Optical Widefield Nuclear Magnetic Resonance Microscopy
Authors:
Karl D. Briegel,
Nick R. von Grafenstein,
Julia C. Draeger,
Peter Blümler,
Robin D. Allert,
Dominik B. Bucher
Abstract:
Microscopy enables detailed visualization and understanding of minute structures or processes. While cameras have significantly advanced optical, infrared, and electron microscopy, imaging nuclear magnetic resonance (NMR) signals on a camera has remained elusive. Here, we employ nitrogen-vacancy (NV) centers in diamond as a quantum sensor, which converts NMR signals into optical signals that are s…
▽ More
Microscopy enables detailed visualization and understanding of minute structures or processes. While cameras have significantly advanced optical, infrared, and electron microscopy, imaging nuclear magnetic resonance (NMR) signals on a camera has remained elusive. Here, we employ nitrogen-vacancy (NV) centers in diamond as a quantum sensor, which converts NMR signals into optical signals that are subsequently captured by a high-speed camera. Unlike traditional magnetic resonance imaging (MRI), our method records the NMR signal over a wide field of view in real space. We demonstrate that our optical widefield NMR microscopy (OMRM) can image NMR signals in microfluidic structures with a $\sim 10\,μm$ resolution across a $\sim 235 \times 150\,μm^2$ area. Crucially, each camera pixel records an NMR spectrum providing multicomponent information about the signal's amplitude, phase, local magnetic field strengths, and gradients. The fusion of optical microscopy and NMR techniques enables multifaceted imaging applications in the physical and life sciences.
△ Less
Submitted 15 May, 2024; v1 submitted 28 February, 2024;
originally announced February 2024.
-
A Comprehensive Approach to Characterize Navigation Instruments for Magnetic Guidance in Biological Systems
Authors:
Peter Blümler,
Fabian Raudzus,
Friederike Schmid
Abstract:
The non-invasive spatiotemporal control of cellular functions, organization of tissues, and even the behavior of small animals has become paramount for advanced therapies. As magnetic fields do not interact with biological matter, their application is not only suitable for in vitro experiments but also for in vivo applications, even in deep tissues. Particularly, the remote manipulation of paramag…
▽ More
The non-invasive spatiotemporal control of cellular functions, organization of tissues, and even the behavior of small animals has become paramount for advanced therapies. As magnetic fields do not interact with biological matter, their application is not only suitable for in vitro experiments but also for in vivo applications, even in deep tissues. Particularly, the remote manipulation of paramagnetic entities through magnetic instruments has emerged as a promising approach across various biological contexts. Despite similarities in basic experimental concepts, variations in the properties and descriptions of those magnetic instruments among the authors and studies resulted in a lack of reproducibility and comparability. Therefore, this article addresses the question of how to standardize the characterization of magnetic instruments. Our emphasis lies on the ability of magnetic systems to control the movement of paramagnetic objects such as ferro- or superparamagnetic particles, within organisms. This movement is achieved by exerting a force on magnetic particles by exposing them to a locally varying magnetic field. While it is well-known that the exerted force depends on the spatial variation (i.e. the gradient) of the magnetic field, the magnitude of the field is equally important. However, this second factor is often neglected in the literature. Therefore, we conduct a comprehensive analysis and discussion of both factors. Furthermore, we propose a novel descriptor, termed "effective gradient", which combines both dependencies. To illustrate, we characterize different magnet systems by calculating and comparing the different quantities and relating them to two experiments with different superparamagnetic nanoparticles.
△ Less
Submitted 19 January, 2024;
originally announced January 2024.
