-
Mid-Infrared Ring Interband Cascade Laser: Operation at the Standard Quantum Limit
Authors:
Georg Marschick,
Jacopo Pelini,
Tecla Gabbrielli,
Francesco Cappelli,
Robert Weih,
Hedwig Knötig,
Johannes Koeth,
Sven Höfling,
Paolo De Natale,
Gottfried Strasser,
Simone Borri,
Borislav Hinkov
Abstract:
Many precision applications in the mid-infrared spectral range have strong constraints based on quantum effects that are expressed in particular noise characteristics. They limit, e.g., sensitivity and resolution of mid-infrared imaging and spectroscopic systems as well as the bit-error rate in optical free-space communication. Interband cascade lasers (ICLs) are a class of mid-infrared laser expl…
▽ More
Many precision applications in the mid-infrared spectral range have strong constraints based on quantum effects that are expressed in particular noise characteristics. They limit, e.g., sensitivity and resolution of mid-infrared imaging and spectroscopic systems as well as the bit-error rate in optical free-space communication. Interband cascade lasers (ICLs) are a class of mid-infrared laser exploiting interband transitions in type-II band alignment geometry. They are currently gaining significant importance for mid-infrared applications from <3 μm to >6 μm wavelength, enabled by novel types of high-performance ICLs such as ring-cavity devices. Their noise-behavior is an important feature that still needs to be thoroughly analyzed, including its potential reduction with respect to the shot noise limit. In this work, we provide a comprehensive characterization of λ = 3.8 μm-emitting, continuous-wave ring-ICLs operating at room temperature. It is based on an in-depth study of their main physical intensity noise features, such as their bias-dependent intensity noise power spectral density (INPSD) and relative intensity noise (RIN). We obtain shot-noise-limited statistics for Fourier frequencies above 100 kHz. This is an important result for precision applications, e.g. interferometry or advanced spectroscopy, which benefit from exploiting the advantage of using such a shot-noise limited source, enhancing the setup sensitivity. Moreover, it is an important feature for novel quantum optics schemes including testing specific light states below the shot noise level, such as squeezed states.
△ Less
Submitted 20 June, 2023;
originally announced June 2023.
-
Characterization of noise regimes in Mid-IR free-space optical communication based on quantum cascade lasers
Authors:
Marco Seminara,
Tecla Gabbrielli,
Nicola Corrias,
Simone Borri,
Luigi Consolino,
Marco Meucci,
Paolo De Natale,
Francesco Cappelli,
Jacopo Catani
Abstract:
The recent development of Quantum Cascade Lasers (QCLs) represents one of the biggest opportunities for the deployment of a new class of Free Space Optical (FSO) communication systems working in the mid-infrared (Mid-IR) wavelength range. As compared to more common FSO systems exploiting the telecom range, the larger wavelength employed in Mid-IR systems delivers exceptional benefits in case of ad…
▽ More
The recent development of Quantum Cascade Lasers (QCLs) represents one of the biggest opportunities for the deployment of a new class of Free Space Optical (FSO) communication systems working in the mid-infrared (Mid-IR) wavelength range. As compared to more common FSO systems exploiting the telecom range, the larger wavelength employed in Mid-IR systems delivers exceptional benefits in case of adverse atmospheric conditions, as the reduced scattering rate strongly suppresses detrimental effects on the FSO link length given by the presence of rain, dust, fog and haze. In this work, we use a novel FSO testbed operating at \SI{4.7}{\micro m}, to provide a detailed experimental analysis of noise regimes that could occur in realistic FSO Mid-IR systems based on QCLs. Our analysis reveals the existence of two distinct noise regions, corresponding to different realistic channel attenuation conditions, which are precisely controlled in our setup. To relate our results with real outdoor configurations, we combine experimental data with predictions of an atmospheric channel loss model, finding that error-free communication could be attained for effective distances up to 8~km in low visibility conditions of 1 km. Our analysis of noise regimes may have a key relevance for the development of novel, long-range FSO communication systems based on Mid-IR QCL sources
△ Less
Submitted 14 July, 2022;
originally announced August 2022.
