-
Multi-junction surface ion trap for quantum computing
Authors:
J. D. Sterk,
M. G. Blain,
M. Delaney,
R. Haltli,
E. Heller,
A. L. Holterhoff,
T. Jennings,
N. Jimenez,
A. Kozhanov,
Z. Meinelt,
E. Ou,
J. Van Der Wall,
C. Noel,
D. Stick
Abstract:
Surface ion traps with two-dimensional layouts of trap** regions are natural architectures for storing large numbers of ions and supporting the connectivity needed to implement quantum algorithms. Many of the components and operations needed to fully exploit this architecture have already been demonstrated, including operation at cryogenic temperatures with low heating, low excitation transport,…
▽ More
Surface ion traps with two-dimensional layouts of trap** regions are natural architectures for storing large numbers of ions and supporting the connectivity needed to implement quantum algorithms. Many of the components and operations needed to fully exploit this architecture have already been demonstrated, including operation at cryogenic temperatures with low heating, low excitation transport, and ion control and detection with integrated photonics. Here we demonstrate a trap that addresses the scaling challenge of increasing power dissipation as the RF electrode increases in size. By raising the RF electrode and removing most of the insulating dielectric layer below it we reduce both ohmic and dielectric power dissipation. We also measure heating rates across a range of motional frequencies and for different voltage sources in a trap with a raised RF electrode but solid dielectric.
△ Less
Submitted 29 February, 2024;
originally announced March 2024.
-
Multi-site Integrated Optical Addressing of Trapped Ions
Authors:
Joonhyuk Kwon,
William J. Setzer,
Michael Gehl,
Nicholas Karl,
Jay Van Der Wall,
Ryan Law,
Matthew G. Blain,
Daniel Stick,
Hayden J. McGuinness
Abstract:
One of the most effective ways to advance the performance of quantum computers and quantum sensors is to increase the number of qubits or quantum resources in the system. A major technical challenge that must be solved to realize this goal for trapped-ion systems is scaling the delivery of optical signals to many individual ions. In this paper we demonstrate an approach employing waveguides and mu…
▽ More
One of the most effective ways to advance the performance of quantum computers and quantum sensors is to increase the number of qubits or quantum resources in the system. A major technical challenge that must be solved to realize this goal for trapped-ion systems is scaling the delivery of optical signals to many individual ions. In this paper we demonstrate an approach employing waveguides and multi-mode interferometer splitters to optically address multiple $^{171}\textrm{Yb}^+$ ions in a surface trap by delivering all wavelengths required for full qubit control. Measurements of hyperfine spectra and Rabi flop** were performed on the E2 clock transition, using integrated waveguides for delivering the light needed for Doppler cooling, state preparation, coherent operations, and detection. We describe the use of splitters to address multiple ions using a single optical input per wavelength and use them to demonstrate simultaneous Rabi flop** on two different transitions occurring at distinct trap sites. This work represents an important step towards the realization of scalable integrated photonics for atomic clocks and trapped-ion quantum information systems.
△ Less
Submitted 28 March, 2024; v1 submitted 28 August, 2023;
originally announced August 2023.
-
In situ detection of RF breakdown on microfabricated surface ion traps
Authors:
Joshua M. Wilson,
Julia N. Tilles,
Raymond A. Haltli,
Eric Ou,
Matthew G. Blain,
Susan M. Clark,
Melissa C. Revelle
Abstract:
Microfabricated surface ion traps are a principle component of many ion-based quantum information science platforms. The operational parameters of these devices are pushed to the edge of their physical capabilities as the experiments strive for increasing performance. When the applied radio-frequency (RF) voltage is increased too much, the devices can experience damaging electric discharge events…
▽ More
Microfabricated surface ion traps are a principle component of many ion-based quantum information science platforms. The operational parameters of these devices are pushed to the edge of their physical capabilities as the experiments strive for increasing performance. When the applied radio-frequency (RF) voltage is increased too much, the devices can experience damaging electric discharge events known as RF breakdown. We introduce two novel techniques for in situ detection of RF breakdown, which we implemented while characterizing the breakdown threshold of surface ion traps produced at Sandia National Laboratories. In these traps, breakdown did not always occur immediately after increasing the RF voltage, but often minutes or even hours later. This result is surprising in the context of the suggested mechanisms for RF breakdown in vacuum. Additionally, the extent of visible damage caused by breakdown events increased with applied voltage. To minimize the probability for damage when RF power is first applied to a device, our results strongly suggest that the voltage should be ramped up over the course of several hours and monitored forbreakdown.
