-
Reconstructing classes of 3D FRI signals from sampled tomographic projections at unknown angles
Authors:
Renke Wang,
Francien G. Bossema,
Thierry Blu,
Pier Luigi Dragotti
Abstract:
Traditional sampling schemes often assume that the sampling locations are known. Motivated by the recent bioimaging technique known as cryogenic electron microscopy (cryoEM), we consider the problem of reconstructing an unknown 3D structure from samples of its 2D tomographic projections at unknown angles. We focus on 3D convex bilevel polyhedra and 3D point sources and show that the exact estimati…
▽ More
Traditional sampling schemes often assume that the sampling locations are known. Motivated by the recent bioimaging technique known as cryogenic electron microscopy (cryoEM), we consider the problem of reconstructing an unknown 3D structure from samples of its 2D tomographic projections at unknown angles. We focus on 3D convex bilevel polyhedra and 3D point sources and show that the exact estimation of these 3D structures and of the projection angles can be achieved up to an orthogonal transformation. Moreover, we are able to show that the minimum number of projections needed to achieve perfect reconstruction is independent of the complexity of the signal model. By using the divergence theorem, we are able to retrieve the projected vertices of the polyhedron from the sampled tomographic projections, and then we show how to retrieve the 3D object and the projection angles from this information. The proof of our theorem is constructive and leads to a robust reconstruction algorithm, which we validate under various conditions. Finally, we apply aspects of the proposed framework to calibration of X-ray computed tomography (CT) data.
△ Less
Submitted 15 April, 2024;
originally announced April 2024.
-
Observation of Wigner cusps in a metallic carbon nanotube
Authors:
B. T. Blue,
R. Tsuchikawa,
A. Ahmadi,
Z. Zhang,
D. Heligman,
S. D. Lough,
J. Hone,
E. R. Mucciolo,
M. Ishigami
Abstract:
Previous gate-dependent conductance measurements of metallic carbon nanotubes have revealed unexplainable conductance suppressions, occurring at two different gate voltages. These were previously attributed to the gate-dependency of contact resistance. Our gate-dependent conductivity measurements on a metallic nanotube with known chirality show that these bimodal conductance suppressions are the m…
▽ More
Previous gate-dependent conductance measurements of metallic carbon nanotubes have revealed unexplainable conductance suppressions, occurring at two different gate voltages. These were previously attributed to the gate-dependency of contact resistance. Our gate-dependent conductivity measurements on a metallic nanotube with known chirality show that these bimodal conductance suppressions are the manifestations of Wigner cusps, often seen in atomic and nuclear physics experiments.
△ Less
Submitted 30 March, 2023;
originally announced March 2023.
-
Empowering Networks With Scale and Rotation Equivariance Using A Similarity Convolution
Authors:
Zikai Sun,
Thierry Blu
Abstract:
The translational equivariant nature of Convolutional Neural Networks (CNNs) is a reason for its great success in computer vision. However, networks do not enjoy more general equivariance properties such as rotation or scaling, ultimately limiting their generalization performance. To address this limitation, we devise a method that endows CNNs with simultaneous equivariance with respect to transla…
▽ More
The translational equivariant nature of Convolutional Neural Networks (CNNs) is a reason for its great success in computer vision. However, networks do not enjoy more general equivariance properties such as rotation or scaling, ultimately limiting their generalization performance. To address this limitation, we devise a method that endows CNNs with simultaneous equivariance with respect to translation, rotation, and scaling. Our approach defines a convolution-like operation and ensures equivariance based on our proposed scalable Fourier-Argand representation. The method maintains similar efficiency as a traditional network and hardly introduces any additional learnable parameters, since it does not face the computational issue that often occurs in group-convolution operators. We validate the efficacy of our approach in the image classification task, demonstrating its robustness and the generalization ability to both scaled and rotated inputs.
△ Less
Submitted 1 March, 2023;
originally announced March 2023.