-
$τ$SPECT: A spin-flip loaded magnetic ultracold neutron trap for a determination of the neutron lifetime
Authors:
J. Auler,
M. Engler,
K. Franz,
J. Kahlenberg,
J. Karch,
N. Pfeifer,
K. Roß,
C. -F. Strid,
N. Yazdandoost,
E. Adamek,
S. Kaufmann,
Ch. Schmidt,
P. Blümler,
M. Fertl,
W. Heil,
D. Ries
Abstract:
The confinement of ultracold neutrons (UCNs) in a three dimensional magnetic field gradient trap allows for a measurement of the free neutron lifetime with superior control over spurious loss channels and can provide a large kinetic energy acceptance to enhance statistical sensitivity. In this paper, we present the first successful implementation of a pulsed spin-flip based loading scheme for a th…
▽ More
The confinement of ultracold neutrons (UCNs) in a three dimensional magnetic field gradient trap allows for a measurement of the free neutron lifetime with superior control over spurious loss channels and can provide a large kinetic energy acceptance to enhance statistical sensitivity. In this paper, we present the first successful implementation of a pulsed spin-flip based loading scheme for a three-dimensional magnetic UCN trap. The measurements with the $τ$SPECT experiment were performed at the pulsed UCN source of the research reactor TRIGA Mainz. We report on detailed investigations of major systematic effects influencing the neutron storage time, statistically limited by the size of the recorded data set. The extracted neutron storage time constant of $τ= 859(16)\mathrm{s}$ is compatible with, but not to be interpreted as, a measurement of the free neutron lifetime.
△ Less
Submitted 25 October, 2023;
originally announced November 2023.
-
Microwave-free wide-field magnetometry using nitrogen-vacancy centers
Authors:
Joseph Shaji Rebeirro,
Muhib Omar,
Till Lenz,
Omkar Dhungel,
Peter Blümler,
Dmitry Budker,
Arne Wickenbrock
Abstract:
A wide-field magnetometer utilizing nitrogen-vacancy (NV) centers in diamond that does not require microwaves is demonstrated. It is designed for applications where microwaves need to be avoided, such as magnetic imaging of biological or conductive samples. The system exploits a magnetically sensitive feature of NV centers near the ground state level anticrossing (GSLAC). An applied test field fro…
▽ More
A wide-field magnetometer utilizing nitrogen-vacancy (NV) centers in diamond that does not require microwaves is demonstrated. It is designed for applications where microwaves need to be avoided, such as magnetic imaging of biological or conductive samples. The system exploits a magnetically sensitive feature of NV centers near the ground state level anticrossing (GSLAC). An applied test field from a wire was mapped over an imaging area of $\approx 500 \times 470\,μ\text{m}^2$. Analysis of the GSLAC lineshape allows to extract vector information of the applied field. The device allows micrometer-scale magnetic imaging at a spatial resolution dominated by the thickness of the NV layer (here $50\,μ\text{m}$). For a pixel size of $4\,μ\text{m} \times 3.8\,μ\text{m}$ the estimated sensitivity is $4.8\,μ\text{T}/\sqrt{\text{Hz}}$. Two modalities for visualizing the magnetic fields, static and temporal, are presented along with a discussion of technical limitations and future extensions of the method.
△ Less
Submitted 25 October, 2023;
originally announced October 2023.
-
Practical Concepts for Design, Construction and Application of Halbach Magnets in Magnetic Resonance
Authors:
Peter Blümler,
Helmut Soltner
Abstract:
This review is a compilation of relevant concepts in designing Halbach multipoles for magnetic resonance applications. The main focus is on providing practical guidelines to plan, design and build such magnets. Therefore, analytical equations are presented for estimating the magnetic field from ideal to realistic systems. Various strategies of homogenizing magnetic fields are discussed together wi…
▽ More
This review is a compilation of relevant concepts in designing Halbach multipoles for magnetic resonance applications. The main focus is on providing practical guidelines to plan, design and build such magnets. Therefore, analytical equations are presented for estimating the magnetic field from ideal to realistic systems. Various strategies of homogenizing magnetic fields are discussed together with concepts of opening such magnets without force, or combining them for variable fields. Temperature compensation and other practical aspects are also reviewed. For magnetic resonance two polarities (di- and quadrupole) are of main interest, but higher polarities are also included.
△ Less
Submitted 17 November, 2023; v1 submitted 26 May, 2023;
originally announced May 2023.
