Skip to main content

Showing 1–35 of 35 results for author: Bosson, G

.
  1. arXiv:2105.05053  [pdf, other

    physics.ins-det physics.med-ph

    Performance of CVD diamond detectors for single ion beam-tagging applications in hadrontherapy monitoring

    Authors: Sébastien Curtoni, Marie-Laure Gallin-Martel, Sara Marcatili, Latifa Abbassi, Alexandre Bes, Germain Bosson, Johann Collot, Thierry Crozes, Denis Dauvergne, Wout De Nolf, Pierre Everaere, Laurent Gallin-Martel, Abderrahmane Ghimouz, Ferid Haddad, Christophe Hoarau, Jean-Yves Hostachy, Charbel Koumeir, Ana Lacoste, Vincent Métivier, John Morse, Jean-François Motte, Jean-François Muraz, Freddy Poirier, Fatah Ellah Rarbi, Olivier Rossetto , et al. (4 additional authors not shown)

    Abstract: In the context of online ion range verification in particle therapy, the CLaRyS collaboration is develo** Prompt-Gamma (PG) detection systems. The originality in the CLaRyS approach is to use a beam-tagging hodoscope in coincidence with the gamma detectors to provide both temporal and spatial information of the incoming ions. The ion range sensitivity of such PG detection systems could be improv… ▽ More

    Submitted 23 August, 2021; v1 submitted 11 May, 2021; originally announced May 2021.

    Comments: 15 pages, 9 figures

  2. arXiv:2102.10881  [pdf

    physics.ins-det nucl-ex

    RF pulse amplifier for CVD-diamond particle detectors

    Authors: C. Hoarau, G. Bosson, J. -L. Bouly, S. Curtoni, D. Dauvergne, P. Everaere, M. -L. Gallin-Martel, S. Marcatili, J. -F. Muraz, A. Portier, N. Rosuel

    Abstract: This article introduces a design of a Low Noise Amplifier (LNA), for the field of diamond particle detectors. This amplifier is described from simulation to measurements, which include pulses from α particles detection. In hadron therapy, with high-frequency pulsed particle beams, the diamond detector is a promising candidate for beam monitoring and time-stam**, with prerequisite of fast electro… ▽ More

    Submitted 22 February, 2021; originally announced February 2021.

    Comments: 8 pages, 13 figures, 1 tables. "has been accepted for publication in JINST."

    Report number: Technical Report JINST_014T_0920

  3. arXiv:1906.03878  [pdf

    physics.ins-det nucl-ex

    Fast neutron spectroscopy from 1 MeV up to 15 MeV with Mimac-FastN, a mobile and directional fast neutron spectrometer

    Authors: Nadine Sauzet, Daniel Santos, Olivier Guillaudin, Germain Bosson, Joël Bouvier, Thierry Descombes, Marc Marton, Jean-François Muraz

    Abstract: In the frame of direct dark matter search, the fast neutrons producing elastic collisions are the ultimate background. The MIMAC (MIcro-tpc MAtrix Chambers) project has developed a directional detector providing the directional signature to discriminate them based on 3D nuclear tracks reconstruction. The MIMAC team of the LPSC has adapted one MIMAC chamber as a portable fast neutron spectrometer,… ▽ More

    Submitted 12 March, 2020; v1 submitted 10 June, 2019; originally announced June 2019.

    Comments: 34 pages, 32 figures

  4. arXiv:1804.09052  [pdf, other

    physics.ins-det hep-ex

    The STEREO Experiment

    Authors: N. Allemandou, H. Almazán, P. del Amo Sanchez, L. Bernard, C. Bernard, A. Blanchet, A. Bonhomme, G. Bosson, O. Bourrion, J. Bouvier, C. Buck, V. Caillot, M. Chala, P. Champion, P. Charon, A. Collin, P. Contrepois, G. Coulloux, B. Desbrières, G. Deleglise, W. El Kanawati, J. Favier, S. Fuard, I. Gomes Monteiro, B. Gramlich , et al. (40 additional authors not shown)

    Abstract: The STEREO experiment is a very short baseline reactor antineutrino experiment aiming at testing the hypothesis of light sterile neutrinos as an explanation of the deficit of the observed neutrino interaction rate with respect to the predicted rate, known as the Reactor Antineutrino Anomaly. The detector center is located 10 m away from the compact, highly $^{235}$U enriched core of the research n… ▽ More

    Submitted 14 August, 2018; v1 submitted 24 April, 2018; originally announced April 2018.

