P. Colas,
F. Druillole,
Y. Giomataris,
F. J. Iguaz,
J. P. Mols,
J. Pancin,
T. Papaevangelou,
J. Billard,
G. Bosson,
J. L. Bouly,
O. Bourrion,
Ch. Fourel,
C. Grignon,
O. Guillaudin,
F. Mayet,
J. P. Richer,
D. Santos,
C. Golabek,
L. Lebreton
Abstract:
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC. The recent Micromegas efforts towards building a large size detector will be described, in particular the characterization measurements of a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout plane. Track reconstruction with alpha particles will be shown.
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC. The recent Micromegas efforts towards building a large size detector will be described, in particular the characterization measurements of a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout plane. Track reconstruction with alpha particles will be shown.
△ Less
Submitted 12 September, 2011; v1 submitted 8 September, 2011;
originally announced September 2011.
-
Micromegas detector developments for Dark Matter directional detection with MIMAC
Authors:
F. J. Iguaz,
D. Attié,
D. Calvet,
P. Colas,
F. Druillole,
E. Ferrer-Ribas,
I. Giomataris,
J. P. Mols,
J. Pancin,
T. Papaevangelou,
J. Billard,
G. Bosson,
J. L. Bouly,
O. Bourrion,
Ch. Fourel,
C. Grignon,
O. Guillaudin,
F. Mayet,
J. P. Richer,
D. Santos,
C. Golabek,
L. Lebreton
Abstract:
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC using a high precision Micromegas readout plane. We will describe in detail the recent developments done with bulk Micromegas detectors as well as the characterisation measurements performed in an Argon(95%)-Isobutane(5%) mixture. Track measurements with alpha particles will be shown.
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC using a high precision Micromegas readout plane. We will describe in detail the recent developments done with bulk Micromegas detectors as well as the characterisation measurements performed in an Argon(95%)-Isobutane(5%) mixture. Track measurements with alpha particles will be shown.
△ Less
Submitted 10 May, 2011;
originally announced May 2011.
-
MIMAC : A micro-tpc matrix for directional detection of dark matter
Authors:
D. Santos,
J. Billard,
G. Bosson,
J. L. Bouly,
O. Bourrion,
Ch. Fourel,
C. Grignon,
O. Guillaudin,
F. Mayet,
J. P. Richer,
A. Delbart,
E. Ferrer,
I. Giomataris,
F. J. Iguaz,
J. P. Mols,
C. Golabek,
L. Lebreton
Abstract:
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with CF4 and CHF3. T…
▽ More
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with CF4 and CHF3. The first results on low energy nuclear recoils (H, F) obtained with a low mono-energetic neutron field are presented. The discovery potential of this search strategy is discussed and illustrated by a realistic case accessible to MIMAC.
△ Less
Submitted 16 February, 2011;
originally announced February 2011.
-
MIMAC : A micro-tpc matrix for directional detection of dark matter
Authors:
D. Santos,
J. Billard,
G. Bosson,
O. Bourrion,
C. Grignon,
O. Guillaudin,
F. Mayet,
J. P. Richer,
E. Ferrer,
I. Giomataris,
F. J. Iguaz,
J. P. Mols,
A. Allaoua,
C. Golabek,
L. Lebreton
Abstract:
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with 3He, CF4 and/or…
▽ More
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with 3He, CF4 and/or C4H10. The first results on low energy nuclear recoils (1H and 19F) obtained with a low mono-energetic neutron field are presented. The discovery potential of this search strategy is discussed and illustrated by a realistic case accessible to MIMAC.
△ Less
Submitted 6 December, 2010;
originally announced December 2010.
-
Directional detection of non-baryonic dark matter with MIMAC
Authors:
C. Grignon,
J. Billard,
G. Bosson,
O. Bourrion,
O. Guillaudin,
F. Mayet,
J. P. Richer,
D. Santos,
E. Ferrer,
I. Giomataris,
J. P. Mols
Abstract:
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating genuine WIMP events from background ones. However, carrying out such a strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed: it is based on a gaseous micro-TPC matrix,…
▽ More
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating genuine WIMP events from background ones. However, carrying out such a strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed: it is based on a gaseous micro-TPC matrix, filled with 3He, CF4 and/or C4H10. Firsts results of low energy nuclei recoils obtained with a low energy neutron field are presented.
△ Less
Submitted 17 September, 2010; v1 submitted 27 August, 2010;
originally announced August 2010.
-
Data acquisition electronics and reconstruction software for directional detection of Dark Matter with MIMAC
Authors:
O. Bourrion,
G. Bosson,
C. Grignon,
J. L. Bouly,
J. P. Richer,
O. Guillaudin,
F. Mayet,
D. Santos
Abstract:
Directional detection of galactic Dark Matter requires 3D reconstruction of low energy nuclear recoils tracks. A dedicated acquisition electronics with auto triggering feature and a real time track reconstruction software have been developed within the framework of the MIMAC project of detector. This auto-triggered acquisition electronic uses embedded processing to reduce data transfer to its usef…
▽ More
Directional detection of galactic Dark Matter requires 3D reconstruction of low energy nuclear recoils tracks. A dedicated acquisition electronics with auto triggering feature and a real time track reconstruction software have been developed within the framework of the MIMAC project of detector. This auto-triggered acquisition electronic uses embedded processing to reduce data transfer to its useful part only, i.e. decoded coordinates of hit tracks and corresponding energy measurements. An acquisition software with on-line monitoring and 3D track reconstruction is also presented.
