A Four-channel Optically Pumped Magnetometer for a Magnetoencephalography Sensor Array
Authors:
Joonas Iivanainen,
Tony R. Carter,
Jonathan E. Dhombridge,
Timothy S. Read,
Kaleb Campbell,
Quinn Abate,
David M. Ridley,
Amir Borna,
Peter D. D. Schwindt
Abstract:
We present a novel four-channel OPM sensor for magnetoencephalography that utilizes a two-color pump/probe scheme on a single optical axis. We characterize its performance across 18 built sensor modules. The new sensor implements several improvements over our previously developed sensor including lower vapor-cell operating temperature, improved probe-light detection optics, and reduced optical pow…
▽ More
We present a novel four-channel OPM sensor for magnetoencephalography that utilizes a two-color pump/probe scheme on a single optical axis. We characterize its performance across 18 built sensor modules. The new sensor implements several improvements over our previously developed sensor including lower vapor-cell operating temperature, improved probe-light detection optics, and reduced optical power requirements. The sensor also has new electromagnetic field coils on the sensor head which are designed using stream-function-based current optimization. We detail the coil design methodology and present experimental characterization of the coil performance. The magnetic sensitivity of the sensor is on average 12.3 fT/rt-Hz across the 18 modules while the average gradiometrically inferred sensitivity is about 6.0 fT/rt-Hz. The sensor 3-dB bandwidth is 100 Hz on average. The on-sensor coil performance is in good agreement with the simulations.
△ Less
Submitted 22 December, 2023;
originally announced December 2023.
-
The effect of spatial sampling on the resolution of the magnetostatic inverse problem
Authors:
Jussi Nurminen,
Andrey Zhdanov,
Wan ** Yeo,
Joonas Iivanainen,
Julia Stephen,
Amir Borna,
Jim McKay,
Peter D. D. Schwindt,
Samu Taulu
Abstract:
In magnetoencephalography, linear minimum norm inverse methods are commonly employed when a solution with minimal a priori assumptions is desirable. These methods typically produce spatially extended inverse solutions, even when the generating source is focal. Various reasons have been proposed for this effect, including intrisic properties of the minimum norm solution, effects of regularization,…
▽ More
In magnetoencephalography, linear minimum norm inverse methods are commonly employed when a solution with minimal a priori assumptions is desirable. These methods typically produce spatially extended inverse solutions, even when the generating source is focal. Various reasons have been proposed for this effect, including intrisic properties of the minimum norm solution, effects of regularization, noise, and limitations of the sensor array. In this work, we express the lead field in terms of the magnetostatic multipole expansion and develop the minimum-norm inverse in the multipole domain. We demonstrate the close relationship between numerical regularization and explicit suppression of spatial frequencies of the magnetic field. We show that the spatial sampling capabilities of the sensor array and regularization together determine the resolution of the inverse solution. For the purposes of stabilizing the inverse estimate, we propose the multipole transformation of the lead field as an alternative or complementary means to purely numerical regularization.
△ Less
Submitted 31 May, 2023;
originally announced May 2023.
-
Effects of head modeling errors on the spatial frequency representation of MEG
Authors:
Wan-** Yeo,
Eric Larson,
Joonas Iivanainen,
Amir Borna,
Jim McKay,
Julia Stephen,
Peter Schwindt,
Samu Taulu
Abstract:
Optically-pumped magnetometers (OPM) -- next-generation magnetoencephalography (MEG) sensors -- may be placed directly on the head, unlike the more commonly used superconducting quantum interference device (SQUID) sensors, which must be placed a few centimeters away. This allows for signals of higher spatial resolution to be captured, resulting in potentially more accurate source localization. In…
▽ More
Optically-pumped magnetometers (OPM) -- next-generation magnetoencephalography (MEG) sensors -- may be placed directly on the head, unlike the more commonly used superconducting quantum interference device (SQUID) sensors, which must be placed a few centimeters away. This allows for signals of higher spatial resolution to be captured, resulting in potentially more accurate source localization. In this paper, we show that in the noiseless and high signal-to-noise ratio (SNR) case of approximately $\geq 6$ dB, inaccuracies in boundary element method (BEM) head conductor models (or equivalently, inaccurate volume current models) lead to increased signal and equivalent current dipole (ECD) source localization inaccuracies when sensor arrays are placed closer to the head. This is true especially in the case of deep and superficial sources where volume current contributions are high. In the noisy case however, the higher SNR for closer sensor arrays allows for an improved ECD fit and outweighs the effects of head geometry inaccuracies. This calls for an increase in emphasis in head modeling to reduce inverse modeling errors, especially as the field of MEG strives for closer sensor arrays and cleaner signals. An analytical form to obtain the magnetic field errors for small perturbations in the BEM head geometry is also provided.