-
Demonstration of diamond nuclear spin gyroscope
Authors:
Andrey Jarmola,
Sean Lourette,
Victor M. Acosta,
A. Glen Birdwell,
Peter Blümler,
Dmitry Budker,
Tony Ivanov,
Vladimir S. Malinovsky
Abstract:
We demonstrate operation of a rotation sensor based on the $^{14}$N nuclear spins intrinsic to nitrogen-vacancy (NV) color centers in diamond. The sensor employs optical polarization and readout of the nuclei and a radio-frequency double-quantum pulse protocol that monitors $^{14}$N nuclear spin precession. This measurement protocol suppresses the sensitivity to temperature variations in the…
▽ More
We demonstrate operation of a rotation sensor based on the $^{14}$N nuclear spins intrinsic to nitrogen-vacancy (NV) color centers in diamond. The sensor employs optical polarization and readout of the nuclei and a radio-frequency double-quantum pulse protocol that monitors $^{14}$N nuclear spin precession. This measurement protocol suppresses the sensitivity to temperature variations in the $^{14}$N quadrupole splitting, and it does not require microwave pulses resonant with the NV electron spin transitions. The device was tested on a rotation platform and demonstrated a sensitivity of 4.7 $^{\circ}/\sqrt{\rm{s}}$ (13 mHz/$\sqrt{\rm{Hz}}$), with bias stability of 0.4 $^{\circ}$/s (1.1 mHz).
△ Less
Submitted 9 July, 2021;
originally announced July 2021.
-
Fiberized diamond-based vector magnetometers
Authors:
Georgios Chatzidrosos,
Joseph Shaji Rebeirro,
Huijie Zheng,
Muhib Omar,
Andreas Brenneis,
Felix M. Stürner,
Tino Fuchs,
Thomas Buck,
Robert Rölver,
Tim Schneemann,
Peter Blümler,
Dmitry Budker,
Arne Wickenbrock
Abstract:
We present two fiberized vector magnetic-field sensors, based on nitrogen-vacancy (NV) centers in diamond. The sensors feature sub-nT/$\sqrt{\textrm{Hz}}$ magnetic sensitivity. We use commercially available components to construct sensors with a small sensor size, high photon collection, and minimal sensor-sample distance. Both sensors are located at the end of optical fibres with the sensor-head…
▽ More
We present two fiberized vector magnetic-field sensors, based on nitrogen-vacancy (NV) centers in diamond. The sensors feature sub-nT/$\sqrt{\textrm{Hz}}$ magnetic sensitivity. We use commercially available components to construct sensors with a small sensor size, high photon collection, and minimal sensor-sample distance. Both sensors are located at the end of optical fibres with the sensor-head freely accessible and robust under movement. These features make them ideal for map** magnetic fields with high sensitivity and spatial resolution ($\leq$\,mm). As a demonstration we use one of the sensors to map the vector magnetic field inside the bore of a $\geq$ 100\,mT Halbach array. The vector field sensing protocol translates microwave spectroscopy data addressing all diamonds axes and including double quantum transitions to a 3D magnetic field vector.
△ Less
Submitted 1 March, 2021; v1 submitted 23 February, 2021;
originally announced February 2021.
-
High homogeneity permanent magnet for diamond magnetometry
Authors:
Arne Wickenbrock,
Huijie Zheng,
Georgios Chatzidrosos,
Joseph Shaji Rebeirro,
Tim Schneemann,
Peter Bluemler
Abstract:
Halbach magnets are a source of homogeneous magnetic field in an enclosed volume while kee** stray fields at a minimum. Here, we present the design, construction, and characterization for a 10 cm inner diameter double Halbach ring providing a homogeneous (<100 ppm over 1 x 1 x 0.5 cm3) magnetic field of around 105 mT, which will be used for a diamond based microwave-free widefield imaging setup.…
▽ More
Halbach magnets are a source of homogeneous magnetic field in an enclosed volume while kee** stray fields at a minimum. Here, we present the design, construction, and characterization for a 10 cm inner diameter double Halbach ring providing a homogeneous (<100 ppm over 1 x 1 x 0.5 cm3) magnetic field of around 105 mT, which will be used for a diamond based microwave-free widefield imaging setup. The final characterization is performed with a novel fiberized diamond-based sensor on a 3D translation stage documenting the high homogeneity of the constructed Halbach array and its suitability for the proposed use.
△ Less
Submitted 17 August, 2020;
originally announced August 2020.