    Comments: 32 pages, 17 figures

    Journal ref: Journal of Instrumentation 13, 07 (2018): P07009

  5. The NIKA2 instrument at 30-m IRAM telescope: performance and results

    Authors: A. Catalano, R. Adam, P. A. R. Ade, P., André, H. Aussel, A. Beelen, A. Benoit, A. Bideaud, N. Billot, O. Bourrion, M. Calvo, B. Comis, M. De Petris, F. -X. Désert, S. Doyle, E. F. C. Driessen, J. Goupy, C. Kramer, G. Lagache, S. Leclercq, J. -F. Lestrade, J. F. Macìas-Pérez, P. Mauskopf, F. Mayet , et al. (62 additional authors not shown)

    Abstract: The New IRAM KID Arrays 2 (NIKA2) consortium has just finished installing and commissioning a millimetre camera on the IRAM 30 m telescope. It is a dual-band camera operating with three frequency multiplexed kilo-pixels arrays of Lumped Element Kinetic Inductance Detectors (LEKID) cooled at 150 mK, designed to observe the intensity and polarisation of the sky at 260 and 150 GHz (1.15 and 2 mm). NI… ▽ More

    Submitted 4 February, 2018; v1 submitted 11 December, 2017; originally announced December 2017.

  6. arXiv:1610.02396  [pdf, other

    physics.ins-det astro-ph.CO astro-ph.IM hep-ex

    Readout technologies for directional WIMP Dark Matter detection

    Authors: J. B. R. Battat, I. G. Irastorza, A. Aleksandrov, M. Ali Guler, T. Asada, E. Baracchini, J. Billard, G. Bosson, O. Bourrion, J. Bouvier, A. Buonaura, K. Burdge, S. Cebrian, P. Colas, L. Consiglio, T. Dafni, N. D'Ambrosio, C. Deaconu, G. De Lellis, T. Descombes, A. Di Crescenzo, N. Di Marco, G. Druitt, R. Eggleston, E. Ferrer-Ribas , et al. (68 additional authors not shown)

    Abstract: The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial… ▽ More

    Submitted 6 October, 2016; originally announced October 2016.

    Comments: 58 pages, 26 figures, accepted by Physics Reports

    Journal ref: Physics Reports 662 (2016) pp. 1-46

  7. arXiv:1606.08877  [pdf, ps, other

    physics.acc-ph hep-ex nucl-ex

    Production of highly-polarized positrons using polarized electrons at MeV energies

    Authors: D. Abbott, P. Adderley, A. Adeyemi, P. Aguilera, M. Ali, H. Areti, M. Baylac, J. Benesch, G. Bosson, B. Cade, A. Camsonne, L. S. Cardman, J. Clark, P. Cole, S. Covert, C. Cuevas, O. Dadoun, D. Dale, H. Dong, J. Dumas, E. Fanchini, T. Forest, E. Forman, A. Freyberger, E. Froidefond , et al. (40 additional authors not shown)

    Abstract: The Polarized Electrons for Polarized Positrons experiment at the injector of the Continuous Electron Beam Accelerator Facility has demonstrated for the first time the efficient transfer of polarization from electrons to positrons produced by the polarized bremsstrahlung radiation induced by a polarized electron beam in a high-$Z$ target. Positron polarization up to 82\% have been measured for an… ▽ More

    Submitted 28 June, 2016; originally announced June 2016.