△ Less
Submitted 19 August, 2022;
originally announced August 2022.
-
Calibration and localization of optically pumped magnetometers using electromagnetic coils
Authors:
Joonas Iivanainen,
Amir Borna,
Rasmus Zetter,
Tony R. Carter,
Julia M. Stephen,
Jim McKay,
Lauri Parkkonen,
Samu Taulu,
Peter D. D. Schwindt
Abstract:
In this paper, we propose a method to estimate the position, orientation and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer a…
▽ More
In this paper, we propose a method to estimate the position, orientation and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer and model these discreetly sampled fields using vector-spherical harmonics (VSH) functions. We then localize and calibrate a sensor by minimizing the sum of squared errors between the model signals and the sensor responses to the coil fields. We show that by using homogeneous and first-order gradient fields, the sensor parameters (gain, position, and orientation) can be obtained from a set of linear equations with pseudo-inverses of two matrices. By determining the coil currents based on the VSH models, the coil fields can approximate these low-order field components, yielding computationally simple initial estimates of the sensor parameters. As a first test of the method, we placed a fluxgate magnetometer at multiple positions and estimated the RMS position, orientation, and gain errors of the method to be 1.0 mm, 0.2° and 0.8%, respectively. Last, we calibrated a 48-channel OPM array. The accuracy of the OPM calibration was tested by using the OPM array to localize magnetic dipoles in a phantom, which resulted in an average position error of 3.3 mm. The results demonstrate the feasibility of using electromagnetic coils to calibrate and localize OPMs for MEG.
△ Less
Submitted 9 March, 2022;
originally announced March 2022.
-
Hole content dependent fluctuation diamagnetism in YBa2Cu3O7-δ: possible role of the pseudogap
Authors:
Ayesha Siddika Borna,
R. S. Islam,
S. H. Naqib
Abstract:
This study focuses on the temperature and hole content dependent fluctuation diamagnetism of hole doped YBa2Cu3O7-delta (Y123) high-Tc superconductors. Two different compositions of Y123 have been considered with in-plane hole content (p): 0.161 (optimally doped) and 0.143 (underdoped). The fluctuation induced excess diamagnetic susceptibility, Delta_chi(T), has been investigated via the mean-fiel…
▽ More
This study focuses on the temperature and hole content dependent fluctuation diamagnetism of hole doped YBa2Cu3O7-delta (Y123) high-Tc superconductors. Two different compositions of Y123 have been considered with in-plane hole content (p): 0.161 (optimally doped) and 0.143 (underdoped). The fluctuation induced excess diamagnetic susceptibility, Delta_chi(T), has been investigated via the mean-field Gaussian-Ginzburg-Landau (MFGGL) formalism with and without a total energy cut-off in the fluctuating modes. It has been found that inclusion of total energy cut-off describes the Delta_chi(T) data significantly better. Furthermore, the pseudogap (PG) itself induces an anomalous decrease in the normal state magnetic susceptibility. By means of the analysis of Delta_chi(T)/T at different hole concentrations, we have explored the possible role of the PG on diamagnetic fluctuations. It has been found that MFGGL formalism is not able to reproduce the Delta_chi(T)/T features for the underdoped compound over a broad range of reduced temperature, Epsilon [= ln(T/Tc)]. The discrepancy becomes prominent in the temperature range where PG dominates the normal state magnetic susceptibility data. The agreement between the theoretical prediction and experimental Delta_chi(T) is better for the optimally doped compound with p = 0.161, where the effect of the PG is small. This notable difference implies that PG induced reduction in the magnetic susceptibility is not related directly to the superconducting fluctuations which in turn indicate that electronic correlations giving rise to the PG and Cooper pairing are independent to each other.