-
Denoising of Three-Dimensional Fast Spin Echo Magnetic Resonance Images of Knee Joints using Spatial-Variant Noise-Relevant Residual Learning of Convolution Neural Network
Authors:
Shutian Zhao,
Donal G. Cahill,
Siyue Li,
Fan Xiao,
Thierry Blu,
James F Griffith,
Weitian Chen
Abstract:
Two-dimensional (2D) fast spin echo (FSE) techniques play a central role in the clinical magnetic resonance imaging (MRI) of knee joints. Moreover, three-dimensional (3D) FSE provides high-isotropic-resolution magnetic resonance (MR) images of knee joints, but it has a reduced signal-to-noise ratio compared to 2D FSE. Deep-learning denoising methods are a promising approach for denoising MR images…
▽ More
Two-dimensional (2D) fast spin echo (FSE) techniques play a central role in the clinical magnetic resonance imaging (MRI) of knee joints. Moreover, three-dimensional (3D) FSE provides high-isotropic-resolution magnetic resonance (MR) images of knee joints, but it has a reduced signal-to-noise ratio compared to 2D FSE. Deep-learning denoising methods are a promising approach for denoising MR images, but they are often trained using synthetic noise due to challenges in obtaining true noise distributions for MR images. In this study, inherent true noise information from 2-NEX acquisition was used to develop a deep-learning model based on residual learning of convolutional neural network (CNN), and this model was used to suppress the noise in 3D FSE MR images of knee joints. The proposed CNN used two-step residual learning over parallel transporting and residual blocks and was designed to comprehensively learn real noise features from 2-NEX training data. The results of an ablation study validated the network design. The new method achieved improved denoising performance of 3D FSE knee MR images compared with current state-of-the-art methods, based on the peak signal-to-noise ratio and structural similarity index measure. The improved image quality after denoising using the new method was verified by radiological evaluation. A deep CNN using the inherent spatial-varying noise information in 2-NEX acquisitions was developed. This method showed promise for clinical MRI assessments of the knee, and has potential applications for the assessment of other anatomical structures.
△ Less
Submitted 20 April, 2022;
originally announced April 2022.
-
LAPNet: Non-rigid Registration derived in k-space for Magnetic Resonance Imaging
Authors:
Thomas Küstner,
Jiazhen Pan,
Haikun Qi,
Gastao Cruz,
Christopher Gilliam,
Thierry Blu,
Bin Yang,
Sergios Gatidis,
René Botnar,
Claudia Prieto
Abstract:
Physiological motion, such as cardiac and respiratory motion, during Magnetic Resonance (MR) image acquisition can cause image artifacts. Motion correction techniques have been proposed to compensate for these types of motion during thoracic scans, relying on accurate motion estimation from undersampled motion-resolved reconstruction. A particular interest and challenge lie in the derivation of re…
▽ More
Physiological motion, such as cardiac and respiratory motion, during Magnetic Resonance (MR) image acquisition can cause image artifacts. Motion correction techniques have been proposed to compensate for these types of motion during thoracic scans, relying on accurate motion estimation from undersampled motion-resolved reconstruction. A particular interest and challenge lie in the derivation of reliable non-rigid motion fields from the undersampled motion-resolved data. Motion estimation is usually formulated in image space via diffusion, parametric-spline, or optical flow methods. However, image-based registration can be impaired by remaining aliasing artifacts due to the undersampled motion-resolved reconstruction. In this work, we describe a formalism to perform non-rigid registration directly in the sampled Fourier space, i.e. k-space. We propose a deep-learning based approach to perform fast and accurate non-rigid registration from the undersampled k-space data. The basic working principle originates from the Local All-Pass (LAP) technique, a recently introduced optical flow-based registration. The proposed LAPNet is compared against traditional and deep learning image-based registrations and tested on fully-sampled and highly-accelerated (with two undersampling strategies) 3D respiratory motion-resolved MR images in a cohort of 40 patients with suspected liver or lung metastases and 25 healthy subjects. The proposed LAPNet provided consistent and superior performance to image-based approaches throughout different sampling trajectories and acceleration factors.