-
Intensity correlations in quantum cascade laser harmonic frequency combs
Authors:
Tecla Gabbrielli,
Natalia Bruno,
Nicola Corrias,
Simone Borri,
Luigi Consolino,
Mathieu Bertrand,
Mehran Shahmohammadi,
Martin Franckie,
Mattias Beck,
Jerome Faist,
Alessandro Zavatta,
Francesco Cappelli,
Paolo De Natale
Abstract:
A novel study on harmonic frequency combs emitted by Quantum Cascade Lasers (QCLs) is here presented, demonstrating the presence of intensity correlations between twin modes characterising the emission spectra. These originate from a Four-Wave Mixing (FWM) process driven by the active medium's third-order non-linearity. The study of such correlations is essential for the engineering of a new gener…
▽ More
A novel study on harmonic frequency combs emitted by Quantum Cascade Lasers (QCLs) is here presented, demonstrating the presence of intensity correlations between twin modes characterising the emission spectra. These originate from a Four-Wave Mixing (FWM) process driven by the active medium's third-order non-linearity. The study of such correlations is essential for the engineering of a new generation of semiconductor devices with the potential of becoming integrated emitters of light with quantum properties, such as squeezing and entanglement. Starting from experimental results, the limits of state-of-the-art technology are discussed as well as the possible methodologies that could lead to the detection of non-classical phenomena, or alternatively improve the design of QCLs, in the compelling perspective of generating quantum correlations in mid-infrared light.
△ Less
Submitted 15 June, 2022;
originally announced June 2022.
-
Doubly resonant photoacoustic spectroscopy: ultra-high sensitivity meets ultra-wide dynamic range
Authors:
Zhen Wang,
Qiang Wang,
Hui Zhang,
Simone Borri,
Iacopo Galli,
Angelo Sampaolo,
Pietro Patimisco,
Vincenzo Luigi Spagnolo,
Paolo De Natale,
Wei Ren
Abstract:
Photoacoustic spectroscopy (PAS) based gas sensors with high sensitivity, wide dynamic range, low cost, and small footprint are desirable across a broad range of applications in energy, environment, safety, and public health. However, most works have focused on either acoustic resonator to enhance acoustic wave or optical resonator to enhance optical wave. Herein, we develop a gas sensor based on…
▽ More
Photoacoustic spectroscopy (PAS) based gas sensors with high sensitivity, wide dynamic range, low cost, and small footprint are desirable across a broad range of applications in energy, environment, safety, and public health. However, most works have focused on either acoustic resonator to enhance acoustic wave or optical resonator to enhance optical wave. Herein, we develop a gas sensor based on doubly resonant PAS in which the acoustic and optical waves are simultaneously enhanced using combined optical and acoustic resonators in a centimeter-long configuration. Not only the lower detection limit is enhanced by the double standing waves, but also the upper detection limit is expanded due to the short resonators. As an example, we developed a sensor by detecting acetylene (C2H2), achieving a noise equivalent absorption of 5.7*10-13 cm-1 and a dynamic range of eight orders. Compared to the state-of-the-art PAS gas sensors, the developed sensor increases the sensitivity by two orders of magnitude and extends the dynamic range by three orders of magnitude. Besides, a laser-cavity-molecule locking strategy is proposed to provide additional flexibility of fast gas detection.
△ Less
Submitted 8 April, 2022;
originally announced April 2022.
-
Mid-infrared homodyne balanced detector for quantum light characterization
Authors:
Tecla Gabbrielli,
Francesco Cappelli,
Natalia Bruno,
Nicola Corrias,
Simone Borri,
Paolo De Natale,
Alessandro Zavatta
Abstract:
We present the characterization of a novel balanced homodyne detector operating in the mid-infrared. The challenging task of revealing non-classicality in mid-infrared light, e.~g. in quantum cascade lasers emission, requires a high-performance detection system. Through the intensity noise power spectral density analysis of the differential signal coming from the incident radiation, we show that o…
▽ More
We present the characterization of a novel balanced homodyne detector operating in the mid-infrared. The challenging task of revealing non-classicality in mid-infrared light, e.~g. in quantum cascade lasers emission, requires a high-performance detection system. Through the intensity noise power spectral density analysis of the differential signal coming from the incident radiation, we show that our setup is shot-noise limited. We discuss the experimental results with a view to possible applications to quantum technologies, such as free-space quantum communication.
△ Less
Submitted 16 March, 2021;
originally announced March 2021.