△ Less
Submitted 19 May, 2021;
originally announced May 2021.
-
Non-Invasive Functional-Brain-Imaging with a Novel Magnetoencephalography System
Authors:
Amir Borna,
Tony R. Carter,
Anthony P. Colombo,
Yuan-Yu Jau,
Jim McKay,
Michael Weisend,
Samu Taulu,
Julia M. Stephen,
Peter D. D. Schwindt
Abstract:
A non-invasive functional-brain-imaging system based on optically-pumped-magnetometers (OPM) is presented. The OPM-based magnetoencephalography (MEG) system features 20 OPM channels conforming to the subject's scalp. Due to proximity (12 mm) of the OPM channels to the brain, it is anticipated that this MEG system offers an enhanced spatial resolution as it can capture finer spatial features compar…
▽ More
A non-invasive functional-brain-imaging system based on optically-pumped-magnetometers (OPM) is presented. The OPM-based magnetoencephalography (MEG) system features 20 OPM channels conforming to the subject's scalp. Due to proximity (12 mm) of the OPM channels to the brain, it is anticipated that this MEG system offers an enhanced spatial resolution as it can capture finer spatial features compared to traditional MEG systems employing superconducting quantum interference device (SQUID). We have conducted two MEG experiments on three subjects: somatosensory evoked magnetic field (SEF) and auditory evoked magnetic field (AEF) using our OPM-based MEG system and a commercial SQUID-based MEG system. We have cross validated the robustness of our system by calculating the distance between the location of the equivalent current dipole (ECD) yielded by our OPM-based MEG system and the ECD location calculated by the commercial SQUID-based MEG system. We achieved sub-centimeter accuracy for both SEF and AEF responses in all three subjects.
△ Less
Submitted 6 December, 2018;
originally announced December 2018.
-
A 20-Channel Magnetoencephalography System Based on Optically Pumped Magnetometers
Authors:
Amir Borna,
Tony R. Carter,
Anthony P. Colombo,
Yuan-Yu Jau,
Christopher Berry,
Jim McKay,
Julia Stephen,
Michael Weisend,
Peter D. D. Schwindt
Abstract:
We describe a multichannel magnetoencephalography (MEG) system that uses optically pumped magnetometers (OPMs) to sense the magnetic fields of the human brain. The system consists of an array of 20 OPM channels conforming to the human subject's head, a person-sized magnetic shield containing the array and the human subject, a laser system to drive the OPM array, and various control and data acquis…
▽ More
We describe a multichannel magnetoencephalography (MEG) system that uses optically pumped magnetometers (OPMs) to sense the magnetic fields of the human brain. The system consists of an array of 20 OPM channels conforming to the human subject's head, a person-sized magnetic shield containing the array and the human subject, a laser system to drive the OPM array, and various control and data acquisitions systems. We conducted two MEG experiments: auditory evoked magnetic field (AEF) and somatosensory evoked magnetic field (SEF), on three healthy male subjects, using both our OPM array and a 306-channel Elekta-Neuromag superconducting quantum interference device (SQUID) MEG system. The described OPM array measures the tangential components of the magnetic field as opposed to the radial component measured by all SQUID-based MEG systems. Herein we compare the results of the OPM- and SQUID-based MEG systems on the auditory and somatosensory data recorded in the same individuals on both systems.
△ Less
Submitted 19 June, 2017;
originally announced June 2017.