-
Hierarchical Event Descriptor library schema for EEG data annotation
Authors:
Tal Pal Attia,
Kay Robbins,
Sándor Beniczky,
Jorge Bosch-Bayard,
Arnaud Delorme,
Brian Nils Lundstrom,
Christine Rogers,
Stefan Rampp,
Pedro Valdes-Sosa,
Dung Truong,
Greg Worrell,
Scott Makeig,
Dora Hermes
Abstract:
Standardizing terminology to describe electrophysiological events can improve both clinical care and computational research. Sharing data enriched by such standardized terminology can support advances in neuroscientific data exploration, from single-subject to mega-analysis. Machine readability of electrophysiological event annotations is essential for performing such analyses efficiently across s…
▽ More
Standardizing terminology to describe electrophysiological events can improve both clinical care and computational research. Sharing data enriched by such standardized terminology can support advances in neuroscientific data exploration, from single-subject to mega-analysis. Machine readability of electrophysiological event annotations is essential for performing such analyses efficiently across software tools and packages. Hierarchical Event Descriptors (HED) provide a framework for describing events in neuroscience experiments. HED library schemas extend the standard HED schema vocabulary to include specialized vocabularies, such as standardized clinical terms for electrophysiological events. The Standardized Computer-based Organized Reporting of EEG (SCORE) defines terms for annotating EEG events, including artifacts. This study makes SCORE machine-readable by incorporating it into a HED library schema. We demonstrate the use of the HED-SCORE library schema to annotate events in example EEG data stored in Brain Imaging Data Structure (BIDS) format. Clinicians and researchers worldwide can now use the HED-SCORE library schema to annotate and then compute on electrophysiological data obtained from the human brain.
△ Less
Submitted 4 October, 2023;
originally announced October 2023.
-
Spectral homogeneity cross frequencies can be a quality metric for the large-scale resting EEG preprocessing
Authors:
Shiang Hu,
Jie Ruan,
Nicolas Langer,
Jorge Bosch-Bayard,
Zhao Lv,
Dezhong Yao,
Pedro Antonio Valdes-Sosa
Abstract:
The brain projects require the collection of massive electrophysiological data, aiming to the longitudinal, sectional, or populational neuroscience studies. Quality metrics automatically label the data after centralized preprocessing. However, although the waveforms-based metrics are partially useful, they may be unreliable by neglecting the spectral profiles. Here, we detected the phenomenon of p…
▽ More
The brain projects require the collection of massive electrophysiological data, aiming to the longitudinal, sectional, or populational neuroscience studies. Quality metrics automatically label the data after centralized preprocessing. However, although the waveforms-based metrics are partially useful, they may be unreliable by neglecting the spectral profiles. Here, we detected the phenomenon of parallel log spectra (PaLOS) that the scalp EEG power in the log scale were parallel to each other from 10% of 2549 HBN EEG. This phenomenon was reproduced in 8% of 412 PMDT EEG from 4 databases. We designed the PaLOS index (PaLOSi) to indicate this phenomenon by decomposing the cross-spectra at different frequencies into the common principal component spaces. We found that the PaLOS biophysically implied a prominently dominant dipole in the source space which was implausible for the resting EEG. And it may be practically resulted from excessive preprocessing. Compared with the 1966 normative EEG cross-spectra, the HBN and the PMDT EEG with PaLOS presented generally much higher electrode pairwise coherences and higher similarity of coherence-based network patterns, which went against the known frequency dependent characteristic of coherence networks. We suggest the PaLOSi should lay in the range of 0.4-0.7 for large resting EEG quality assurance.
△ Less
Submitted 4 December, 2023; v1 submitted 18 October, 2023;
originally announced October 2023.
