TOFHIR2: The readout ASIC of the CMS Barrel MIP Timing Detector
Authors:
E. Albuquerque,
M. Araújo,
A. Benaglia,
A. Boletti,
R. Bugalho,
T. Coutinho,
F. De Guio,
P. Faccioli,
L. Ferramacho,
M. Firlej,
T. Fiutowski,
R. Francisco,
M. Gallinaro,
A. Ghezzi,
J. Hollar,
M. Idzik,
H. Legoinha,
N. Leonardo,
C. Leong,
M. T. Lucchini,
M. Malberti,
G. Marozzo,
G. Da Molin,
J. Moron,
T. Niknejad
, et al. (16 additional authors not shown)
Abstract:
The CMS detector will be upgraded for the HL-LHC to include a MIP Timing Detector (MTD). The MTD will consist of barrel and endcap timing layers, BTL and ETL respectively, providing precision timing of charged particles. The BTL sensors are based on LYSO:Ce scintillation crystals coupled to SiPMs with TOFHIR2 ASICs for the front-end readout. A resolution of 30-60 ps for MIP signals at a rate of 2.…
▽ More
The CMS detector will be upgraded for the HL-LHC to include a MIP Timing Detector (MTD). The MTD will consist of barrel and endcap timing layers, BTL and ETL respectively, providing precision timing of charged particles. The BTL sensors are based on LYSO:Ce scintillation crystals coupled to SiPMs with TOFHIR2 ASICs for the front-end readout. A resolution of 30-60 ps for MIP signals at a rate of 2.5 Mhit/s per channel is expected along the HL-LHC lifetime. We present an overview of the TOFHIR2 requirements and design, simulation results and measurements with TOFHIR2 ASICs. The measurements of TOFHIR2 associated to sensor modules were performed in different test setups using internal test pulses or blue and UV laser pulses emulating the signals expected in the experiment. The measurements show a time resolution of 24 ps initially during Beginning of Operation (BoO) and 58 ps at End of Operation (EoO) conditions, matching well the BTL requirements. We also showed that the time resolution is stable up to the highest expected MIP rate. Extensive radiation tests were performed, both with x-rays and heavy ions, showing that TOFHIR2 is not affected by the radiation environment during the experiment lifetime.
△ Less
Submitted 1 April, 2024;
originally announced April 2024.
Study of the effects of radiation on the CMS Drift Tubes Muon Detector for the HL-LHC
Authors:
G. Abbiendi,
J. Alcaraz Maestre,
A. Álvarez Fernández,
B. Álvarez González,
N. Amapane,
I. Bachiller,
J. M. Barcala,
L. Barcellan,
C. Battilana,
M. Bellato,
G. Bencze,
M. Benettoni,
N. Beni,
A. Benvenuti,
L. C. Blanco Ramos,
A. Boletti,
A. Bragagnolo,
J. A. Brochero Cifuentes,
V. Cafaro,
A. Calderon,
E. Calvo,
A. Cappati,
R. Carlin,
C. A. Carrillo Montoya,
F. R. Cavallo
, et al. (118 additional authors not shown)
Abstract:
The CMS drift tubes (DT) muon detector, built for withstanding the LHC expected integrated and instantaneous luminosities, will be used also in the High Luminosity LHC (HL-LHC) at a 5 times larger instantaneous luminosity and, consequently, much higher levels of radiation, reaching about 10 times the LHC integrated luminosity. Initial irradiation tests of a spare DT chamber at the CERN gamma irrad…
▽ More
The CMS drift tubes (DT) muon detector, built for withstanding the LHC expected integrated and instantaneous luminosities, will be used also in the High Luminosity LHC (HL-LHC) at a 5 times larger instantaneous luminosity and, consequently, much higher levels of radiation, reaching about 10 times the LHC integrated luminosity. Initial irradiation tests of a spare DT chamber at the CERN gamma irradiation facility (GIF++), at large ($\sim$O(100)) acceleration factor, showed ageing effects resulting in a degradation of the DT cell performance. However, full CMS simulations have shown almost no impact in the muon reconstruction efficiency over the full barrel acceptance and for the full integrated luminosity. A second spare DT chamber was moved inside the GIF++ bunker in October 2017. The chamber was being irradiated at lower acceleration factors, and only 2 out of the 12 layers of the chamber were switched at working voltage when the radioactive source was active, being the other layers in standby. In this way the other non-aged layers are used as reference and as a precise and unbiased telescope of muon tracks for the efficiency computation of the aged layers of the chamber, when set at working voltage for measurements. An integrated dose equivalent to two times the expected integrated luminosity of the HL-LHC run has been absorbed by this second spare DT chamber and the final impact on the muon reconstruction efficiency is under study. Direct inspection of some extracted aged anode wires presented a melted resistive deposition of materials. Investigation on the outgassing of cell materials and of the gas components used at the GIF++ are underway. Strategies to mitigate the ageing effects are also being developed. From the long irradiation measurements of the second spare DT chamber, the effects of radiation in the performance of the DTs expected during the HL-LHC run will be presented.
△ Less
Submitted 12 December, 2019;
originally announced December 2019.