-
Measuring molecular frequencies in the 1--10 μm range at 11-digits accuracy
Authors:
G. Insero,
S. Borri,
D. Calonico,
P. Cancio Pastor,
C. Clivati,
D. D'Ambrosio,
P. De Natale,
M. Inguscio,
F. Levi,
G. Santambrogio
Abstract:
Mid infrared (MIR) photonics is a key region for molecular physics [1]. High-resolution spectroscopy in the 1--10 μm region, though, has never been fully tackled for the lack of widely-tunable and practical light sources. Indeed, all solutions proposed thus far suffer from at least one of three issues: they are feasible only in a narrow spectral range; the power available for spectroscopy is limit…
▽ More
Mid infrared (MIR) photonics is a key region for molecular physics [1]. High-resolution spectroscopy in the 1--10 μm region, though, has never been fully tackled for the lack of widely-tunable and practical light sources. Indeed, all solutions proposed thus far suffer from at least one of three issues: they are feasible only in a narrow spectral range; the power available for spectroscopy is limited; the frequency accuracy is poor. Here, we present a setup for high-resolution spectroscopy that can be applied in the whole 1--10 μm range by combining the power of quantum cascade lasers (QCLs) and the accuracy achievable by difference frequency generation using an OP-GaP crystal. The frequency is measured against a primary frequency standard using the Italian metrological fibre link network. We demonstrate the performance of the setup by measuring a vibrational transition in a highly-excited metastable state of CO around 6 μm with 11 digits of precision, four orders of magnitude better than the value available in the literature [2].
△ Less
Submitted 18 May, 2017; v1 submitted 31 March, 2017;
originally announced March 2017.
-
Laser spectroscopy of cold molecules
Authors:
Simone Borri,
Gabriele Santambrogio
Abstract:
This paper reviews the recent results in high-resolution spectroscopy on cold molecules. Laser spectroscopy of cold molecules addresses issues of symmetry violation, like in the search for the electric dipole moment of the electron and the studies on energy differences in enantiomers of chiral species; tries to improve the precision to which fundamental physical constants are known and tests for t…
▽ More
This paper reviews the recent results in high-resolution spectroscopy on cold molecules. Laser spectroscopy of cold molecules addresses issues of symmetry violation, like in the search for the electric dipole moment of the electron and the studies on energy differences in enantiomers of chiral species; tries to improve the precision to which fundamental physical constants are known and tests for their possible variation in time and space; tests quantum electrodynamics, and searches for a fifth force. Further, we briefly review the recent technological progresses in the fields of cold molecules and mid-infrared lasers, which are the tools that mainly set the limits for the resolution that is currently attainable in the measurements.
△ Less
Submitted 4 July, 2016; v1 submitted 17 June, 2016;
originally announced June 2016.
-
Observing the intrinsic linewidth of a quantum-cascade laser: beyond the Schawlow-Townes limit
Authors:
S. Bartalini,
S. Borri,
P. Cancio,
A. Castrillo,
I. Galli,
G. Giusfredi,
D. Mazzotti,
L. Gianfrani,
P. De Natale
Abstract:
A comprehensive investigation of the frequency-noise spectral density of a free-running mid-infrared quantum-cascade laser is presented for the first time. It provides direct evidence of the leveling of this noise down to a white noise plateau, corresponding to an intrinsic linewidth of a few hundred Hz. The experiment is in agreement with the most recent theory on the fundamental mechanism of l…
▽ More
A comprehensive investigation of the frequency-noise spectral density of a free-running mid-infrared quantum-cascade laser is presented for the first time. It provides direct evidence of the leveling of this noise down to a white noise plateau, corresponding to an intrinsic linewidth of a few hundred Hz. The experiment is in agreement with the most recent theory on the fundamental mechanism of line broadening in quantum-cascade lasers, which provides a new insight into the Schawlow-Townes formula and predicts a narrowing beyond the limit set by the radiative lifetime of the upper level.
△ Less
Submitted 11 February, 2010; v1 submitted 14 December, 2009;
originally announced December 2009.
-
Saturated-absorption cavity ring-down spectroscopy
Authors:
G. Giusfredi,
S. Bartalini,
S. Borri,
P. Cancio,
I. Galli,
D. Mazzotti,
P. De Natale
Abstract:
We report on a novel approach to cavity-ring-down spectroscopy with the sample gas in saturated-absorption regime. This technique allows to decouple and simultaneously retrieve empty-cavity background and absorption signal, by means of a theoretical model that we developed and tested. The high sensitivity and frequency precision for spectroscopic applications are exploited to measure, for the fi…
▽ More
We report on a novel approach to cavity-ring-down spectroscopy with the sample gas in saturated-absorption regime. This technique allows to decouple and simultaneously retrieve empty-cavity background and absorption signal, by means of a theoretical model that we developed and tested. The high sensitivity and frequency precision for spectroscopic applications are exploited to measure, for the first time, the hyperfine structure of an excited vibrational state of $^{17}$O$^{12}$C$^{16}$O in natural abundance with an accuracy of a few parts in $10^{-11}$.
△ Less
Submitted 11 February, 2010; v1 submitted 4 December, 2009;
originally announced December 2009.