-
Superfast collective motion of magnetic particles
Authors:
Olga Baun,
Peter Blümler,
Friederike Schmid,
Evgeny S. Asmolov,
Olga I. Vinogradova
Abstract:
It is well-known that magnetic forces can induce a formation of densely packed strings of magnetic particles or even sheafs of several strings (spindles). Here we show that in a sufficiently strong magnetic field, more complex aggregates of particles, translating with a much faster speed than would be for a single particle or even a spindle, can be assembled at the water-air interface. Such a supe…
▽ More
It is well-known that magnetic forces can induce a formation of densely packed strings of magnetic particles or even sheafs of several strings (spindles). Here we show that in a sufficiently strong magnetic field, more complex aggregates of particles, translating with a much faster speed than would be for a single particle or even a spindle, can be assembled at the water-air interface. Such a superfast flotilla is composed of many distant strings or spindles, playing a role of its vessels, and moves, practically, as a whole. We provide theoretical results to interpret the effect of a collective motion of such magnetic vessels. Our theory shows that, in contrast to an isolated chain or spindle, which velocity grows logarithmically with the number of magnetic particles, the speed of the interface flotilla becomes much higher, being proportional to the square root of their number. These results may guide the design of magnetic systems for extremely fast controlled delivery.
△ Less
Submitted 9 February, 2019;
originally announced February 2019.
-
Variable single-axis magnetic-field generator using permanent magnets
Authors:
Oleg Tretiak,
Peter Blümler,
Lykourgos Bougas
Abstract:
We present a design for producing precisely adjustable and alternating single-axis magnetic fields based on nested Halbach dipole pairs consisting of permanent magnets only. Our design allows for three dimensional optical and mechanical access to a region with strong adjustable dipolar fields, is compatible with systems operating under vacuum, and does not effectively dissipate heat under normal o…
▽ More
We present a design for producing precisely adjustable and alternating single-axis magnetic fields based on nested Halbach dipole pairs consisting of permanent magnets only. Our design allows for three dimensional optical and mechanical access to a region with strong adjustable dipolar fields, is compatible with systems operating under vacuum, and does not effectively dissipate heat under normal operational conditions. We present a theoretical analysis of the properties and capabilities of our design, and construct a proof-of-concept prototype. Using our prototype, we demonstrate fields of up to several kilogauss with field homogeneities of better than 5%, which are harmonically modulated at frequencies of $\sim$1Hz with a power consumption of approximately 1W. Moreover, we discuss how our design can be modified to generate adjustable quadrupolar magnetic fields with gradients as large as 9.5T/m in a region of optical and mechanical access. Our design is scalable and can be constructed to be suitable for table-top experiments, as in the case of polarimetric and magnetometric setups that require strong alternating magnetic fields, but also for large scale applications such as generators.
△ Less
Submitted 9 November, 2018;
originally announced November 2018.
-
Nuclear hyperpolarization of 3He by magnetized plasmas
Authors:
A. Maul,
P. Blümler,
P. -J. Nacher,
E. Otten,
G. Tastevin,
W. Heil
Abstract:
We describe a method to hyperpolarize 3He nuclear spins at high magnetic fields (4.7 Tesla) solely by a magnetized plasma. The conditions for such a magnetized plasma are fulfilled when the mean free path of the free electrons is much larger than their gyration radius in the rf gas discharge. Investigations are carried out in the 1-15 mbar pressure range with rf excitation at ~100 MHz. Quantitativ…
▽ More
We describe a method to hyperpolarize 3He nuclear spins at high magnetic fields (4.7 Tesla) solely by a magnetized plasma. The conditions for such a magnetized plasma are fulfilled when the mean free path of the free electrons is much larger than their gyration radius in the rf gas discharge. Investigations are carried out in the 1-15 mbar pressure range with rf excitation at ~100 MHz. Quantitative NMR measurements show that for different cell sizes and 3He densities nuclear polarizations in the range 1% to 9% are observed. We explain this phenomenon by an alignment-to-orientation conversion mechanism in the excited 2 3P state of 3He which is most efficient when the Zeeman and the spin-orbit energies are comparable. The method appears as a very attractive alternative to established laser polarization techniques (spin exchange or metastability exchange optical pum**). Application to 3He nuclear magnetometry with a relative precision of 10-12 is demonstrated.