    Comments: 5 pages, 4 figures

    Journal ref: Phys. Rev. Lett. 116 (2016) 214801

  8. arXiv:1602.01738  [pdf, other

    astro-ph.IM physics.ins-det

    MIMAC low energy electron-recoil discrimination measured with fast neutrons

    Authors: Q. Riffard, D. Santos, O. Guillaudin, G. Bosson, O. Bourrion, J. Bouvier, T. Descombes, J. -F. Muraz, L. Lebreton, D. Maire, P. Colas, I. Giomataris, J. Busto, D. Fouchez, J. Brunner, C. Tao

    Abstract: MIMAC (MIcro-TPC MAtrix of Chambers) is a directional WIMP Dark Matter detector project. Direct dark matter experiments need a high level of electron/recoil discrimination to search for nuclear recoils produced by WIMP-nucleus elastic scattering. In this paper, we proposed an original method for electron event rejection based on a multivariate analysis applied to experimental data acquired using m… ▽ More

    Submitted 4 July, 2016; v1 submitted 4 February, 2016; originally announced February 2016.

    Comments: 27 pages, 20 figures

  9. arXiv:1602.01288  [pdf, other

    astro-ph.IM physics.ins-det

    NIKEL_AMC: Readout electronics for the NIKA2 experiment

    Authors: O. Bourrion, A. Benoit, J. L. Bouly, J. Bouvier, G. Bosson, M. Calvo, A. Catalano, J. Goupy, C. Li, J. F. Macías-Pérez, A. Monfardini, D. Tourres, N. Ponchant, C. Vescovi

    Abstract: The New Iram Kid Arrays-2 (NIKA2) instrument has recently been installed at the IRAM 30 m telescope. NIKA2 is a state-of-art instrument dedicated to mm-wave astronomy using microwave kinetic inductance detectors (KID) as sensors. The three arrays installed in the camera, two at 1.25 mm and one at 2.05 mm, feature a total of 3300 KIDs. To instrument these large array of detectors, a specifically de… ▽ More

    Submitted 25 October, 2016; v1 submitted 3 February, 2016; originally announced February 2016.

    Comments: 21 pages; 16 figures

    Journal ref: JINST 11 P11001 (2016)

  10. Trigger and readout electronics for the STEREO experiment

    Authors: O. Bourrion, J. L. Bouly, J. Bouvier, G. Bosson, V. Helaine, J. Lamblin, C. Li, F. Montanet, J. S. Real, T. Salagnac, N. Ponchant, A. Stutz, D. Tourres, C. Vescovi, S. Zsoldos

    Abstract: The STEREO experiment will search for a sterile neutrino by measuring the anti-neutrino energy spectrum as a function of the distance from the source, the ILL nuclear reactor. A dedicated electronic system, hosted in a single microTCA crate, was designed for this experiment. It performs triggering in two stages with various selectable conditions, processing and readout via UDP/IPBUS of 68 photomul… ▽ More

    Submitted 18 January, 2016; v1 submitted 28 October, 2015; originally announced October 2015.

    Comments: Topical Workshop on Electronics for Particle Physics (TWEPP) 2015, Lisboa. 9 pages, 9 figures

    Journal ref: JINST 11 C02078 (2016)

  11. arXiv:1504.05865  [pdf, other

    astro-ph.IM nucl-ex physics.ins-det

    First detection of tracks of radon progeny recoils by MIMAC

    Authors: Q. Riffard, D. Santos, G. Bosson, O. Bourrion, T. Descombes, C. Fourel, O. Guillaudin, J. -F. Muraz, P. Colas, E. Ferrer-Ribas, I. Giomataris, J. Busto, D. Fouchez, C. Tao, L. Lebreton, D. Maire

    Abstract: The MIMAC experiment is a $μ$-TPC matrix project for directional dark matter search. Directional detection is a strategy based on the measurement of the WIMP flux anisotropy due to the solar system motion with respect to the dark matter halo. The main purpose of MIMAC project is the measurement of the energy and the direction of nuclear recoils in 3D produced by elastic scattering of WIMPs. Since… ▽ More

    Submitted 20 June, 2017; v1 submitted 22 April, 2015; originally announced April 2015.

    Comments: 11 pages, 12 figures, submitted to PRD

  12. arXiv:1405.0637  [pdf, other

    cs.DC

    Limiting Lamport Exposure to Distant Failures in Globally-Managed Distributed Systems

    Authors: Cristina Băsescu, Georgia Fragkouli, Enis Ceyhun Alp, Michael F. Nowlan, Jose M. Faleiro, Gaylor Bosson, Kelong Cong, Pierluca Borsò-Tan, Vero Estrada-Galiñanes, Bryan Ford

    Abstract: Globalized computing infrastructures offer the convenience and elasticity of globally managed objects and services, but lack the resilience to distant failures that localized infrastructures such as private clouds provide. Providing both global management and resilience to distant failures, however, poses a fundamental problem for configuration services: How to discover a possibly migratory, stron… ▽ More

    Submitted 15 July, 2022; v1 submitted 3 May, 2014; originally announced May 2014.