△ Less
Submitted 17 December, 2021;
originally announced December 2021.
-
The First Post-Kepler Brightness Dips of KIC 8462852
Authors:
Tabetha S. Boyajian,
Roi Alonso,
Alex Ammerman,
David Armstrong,
A. Asensio Ramos,
K. Barkaoui,
Thomas G. Beatty,
Z. Benkhaldoun,
Paul Benni,
Rory Bentley,
Andrei Berdyugin,
Svetlana Berdyugina,
Serge Bergeron,
Allyson Bieryla,
Michaela G. Blain,
Alicia Capetillo Blanco,
Eva H. L. Bodman,
Anne Boucher,
Mark Bradley,
Stephen M. Brincat,
Thomas G. Brink,
John Briol,
David J. A. Brown,
J. Budaj,
A. Burdanov
, et al. (181 additional authors not shown)
Abstract:
We present a photometric detection of the first brightness dips of the unique variable star KIC 8462852 since the end of the Kepler space mission in 2013 May. Our regular photometric surveillance started in October 2015, and a sequence of dip** began in 2017 May continuing on through the end of 2017, when the star was no longer visible from Earth. We distinguish four main 1-2.5% dips, named "Els…
▽ More
We present a photometric detection of the first brightness dips of the unique variable star KIC 8462852 since the end of the Kepler space mission in 2013 May. Our regular photometric surveillance started in October 2015, and a sequence of dip** began in 2017 May continuing on through the end of 2017, when the star was no longer visible from Earth. We distinguish four main 1-2.5% dips, named "Elsie," "Celeste," "Skara Brae," and "Angkor", which persist on timescales from several days to weeks. Our main results so far are: (i) there are no apparent changes of the stellar spectrum or polarization during the dips; (ii) the multiband photometry of the dips shows differential reddening favoring non-grey extinction. Therefore, our data are inconsistent with dip models that invoke optically thick material, but rather they are in-line with predictions for an occulter consisting primarily of ordinary dust, where much of the material must be optically thin with a size scale <<1um, and may also be consistent with models invoking variations intrinsic to the stellar photosphere. Notably, our data do not place constraints on the color of the longer-term "secular" dimming, which may be caused by independent processes, or probe different regimes of a single process.
△ Less
Submitted 2 January, 2018;
originally announced January 2018.
-
Reduction of heating rate in a microfabricated ion trap by pulsed-laser cleaning
Authors:
D T C Allcock,
L Guidoni,
T P Harty,
C J Ballance,
M G Blain,
A M Steane,
D M Lucas
Abstract:
Laser-cleaning of the electrodes in a planar micro-fabricated ion trap has been attempted using ns pulses from a tripled Nd:YAG laser at 355nm. The effect of the laser pulses at several energy density levels has been tested by measuring the heating rate of a single 40Ca+ trapped ion as a function of its secular frequency. A reduction of the electric-field noise spectral density by ~50% has been ob…
▽ More
Laser-cleaning of the electrodes in a planar micro-fabricated ion trap has been attempted using ns pulses from a tripled Nd:YAG laser at 355nm. The effect of the laser pulses at several energy density levels has been tested by measuring the heating rate of a single 40Ca+ trapped ion as a function of its secular frequency. A reduction of the electric-field noise spectral density by ~50% has been observed and a change in the frequency dependence also noticed. This is the first reported experiment where the "anomalous heating" phenomenon has been reduced by removing the source as opposed to reducing its thermal driving by cryogenic cooling. This technique may open the way to better control of the electrode surface quality in ion microtraps.
△ Less
Submitted 7 October, 2011;
originally announced October 2011.
-
Heating rate and electrode charging measurements in a scalable, microfabricated, surface-electrode ion trap
Authors:
D. T. C. Allcock,
T. P. Harty,
H. A. Janacek,
N. M. Linke,
C. J. Ballance,
A. M. Steane,
D. M. Lucas,
R. L. Jarecki Jr.,
S. D. Habermehl,
M. G. Blain,
D. Stick,
D. L. Moehring
Abstract:
We characterise the performance of a surface-electrode ion "chip" trap fabricated using established semiconductor integrated circuit and micro-electro-mechanical-system (MEMS) microfabrication processes which are in principle scalable to much larger ion trap arrays, as proposed for implementing ion trap quantum information processing. We measure rf ion micromotion parallel and perpendicular to the…
▽ More
We characterise the performance of a surface-electrode ion "chip" trap fabricated using established semiconductor integrated circuit and micro-electro-mechanical-system (MEMS) microfabrication processes which are in principle scalable to much larger ion trap arrays, as proposed for implementing ion trap quantum information processing. We measure rf ion micromotion parallel and perpendicular to the plane of the trap electrodes, and find that on-package capacitors reduce this to <~ 10 nm in amplitude. We also measure ion trap** lifetime, charging effects due to laser light incident on the trap electrodes, and the heating rate for a single trapped ion. The performance of this trap is found to be comparable with others of the same size scale.