△ Less
Submitted 22 June, 2018; v1 submitted 20 June, 2018;
originally announced June 2018.
-
Permanent magnet system to guide superparamagnetic particles
Authors:
Olga Baun,
Peter Blümler
Abstract:
A new concept of permanent magnet systems for guiding superparamagnetic particles on arbitrary trajectories is proposed. The basic concept is to use one magnet system with a strong and homogeneous (dipolar) magnetic field to magnetize and orient the particles. A second constantly graded field (quadrupolar) is superimposed to the first to generate a force. In this configuration the motion of the pa…
▽ More
A new concept of permanent magnet systems for guiding superparamagnetic particles on arbitrary trajectories is proposed. The basic concept is to use one magnet system with a strong and homogeneous (dipolar) magnetic field to magnetize and orient the particles. A second constantly graded field (quadrupolar) is superimposed to the first to generate a force. In this configuration the motion of the particles is driven solely by the component of the gradient field which is parallel to the direction of the homogeneous field. Then the particles are guided with constant force in a single direction over the entire volume. The direction can be adjusted by varying the angle between quadrupole and dipole. Since a single gradient is impossible, the other gradient component determines the angular deviation of the force. The latter can be neglected if the homogeneous field is stronger than the local contribution of the gradient field. A possible realization is a coaxial arrangement of two Halbach cylinders. A dipole produces a strong and homogeneous field to evenly magnetize the particles, while the second cylinder is a quadrupole to generate the force. A simple prototype was constructed to demonstrate the principle on several nano-particles, which were moved along a rough square by manually changing the force angle. The observed velocities of particles were always several orders of magnitude higher than the theoretical value. This discrepancy is attributed to the observed formation of long particle chains as a result of their polarization by the homogeneous field. The magnetic moment of such a chain is then the combination of that of its constituents. A complete system will consist of another quadrupole (third cylinder) to additionally scale the strength of the force by another rotation. In this configuration the device could then also be used as a simple MRI machine to image the particles.
△ Less
Submitted 12 February, 2017;
originally announced February 2017.
-
Precise Measurement of Magnetic Field Gradients from Free Spin Precession Signals of $^{3}$He and $^{129}$Xe Magnetometers
Authors:
F. Allmendinger,
P. Blümler,
M. Doll,
O. Grasdijk,
W. Heil,
K. Jungmann,
S. Karpuk,
H. -J. Krause,
A. Offenhäusser,
M. Repetto,
U. Schmidt,
Yu. Sobolev,
K. Tullney,
L. Willmann,
S. Zimmer
Abstract:
We report on precise measurements of magnetic field gradients extracted from transverse relaxation rates of precessing spin samples. The experimental approach is based on the free precession of gaseous, nuclear spin polarized $^3$He and $^{129}$Xe atoms in a spherical cell inside a magnetic guiding field of about 400 nT using LT$_C$ SQUIDs as low-noise magnetic flux detectors. The transverse relax…
▽ More
We report on precise measurements of magnetic field gradients extracted from transverse relaxation rates of precessing spin samples. The experimental approach is based on the free precession of gaseous, nuclear spin polarized $^3$He and $^{129}$Xe atoms in a spherical cell inside a magnetic guiding field of about 400 nT using LT$_C$ SQUIDs as low-noise magnetic flux detectors. The transverse relaxation rates of both spin species are simultaneously monitored as magnetic field gradients are varied. For transverse relaxation times reaching 100 h, the residual longitudinal field gradient across the spin sample could be deduced to be$|\vec{\nabla}B_z|=(5.6 \pm 0.4)$ pT/cm. The method takes advantage of the high signal-to-noise ratio with which the decaying spin precession signal can be monitored that finally leads to the exceptional accuracy to determine magnetic field gradients at the sub pT/cm scale.
△ Less
Submitted 5 August, 2016;
originally announced August 2016.