    Comments: 14 pages, 9 figures, 5 algorithms, 1 table

  13. arXiv:1401.1009  [pdf, ps, other

    astro-ph.IM physics.ins-det

    Measurement of the electron drift velocity for directional dark matter detectors

    Authors: F. Mayet, J. Billard, G. Bosson, O. Bourrion, O. Guillaudin, J. Lamblin, J. P. Richer, Q. Riffard, D. Santos, F. J. Iguaz, L. Lebreton, D. Maire

    Abstract: Three-dimensional track reconstruction is a key issue for directional Dark Matter detection. It requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by sim… ▽ More

    Submitted 6 January, 2014; originally announced January 2014.

    Comments: Proceedings of the 4th international conference on Directional Detection of Dark Matter (CYGNUS 2013), 10-12 June 2013, Toyama, Japan

    Report number: in2p3-00845411

    Journal ref: J. Phys. Conf. Ser. 469 (2013) 012006

  14. arXiv:1311.0616  [pdf, other

    physics.ins-det astro-ph.CO

    MIMAC: MIcro-tpc MAtrix of Chambers for dark matter directional detection

    Authors: D. Santos, G. Bosson, J. L. Bouly, O. Bourrion, Ch. Fourel, O. Guillaudin, J. Lamblin, F. Mayet, J. F. Muraz, J. P. Richer, Q. Riffard, L. Lebreton, D. Maire, J. Busto, J. Brunner, D. Fouchez

    Abstract: Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from neutrons, the ultimate background for dark matter direct detection. This strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last ye… ▽ More

    Submitted 4 November, 2013; originally announced November 2013.

    Comments: Proceedings of the 4th International Conference on Directional Dark Matter Detection CYGNUS2013, held in Toyoma (Japan), June 2013

  15. arXiv:1310.6837  [pdf

    physics.ins-det nucl-ex

    Measurement of a 127 keV Neutron Field with a micro-TPC Spectrometer

    Authors: D. Maire, J. Billard, G. Bosson, O. Bourrion, O. Guillaudin, J. Lamblin, L. Lebreton, F. Mayet, J. Médard, J. F. Muraz, M. Petit, J. P. Richer, Q. Riffard, D. Santos

    Abstract: In order to measure the energy of neutron fields, with energy ranging from 8 keV to 1 MeV, a new primary standard is being developed at the IRSN (Institute for Radioprotection and Nuclear Safety). This project, micro-TPC (Micro Time Projection Chamber), carried out in collaboration with the LPSC (Laboratoire de Physique Subatomique et de Cosmologie), is based on the nuclear recoil detector princip… ▽ More

    Submitted 7 January, 2014; v1 submitted 25 October, 2013; originally announced October 2013.

    Comments: 7 pages. Submitted in IEEE TNS/ Special Issue ANIMMA 2013

  16. arXiv:1310.5923  [pdf

    physics.ins-det nucl-ex

    Development of a microtpc detector as a standard instrument for low energy neutron field characterization

    Authors: D. Maire, J. Billard, G. Bosson, O. Bourrion, O. Guillaudin, J. Lamblin, L. Lebreton, F. Mayet, J. Médard, J-F. Muraz, J-P. Richer, Q. Riffard, D. Santos

    Abstract: In order to measure energy and fluence of neutron fields, with energy ranging from 8 keV to 1 MeV, a new primary standard is being developed at the IRSN (Institute for Radioprotection and Nuclear Safety). This project, micro-TPC (Micro Time Projection Chamber), carried out in collaboration with the LPSC, is based on the nucleus recoil detector principle. The measurement strategy requires track rec… ▽ More

    Submitted 22 October, 2013; originally announced October 2013.