-
Identification of oscillatory brain networks with Hidden Gaussian Graphical Spectral models of EEG/MEG
Authors:
Deirel Paz-Linares,
Eduardo Gonzalez-Moreira,
Ariosky Areces-Gonzalez,
Ying Wang,
Min Li,
Eduardo Martinez-Montes,
Jorge Bosch-Bayard,
Maria L. Bringas-Vega,
Mitchel J. Valdes-Sosa,
Pedro A. Valdes-Sosa
Abstract:
Identifying the functional networks underpinning indirectly observed processes poses an inverse problem for neurosciences or other fields. A solution of such inverse problems estimates as a first step the activity emerging within functional networks from EEG or MEG data. These EEG or MEG estimates are a direct reflect functional brain network activity with a temporal resolution that no other in vi…
▽ More
Identifying the functional networks underpinning indirectly observed processes poses an inverse problem for neurosciences or other fields. A solution of such inverse problems estimates as a first step the activity emerging within functional networks from EEG or MEG data. These EEG or MEG estimates are a direct reflect functional brain network activity with a temporal resolution that no other in vivo neuroimage may provide. A second step estimating functional connectivity from such activity pseudodata unveil the oscillatory brain networks that strongly correlate with all cognition and behavior. Simulations of such MEG or EEG inverse problem also reveal estimation errors of the functional connectivity determined by any of the state-of-the-art inverse solutions. We disclose a significant cause of estimation errors originating from misspecification of the functional network model incorporated into either inverse solution steps. We introduce the Bayesian identification of a Hidden Gaussian Graphical Spectral (HIGGS) model specifying such oscillatory brain networks model. In human EEG alpha rhythm simulations estimation errors measured as ROC performance do not surpass 2% in our HIGGS inverse solution and reach 20% in state-of-the-art methods. Macaque simultaneous EEG/ECoG recordings provide experimental confirmation for our inverse-solution with 1/3 more congruence according to Riemannian distances than state-of-the-art methods.
△ Less
Submitted 25 October, 2022; v1 submitted 2 October, 2018;
originally announced October 2018.
-
Caulking the Leakage Effect in MEEG Source Connectivity Analysis
Authors:
Eduardo Gonzalez-Moreira,
Deirel Paz-Linares,
Ariosky Areces-Gonzalez,
Rigel Wang,
Jorge Bosch-Bayard,
Maria Luisa Bringas-Vega,
Pedro A. Valdes-Sosa
Abstract:
Simplistic estimation of neural connectivity in MEEG sensor space is impossible due to volume conduction. The only viable alternative is to carry out connectivity estimation in source space. Among the neuroscience community this is claimed to be impossible or misleading due to Leakage: linear mixing of the reconstructed sources. To address this problematic we propose a novel solution method that c…
▽ More
Simplistic estimation of neural connectivity in MEEG sensor space is impossible due to volume conduction. The only viable alternative is to carry out connectivity estimation in source space. Among the neuroscience community this is claimed to be impossible or misleading due to Leakage: linear mixing of the reconstructed sources. To address this problematic we propose a novel solution method that caulks the Leakage in MEEG source activity and connectivity estimates: BC-VARETA. It is based on a joint estimation of source activity and connectivity in the frequency domain representation of MEEG time series. To achieve this, we go beyond current methods that assume a fixed gaussian graphical model for source connectivity. In contrast we estimate this graphical model in a Bayesian framework by placing priors on it, which allows for highly optimized computations of the connectivity, via a new procedure based on the local quadratic approximation under quite general prior models. A further contribution of this paper is the rigorous definition of leakage via the Spatial Dispersion Measure and Earth Movers Distance based on the geodesic distances over the cortical manifold. Both measures are extended for the first time to quantify Connectivity Leakage by defining them on the cartesian product of cortical manifolds. Using these measures, we show that BC-VARETA outperforms most state of the art inverse solvers by several orders of magnitude.
△ Less
Submitted 1 December, 2019; v1 submitted 28 September, 2018;
originally announced October 2018.
-
Innovations orthogonalization: a solution to the major pitfalls of EEG/MEG "leakage correction"
Authors:
Roberto D. Pascual-Marqui,
Rolando J. Biscay,
Jorge Bosch-Bayard,
Pascal Faber,
Toshihiko Kinoshita,
Kieko Kochi,
Patricia Milz,
Keiichiro Nishida,
Masafumi Yoshimura
Abstract:
The problem of interest here is the study of brain functional and effective connectivity based on non-invasive EEG-MEG inverse solution time series. These signals generally have low spatial resolution, such that an estimated signal at any one site is an instantaneous linear mixture of the true, actual, unobserved signals across all cortical sites. False connectivity can result from analysis of the…
▽ More
The problem of interest here is the study of brain functional and effective connectivity based on non-invasive EEG-MEG inverse solution time series. These signals generally have low spatial resolution, such that an estimated signal at any one site is an instantaneous linear mixture of the true, actual, unobserved signals across all cortical sites. False connectivity can result from analysis of these low-resolution signals. Recent efforts toward "unmixing" have been developed, under the name of "leakage correction". One recent noteworthy approach is that by Colclough et al (2015 NeuroImage, 117:439-448), which forces the inverse solution signals to have zero cross-correlation at lag zero. One goal is to show that Colclough's method produces false human connectomes under very broad conditions. The second major goal is to develop a new solution, that appropriately "unmixes" the inverse solution signals, based on innovations orthogonalization. The new method first fits a multivariate autoregression to the inverse solution signals, giving the mixed innovations. Second, the mixed innovations are orthogonalized. Third, the mixed and orthogonalized innovations allow the estimation of the "unmixing" matrix, which is then finally used to "unmix" the inverse solution signals. It is shown that under very broad conditions, the new method produces proper human connectomes, even when the signals are not generated by an autoregressive model.