-
Permanent Magnet System for MRI with Constant Gradient mechanically adjustable in Direction and Strength
Authors:
Peter Blümler
Abstract:
A design for a permanent magnet system is proposed that generates spatially homogeneous, constant magnetic field gradients, thus creating conditions suitable for MRI without gradient coils and amplifiers. This is achieved by superimposing a weak Halbach quadrupole on a strong Halbach dipole. Rotation of either the quadrupole or the entire magnet assembly can be used to generate 2D images via filte…
▽ More
A design for a permanent magnet system is proposed that generates spatially homogeneous, constant magnetic field gradients, thus creating conditions suitable for MRI without gradient coils and amplifiers. This is achieved by superimposing a weak Halbach quadrupole on a strong Halbach dipole. Rotation of either the quadrupole or the entire magnet assembly can be used to generate 2D images via filtered back-projection. Additionally, the mutual rotation of two quadrupoles can be used to scale the resulting gradient. If both gradients have identical strength the gradient can even be made to vanish. The concept is demonstrated by analytical considerations and FEM-simulations.
△ Less
Submitted 9 October, 2015;
originally announced October 2015.
-
Spherical Fused Silica Cells Filled with Pure Helium for NMR-Magnetometry
Authors:
Andreas Maul,
Peter Blümler,
Werner Heil,
Anna Nikiel,
Ernst Otten,
Andreas Petrich,
Thomas Schmidt
Abstract:
High magnetic fields (> 1 T) are measured by NMR magnetometers with un-rivaled precision if the precessing spin sample provides long coherence times. The longest coherence times are found in diluted ${}^{3}$He samples, which can be hyperpolarized for sufficient signal strength. In order to have minimal influence on the homogeneity and value of the measured magnetic field the optimal container for…
▽ More
High magnetic fields (> 1 T) are measured by NMR magnetometers with un-rivaled precision if the precessing spin sample provides long coherence times. The longest coherence times are found in diluted ${}^{3}$He samples, which can be hyperpolarized for sufficient signal strength. In order to have minimal influence on the homogeneity and value of the measured magnetic field the optimal container for the ${}^{3}$He should be a perfect sphere. A fused silica sphere with an inner diameter of 8 mm and an outer diameter of 12 mm was made from two hemispheres by diffusion bonding leaving only a small hole for cleaning and evacuation. This hole was closed in vacuum by a CO${}_{2}$ laser and the inner volume was filled with a few mbars of ${}^3$He via wall permeation. NMR-measurements on such a sample had coherence times of 5 min. While the hemispheres were produced with < 1 $μ$m deviation from sphericity, the bonding left a step of ca. 50 $μ$m at maximum. The influence of such a mismatch, its orientation and materials in the direct vicinity of the sample are analyzed by FEM-simulations and discussed in view of coherence times and absolute fields.
△ Less
Submitted 9 September, 2015; v1 submitted 4 August, 2015;
originally announced August 2015.
-
Ultrasensitive 3He magnetometer for measurements of high magnetic fields
Authors:
A. Nikiel,
P. Blümler,
W. Heil,
M. Hehn,
S. Karpuk,
A. Maul,
E. Otten,
L. M. Schreiber,
M. Terekhov
Abstract:
We describe a 3He magnetometer capable to measure high magnetic fields (B > 0.1 Tesla) with a relative accuracy of better than 10^-12. Our approach is based on the measurement of the free induction decay of gaseous, nuclear spin polarized 3He following a resonant radio frequency pulse excitation. The measurement sensitivity can be attributed to the long coherent spin precession time T2* being of o…
▽ More
We describe a 3He magnetometer capable to measure high magnetic fields (B > 0.1 Tesla) with a relative accuracy of better than 10^-12. Our approach is based on the measurement of the free induction decay of gaseous, nuclear spin polarized 3He following a resonant radio frequency pulse excitation. The measurement sensitivity can be attributed to the long coherent spin precession time T2* being of order minutes which is achieved for spherical sample cells in the regime of motional narrowing where the disturbing influence of field inhomogeneities is strongly suppressed. The 3He gas is spin polarized in-situ using a new, non-standard variant of the metastability exchange optical pum**. We show that miniaturization helps to increase T2* further and that the measurement sensitivity is not significantly affected by temporal field fluctuations of order 10^-4.
△ Less
Submitted 27 May, 2014;
originally announced May 2014.