    Comments: Neudos12 symposium proceeding. 4 pages

    Journal ref: Radiat. Prot. Dosimetry 161 (2014) 245

  17. arXiv:1306.4173  [pdf, other

    astro-ph.IM astro-ph.CO physics.ins-det

    Dark Matter directional detection with MIMAC

    Authors: Q. Riffard, J. Billard, G. Bosson, O. Bourrion, O. Guillaudin, J. Lamblin, F. Mayet, J. -F. Muraz, J. -P. Richer, D. Santos, L. Lebreton, D. Maire, J. Busto, J. Brunner, D. Fouchez

    Abstract: Directional detection is a promising direct Dark Matter (DM) search strategy. The angular distribution of the nuclear recoil tracks from WIMP events should present an anisotropy in galactic coordinates. This strategy requires both a measurement of the recoil energy with a threshold of about 5 keV and 3D recoil tracks down to few millimeters. The MIMAC project, based on a \textmu-TPC matrix, with… ▽ More

    Submitted 18 June, 2013; originally announced June 2013.

    Comments: Proceedings of the 48th Rencontres de Moriond: Very High Energy Phenomena in the Universe, 9-16 March 2013, La Thuile, Italy

    Report number: LPSC13144

  18. arXiv:1305.2360  [pdf, ps, other

    astro-ph.IM physics.ins-det

    In situ measurement of the electron drift velocity for upcoming directional Dark Matter detectors

    Authors: J. Billard, F. Mayet, G. Bosson, O. Bourrion, O. Guillaudin, J. Lamblin, J. P. Richer, Q. Riffard, D. Santos, F. J. Iguaz, L. Lebreton, D. Maire

    Abstract: Three-dimensional track reconstruction is a key issue for directional Dark Matter detection and it requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by… ▽ More

    Submitted 28 January, 2014; v1 submitted 10 May, 2013; originally announced May 2013.

    Comments: 19 pages, 14 figures. Minor corrections, matches published version in JINST

    Journal ref: JINST 9 (2014) P01013

  19. arXiv:1304.2255  [pdf, other

    physics.ins-det astro-ph.CO

    MIMAC: A micro-tpc matrix for dark matter directional detection

    Authors: D. Santos, J. Billard, G. Bosson, J. L. Bouly, O. Bourrion, C. Fourel, O. Guillaudin, J. Lamblin, J. F. Muraz, F. Mayet, J. P. Richer, Q. Riffard, E. Ferrer, I. Giomataris, F. J. Iguaz, L. Lebreton, D. Maire

    Abstract: The dark matter directional detection opens a new field in cosmology bringing the possibility to build a map of nuclear recoils that would be able to explore the galactic dark matter halo giving access to a particle characterization of such matter and the shape of the halo. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based o… ▽ More

    Submitted 8 April, 2013; originally announced April 2013.

    Comments: Proceedings of the 6th Symposium on Large TPCs for low energy rare event detection, Paris, December 2012

  20. A μ-TPC detector for the characterization of low energy neutron fields

    Authors: C. Golabek, J. Billard, A. Allaoua, G. Bosson, O. Bourrion, C. Grignon, O. Guillaudin, L. Lebreton, F. Mayet, M. Petit, J. -P. Richer, D. Santos

    Abstract: The AMANDE facility produces monoenergetic neutron fields from 2 keV to 20 MeV for metrological purposes. To be considered as a reference facility, fluence and energy distributions of neutron fields have to be determined by primary measurement standards. For this purpose, a micro Time Projection Chamber is being developed to be dedicated to measure neutron fields with energy ranging from 8 keV up… ▽ More

    Submitted 12 March, 2012; originally announced March 2012.

    Journal ref: Nucl. Instrum. Meth. A678 (2012) 33-38

  21. arXiv:1111.1566  [pdf, ps, other

    astro-ph.IM astro-ph.CO

    MIMAC: A micro-tpc matrix project for directional detection of dark matter

    Authors: D. Santos, J. Billard, G. Bosson, J. L. Bouly, O. Bourrion, Ch. Fourel, O. Guillaudin, F. Mayet, J. P. Richer, A. Delbart, E. Ferrer, I. Giomataris, F. J. Iguaz, J. P. Mols, C. Golabek, L. Lebreton

    Abstract: Directional detection of non-baryonic DarkMatter is a promising search strategy for discriminating WIMP events from background ones. This strategy requires both a measurement of the recoil energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC project, based on a micro-TPC matrix, filled with CF4 and CHF3 is being developed. The first results of a chamber prototype of… ▽ More

    Submitted 7 November, 2011; originally announced November 2011.