△ Less
Submitted 24 May, 2011;
originally announced May 2011.
-
Design, Fabrication, and Experimental Demonstration of Junction Surface Ion Traps
Authors:
D. L. Moehring,
C. Highstrete,
D. Stick,
K. M. Fortier,
R. Haltli,
C. Tigges,
M. G. Blain
Abstract:
We present the design, fabrication, and experimental implementation of surface ion traps with Y-shaped junctions. The traps are designed to minimize the pseudopotential variations in the junction region at the symmetric intersection of three linear segments. We experimentally demonstrate robust linear and junction shuttling with greater than one million round-trip shuttles without ion loss. By min…
▽ More
We present the design, fabrication, and experimental implementation of surface ion traps with Y-shaped junctions. The traps are designed to minimize the pseudopotential variations in the junction region at the symmetric intersection of three linear segments. We experimentally demonstrate robust linear and junction shuttling with greater than one million round-trip shuttles without ion loss. By minimizing the direct line of sight between trapped ions and dielectric surfaces, negligible day-to-day and trap-to-trap variations are observed. In addition to high-fidelity single-ion shuttling, multiple-ion chains survive splitting, ion-position swap**, and recombining routines. The development of two-dimensional trap** structures is an important milestone for ion-trap quantum computing and quantum simulations.
△ Less
Submitted 9 May, 2011;
originally announced May 2011.
-
Integration of fluorescence collection optics with a microfabricated surface electrode ion trap
Authors:
Gregory R. Brady,
A. Robert Ellis,
David L. Moehring,
Daniel Stick,
Clark Highstrete,
Kevin M. Fortier,
Matthew G. Blain,
Raymond A. Haltli,
Alvaro A. Cruz-Cabrera,
Ronald D. Briggs,
Joel R. Wendt,
Tony R. Carter,
Sally Samora,
Shanalyn A. Kemme
Abstract:
We have successfully demonstrated an integrated optical system for collecting the fluorescence from a trapped ion. The system, consisting of an array of transmissive, dielectric micro-optics and an optical fiber array, has been intimately incorporated into the ion-trap** chip without negatively impacting trap** performance. Epoxies, vacuum feedthrough, and optical component materials were care…
▽ More
We have successfully demonstrated an integrated optical system for collecting the fluorescence from a trapped ion. The system, consisting of an array of transmissive, dielectric micro-optics and an optical fiber array, has been intimately incorporated into the ion-trap** chip without negatively impacting trap** performance. Epoxies, vacuum feedthrough, and optical component materials were carefully chosen so that they did not degrade the vacuum environment, and we have demonstrated light detection as well as ion trap** and shuttling behavior comparable to trap** chips without integrated optics, with no modification to the control voltages of the trap** chip.
△ Less
Submitted 23 September, 2010; v1 submitted 17 August, 2010;
originally announced August 2010.
-
Demonstration of a microfabricated surface electrode ion trap
Authors:
D Stick,
K M Fortier,
R Haltli,
C Highstrete,
D L Moehring,
C Tigges,
M G Blain
Abstract:
In this paper we present the design, modeling, and experimental testing of surface electrode ion traps fabricated in a heterostructure configuration comprising a silicon substrate, silicon dioxide insulators, and aluminum electrodes. This linear trap has a geometry with symmetric RF leads, two interior DC electrodes, and 40 individual lateral DC electrodes. Plasma enhanced chemical vapor depositio…
▽ More
In this paper we present the design, modeling, and experimental testing of surface electrode ion traps fabricated in a heterostructure configuration comprising a silicon substrate, silicon dioxide insulators, and aluminum electrodes. This linear trap has a geometry with symmetric RF leads, two interior DC electrodes, and 40 individual lateral DC electrodes. Plasma enhanced chemical vapor deposition (PECVD) was used to grow silicon dioxide pillars to electrically separate overhung aluminum electrodes from an aluminum ground plane. In addition to fabrication, we report techniques for modeling the control voltage solutions and the successful demonstration of trap** and shuttling ions in two identically constructed traps.
△ Less
Submitted 16 November, 2010; v1 submitted 5 August, 2010;
originally announced August 2010.