-
Bright X-ray radiation from plasma bubbles in an evolving laser wakefield accelerator
Authors:
M. S. Bloom,
M. J. V. Streeter,
S. Kneip,
R. A. Bendoyro,
O. Cheklov,
J. M. Cole,
A. Doepp,
C. J. Hooker,
J. Holloway,
J. Jiang,
N. C. Lopes,
H. Nakamura,
P. A. Norreys,
P. P. Rajeev,
D. R. Symes,
J. Schreiber,
J. C. Wood,
M. Wing,
Z. Najmudin,
S. P. D. Mangles
Abstract:
We show that the properties of the electron beam and bright x-rays produced by a laser wakefield accelerator can be predicted if the distance over which the laser self-focuses and compresses prior to self-injection is taken into account. A model based on oscillations of the beam inside a plasma bubble shows that performance is optimised when the plasma length is matched to the laser depletion leng…
▽ More
We show that the properties of the electron beam and bright x-rays produced by a laser wakefield accelerator can be predicted if the distance over which the laser self-focuses and compresses prior to self-injection is taken into account. A model based on oscillations of the beam inside a plasma bubble shows that performance is optimised when the plasma length is matched to the laser depletion length. With a 200~TW laser pulse this results in an x-ray beam with median photon energy of \unit[20]{keV}, $> 6\times 10^{8}$ photons above \unit[1]{keV} per shot and a peak brightness of $\unit[3 \times 10^{22}]{photons~s^{-1}mrad^{-2}mm^{-2} (0.1\% BW)^{-1}}$.
△ Less
Submitted 6 May, 2020; v1 submitted 16 October, 2017;
originally announced October 2017.
-
Observation of Laser Power Amplification in a Self-Injecting Laser Wakefield Accelerator
Authors:
M. J. V. Streeter,
S. Kneip,
M. S. Bloom,
R. A. Bendoyro,
O. Chekhlov,
A. E. Dangor,
A. Döpp,
C. J. Hooker,
J. Holloway,
J. Jiang,
N. C. Lopes,
H. Nakamura,
P. A. Norreys,
C. A. J. Palmer,
P. P. Rajeev,
J. Schreiber,
D. R. Symes,
M. Wing,
S. P. D. Mangles,
Z. Najmudin
Abstract:
We report on the depletion and power amplification of the driving laser pulse in a strongly-driven laser wakefield accelerator. Simultaneous measurement of the transmitted pulse energy and temporal shape indicate an increase in peak power from $187 \pm 11$ TW to a maximum of $318 \pm 12$ TW after 13 mm of propagation in plasma density of $0.9 \times 10^{18}$ cm$^{-3}$. The power amplification is c…
▽ More
We report on the depletion and power amplification of the driving laser pulse in a strongly-driven laser wakefield accelerator. Simultaneous measurement of the transmitted pulse energy and temporal shape indicate an increase in peak power from $187 \pm 11$ TW to a maximum of $318 \pm 12$ TW after 13 mm of propagation in plasma density of $0.9 \times 10^{18}$ cm$^{-3}$. The power amplification is correlated with the injection and acceleration of electrons in the nonlinear wakefield. This process is modeled by including localized redshift and subsequent group delay dispersion at the laser pulse front.
△ Less
Submitted 21 June, 2018; v1 submitted 15 October, 2017;
originally announced October 2017.
-
Probing electron acceleration and X-ray emission in laser-plasma accelerator
Authors:
C. Thaury,
K. Ta Phuoc,
S. Corde,
P. Brijesh,
G. Lambert,
S. P. D. Mangles,
M. S. Bloom,
S. Kneip,
V. Malka
Abstract:
While laser-plasma accelerators have demonstrated a strong potential in the acceleration of electrons up to giga-electronvolt energies, few experimental tools for studying the acceleration physics have been developed. In this paper, we demonstrate a method for probing the acceleration process. A second laser beam, propagating perpendicular to the main beam is focused in the gas jet few nanosecond…
▽ More
While laser-plasma accelerators have demonstrated a strong potential in the acceleration of electrons up to giga-electronvolt energies, few experimental tools for studying the acceleration physics have been developed. In this paper, we demonstrate a method for probing the acceleration process. A second laser beam, propagating perpendicular to the main beam is focused in the gas jet few nanosecond before the main beam creates the accelerating plasma wave. This second beam is intense enough to ionize the gas and form a density depletion which will locally inhibit the acceleration. The position of the density depletion is scanned along the interaction length to probe the electron injection and acceleration, and the betatron X-ray emission. To illustrate the potential of the method, the variation of the injection position with the plasma density is studied.