    Comments: Proceedings of the 3rd International Conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois- France- June 2011

  22. Development and validation of a 64 channel front end ASIC for 3D directional detection for MIMAC

    Authors: J. P. Richer, O. Bourrion, G. Bosson, O. Guillaudin, F. Mayet, D. Santos

    Abstract: A front end ASIC has been designed to equip the μTPC prototype developed for the MIMAC project, which requires 3D reconstruction of low energy particle tracks in order to perform directional detection of galactic Dark Matter. Each ASIC is able to monitor 64 strips of pixels and provides the "Time Over Threshold" information for each of those. These 64 digital informations, sampled at a rate of 50… ▽ More

    Submitted 10 November, 2011; v1 submitted 20 October, 2011; originally announced October 2011.

    Comments: proceedings of TWEPP-11, Vienna, Austria, 26-30 September 2011

    Journal ref: 2011 JINST 6 C11016

  23. Data acquisition electronics and reconstruction software for real time 3D track reconstruction within the MIMAC project

    Authors: O. Bourrion, G. Bosson, C. Grignon, J. L. Bouly, J. P. Richer, O. Guillaudin, F. Mayet, J. Billard, D. Santos

    Abstract: Directional detection of non-baryonic Dark Matter requires 3D reconstruction of low energy nuclear recoils tracks. A gaseous micro-TPC matrix, filled with either 3He, CF4 or C4H10 has been developed within the MIMAC project. A dedicated acquisition electronics and a real time track reconstruction software have been developed to monitor a 512 channel prototype. This autotriggered electronic uses em… ▽ More

    Submitted 2 November, 2011; v1 submitted 19 October, 2011; originally announced October 2011.

    Comments: Proceedings of TWEPP-11, Vienna, Austria, 26-30 September 2011

    Journal ref: 2011 JINST 6 C11003

  24. arXiv:1110.2042  [pdf, ps, other

    physics.ins-det

    Quenching factor measurement in low pressure gas detector for directional dark matter search

    Authors: O. Guillaudin, J. Billard, G. Bosson, O. Bourrion, T. Lamy, F. Mayet, D. Santos, P. Sortais

    Abstract: There is considerable experimental effort dedicated to the directional detection of particle dark matter. Gaseous mu-TPC detectors present the privileged features of being able to reconstruct the track and the energy of the recoil nucleus following the interaction. A precise measurement of the recoil energy is a key point for the directional search strategy. Quenching has to be taken into account,… ▽ More

    Submitted 10 October, 2011; originally announced October 2011.

    Comments: Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011

    Journal ref: EAS Publications Series 53 (2012) 119-127

  25. Dedicated front-end and readout electronics developments for real time 3D directional detection of dark matter with MIMAC

    Authors: O. Bourrion, G. Bosson, C. Grignon, J. P. Richer, O. Guillaudin, F. Mayet, J. Billard, D. Santos

    Abstract: A complete dedicated electronics, from front-end to back-end, was developed to instrument a MIMAC prototype. A front end ASIC able to monitor 64 strips of pixels and to provide their individual "Time Over Threshold" information has been designed. An associated acquisition electronics and a real time track reconstruction software have been developed to monitor a 512 channel prototype. This auto-tri… ▽ More

    Submitted 19 September, 2011; v1 submitted 9 September, 2011; originally announced September 2011.

    Comments: Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011

    Journal ref: EAS Publication Series 53 (2012) pp 129 - 136

  26. arXiv:1109.1675  [pdf, other

    physics.ins-det astro-ph.IM

    Micromegas detector developments for MIMAC

    Authors: E. Ferrer-Ribas, D. Attié, D. Calvet, P. Colas, F. Druillole, Y. Giomataris, F. J. Iguaz, J. P. Mols, J. Pancin, T. Papaevangelou, J. Billard, G. Bosson, J. L. Bouly, O. Bourrion, Ch. Fourel, C. Grignon, O. Guillaudin, F. Mayet, J. P. Richer, D. Santos, C. Golabek, L. Lebreton

    Abstract: The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC. The recent Micromegas efforts towards building a large size detector will be described, in particular the characterization measurements of a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout plane. Track reconstruction with alpha particles will be shown.