△ Less
Submitted 23 August, 2017; v1 submitted 20 August, 2017;
originally announced August 2017.
-
Isolated effective coherence (iCoh): causal information flow excluding indirect paths
Authors:
RD Pascual-Marqui,
RJ Biscay,
J Bosch-Bayard,
D Lehmann,
K Kochi,
N Yamada,
T Kinoshita,
N Sadato
Abstract:
A problem of great interest in real world systems, where multiple time series measurements are available, is the estimation of the intra-system causal relations. For instance, electric cortical signals are used for studying functional connectivity between brain areas, their directionality, the direct or indirect nature of the connections, and the spectral characteristics (e.g. which oscillations a…
▽ More
A problem of great interest in real world systems, where multiple time series measurements are available, is the estimation of the intra-system causal relations. For instance, electric cortical signals are used for studying functional connectivity between brain areas, their directionality, the direct or indirect nature of the connections, and the spectral characteristics (e.g. which oscillations are preferentially transmitted). The earliest spectral measure of causality was Akaike's (1968) seminal work on the noise contribution ratio, reflecting direct and indirect connections. Later, a major breakthrough was the partial directed coherence of Baccala and Sameshima (2001) for direct connections. The simple aim of this study consists of two parts: (1) To expose a major problem with the partial directed coherence, where it is shown that it is affected by irrelevant connections to such an extent that it can misrepresent the frequency response, thus defeating the main purpose for which the measure was developed, and (2) To provide a solution to this problem, namely the "isolated effective coherence", which consists of estimating the partial coherence under a multivariate auto-regressive model, followed by setting all irrelevant associations to zero, other than the particular directional association of interest. Simple, realistic, toy examples illustrate the severity of the problem with the partial directed coherence, and the solution achieved by the isolated effective coherence. For the sake of reproducible research, the software code implementing the methods discussed here (using lazarus free-pascal "www.lazarus.freepascal.org"), including the test data as text files, are freely available at: https://sites.google.com/site/pascualmarqui/home/icoh-isolated-effective-coherence
△ Less
Submitted 12 May, 2014; v1 submitted 19 February, 2014;
originally announced February 2014.
-
Cortical current source connectivity by means of partial coherence fields
Authors:
Roberto D. Pascual-Marqui,
Rolando J. Biscay,
Pedro A. Valdes-Sosa,
Jorge Bosch-Bayard,
Jorge J. Riera-Diaz
Abstract:
An important field of research in functional neuroimaging is the discovery of integrated, distributed brain systems and networks, whose different regions need to work in unison for normal functioning.
The EEG is a non-invasive technique that can provide information for massive connectivity analyses. Cortical signals of time varying electric neuronal activity can be estimated from the EEG. Althou…
▽ More
An important field of research in functional neuroimaging is the discovery of integrated, distributed brain systems and networks, whose different regions need to work in unison for normal functioning.
The EEG is a non-invasive technique that can provide information for massive connectivity analyses. Cortical signals of time varying electric neuronal activity can be estimated from the EEG. Although such techniques have very high time resolution, two cortical signals even at distant locations will appear to be highly similar due to the low spatial resolution nature of the EEG.
In this study a method for eliminating the effect of common sources due to low spatial resolution is presented. It is based on an efficient estimation of the whole-cortex partial coherence matrix. Using as a starting point any linear EEG tomography that satisfies the EEG forward equation, it is shown that the generalized partial coherences for the cortical grey matter current density time series are invariant to the selected tomography. It is empirically shown with simulation experiments that the generalized partial coherences have higher spatial resolution than the classical coherences. The results demonstrate that with as little as 19 electrodes, lag-connected brain regions can often be missed and misplaced even with lagged coherence measures, while the new method detects and localizes correctly the connected regions using the lagged partial coherences.
△ Less
Submitted 1 August, 2011;
originally announced August 2011.