△ Less
Submitted 7 June, 2010;
originally announced June 2010.
-
Directional detection of galactic Dark Matter
Authors:
F. Mayet,
J. Billard,
G. Bernard,
G. Bosson,
O. Bourrion,
C. Grignon,
O. Guillaudin,
C. Koumeir,
J. P. Richer,
D. Santos,
P. Colas,
E. Ferer,
I. Giomataris,
A. Allaoua,
L. Lebreton
Abstract:
Directional detection of galactic Dark Matter is a promising search strategy for discriminating geniune WIMP events from background ones. We present technical progress on gaseous detectors as well as recent phenomenological studies, allowing the design and construction of competitive experiments.
Directional detection of galactic Dark Matter is a promising search strategy for discriminating geniune WIMP events from background ones. We present technical progress on gaseous detectors as well as recent phenomenological studies, allowing the design and construction of competitive experiments.
△ Less
Submitted 18 January, 2010;
originally announced January 2010.
-
Development of a front end ASIC for Dark Matter directional detection with MIMAC
Authors:
J. P. Richer,
G. Bosson,
O. Bourrion,
C. Grignon,
O. Guillaudin,
F. Mayet,
D. Santos
Abstract:
A front end ASIC (BiCMOS-SiGe 0.35 \mum) has been developed within the framework of the MIMAC detector project, which aims at directional detection of non-baryonic Dark Matter. This search strategy requires 3D reconstruction of low energy (a few keV) tracks with a gaseous \muTPC. The development of this front end ASIC is a key point of the project, allowing the 3D track reconstruction. Each ASIC m…
▽ More
A front end ASIC (BiCMOS-SiGe 0.35 \mum) has been developed within the framework of the MIMAC detector project, which aims at directional detection of non-baryonic Dark Matter. This search strategy requires 3D reconstruction of low energy (a few keV) tracks with a gaseous \muTPC. The development of this front end ASIC is a key point of the project, allowing the 3D track reconstruction. Each ASIC monitors 16 strips of pixels with charge preamplifiers and their time over threshold is provided in real time by current discriminators via two serializing LVDS links working at 320 MHz. The charge is summed over the 16 strips and provided via a shaper. These specifications have been chosen in order to build an auto triggered electronics. An acquisition board and the related software were developed in order to validate this methodology on a prototype chamber. The prototype detector presents an anode where 2 x 96 strips of pixels are monitored.
△ Less
Submitted 13 April, 2010; v1 submitted 1 December, 2009;
originally announced December 2009.
-
A prototype of a directional detector for non-baryonic dark matter search: MIMAC (Micro-TPC Matrix of Chambers)
Authors:
C. Grignon,
G. Bernard,
J. Billard,
G. Bosson,
O. Bourrion,
O. Guillaudin,
C. Koumeir,
F. Mayet,
D. Santos,
P. Colas,
E. Ferrer,
I. Giomataris,
A. Allaoua,
L. Lebreton
Abstract:
We have developed a micro-tpc using a pixelized bulk micromegas coupled to dedicated acquisition electronics as a read-out allowing to reconstruct the three dimensional track of a few keV recoils. The prototype has been tested with the Amande facility at the IRSN-Cadarache providing monochromatic neutrons. The first results concerning discrimination of a few keV electrons and proton recoils are…
▽ More
We have developed a micro-tpc using a pixelized bulk micromegas coupled to dedicated acquisition electronics as a read-out allowing to reconstruct the three dimensional track of a few keV recoils. The prototype has been tested with the Amande facility at the IRSN-Cadarache providing monochromatic neutrons. The first results concerning discrimination of a few keV electrons and proton recoils are presented.
△ Less
Submitted 30 October, 2009; v1 submitted 3 September, 2009;
originally announced September 2009.
-
Dark matter directional detection with MIMAC
Authors:
C. Grignon,
J. Billard,
G. Bosson,
O. Bourrion,
O. Guillaudin,
C. Koumeir,
F. Mayet,
D. Santos,
P. Colas,
E. Ferrer,
I. Giomataris
Abstract:
MiMac is a project of micro-TPC matrix of gaseous (He3, CF4) chambers for direct detection of non-baryonic dark matter. Measurement of both track and ionization energy will allow the electron-recoil discrimination, while access to the directionnality of the tracks will open a unique way to distinguish a geniune WIMP signal from any background. First reconstructed tracks of 5.9 keV electrons are…
▽ More
MiMac is a project of micro-TPC matrix of gaseous (He3, CF4) chambers for direct detection of non-baryonic dark matter. Measurement of both track and ionization energy will allow the electron-recoil discrimination, while access to the directionnality of the tracks will open a unique way to distinguish a geniune WIMP signal from any background. First reconstructed tracks of 5.9 keV electrons are presented as a proof of concept.
△ Less
Submitted 29 May, 2009;
originally announced May 2009.