    Submitted 12 September, 2011; v1 submitted 8 September, 2011; originally announced September 2011.

    Comments: 8 pages, 7 figures Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011; corrections on author affiliations

  27. Micromegas detector developments for Dark Matter directional detection with MIMAC

    Authors: F. J. Iguaz, D. Attié, D. Calvet, P. Colas, F. Druillole, E. Ferrer-Ribas, I. Giomataris, J. P. Mols, J. Pancin, T. Papaevangelou, J. Billard, G. Bosson, J. L. Bouly, O. Bourrion, Ch. Fourel, C. Grignon, O. Guillaudin, F. Mayet, J. P. Richer, D. Santos, C. Golabek, L. Lebreton

    Abstract: The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC using a high precision Micromegas readout plane. We will describe in detail the recent developments done with bulk Micromegas detectors as well as the characterisation measurements performed in an Argon(95%)-Isobutane(5%) mixture. Track measurements with alpha particles will be shown.

    Submitted 10 May, 2011; originally announced May 2011.

    Comments: 12 pages, 12 figures

    Journal ref: JINST 6:P07002,2011

  28. MIMAC : A micro-tpc matrix for directional detection of dark matter

    Authors: D. Santos, J. Billard, G. Bosson, J. L. Bouly, O. Bourrion, Ch. Fourel, C. Grignon, O. Guillaudin, F. Mayet, J. P. Richer, A. Delbart, E. Ferrer, I. Giomataris, F. J. Iguaz, J. P. Mols, C. Golabek, L. Lebreton

    Abstract: Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with CF4 and CHF3. T… ▽ More

    Submitted 16 February, 2011; originally announced February 2011.

    Comments: 6 pages, Proc. of the fifth international symposium on large TPCs for low energy rare event detection, Paris, France, Dec. 2010. To appear in Journal of Physics

    Report number: LPSC10223

    Journal ref: J.Phys.Conf.Ser. 309 (2011) 012014

  29. arXiv:1012.1166  [pdf, ps, other

    astro-ph.IM astro-ph.CO

    MIMAC : A micro-tpc matrix for directional detection of dark matter

    Authors: D. Santos, J. Billard, G. Bosson, O. Bourrion, C. Grignon, O. Guillaudin, F. Mayet, J. P. Richer, E. Ferrer, I. Giomataris, F. J. Iguaz, J. P. Mols, A. Allaoua, C. Golabek, L. Lebreton

    Abstract: Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with 3He, CF4 and/or… ▽ More

    Submitted 6 December, 2010; originally announced December 2010.

    Comments: Proceedings of Identification of Dark Matter 2010-IDM2010 conference

  30. arXiv:1008.4712  [pdf, ps, other

    astro-ph.IM

    Directional detection of non-baryonic dark matter with MIMAC

    Authors: C. Grignon, J. Billard, G. Bosson, O. Bourrion, O. Guillaudin, F. Mayet, J. P. Richer, D. Santos, E. Ferrer, I. Giomataris, J. P. Mols

    Abstract: Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating genuine WIMP events from background ones. However, carrying out such a strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed: it is based on a gaseous micro-TPC matrix,… ▽ More

    Submitted 17 September, 2010; v1 submitted 27 August, 2010; originally announced August 2010.

    Comments: 4 pages, proc. of the 22nd Rencontres de Blois: Particle Physics and Cosmology, 15-20 July 2010, Blois, France

  31. Data acquisition electronics and reconstruction software for directional detection of Dark Matter with MIMAC

    Authors: O. Bourrion, G. Bosson, C. Grignon, J. L. Bouly, J. P. Richer, O. Guillaudin, F. Mayet, D. Santos

    Abstract: Directional detection of galactic Dark Matter requires 3D reconstruction of low energy nuclear recoils tracks. A dedicated acquisition electronics with auto triggering feature and a real time track reconstruction software have been developed within the framework of the MIMAC project of detector. This auto-triggered acquisition electronic uses embedded processing to reduce data transfer to its usef… ▽ More

    Submitted 7 June, 2010; originally announced June 2010.