△ Less
Submitted 26 September, 2013;
originally announced September 2013.
-
The self-injection threshold in self-guided laser wakefield accelerators
Authors:
Stuart P. D. Mangles,
Guillaume Genoud,
Michael S. Bloom,
Matthias Burza,
Zulfikar Najmudin,
Anders Persson,
Kristoffer Svensson,
Alexander G. R. Thomas,
Claes-Goran Wahlstrom
Abstract:
A laser pulse traveling through a plasma can excite large amplitude plasma waves that can be used to accelerate relativistic electron beams in a very short distance---a technique called laser wakefield acceleration. Many wakefield acceleration experiments rely on the process of wavebreaking, or self-injection, to inject electrons into the wave, while other injection techniques rely on operation wi…
▽ More
A laser pulse traveling through a plasma can excite large amplitude plasma waves that can be used to accelerate relativistic electron beams in a very short distance---a technique called laser wakefield acceleration. Many wakefield acceleration experiments rely on the process of wavebreaking, or self-injection, to inject electrons into the wave, while other injection techniques rely on operation without self-injection. We present an experimental study into the parameters, including the pulse energy, focal spot quality and pulse power, that determine whether or not a wakefield accelerator will self-inject. By taking into account the processes of self-focusing and pulse compression we are able to extend a previously described theoretical model, where the minimum bubble size required for trap** is not constant but varies slowly with density and find excellent agreement with this model.
△ Less
Submitted 5 January, 2012;
originally announced January 2012.
-
Non-invasive characterization of transverse beam emittance of electrons from a laser-plasma wakefield accelerator in the bubble regime using betatron x-ray radiation
Authors:
S. Kneip,
C. McGuffey,
J. L. Martins,
M. S. Bloom,
V. Chvykov,
F. Dollar,
R. Fonseca,
S. Jolly,
G. Kalintchenko,
K. Krushelnick,
A. Maksimchuk,
S. P. D. Mangles,
Z. Najmudin,
C. A. J. Palmer,
K. Ta Phuoc,
W. Schumaker,
L. O. Silva,
J. Vieira,
V. Yanovsky,
A. G. R. Thomas
Abstract:
We propose and use a technique to measure the transverse emittance of a laser-wakefield accelerated beam of relativistic electrons. The technique is based on the simultaneous measurements of the electron beam divergence given by $v_{\perp}/v_{\parallel}$, the measured longitudinal spectrum $γ_\parallel$ and the transverse electron bunch size in the bubble $r_{\perp}$. The latter is obtained via th…
▽ More
We propose and use a technique to measure the transverse emittance of a laser-wakefield accelerated beam of relativistic electrons. The technique is based on the simultaneous measurements of the electron beam divergence given by $v_{\perp}/v_{\parallel}$, the measured longitudinal spectrum $γ_\parallel$ and the transverse electron bunch size in the bubble $r_{\perp}$. The latter is obtained via the measurement of the source size of the x-rays emitted by the accelerating electron bunch in the bubble. We measure a \textit{normalised} RMS beam transverse emittance $<0.5$ $π$ mm$\:$mrad as an upper limit for a spatially gaussian, spectrally quasi-monoenergetic electron beam with 230 MeV energy in agreement with numerical modeling and analytic theory in the bubble regime.
△ Less
Submitted 27 May, 2011;
originally announced May 2011.
-
X-ray phase contrast imaging of biological specimens with tabletop synchrotron radiation
Authors:
S. Kneip,
C. McGuffey,
F. Dollar,
M. S. Bloom,
V. Chvykov,
G. Kalintchenko,
K. Krushelnick,
A. Maksimchuk,
S. P. D. Mangles,
T. Matsuoka,
Z. Najmudin,
C. A. J. Palmer,
J. Schreiber,
W. Schumaker,
A. G. R. Thomas,
V. Yanovsky
Abstract:
Since their discovery in 1896, x-rays have had a profound impact on science, medicine and technology. Here we show that the x-rays from a novel tabletop source of bright coherent synchrotron radiation can be applied to phase contrast imaging of biological specimens, yielding superior image quality and avoiding the need for scarce or expensive conventional sources.
Since their discovery in 1896, x-rays have had a profound impact on science, medicine and technology. Here we show that the x-rays from a novel tabletop source of bright coherent synchrotron radiation can be applied to phase contrast imaging of biological specimens, yielding superior image quality and avoiding the need for scarce or expensive conventional sources.
△ Less
Submitted 12 May, 2011;
originally announced May 2011.