△ Less
Submitted 19 July, 2021;
originally announced July 2021.
-
Electron-Hole Pair Generation in SiC High-Temperature Alpha Particle Detectors
Authors:
Timothy R. Garcia,
Ashutosh Kumar,
Benjamin T. Reinke,
Thomas E. Blue,
Wolfgang E. Windl
Abstract:
We demonstrate alpha-particle detection in an n-type 4H-SiC Schottky diode detector up to an unprecedented temperature of 500 °C using an Am-241 disc source. The measured spectra were used to calculate the electron-hole pair creation energy in 4H-SiC and its non-bandgap contribution, which are both found to decrease with increasing temperature. The full width at half maximum (FWHM) of the measured…
▽ More
We demonstrate alpha-particle detection in an n-type 4H-SiC Schottky diode detector up to an unprecedented temperature of 500 °C using an Am-241 disc source. The measured spectra were used to calculate the electron-hole pair creation energy in 4H-SiC and its non-bandgap contribution, which are both found to decrease with increasing temperature. The full width at half maximum (FWHM) of the measured alpha-energy peaks was found to increase exponentially with temperature due to an exponential increase of leakage current. For our measurement system, above 300 °C, where the leakage current was 10-6 A, this increase exceeded the FWHM at room temperature.
△ Less
Submitted 13 August, 2013;
originally announced August 2013.
-
Additional experimental evidence for a solar influence on nuclear decay rates
Authors:
Jere H. Jenkins,
Kevin R. Herminghuysen,
Thomas E. Blue,
Ephraim Fischbach,
Daniel Javorsek II,
Andrew C. Kauffman,
Daniel W. Mundy,
Peter A. Sturrock,
Joseph W. Talnagi
Abstract:
Additional experimental evidence is presented in support of the recent hypothesis that a possible solar influence could explain fluctuations observed in the measured decay rates of some isotopes. These data were obtained during routine weekly calibrations of an instrument used for radiological safety at The Ohio State University Research Reactor using Cl-36. The detector system used was based on a…
▽ More
Additional experimental evidence is presented in support of the recent hypothesis that a possible solar influence could explain fluctuations observed in the measured decay rates of some isotopes. These data were obtained during routine weekly calibrations of an instrument used for radiological safety at The Ohio State University Research Reactor using Cl-36. The detector system used was based on a Geiger-Mueller gas detector, which is a robust detector system with very low susceptibility to environmental changes. A clear annual variation is evident in the data, with a maximum relative count rate observed in January/February, and a minimum relative count rate observed in July/August, for seven successive years from July 2005 to June 2011. This annual variation is not likely to have arisen from changes in the detector surroundings, as we show here.
△ Less
Submitted 24 July, 2012;
originally announced July 2012.
-
A CURE for noisy magnetic resonance images: Chi-square unbiased risk estimation
Authors:
Florian Luisier,
Thierry Blu,
Patrick J. Wolfe
Abstract:
In this article we derive an unbiased expression for the expected mean-squared error associated with continuously differentiable estimators of the noncentrality parameter of a chi-square random variable. We then consider the task of denoising squared-magnitude magnetic resonance image data, which are well modeled as independent noncentral chi-square random variables on two degrees of freedom. We c…
▽ More
In this article we derive an unbiased expression for the expected mean-squared error associated with continuously differentiable estimators of the noncentrality parameter of a chi-square random variable. We then consider the task of denoising squared-magnitude magnetic resonance image data, which are well modeled as independent noncentral chi-square random variables on two degrees of freedom. We consider two broad classes of linearly parameterized shrinkage estimators that can be optimized using our risk estimate, one in the general context of undecimated filterbank transforms, and another in the specific case of the unnormalized Haar wavelet transform. The resultant algorithms are computationally tractable and improve upon state-of-the-art methods for both simulated and actual magnetic resonance image data.
△ Less
Submitted 14 June, 2011;
originally announced June 2011.