    Comments: 17 pages, 12 figures

    Journal ref: Nucl. Instrum. Meth. A662 (2010) 207

  32. arXiv:1001.2983  [pdf, ps, other

    astro-ph.CO astro-ph.IM

    Directional detection of galactic Dark Matter

    Authors: F. Mayet, J. Billard, G. Bernard, G. Bosson, O. Bourrion, C. Grignon, O. Guillaudin, C. Koumeir, J. P. Richer, D. Santos, P. Colas, E. Ferer, I. Giomataris, A. Allaoua, L. Lebreton

    Abstract: Directional detection of galactic Dark Matter is a promising search strategy for discriminating geniune WIMP events from background ones. We present technical progress on gaseous detectors as well as recent phenomenological studies, allowing the design and construction of competitive experiments.

    Submitted 18 January, 2010; originally announced January 2010.

    Comments: Proceedings of the 12th Marcel Grossmann Meeting on General Relativity (MG 12), Paris, France, 12-18 Jul 2009

  33. Development of a front end ASIC for Dark Matter directional detection with MIMAC

    Authors: J. P. Richer, G. Bosson, O. Bourrion, C. Grignon, O. Guillaudin, F. Mayet, D. Santos

    Abstract: A front end ASIC (BiCMOS-SiGe 0.35 \mum) has been developed within the framework of the MIMAC detector project, which aims at directional detection of non-baryonic Dark Matter. This search strategy requires 3D reconstruction of low energy (a few keV) tracks with a gaseous \muTPC. The development of this front end ASIC is a key point of the project, allowing the 3D track reconstruction. Each ASIC m… ▽ More

    Submitted 13 April, 2010; v1 submitted 1 December, 2009; originally announced December 2009.

    Comments: 12 pages, 10 figures

    Journal ref: Nucl. Instrum. Meth.A620:470-476, 2010

  34. arXiv:0909.0654  [pdf, ps, other

    astro-ph.IM astro-ph.CO

    A prototype of a directional detector for non-baryonic dark matter search: MIMAC (Micro-TPC Matrix of Chambers)

    Authors: C. Grignon, G. Bernard, J. Billard, G. Bosson, O. Bourrion, O. Guillaudin, C. Koumeir, F. Mayet, D. Santos, P. Colas, E. Ferrer, I. Giomataris, A. Allaoua, L. Lebreton

    Abstract: We have developed a micro-tpc using a pixelized bulk micromegas coupled to dedicated acquisition electronics as a read-out allowing to reconstruct the three dimensional track of a few keV recoils. The prototype has been tested with the Amande facility at the IRSN-Cadarache providing monochromatic neutrons. The first results concerning discrimination of a few keV electrons and proton recoils are… ▽ More

    Submitted 30 October, 2009; v1 submitted 3 September, 2009; originally announced September 2009.

    Comments: 5 pages, proc. of the 1st International Conference on Micro Pattern Gaseous Detectors MPGD 2009, 12-15 June 2009, Kolympari, Crete, Greece

    Journal ref: JINST 4:P11003,2009

  35. arXiv:0905.4800  [pdf, ps, other

    astro-ph.IM astro-ph.CO

    Dark matter directional detection with MIMAC

    Authors: C. Grignon, J. Billard, G. Bosson, O. Bourrion, O. Guillaudin, C. Koumeir, F. Mayet, D. Santos, P. Colas, E. Ferrer, I. Giomataris

    Abstract: MiMac is a project of micro-TPC matrix of gaseous (He3, CF4) chambers for direct detection of non-baryonic dark matter. Measurement of both track and ionization energy will allow the electron-recoil discrimination, while access to the directionnality of the tracks will open a unique way to distinguish a geniune WIMP signal from any background. First reconstructed tracks of 5.9 keV electrons are… ▽ More

    Submitted 29 May, 2009; originally announced May 2009.

    Comments: 4 pages, proc. of the 44th Rencontres De Moriond: Electroweak Interactions And Unified Theories, 7-14 Mar 2009, La Thuile, Italy